INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Quick Reference Guide INDUSTRIAL RELAYS RELAYS, CONTACTORS & CIRCUIT BREAKERS
INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS RELAYS, CONTACTORS & CIRCUIT BREAKERS TE Connectivity (TE) has extensive capabilities in the design and manufacture of relays and a broad portfolio of switching solutions for demanding, high performance applications. These relay products are remotely actuated to control electrical power flow by either interrupting or completing an electrical circuit. Complying with standardized PCB footprints, TE offers a wide range of inrush current capabilities and addresses the complete spectrum of requirements for production lines, robotics, elevators, control panels, CNC machines, motion control systems, lighting, building systems, solar, HVAC, and an array of safety-critical applications. Through agency approved test labs, we ensure that our relays are tested to meet the expectations of the industry. Whether you are designing for harsh or indoor applications, TE delivers high quality relays from state-of-the-art production lines. ROBOTICS LIGHTING HVAC SOLAR BUILDING SYSTEMS
WHAT’S INSIDE MOTION CONTROL
CONTENTS
RELAYS, CONTACTORS & CIRCUIT BREAKERS
WG type available (IEC 60335-1) Ambient temperature up to 105°C SCHRACK RE/REL Miniature PCB relays PCB area 200mm2 Wash tight SCHRACK PE Low height 10.0mm Sensitive 200mW coil Mono-or bistable coil WG type available (IEC 60335-1) Applications Industrial electronics White goods Measurement and control PLC; Timers; I/O cards Temperature control White goods Home applications HVAC Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 form C (CO) 250VAC 5A (CO) 6A (NO) 1250VA AgNi 90/10, AgSnO2 1) see footnote below 1 form A (NO) 250VAC 6/5A 1500/1250VA AgNi 0.15, AgNi 90/10 1) see footnote below 1 form A (NO) 250VAC 3A/5A (WG type) 750VA/1250VA (WG type) AgNi 100mA at 5VDC Coil Data Magnetic system Rated coil voltage Rated coil power DC, bistable 3 to 48VDC 200mW DC 5 to 48VDC 200/360mW DC 5 to 24VDC 200mW Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 1000Vrms 4000Vrms 3.2/4mm 1000Vrms 4000/3000Vrms 4/4mm 750Vrms 4000Vrms 8/>8mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions + 85°C RTII, RTIII THT PCB 20x10x10mm +70°C (RE)/ + 85°C (REL) RTIII(RE), RTII(REL) THT PCB 20x10x10.6mm/20.7x10.7x12mm + 85/ +105°C (WG type) RTII, RTIII THT PCB 20.4x7x15mm Accessories Link to datasheet SCHRACK PE SCHRACK RE SCHRACK REL PCJ Key Features Footprint 2) see footnote below INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Power PCB Relays up to 16A Relays, Contactors & Circuit Breakers 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
.500 ± .004 (12.7 ± .1) .100 ± .004 (2.54 ± .1) .067 (1.71) .300 ± .004 (7.6 ± .1) 4 – .05 DIA (1.3) Power PCB Relays up to 16A Relays, Contactors & Circuit Breakers PAGE 5 PCH Compact size WG type available (IEC 60335-1) TV-3 ratings for NO contact OJ/OJE/T77 Miniature size Sensitive coil 200mW 4kV coil-contacts (OJ/OJT) Meet UL TV-5 ratings (OJT) PCN/PCNH 1 pole 3A/5A Only 5mm wide Allows high function/packaging density RoHS compliant (Directive 2002/95/EC) Applications Appliances HVAC Refrigerators, microwave ovens Appliances HVAC Industrial control PLC Temperature control I/O modules Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 form C (CO), 1 form A (NO) 277VAC/30VDC 3/5/10A 1400VA/150W (NO) 850VA/90W (NC) AgSnO2 100mA at 5VDC 1 form A (NO) 250VAC/28VDC 3/5/8/10A 720 to 2500VA/ 90 to 240W Ag, AgCdO, AgSnO2 1) see footnote below 1 form A (NO) 250VAC 3A/5A 750VA /1250VA AgNi gold plated 100mA at 5VDC Coil Data Magnetic system Rated coil voltage Rated coil power DC, sensitive 3 to 48VDC 200/400mW DC, sensitive 3 to 48VDC 200/250/450mW DC 3 to 24VDC 100mW/120mW Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 750Vrms 4000Vrms 1.6/3.2mm 750/1000Vrms 3000/4000Vrms 1.6/3.2mm and 3.2/6.4mm 750Vrms 3000Vrms 3.5mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +70°C (standard)/+85°C (WG type) RTII, RTIII THT PCB 20x10x15.2mm up to 85°C RTII, RTIII THT PCB 18.2x10.2x14.7mm +85°C RTIII THT PCB 20x5x12.5mm Accessories Link to datasheet PCH OJ/OJE T77 PCN Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Power PCB Relays up to 16A Relays, Contactors & Circuit Breakers INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS SCHRACK SNR 5mm wide slim outline Strong coil pins for DIN-rail socket Allows high function/ packaging density SCHRACK RYII Reflow solderable version Low height 12.3mm Reinforced insulation Pinnings 3.2mm and 5mm SCHRACK MSR/T75 High inrush currents with AgSnO contacts 4kV/8mm coil-contact Reinforced insulation Applications Interface technology PLC, timers, Heating control Interface technology HVAC, PLC, Power supplies Domestic appliances Interface technology HVAC, PLC, Power supplies Domestic appliances Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 form C (CO), 1 form A (NO) 250VAC 1500VA AgSnO2 , AgSnO2 gold plated 100mA at 12VDC 1 form C (CO), 1 form A (NO), 1 from B (NC) 250VAC 2000VA AgNi0.15, AgSnO2, AgNi 0.15 gold plated 1) see footnote below 1 form C (CO) 1 form A (NO) 250VAC 8/10A 2000VA AgNi90/10, AgSnO2 1) see footnote below Coil Data Magnetic system Rated coil voltage Rated coil power DC 5 to 48VDC 170/217mW DC 5 to 60VDC (223 - 257)mW DC 3 to 60VDC (212-262)mW Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 1000Vrms 4000Vrms 6/8mm 1000Vrms 5000Vrms 8/8mm 1000Vrms 4000Vrms 8/8mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +85°C RTIII THT PCB or on socket 28x5x15mm +70°C RTII, RTIII THT, THR PCB or on socket 28.5x10.1x12.3mm +85°C RTII, RTIII THT PCB 28.6x10x15mm Accessories DIN rail sockets PCB sockets Link to datasheet SCHRACK SNR SCHRACK RYII SCHRACK MSR Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Power PCB Relays up to 16A Relays, Contactors & Circuit Breakers SCHRACK RZ High performance version available Reinforced insulation High ambient temperature version (105°C) WG type available (IEC 60335-1) AgNi and AgSnO contact versions THR (reflow) version SCHRACK RT DC and AC coil Mono-or bistable coil Reinforced insulation WG type available (IEC 60335-1) High ambient temperature version (105°C) THR (reflow) version Sensitive version Bifurcated contacts SCHRACK RT INRUSH For inrush peak currents up to 80A Mono-or bistable coil Reinforced insulation WG type available (IEC 60335-1) Applications Household appliances HVAC, Home automation Machine control, Energy control HVAC, Home automation, Machine control, Energy control Switching cabinet, Interface modules Lighting applications, Movement detectors, Motors control, Domestic appliances Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 form C (CO) 1 form A (NO) 250VAC 16A 4000VA AgNi90/10, AgSnO2 1) see footnote below 1 form C (CO), 1 from A (NO) 2 form C (CO), 2 form A (NO) 250VAC 2X8/16A 2X2000/4000VA AgNi90/10, AgSnO2 1) see footnote below 1 form C (CO) 1 from A (NO) 250VAC 16A 4000VA AgNi90/10, AgSnO2 1) see footnote below Coil Data Magnetic system Rated coil voltage Rated coil power DC 5 to 48VDC 400mW DC, AC, bistable 5 to 110VDC/24 to 230VAC 400mW/0.75VA DC, bistable 5 to 11VDC 400mW Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 1000Vrms 5000Vrms >10/10mm 1000Vrms 5000Vrms 2500Vrms >10/10mm 1000Vrms 5000Vrms >10/10mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +85°C +105°C (HOT type) +70°C (transparent cover type) RTII, RTIII THT PCB 29x12.7x15.7mm +75°C (AC type) +85°C RTII, RTIII THT, THR (DC and AC type) PCB or on socket 29x12.7x15.7mm +85°C RTII THT PCB or socket 29x12.7x15.7mm Accessories PCB and DIN rail sockets Link to datasheet SCHRACK RZ SCHRACK RT SCHRACK RT INRUSH Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Power PCB Relays up to 16A Relays, Contactors & Circuit Breakers S0418-CM
16 A, pinning 5 mm
INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS SCHRACK RTX Inrush peak currents up to 370A Bistable coil Reinforced insulation 16A rated fluorescent load acc. EN60669-1 8A electronic ballast acc. UL508 1 1/2 HP motor load acc. UL508 SCHRACK RT iPOWER High Inrush peak currents up to 165A (20ms) and 800A (200µs) Mono-or bistable coil RTS3T: 5A Electronic ballast acc. UL508 RTSET: 8A Electronic ballast acc. UL508 Test tab (manual operator) optional for RTT3T bistable versions SCHRACK RP3SL Inrush peak currents up to 120A (20ms) Mono-or bistable coil Sealed version available Applications Lighting control systems Motion sensors Home automation applications LED lighting systems, Lighting control, Movement detectors Filament and incandescent lamp Motor control Lighting control Motor control Building automation Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 from A (NO) 250VAC 16A 4000VA W (pre-make contact) + AgSnO2 1) see footnote below 1 from A (NO) 250VAC 16A 4000VA W (pre-make contact) + AgSnO2 AgSnO2 1) see footnote below 1 form A, 1 NO 250VAC 16A 4000VA AgSnO2 100mA at 12VDC Coil Data Magnetic system Rated coil voltage Rated coil power Bistable 5 to 48VDC 650mW/665mW DC, bistable 5 to 11VDC 400mW DC 6 to 110VDC 500mW Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 1250Vrms 5000Vrms min. 6/6mm 1250Vrms 5000Vrms 10/10mm 2000Vrms 4000Vrms 8/8mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +70°C RTII THT PCB 29.1x12.7x16mm RTS3L/RTS3T +105°C, RTSET +85°C RTII THT PCB 29x12.7x15.7mm (RTS3T), 29x12.7x16.0mm (RTS3L) +70°C RTII, RTIII THT PCB 29x12.6x25.5mm Accessories Link to datasheet SCHRACK RTX SCHRACK RT IPOWER SCHRACK RP3SL Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Power PCB Relays up to 16A Relays, Contactors & Circuit Breakers .48 ± .004 (12.2 ± .1) 5 – .05 DIA (1.3) .236 ± .004 (6.0 ± .1) .079 ± .004 (2.0 ± .1) .236 ± .004 (6.0 ± .1) SCHRACK RP-2POLE 1.5MM 2 pole 8A 1.5mm contact gap per pole Creepage distance complies with IEC 60950 Sealed version available SCHRACK PB/PBH Compact and simple design gives high process security High ambient temperature version up to 105°C (PBH) WG type acc. IEC 60335-1 SCHRACK ORWH Compact relay with 1 form A and 1 form C contact arrangement 10A switching capacity Applications Domestic appliances UPS Solar Inverter White goods Small home appliances Heating temperature controllers Appliances HVAC Emergency lighting Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 2 form A, 2 NO 250VAC 2000VA AgSnO2 100mA at 12VDC 1 form C (CO) 1 form A (NO) 250VAC 10A 2500VA AgNi90/10, AgSnO 1) see footnote below 1 form C (CO) 1 form A (NO) 277VAC/28VDC 10A 2770VA/360W AgZnO, AgNi 100mA at 5VDC Coil Data Magnetic system Rated coil voltage Rated coil power DC 5 to 110VDC 780mW DC 5 to 48VDC 360mW/500mW DC 5 to 24VDC 360mW Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 25000Vrms 5000Vrms 300Vrms 7/8mm 1000Vrms 2500Vrms 3/4mm / 4/5mm 750Vrms 1500Vrms 3.2mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +40°C RTII, RTIII THT PCB 29x12.6x25.5mm +85°C/+105°C RTII THT PCB 15x15x20mm +85°C RTII, RTIII THT PCB 19.0x15.5x15.8mm Accessories Link to datasheet SCHRACK RP-2POLE 1.5MM SCHRACK PB SCHRACK PBH SCHRACK ORWH Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Power PCB Relays up to 50A+ Relays, Contactors & Circuit Breakers .140 MAX. (3.56) .250 MAX. (6.35) .300 (7.62) .100 (2.54) .150 (3.81) .500 (12.7) .550 (13.97) .700 (17.78) .600 (15.24) INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Potter & Brumfield T9G High breaking capacity PCB and quick connect connections 4kV/8mm coil-contact Minimum board space (29mm x 21.5mm) UL-class F as standard Potter & Brumfield T9A High breaking capacity PCB and quick connect and chassis mount version UL-class F as standard Open version available Potter & Brumfield T9S/T9V 1 pole 35A (T9S)/40A (T9V) Contact gap 1.5mm/1.8mm min. Ambient temperature up to 85°C at 35A Production in accordance to IEC 60335-1 RoHS compliant (Directive 2002/95/EC) Applications HVAC, Appliances Industrial control Energy management HVAC Appliances Industrial controls Photovoltaic inverter Electrical vehicle loading stations Electrical vehicle Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 form C (1 CO) 1 form B (1 NC) 1 form A (1 NO) 250VAC 30A AgSnO2 1A at 12VAC/VDC 1 form C (1 CO) 1 form B (1 NC) 1 form A (1 NO) 250VAC 30A 7500VA AgCdO, AgSnInO 1A at 5VDC or 12VAC 1 form A (1NO) 277VAC (1.5mm gap), 250VAC (1.8mm gap) 35A (T9S) , 40A (T9V) 9695VA (T9S), 10000VA (T9V) AgNi 1A at 5VDC/12VAC Coil Data Magnetic system Rated coil voltage Rated coil power DC 5 to 110VDC 900mW DC 6 to 48VDC 1W/900mW Monostable 12VDC 2.25W Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 1500Vrms 4000Vrms 6.4mm / 9.5mm (UL) 8mm / 8mm (IEC) 1500Vrms 2500Vrms 3.1/6.3mm 2500Vrms 4000Vrms 3/4mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +105°C RTII, RTIII THT/Quick connect PCB 29x21.5x15.7mm +85°C RT0, RTI, RTII, RTIII THT/Quick connect PCB, panel mount 32.3x27.4x20.4mm +85°C RTII/RTIII PCB PCB 32x27x20mm Accessories Link to datasheet Potter & Brumfield T9G Potter & Brumfield T9A Potter & Brumfield T9V Potter & Brumfield T9S Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Power PCB Relays up to 50A+ Relays, Contactors & Circuit Breakers 1.618 (41.10).585 (14.86).309 (7.85) .630 (16.00) .203 TYP. (5.16) .052 TYP. (1.32) .072 TYP. (1.83) 1.000 (25.40) .162 (4.12) .365 (9.27) .185 (4.70) 2 – .071 DIA (1.8) .472 ± .008 (12.0 ± .2) 1.09 ± .008 (27.6 ± .2) .472 (12.0) .394 (10.0) 2 – .063 DIA (1.6) .244 (6.2) .228 (5.8) Potter & Brumfield T92 Switching capacity 7500VA DC or AC coil 4kV/8mm coil-contact PCB or quick connect connections or chassis mount PCF Quick connect terminal for load (PCF only) Height 26.5mm Meet 4kV dielectric voltage between coil and contact Ambient temperature 85°C PCFN SOLAR Specially designed to meet the requirements for solar Contact gap 1.5mm/1.8mm min. 200mW hold power Applications HVAC Residential/commercial appliances Industrial controls Applicances HVAC Office machines Photovoltaic Inverter Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 2 form C (2 CO) 2 form A (2 NO) 400VAC 30A 7500VAC AgCdO, AgSnInO 500mA (NO)/ 100mA (NC) at 12VAC 1 form A (1 NO) 250VAC 25A 6370VA Visit TE.com for more information 100mA at 5VDC 1 form A (1 NO) 277VAC 26A 7200VA AgSnO2 100mA at 5VDC Coil Data Magnetic system Rated coil voltage Rated coil power DC, AC 5 to 110VDC/12 to 240VAC 1.7W/4.0VA DC 6 to 24VDC 900mW DC 12VDC and 24VDC 1.5W/200mW hold power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 1500Vrms 4000Vrms 2000Vrms 8/9.5mm 1000Vrms 4000Vrms 6.7/>8mm 2500Vrms 4000Vrms 6.1/6.1mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) DC Coil +85°C; AC Coil +65°C RTI, RTII, RTIII THT/Quick connect Panel mount, PCB 52.3x34.6x30.8mm +85°C RTII THT/Quick connect (#250) PCB 30.4x16x26.5mm +85°C RTII PCB-THT PCB 30.4x16x26.5mm Accessories Link to datasheet Potter & Brumfield T92 PCF PCFN SOLAR Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Power PCB Relays up to 50A+ Relays, Contactors & Circuit Breakers Visit TE.com for more information INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Key Features Footprint 2) see footnote below Applications Lighting control, bus actuator, power distribution, circuit protection, inverter Energy counter, prepaid power meter Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 form A (1 NO) 440VAC 60A 15000VA AgSnO2 Visit TE.com for more information 1 form A (1 NO) 250VAC 100A/120A 30000VA AgSnO2 Visit TE.com for more information Coil Data Magnetic system Rated coil voltage Rated coil power Bistable 5 to 24VDC 1.5W/3W Bistable 6 to 24VDC 4.5W Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 1500Vrms 4000Vrms ≥6/9mm 2000Vrms 4000Vrms ≥10/10mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +70°C RTI PCB PCB 36.8×17.2x30.4mm +70°C RTII - flux proof PCB, Copper Visit TE.com for more information 36.8x21.8x41.9mm Accessories Link to datasheet EW60 EW100/120 EW60 1 pole 60A, 1 form A (NO) contact Polarized bistable (latching) with 1 or 2 coils NEMA 410-2011, 16A, 277VAC, electronic ballast; 20A branch circuit 480A inrush, 2.1m sec EW100/120 1 pole 120A, 1 form A (NO) contact Polarized bistable with two coils latching 4KV/ 8mm coil - contact Reinforced insulation 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Power PCB Relays up to 50A+ Relays, Contactors & Circuit Breakers PCB mount not applicable. Visit TE.com for more information PCB mount not applicable. Visit TE.com for more information Key Features Applications DC charging, Solar inverter, Energy store station Circuit protection and Safety in Industrial Machinery Industrial controls Lighting Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 form X 450VDC / 750VDC 50A/100A/150A/200A/250A/350A Visit TE.com for more information 1 form A (1 NO) 1 form C (1 CO) 1 form X (NO-DM) 2 form A (2 NO) 2 form C (2 CO) 600VAC, 28/125VDC 50A 12000VA Ag, AgCdO 1A at 12VDC/VAC Coil Data Magnetic system Rated coil voltage Rated coil power DC 12VDC, 24VDC or PWM Visit TE.com for more information DC, AC 6 to 110VDC/6 to 480VAC 2W/9.8VA Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 2000Vrms Visit TE.com for more information 2000Vrms 2000Vrms 2000Vrms >8mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +85°C RTV Screw Panel mount Visit TE.com for more information DC +80°C AC +45°C RT 0/open Screw/Quick connect Panel mount 85.7X63.8X63.5mm Accessories Dust cover Link to datasheet Potter & Brumfield PRD IHV Hermetically sealed - intrinsically safe Designed accordance to AIAG QS9000 No position sensitive RoHS compliance Potter & Brumfield PRD Contact ratings to 50A Magnetic blowout available for switching DC loads SPDT auxiliary switch available Class B insulation system 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data.
Relays, Contactors & Circuit Breakers INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Key Features Footprint 2) see footnote below Applications Safety modules Process technology Elevator and Escalator control Safety modules Process technology Elevator and Escalator control Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 form A + 1 from B (1 NO + 1 NC) 2 form C (2 CO) 250VAC 1500VA AgNi 10mA at 5VDC 3 form A + 1 form B (3 NO + 1 NC) 2 form A + 2 form B (2 NO + 2 NC) 250VAC 2000VA AgSnO2 10mA at 5VDC Coil Data Magnetic system Rated coil voltage Rated coil power DC 5 to 110VDC 700mW DC 5 to 110VDC 800mW Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 1500Vrms 4000Vrms 3000Vrms 8/8mm 1500Vrms 4000Vrms 2500Vrms 10/10mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +70°C RTIII THT/Plug-in PCB/Socket 29x12.6x25.5mm +70°C RTIII THT PCB 40x13x16.5mm Accessories Sockets and relay clips Link to datasheet SCHRACK SR2M SCHRACK SR4 D/M SCHRACK SR2M 2 pole relay with force guided contacts according to EN50205 Reinforced insulation between poles SCHRACK SR4 D/M 4 pole relay with force guided contacts according to EN50205 Compact design, space efficient 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers Key Features Footprint 2) see footnote below Applications Safety modules Process technology Elevator and escalator control Safety modules Process technology Elevator and escalator control Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 3 form A + 1 form B (3 NO + 1 NC) 2 form A + 2 form B (2 NO + 2 NC) 3 form A + 3 form B (3 NO + 3 NC) 4 form A + 2 form B (4 NO + 2 NC) 5 form A + 1 form B (5 NO + 1 NC) 250VAC 2000VA AgSnO2 10mA at 5VDC 2 form B + 5 form A (2 NC + 5 NO) 250VAC 1500VA Ag alloy 10mA at 5VDC Coil Data Magnetic system Rated coil voltage Rated coil power DC 5 to 110VDC 1200/800mW DC 5 to 110VDC 700mW Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 1500Vrms 4000Vrms 3000/4000Vrms 5.5/5.5mm, 15/15mm 1000Vrms 2500/4000Vrms 2500/4000Vrms ≥3/4mm and ≥5.5/5.5mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +70°C RTIII THT PCB 55x16.5x16.5mm +85°C RTII THT PCB 55.5x33.8x10.8mm Accessories Link to datasheet SCHRACK SR6 SCHRACK SRL7 SCHRACK SR6 4/6 pole relay with force guided contacts according to EN50205 Reinforced insulation between all contacts depending on version SCHRACK SRL7 7 pole relay with force guided contacts according to EN50205 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS SCHRACK SLIM INTERFACE SNR Strong coil pins for DIN-rail socket LED and protection circuit standard 4kV coil-contact, 6/8mm clearance/ creepage System width only 6.2mm SCHRACK INTERFACE RELAY RT Strengthened pins designed to plug into DIN-rail-sockets Cadmium-free contacts Complete interface solutions available Modular concept socket/relay/module SCHRACK INTERFACE RELAY XT Manual test tab, optionally lockable Mechanical and electrical indicator Reinforced insulation 4kV/8mm dielectric strength between coil and contact Applications Interface technology Panel board Mechanical engineering Panel board Mechanical engineering Machine Industry Panel boards Mechanical engineering Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 form C, (CO) 250VAC 1500VA AgSnO2, AgSnO2 Au plated 1) see footnote below 1 form C, (1 CO) 2 form C, (2 CO) 240VAC 8/16A 2000/4000VA AgSnO2, AgNi90/10 AgNi90/10 Au plated 1) see footnote below 1 form C, (1 CO) 2 form C, (2 CO) 240VAC 8/16A 2000/4000VA AgNi90/10 10mA at 12VDC Coil Data Magnetic system Rated coil voltage Rated coil power DC 5 to 60VDC 170mW DC, AC 5 to 110VDC/24 to 230VAC 400mW/0.75VA DC, AC 12 to 110VDC/24 to 230VAC 400mW/0.75VA Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 1000Vrms 4000Vrms ≥6/8mm 1000Vrms 4000/5000Vrms 2500Vrms ≥8/8mm 1000Vrms 4000/5000Vrms 2500Vrms ≥8/8mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) Relay +85°C, in socket +55°C RTIII Plug-in Socket 28x5x15mm +70/+85°C RTII Plug-in Socket 29x13x15.7mm +70/+85°C RTII Plug-in Socket 29x13x26.7mm Accessories DIN rail sockets, jumper bars DIN rail and PCB sockets, clips, marking tags, modules, jumper bars DIN rail and PCB sockets, clips, marking tags, modules, jumper bars Link to datasheet SCHRACK SLIM INTERFACE SNR SCHRACK INTERFACE RELAY RT SCHRACK INTERFACE RELAY XT Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers .210 (5.33) .320 (8.13) .110 (2.79) .450 (11.43) .550 (13.97) .420 (10.67) .530 (13.46) .400 (10.16) .630 (16.00) .740 (18.80) HOLES + .004 - .000 + .10 - .00 DIA..056 1.42( ) .086 DIA. (2.18) .394 (10.01).185 (4.70).232 (5.89) .559 (14.20) .285 (7.24) Potter & Brumfield R10 Broad range of coil options provide sensitivity ranging from 25 to 750mW Various contacts switch from dry circuit to 7.5A Many mounting and termination options SCHRACK PT/ Potter & Brumfield KH Sensitive coil Low height 29/33mm Manual test tab, optionally lockable Mechanical indicator Optional LED, protection diode Potter & Brumfield K10 Mounting options include socket, PCB, top flange DC and AC coils LED versions available Applications Coin changers Audio equipment Ultrasonic test equipment Machine industry Elevator industry Building management Industrial controls Motor controls Industrial timers Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1, 2, 3, 4, 6, 8 form C (CO) 115VAC, 115VDC 0.5/2/3/7.5A 862VA max. Ag, AgCdO, Ag w/ Au overlay Dry circuit to 300mA at 12VDC 2 form C (2 CO) 3 form C (3 CO) 4 form C (4 CO) 240VAC 1/2/5/6/10/12A 1500/2500/3000VA AgNi90/10, AgNi90/10 Au plated 1) Bifurcated contacts for dry circuit available on KH 2 form C (2 CO) 120/240VAC 10/15A 1800/2500VA AgCdO, AgNi90/10 1) see footnote below Coil Data Magnetic system Rated coil voltage Rated coil power DC, AC 3 to 115VDC/6 to 115VAC 36mW to 1.6W/1.5VA DC, AC 6 to 220VDC/6 to 240VAC 750 to 900mW/1 to 1.2VA DC, AC 6 to 220VDC/6 to 240VAC 750 to 900mW/1 to 1.2VA Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 500/1000Vrms 1000Vrms 1000Vrms Visit TE.com for more information 1200Vrms 2500Vrms 2000/2500Vrms ≥4/4mm 1200/1000Vrms 2500/1500Vrms 2500/1500Vrms ≥3.1/3.1mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +75°C RTI, RTIII Solder/plug-in and PCB Socket, panel mount and PCB 29.6x18.7x30.2mm +70°C RTII THT, plug-in, Quick connect Socket, PCB 28x22.5x29/30/36mm +70°C RTII Quick connect, solder, PCB Socket and bracket mount 28x22.5x29/34.9mm Accessories Solder/PCB sockets, clips, hold down strap, mounting strip DIN rail and PCB sockets, clips, marking tags, modules, jumper bars Screw, solder and PCB sockets and clips Link to datasheet Potter & Brumfield R10 Potter & Brumfield KHA SCHRACK PT Potter & Brumfield K10 Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers .328 (8.33) .510 (12.95) .170 (4.32) .076 DIA. TYP. (1.93) .626 (15.90) .340 (8.64) 1.020 (25.91) .206 (5.23) PCB mount not applicable. Visit TE.com for more information INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Potter & Brumfield KRPA/MT Industry standard octal/undecal type termination for quick installation DC and AC coils Mechanical indicator, indicator lamp and push-to-test options SCHRACK RM2/3/7 Wide selection of termination and mounting styles PC terminals available Push to test button and indicator lamps Class B coil insulation Potter & Brumfield KUP/ KUMP/KUIP Wide selection of termination and mounting styles Broad range of contact forms PC terminals available Push to test button and indicator lamps Class B coil insulation Applications Mechanical engineering Elevator control, Plant control Baggage handling Elevator control Power supplies HVAC Pump motor controls Hospital beds Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 form C (1 CO) (KRPA) 2 form C (2 CO) 3 form C (3 CO) 240VAC 4/10A 500/2400/2500VA AgCdO, AgNi90/10, AgNi90/10 Au plated 1) see footnote below 2 form C (2 CO) 3 form C (3 CO) 400VAC 10/16A 3800/6000VA AgCdO, AgNi90/10 in preparation 100mA at 12VDC 1, 2, 3, 4 form C (CO) 1, 2, 3 form A (NO) 2, 3 form B (NC) 1 form X (NO-DM) 1 form Y (NC-DB) 1 from Z (CO-DM/DB) 240VAC 10/15A 2400/4155VA Ag, AgCdO, AgSnOInO 100mA at 12VDC(Ag) 300mA at 12VDC (AgCdO, AnSnOInO) Coil Data Magnetic system Rated coil voltage Rated coil power DC, AC 6 to 220VDC/6 to 240VAC 760mW to 1.3W/0.74 to 2.3VA DC, AC 6 to 220VDC/6 to 400VAC 1.2 to 1.8W/2 to 2.8VA DC, AC 5 to 110VDC/6 to 240VAC 1.2 to 1.8W/2 to 2.7VA Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 1000/1500Vrms 1000/2500Vrms 1000/2500Vrms ≥2.8/4mm 1500Vrms 2500Vrms 2500Vrms ≥4/14.9mm 1200Vrms 2200/3750Vrms 2200Vrms Visit TE.com for more information Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) DC +60/+70°C AC +50/+55°C RTI Plug-in Socket 35.7x35.7x50.8/57mm +50/+70°C RTI THT, Plug-in, solder, Quick connect Socket, PCB, bracket, flange mount and DIN-snap-on 38.5x35.5x48.5mm DC +50/+70/+95°C AC +45/+55/+70°C RTI THT, Plug-in, solder, Quick connect Socket, PCB, bracket, flange, stud and tapped core 38.9x35.7x48.4mm Accessories DIN rail and PCB sockets, clips, marking tags, modules DIN rail and PCB sockets, clips DIN rail, panel and PCB sockets, clips Link to datasheet Potter & Brumfield KRPA SCHRACK MT SCHRACK RM2/3/7 Potter & Brumfield KUIP KUGP KUM KUMP KUP Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers .875 (22.23) .243 (6.17) .240 (6.10) .397 (10.08) .076 DIA. TYP. (1.93) PCB mount not applicable. Visit TE.com for more information SCHRACK RM8/C/D Power relay with push-on and solder terminals Various mounting options Indicator lamps and mechanical indicator Optional push to test button Potter & Brumfield KUHP Power relay with push-on and solder terminals Various mounting options Designed to meet VDE space requirements Class B coil insulation SCHRACK RM5/6/B 3MM 3mm contact gap DC or AC coil Push-to-test button Plug-in version, PCB terminals or chassis or DIN-rail mount Applications Cleaning equipment Heating equipment Cooling equipment Baggage handling motors Industrial pumps Commercial ovens Power supplies Pump control Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 form C (1 CO) 2 form C (2 CO) 1 form Z contact (1 NO + 1 NC) 1 form X contact (1 NO) 400VAC 25/30/32A 6000/7500VA AgCdO, AgNi90/10 100mA at 12VDC 1 form C (1 CO) 2 form C (2 CO) 240VAC, 50/60Hz; 28VDC 20/30A 4800/7200VA AgCdO, AgSnOInO 300mA at 12VDC 2 form A (2 NO) 3 form A (3NO) 240/400VAC 10/16A 3800/6000VA AgCdO, AgNi90/10 in preparation 100mA at 12VDC Coil Data Magnetic system Rated coil voltage Rated coil power DC, AC 6 to 220VDC/6 to 400VAC 1.2W/2.7VA DC, AC 6 to 110VDC 50/60Hz. 6 to 277VAC 1.2W/2.7VA DC, AC 6 to 220VDC/6 to 400VAC 1.2W/2.7VA Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 1500/2000Vrms 2500Vrms 4000Vrms ≥4/14.9mm 1200Vrms 3750Vrms 3750Vrms Visit TE.com for more information 2500Vrms 2500Vrms 2500Vrms ≥4/14.9mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) DC +60/+65°C AC +40°C RTI Solder/Quick connect Bracket, top flange panel mount and DIN snap-on 38.5x35.5x48.5mm DC +45°C AC +75°C RTI, RT0 Solder/PCB THT/Quick connect Bracket and top flange panel mount 38.9x35.7x48.4mm +50/+60°C RTI Plug-in, solder, Quick connect, PCB THT Socket, PCB, bracket, flange mount and DIN-snap-on 38.5x35.5x48.5mm Accessories No sockets No sockets DIN rail and PCB sockets, clips Link to datasheet SCHRACK RM8C/D SCHRACK RM 8 Potter & Brumfield KUHP SCHRACK RM5/6/B 3MM Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers .626 (15.90) .328 (8.33) .437 (11.10) .875 (22.23) .076 DIA. TYP. (1.93) .206 (5.23) 1.406 MAX. (35.71) 1.531 MAX. (38.89) 1 2 3 4 5 6 7 8 9 A B 2.156 MAX. (54.76) .281 REF. (7.14) .626 (15.90) .328 (8.33) .875 (22.23) .076 DIA. TYP. (1.93) .206 (5.23) INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Potter & Brumfield KUGP 3mm contact gap DC or AC coil Plug-in version, PCB terminals or chassis mount Potter & Brumfield KUL Magnetic latching Single and dual coils Panel mounting Potter & Brumfield KUEP 10A relay with various contact arrangements Magnetic blowout for 150VDC load switching Indicator lamp option Applications Voltage control units Alarm systems Machine tools Battery chargers DC load switvhing in industrial controls Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 form C (1 CO) 2 form A (2 NO) 2 form C (2 CO) 3 form C (3 CO) 240/400VAC 10A 2400VA Ag, AgCdO 100mA at 12VDC (Ag) 300mA at 12VDC (AgCdO) 1 form C (1 CO) 2 form C (2 CO) 3 form C (3 CO) 28/240VAC 10A Ag, AgCdO 100mA at 12VDC (Ag) 300mA at 12VDC (AgCdO) 1 form X (NO-DM) 2 form A (2 NO) 2 form C (2 CO) 150VDC/240VAC 10A 1500W/2400VA AgCdO, AgSnOInO 300mA at 12VDC Coil Data Magnetic system Rated coil voltage Rated coil power DC, AC 6-110VDC/6-240VAC 1.8W/2.7VA DC, AC 12 to 48VDC/24 to 120/240VAC 1.6W dual coil/1.2W single coil DC, AC 5 to 110VDC/6 to 240VAC 1.2W to 1.8W/2 to 2.7VA Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 3500Vrms 2200Vrms 2200Vrms >8mm 500Vrms 1500Vrms 1500Vrms Visit TE.com for more information 1200Vrms 2200Vrms 2200Vrms Visit TE.com for more information Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) DC +75°C AC +70°C RTI THT, Plug-in, solder, Quick connect, PCB Socket, PCB, bracket, flange mount 38.9x35.7x48.4mm DC +70°C AC +50/+70°C RTI .187 Quick connect, solder Socket, bracket 38.9x35.7x54.8mm AC +55/+70°C DC +50/+70°C RTI Quick connect, solder and PCB Socket, PCB, bracket and top flange mount 38.9x35.7x48.4mm Accessories DIN rail and PCB sockets, clips Screw, solder, PCB and Quick connect sockets and clips DIN rail, track mount, chassis mount, and snap-in sockets, clips Link to datasheet Potter & Brumfield KUGP Potter & Brumfield KUL Potter & Brumfield KUEP Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers Key Features
Applications
Switching power / Max. break Min. recommended contact load 1 form C (1 CO) 2 form C (2 CO) 3 form C (3 CO) 4 form C (4 CO) 240/250VAC 6 to 16A 1 form C (1 CO) 2 form C (2 CO) 3 form C (3 CO) 4 form C (4 CO) 240/250VAC 6 to 16A 1500 to 4000VA 1) see footnote below Coil Data Magnetic system Rated coil voltage Rated coil power DC, AC 6 to 220VDC/6 to 230VAC 170 to 700mW/0.4 to 1VA Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) IP20 Screw, screwless, plate mount, PCB Screw, screwless Accessories PCB, panel mount and DIN rail DIN, panel mount Link to datasheet ACCESSORIES SLIM INTERFACE RELAY SNR ACCESSORIES INDUSTRIAL POWER RELAY RT ACCESSORIES MINIATURE RELAY PT ACCESSORIES INTERFACE PLUG-IN RELAY XT RELAY PACKAGE RT RELAY PACKAGE PT RELAY PACKAGE SNR ACCESSORIES MULTIMODE RELAY MT ACCESSORIES DIN rail and PCB sockets Screw and screwless fingersafe terminals Retaining and ejection clips Marking tags, jumper bars, jumper links LED and protection modules SETS Relay package consisting of relay, DIN rail socket, plastic retaining clip, marking tag and module Key Features 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data.
Relays, Contactors & Circuit Breakers INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Axicom IM 4G telecom/signal relay/switching relay Slim line 10x6mm, low-profile 5.65mm Switching power 60W/62.5VA Switching voltage 220VDC/250VAC Monostable + Bistable Low rated coil power High dielectric version High current version up to 5 A High contact stability version Bifurcated contacts + single contact Axicom IMB 4G telecom/signal relay/switching relay Slim line 10x6mm, low-profile 5.65mm Switching power 60W/62.5VA Switching voltage 220VDC/250VAC Monostable + Bistable Very high dielectric version Bifurcated contacts Axicom IMC 4G telecom/signal relay/switching relay Slim line 10x6mm, low-profile 5.65mm Switching power 60W/62.5VA Switching voltage 220VDC/250VAC Monostable + Bistable High dielectric version High current version up to 4 A Bifurcated contacts Applications Telecommunication, access and transmission equipment Thermostat controls, fire and security equipment Measurement and test equipment, Industrial controls, medical equipment Telecommunication, access and transmission equipment Thermostat controls, fire and security equipment Measurement and test equipment, Industrial controls, medical equipment Telecommunication, access and transmission equipment Thermostat controls, fire and security equipment Measurement and test equipment, Industrial controls, medical equipment Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Min. recommended contact load Initial contact resistance 2 form C, 2 CO Single contact + Bifurcated contacts 250VAC/220VDC 2/5A 60W/62.5VA 100µV/1µA <50mΩ at 10mA/30mV I: < 100mΩ 1 form A, 1 NO Bifurcated contacts 250VAC/220VDC 60W/62.5VA 100µV/1µA <100mΩ at 10mA/30mV 1 form C, 1 CO Bifurcated contacts 250VAC/220VDC 2/4A 60W/62.5VA 100µV/1µA <50mΩ at 10mA/ 30mV Coil Data Magnetic system Rated coil voltage Rated coil power DC coil / bistable 1 coil/2 coils Polarized 1.5 to 24VDC 50 to 200mW-/- Polarized 1.5 to 24VDC 140mW/-/- Polarized 1.5 to 24VDC 140mW/-/- Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Initial surge withstand voltage between open contacts between contact and coil between adjacent contacts Isolation 100/900MHz Insertion loss 100/900MHz Volt. standing wave ratio 100/900MHz Capacitance between open contacts 750 to 1500Vrms 1500 to 1800Vrms 750 to 1800Vrms 1000 to 2500V 2000 to 2500V 1000 to 2500V 37.0/18.8dB 0.03/0.33dB 1.06/1.49 max. 1pF 2500Vrms 3500Vrms 3500V 4900V 37.0/18.8dB 0.03/0.33dB 1.06/1.49 max. 1pF 1000 to 1600Vrms 1800 to 2200Vrms 1500 to 2200V 2500 to 3000V 37.0/18.8dB 0.03/0.33dB 1.06/1.49 max. 1pF Other Data Ambient temperature (max.) Category of environmental protection Terminal type Dimension (lwh) -40 to +85°C IP67/RTV THT, SMT 10x6x5.65mm -40 to +85°C IP67/RTV THT, SMT 10x6x5.65mm -40 to +85°C IP67/RTV THT, SMT 10x6x5.65mm Link to datasheet Axicom IM Axicom IMB Axicom IMC Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers Axicom IMD/IME 4G telecom/signal relay/switching relay Slim line 10x6mm, low-profile 5.65mm Switching power 60W/62.5VA Switching voltage 220VDC/250VAC Monostable Bifurcated contacts Axicom P2 / P2 HIGH DIELECTRIC VERSION Small Signal relay Slim line 15x7.5mm Switching current max. 5A High dielectric version Meets Telcordia Technologies Inc. requirements Axicom P2 LIGHTING Small signal relay Slim line 15x7.5mm Switching current max. 5A High dielectric strength 3kV VDE certified for LED tubes Key Features Footprint 2) see footnote below Applications Telecommunication, access and transmission equipment, fire and security equipment Thermostat controls Measurement and test equipment, Industrial controls, medical equipment Security systems, consumer electronics, thermostats Home automation systems, communication systems Set top boxes, office equipment LED tubes Office equipment Security systems, set top boxes Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Min. recommended contact load Initial contact resistance 2 form B, 2 NC 2 form A, 2 NO Bifurcated contacts 250VAC/220VDC 60W/62.5VA 100µV/1µA <50mΩ at 10mA/20mV 2 form C, 2 CO Bifurcated contacts 250VAC/220VDC 60W/62.5VA 100µV/1µA <50mΩ at 10mA/20mV 2 form C, 2 CO Bifurcated contacts 250VAC/220VDC 60W/62.5VA 100µV/1µA <50mΩ at 10mA/20mV Coil Data Magnetic system Rated coil voltage Rated coil power DC coil / bistable 1 coil/2 coils Polarized 1.5 to 24VDC 140mW/-/- Polarized 2.4 to 24VDC 140mW/70mW/140mW Polarized 3 to 12VDC 140mW - 1 coil version Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Initial surge withstand voltage between open contacts between contact and coil between adjacent contacts Isolation 100/900MHz Insertion loss 100/900MHz Volt. standing wave ratio 100/900MHz Capacitance between open contacts 1000Vrms 1800Vrms 1000Vrms 1500V 2500V 1500V 37.0/18.8dB 0.03/0.33dB 1.6/1.49 max. 1pF 1000 to 1500Vrms 1500Vrms 1000 to 1500Vrms 2000 to 2500Vrms 2500V 2500V 1500Vrms 3000Vrms 1500Vrms 6000Vrms Other Data Ambient temperature (max.) Category of environmental protection Terminal type Dimension (lwh) -40 to +85°C IP67/RTV THT, SMT 10x6x5.65mm -40 to +85°C RTIII THT, SMT 14.5x7.2x10.4mm, stnd 14.5x7.2x9.9mm, ovrmld -40 to +85°C RTIII THT, SMT 14.5x7.2x9.9mm, ovrmld Link to datasheet Axicom IMD/IME Axicom P2 / P2 HIGH DIELECTRIC VERSION Axicom P2 LIGHTING 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Axicom FP2 Slim line 14x9mm 2 form C bifurcated contacts High mechanical shock resistance, up to 1500g survival Axicom D2N V23105 2G telecom/signal relay 4 coil sensitivities 3A UL rating Key Features Footprint 2) see footnote below Applications Communication equipment Keyless entry Speaker switch, consumer electronics Communication equipment Office equipment Measurement and control equipment Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Min. recommended contact load Initial contact resistance 1 form C (CO) 220VDC/250VAC 60W/62.5VA 100µV <50mΩ at 10mA 2 form C, 2 CO Single Contacts 250VAC/220VDC 60W/125VA 100µV/10µA <100mΩ Coil Data Magnetic system Rated coil voltage Rated coil power DC coil/bistable 1 coil/2 coils Polarized 2 to 24VDC 80mW (high sensitive), 140mW Non polarized 3 to 48VDC 150 to 700mW/-/- Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Initial surge withstand voltage between open contacts between contact and coil between adjacent contacts Isolation/Cross talk at 100MHz/900MHz Insertion loss 100/900MHz Volt. standing wave ratio 100/900MHz Capacitance between open contacts 750Vrms 1000Vrms 1000Vrms 1100V 1500V 1500V Cross talk -40.2/-22.3dB 0.03dB/0.25dB 1.01/1.07 750Vrms 1000Vrms 750Vrms 1500V 1500V 1500V Isolation -39.0/-20.7dB -0.02/-0.27dB 1.04/1.40 max. 2pF Other Data Ambient temperature (max.) Category of environmental protection Terminal type Dimension (lwh) -40 to +85°C IP67/RTIII THT 14x9x5mm -25 to +85°C IP67/RTIII THT 20.2x10x11.4mm Link to datasheet Axicom FP2 Axicom D2N V23105 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers Key Features Footprint Axicom MT2 2G telecom/signal relay 5 coil sensitivities 2A UL rating Axicom P1 V23026 Very high sensitive relay Low-profile High vibration and shock resistance Version: symmetric pin layout Temperature range up to 85°C 1500Vrms across opened contacts Key Features Footprint 2) see footnote below Applications Communication equipment Linecard application Measurement and control equipment Automotive equipment CAN bus Imobilizer Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Min. recommended contact load Initial contact resistance 2 form C, 2 CO Bifurcated contacts 250VAC/220VDC 60W/62.5VA 100µV/1µA <70mΩ 1 form C, 1 CO Bifurcated contacts 150VAC/125VDC 30W/60VA 100µV/1µA <50mΩ Coil Data Magnetic system Rated coil voltage Rated coil power DC coil/bistable 1 coil/2 coils Non polarized 3 to 48VDC 150 to 550mW/-/- Polarized 3 to 24VDC 65 to 130mW/30 to 130mW/70 to 200mW Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Initial surge withstand voltage between open contacts between contact and coil between adjacent contacts Isolation 100/900MHz Insertion loss 100/900MHz Volt. standing wave ratio 100/900MHz Capacitance between open contacts 750Vrms 1000Vrms 750Vrms 1500V 1500V 1500V -31.8/-14.2dB -0.02/-0.97dB 1.03/1.31 max. 2pF 500Vrms 1500Vrms 2500V -30.0/-18.0dB -0.12/-1.90dB 1.06/1.75 max. 5pF Other Data Ambient temperature (max.) Category of environmental protection Terminal type Dimension (lwh) -55 to +85°C IP67/RTIII THT 20.2x10x11mm -40 to +85°C IP67/RTIII THT, SMT 13x7.6x6.9mm Link to datasheet Axicom MT2 Axicom P1 V23026 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
.300 (7.62) (5.08) (2.54) 6 – 0.31 DIA (.8) 5 – .04 DIA. (1.0) .397 (10.1) .299 (7.6) .098 (2.5) Signal Relays Relays, Contactors & Circuit Breakers INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Axicom REED DIP/SIL Direct driving with TTL signals Ultrasonic cleanable High switching speed Clamping diode Electrostatic shield TSC Designed for thermostat, modem Computer peripherals, video recording and security application Low coil power requirements IC compatibility OUAZ/T81 Gold overlay silver palladium alloy contact suitable for low loads High density available on PCB due to small size 2.54mm terminal pitch same as IC socket terminal pitch Sensitive and standard coils Key Features Footprint 2) see footnote below Applications Incircuit tester Measuring and control systems Alarm and security equipment Telecommunications Office machine Telecommunications Logic and process control Vending machines Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Min. recommended contact load Initial contact resistance 1 form A, 1 NO 2 form A, 2 NO 1 from C, 1 CO Reed contacts 175 to 200VAC/VDC 0.25 to 0.5A 3 to 10W 10µV/1µA <150mΩ 1 form C, 1 CO 120VAC, 30VDC 120VA, 24W 1mA at 1VDC 50mΩ at 100mA, 6VDC 1 form C, 1 CO 1 form A, 1 NO 120VAC/24VDC 120VA, 30W 1mA at 1VDC Coil Data Magnetic system Rated coil voltage Rated coil power DC coil/bistable 1 coil/2 coils Non polarized 5 to 24VDC 50 to 300mW/-/- DC, sensitive 3 to 24VDC 150, 300mW DC, sensitive 5 to 24VDC 200, 450mW Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Initial surge withstand voltage between open contacts between contact and coil between adjacent contacts Isolation 100/900MHz Insertion loss 100/900MHz Volt. standing wave ratio 100/900MHz Capacitance between open contacts 140 to 175Vrms 500vdc 500vdc max. 1pF 400Vrms 1000Vrms 1500Vp (10/160µs) 500Vrms 1000Vrms 1500Vp (10/160µs) Other Data Ambient temperature (max.) Category of environmental protection Terminal type Dimension (lwh) -20 to +70°C IP67/RTIII THT 40 to +80°C RTIII/IP67 THT 12.5x7.5x10mm -40 to +60°C (standard) RTII, RTIII THT 15.4x10.4x11.2mm Link to datasheet Axicom REED DIP/SIL TSC OUAZ/T81 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers Axicom HF3 High performance RF relay/switch for up to 3GHz Low power consumption ≤70/140 mW 50 and 75Ω version Very small design Axicom HF3S High performance RF relay/switch for up to 3GHz Low power consumption ≤70/140mW 50 and 75Ω version RF power 100W at 2GHz Very small design Axicom HF6 High performance RF relay/switch for up to 6GHz Low power consumption ≤70/ 140mW 50Ω version Very small design Applications Cable modems and linecards/CATV Measurement and test equipment ATE Satellite/audio/video tuners Cable modems and linecards/CATV Measurement and test equipment ATE Satellite/audio/video tuners Measurement and test equipment ATE Wireless base stations and antennas Wireless infrastructure Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Min. recommended contact load Initial contact resistance 1 form C, 1 CO Bridge contacts 250VAC/220VDC 60W/62.5VA/50W (2.5GHz) 100µV/1µA <100mΩ 1 form C, 1 CO Bridge contacts 250VAC/220VDC 60W/62.5VA/50W (2.5GHz) 100µV/1µA <100mΩ 1 form C, 1 CO Bridge contacts 250VAC/220VDC 60W/62.5VA/50W (2.5GHz) 100µV/1µA <100mΩ Coil Data Magnetic system Rated coil voltage Rated coil power DC coil/bistable 1 coil/2 coils Polarized 3 to 24VDC 140mW/70mW/140mW Polarized 3 to 24VDC 140mW/70mW/140mW Polarized 3 to 24VDC 140mW/70mW/140mW Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Initial surge withstand voltage between open contacts between contact and coil between adjacent contacts Capacitance between open contacts 600Vrms 1000Vrms 1000Vp 1500Vp max. 1pF 600Vrms 1000Vrms 1000Vp 1500Vp max. 1pF 600Vrms 1000Vrms 1000Vp 1500Vp max. 1pF Isolation Insertion loss Voltage standing wave ratio (VSWR) -80/-72/-DB45 -0.03/0.12/-0.35dB 1.05/1.15/1.20 -95/-80/-55dB 1.05/1.10/1.25 -80/-60/-30dB 1.05/1.10/1.40 Other Data Ambient temperature (max.) Category of environmental protection Terminal type Dimension (lwh) -55 to +85°C IP67/RTIII SMT 14.6x7.2x10mm -55 to +85°C IP67/RTIII SMT 15x7.6x10.6mm -55 to +85°C IP67/RTIII SMT 15x7.6x10.6mm Link to datasheet Axicom HF3 Axicom HF3S Axicom HF6 Key Features Footprint 2) see footnote below 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers PCB mount not applicable. Visit TE.com for more information PCB mount not applicable. Visit TE.com for more information PCB mount not applicable. Visit TE.com for more information Typical Applications Industrial machinery HVAC Building controls Industrial machinery HVAC Building controls Industrial machinery HVAC Building controls Output Data Load Voltage Repetitive Blocking Voltage Load Current Range Leakage Current (Off-State) On-State Voltage Drop (Max.) Load Power Factor Rating Thermal Resistance, Junction to Case (R0J-C) (Max.) 24 - 280VAC/48 - 660VAC 600VAC/1200VAC 25A/50A/125A 5mA 1.8V 0.5 - 1.0 2.35/0.55/0.35 24 - 280VAC 600VAC 25A/40A 5mA 1.8V 0.5 - 1.0 2.35/0.86 24 - 280VAC 600VAC 10A/25A 5mA 1.6V 0.5 - 1.0 2.4/1.7 Input Data (AC/DC) Control Voltage Range VIN Must Operate Voltage VIN(OP) (Min.) Must release Voltage VIN(REL) (Min.) Input Current 90 - 280VAC/3 - 32VDC 90VAC/3VDC 10VAC/1VDC 2 - 26mA / 3 - 30mA 4 - 15VDC 4VDC 1VDC 15mA @ 8VDC 90 - 280VAC/3 - 32VDC 90VAC/3VDC 10VAC/1VDC 25mA/20mA Dielectric Strength Isolation: 4000Vrms 4000Vrms 4000Vrms Other Data Dimensions Operating Temperature Mounting UL File No 46.5x57.8x43.4mm –30 to +80°C Panel E29244 44.5x57.8x30.15mm –30 to +80°C Panel E29244 45x57.5x36.5mm –30 to +80°C Panel E29244 Link to datasheet Potter & Brumfield SSR Potter & Brumfield SSRD Potter & Brumfield SSRT INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Potter & Brumfield SSR Standard “hockey puck” package Inverse parallel SCR output 240VAC & 480VAC output types Zero voltage and random voltage turn-on versions 4,000Vrms optical isolation Cover design with anti-rotation barriers
1 Form A (SPST-NO)
Potter & Brumfield SSRD Two independent AC output solid state relays Standard “hockey puck” package Inverse parallel SCR output 4000Vrms optical isolation Quick connect style termination
2 Form A (2 SPST-NO)
Potter & Brumfield SSRT Standard “hockey puck” package TRIAC Output 4,000Vrms optical isolation Cover design with anti-rotation barriers 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data.
Relays, Contactors & Circuit Breakers PCB mount not applicable. Visit TE.com for more information PCB mount not applicable. Visit TE.com for more information PCB mount not applicable. Visit TE.com for more information Potter & Brumfield SSRDC Standard “hockey puck” package 200VDC FET output 12A, 25A and 40A load current options 1500VDC optical isolation Cover design with anti-rotation barriers Potter & Brumfield SSRK 10-30A DIN mount Solid State Relay with integrated heat sink Narrow 22.5mm design Inverse parallel SCR output 240VAC & 600VAC output types 4,000Vrms optical isolation Potter & Brumfield SSRM 45A-65A DIN mount Solid State Relay with integrated heat sink 44.5mm design Inverse parallel SCR output 600VAC output type 4,000Vrms optical isolation Typical Applications Material handling Trains Construction equipment Industrial machinery HVAC Building controls Industrial machinery HVAC Building controls Output Data Load Voltage Repetitive Blocking Voltage Load Current Range Leakage Current (Off-State) On-State Voltage Drop (Max.) Load Power Factor Rating Thermal Resistance, Junction to Case (R0J-C) (Max.) 200VDC NA
10 A/25 A/40 A
2.83VDC NA 0.7/0.7/0.5 24 - 280VAC/48 - 660VAC 600VAC/1200VAC 10A/20A/30A 5mA 1.8V/1.6V 0.5 - 1.0 48 - 660VAC 1200VAC 45A/55A/65A 1mA 1.7V 0.5 - 1.0 Input Data (AC/DC) Control Voltage Range VIN Must Operate Voltage VIN(OP) (Min.) Must release Voltage VIN(REL) (Min.) Input Current 3 - 32VDC 3.5VDC 1VDC 30mA 90 - 280VAC/3 - 32VDC 90VAC/3VDC 10VAC/1VDC 7.5mA - 16mA/18 - 30mA 90 - 140VAC/4 - 32VDC 90VAC/3VDC 10VAC/1VDC 15mA/14 - 30mA Dielectric Strength Isolation: 1500VDC 4000Vrms 4000Vrms Other Data Dimensions Operating Temperature Mounting UL File No 45x57.8x43.4mm –30 to +80°C Panel E29244 22.5x82.3x111.5mm –30 to + 80°C Din Rail E29244 22.5x76.2x109.2mm –40 to + 80°C Din Rail E29244 Link to datasheet Potter & Brumfield SSRDC Potter & Brumfield SSRK Potter & Brumfield SSRM 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data.
1.00 (25.4) MAX. .700 (17.8) 1.100 (27.9) 1.70 (43.1) MAX. .050 (1.3) TYP. CONTROL LOAD .100 (2.5) .040 (1.0) DIA.
4 PLACES
.200 (5.1) .300 (7.6) TYP. PIN ASSIGNMENTS: PIN 1: AC LOAD PIN 2: AC LOAD PIN 3: +DC INPUT PIN 4: -DC INPUT .300 (7.6) MAX. Solid State Relays Relays, Contactors & Circuit Breakers INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Key Features Footprint 2) see footnote below Potter & Brumfield SSRA 2A Miniature, SIP Solid State Relay Inverse parallel SCR output 2500Vrms optical isolation 240VAC output Potter & Brumfield SSRC 5A SIP Solid State Relay Inverse parallel SCR output 4000Vrms optical isolation Typical Applications Industrial machinery HVAC Building controls Industrial machinery HVAC Building controls Output Data Load Voltage Repetitive Blocking Voltage Load Current Range Leakage Current (Off-State) On-State Voltage Drop (Max.) Load Power Factor Rating Thermal Resistance, Junction to Case (R0J-C) (Max.) 12 - 280VAC 600VAC 0.1mA 1.5V 0.5 - 1.0 12 - 280VAC/48 - 660VAC 600VAC/1200VAC 0.1mA 1.4V 0.5 - 1.0 Input Data (AC/DC) Control Voltage Range VIN Must Operate Voltage VIN(OP) (Min.) Must release Voltage VIN(REL) (Min.) Input Current 4-10VDC 4VDC 1VDC 15mA 3 - 15VDC 4VDC 1VDC 15mA Dielectric Strength Isolation: 2500Vrms 4000Vrms Other Data Dimensions Operating Temperature Mounting UL File No 24.1x5.1x12.7mm –30 to + 80°C PCB E29244 43.1x7.6x25.4mm –30 to + 80°C PCB E29244 Link to datasheet Potter & Brumfield SSRA Potter & Brumfield SSRC 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
1.35 MAX. (34.3) .700 (17.8) .900 (22.8) 1.70 (43.1) 1.100 (27.9) .200 (5.1) .050 (1.3) .040 (1.0) DIA. .300 (7.6) TYP. .72 (18.3) TYP. 1.6 TYP. (38.1) PIN 1: AC LOAD PIN 2: AC LOAD PIN 3: + DC INPUT PIN 4: – DC INPUT PIN ASSIGNMENTS: 0.4 (10.16) .10 (2.54) 1.2 (30.5) 1.4 (35.6) 1.6 (40.6) 0.7 (17.8) 0.3 (7.62) Solid State Relays Relays, Contactors & Circuit Breakers Key Features Footprint 2) see footnote below Potter & Brumfield SSRF 25A SIP Solid State Relay with integrated heat sink Inverse parallel SCR output 4000Vrms optical isolation Potter & Brumfield IACM Slim Solid State AC Input Module Color coded by function - Yellow 4000V Vrms optical isolation Compatible with 2IO series mounting boards Typical Applications Industrial machinery HVAC Building controls Industrial machinery HVAC Building controls Output Data Load Voltage Repetitive Blocking Voltage Load Current Range Leakage Current (Off-State) On-State Voltage Drop (Max.) Load Power Factor Rating Thermal Resistance, Junction to Case (R0J-C) (Max.) 12 - 280VAC/48 - 660VAC 600VAC/1200VAC 10A (CC)/25A (FAC) 0.1mA 1.6V 0.5 - 1.0 30VDC 50mA 10uA 0.2VDC Input Data (AC/DC) Control Voltage Range VIN Must Operate Voltage VIN(OP) (Min.) Must release Voltage VIN(REL) (Min.) Input Current 3 - 15VDC 4VDC 1VDC 15mA 24VAC/120VAC/240VAC 18VAC/90VAC/280VAC 10VAC/60VAC/60VAC 1-5mA Dielectric Strength Isolation: 4000Vrms 4000Vrms Other Data Dimensions Operating Temperature Mounting UL File No 43.1x22.8x34.3mm –30 to + 80°C PCB E29244 43.5x10.3x25.5mm –30 to 100°C PCB E29244 Link to datasheet Potter & Brumfield SSRF Potter & Brumfield IACM 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers 0.4 (10.16) .10 (2.54) 1.2 (30.5) 1.4 (35.6) 1.6 (40.6) 0.7 (17.8) 0.3 (7.62) 0.4 (10.16) .10 (2.54) 1.2 (30.5) 1.4 (35.6) 1.6 (40.6) 0.7 (17.8) 0.3 (7.62) 0.4 (10.16) .10 (2.54) 1.2 (30.5) 1.4 (35.6) 1.6 (40.6) 0.7 (17.8) 0.3 (7.62) INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Potter & Brumfield OACM Slim Solid State AC Output Module Color coded by function - black 4000Vrms optical isolation Compatible with 2IO series mounting boards Potter & Brumfield IDCM Slim Solid State DC Input Module Color coded by function - white 4000Vrms optical isolation Compatible with 2IO series mounting boards Potter & Brumfield ODCM Slim Solid State AC Output Module Color coded by function - red 4000Vrms optical isolation Compatible with 2IO series mounting boards 2) see footnote below Typical Applications Industrial machinery HVAC Building controls Industrial machinery HVAC Building controls Industrial machinery HVAC Building controls Output Data Load Voltage Repetitive Blocking Voltage Load Current Range Leakage Current (Off-State) On-State Voltage Drop (Max.) Load Power Factor Rating Thermal Resistance, Junction to Case (R0J-C) (Max.) 24 - 280VAC 600VAC 3A/5A 5mA 1.6VAC 30VDC 50mA 10uA 0.2VDC 60VDC 0.5mA 1.5VDC Input Data (AC/DC) Control Voltage Range VIN Must Operate Voltage VIN(OP) (Min.) Must release Voltage VIN(REL) (Min.) Input Current 3 - 8VDC / 3 - 15VDC 3VDC 1VDC 8mA 3 - 32VDC/10 - 60VDC 3VDC/10VDC 1VDC/1VDC 10mA 5VDC/15VDC/24VDC 3VDC/9VDC/18VDC 1VDC 20mA Dielectric Strength Isolation: 4000Vrms 4000Vrms 4000Vrms Other Data Dimensions Operating Temperature Mounting UL File No 43.5x10.3x25.5mm –30 to 100°C PCB E29244 43.5x10.3x25.5mm –30 to 100°C PCB E29244 43.5x10.3x25.5mm –30 to 100°C PCB E29244 Link to datasheet Potter & Brumfield OACM Potter & Brumfield IDCM Potter & Brumfield ODCM 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers Key Features Typical Applications HVAC (Transformers), General Aviation, Medical, Marine Power Supplies, Lighting, Surge Protection Audio, Pool and Spa, Appliances, Industrial Controls Generators, General Aviation, Medical, Marine Power Supplies, Lighting, Surge Protection Audio, Pool and Spa, Appliances, Industrial Controls Operational Data Type Number of Poles Circuit function Ambient temperature (max.) Terminal type Mounting Manual operation Actuator Dimension L*W*H Thermal Series trip -20 to +60 °C Standard quick connect .250in x .032in Snap-in Push-to-reset 39.0 x 15.9 x 13.7mm Thermal Series trip -20 to +65°C #8-32 screw Thru-hole 3/8"-24 threaded bushing Push/pull W23 and toggle W31 40.6x17.5x35.2mm Electrical Data Dielectric strength Insulation Resistance Max Operating Voltages Rated current Interrupt capacity Calibration Resetable Overload Capacity Reset Time 1500Vrms 32VDC 250VAC, 50/60Hz 0.5A to 20A 1,000 amps at 250VAC, 50/60 Hz. and 32VDC in accordance with UL standard 1077. Will continuously carry 100% of rating. 3-20 amp models – may trip between 101% and 134%, but must trip at 135% of rating within one hour at +25°C. 0.25-2 amp models – may trip between 101% and 174%, but must trip at 175% of rating within one hour at +25°C. Six times rated current for 0.25 through 2 amp models. Ten times rated current for 3 through 20 amp models. 180 seconds max. for 0.25 through 2 amp models. 5 to 30 seconds for 3 through 20 amp models. 1500Vrms 50VDC 240VAC to (400Hz) 1A to 50A With 4X Max. Series Fuse Protection 0.5-50 amp models — 1000 amps at 240VAC. 30-50 amp models — 1000 amps at 50VDC. Without 4X Max. Series Fuse Protection 0.5-25 amp models — 2000 amps at 50VDC. 10-20 amp models — 2000 amps at 120VAC Continuously carry 100% of rating, may trip between 101% and 134% of rating at 25°C. Must trip at 135% in one hour. Ten times rated current. Accessories Protective boot, push-on lockwasher Hex nut, lockwasher, knurl nut Link to datasheet Potter & Brumfield W28 Potter & Brumfield W23/W31 Potter & Brumfield W28 Thermal Overload / Trip Free Operation Replaces slow blow glass cartridge fuse and holder Button provides visible trip indication Push-to-reset Snap-in mounting UL 1077, CSA, VDE, CCC (16A/20A not VDE) PCB mount not applicable. Visit TE.com for more information PCB mount not applicable. Visit TE.com for more information Potter & Brumfield W23/W31 Thermal Overload / Trip Free Operation Toggle or Push/Pull Actuation Cannot be reset against overload On/Off switching option UL 1077, CSA 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) Footprint images are representative. For a complete selection, refer to the TE data sheet via the link above.
Relays, Contactors & Circuit Breakers INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Potter & Brumfield W33 Thermal overload/trip free Operation Optional indicator lamp Optional auxiliary switch Combines on/off switching and circuit protection in a single unit UL 1077, CSA Potter & Brumfield W51 Thermal overload/trip free operation Rocker actuated with switch overload sensing Optional indicator lamp Combines power switching and circuit protection in a single unit Compact design PCB termination options UL1077, cUL, VDE, CCC Potter & Brumfield W54 Thermal overload/trip free operation Push to reset Visual trip indication Multiple termination options UL 1077, UL 1500, cUL, VDE, CCC, CSA. (>30A not UL1500 or CSA) (>20A not VDE) Typical applications Generators, General Aviation, Medical, Marine Power Supplies, Lighting, Surge Protection Audio, pool and spa, appliances, Industrial controls Generators, General Aviation, Medical, Marine Power Supplies, Lighting, Surge Protection Audio, pool and spa, appliances, Industrial controls Generators, general aviation, medical, marine Power supplies, lighting, surge protection Audio, pool and spa, appliances, Industrial controls Operational Data Type Number of Poles Circuit function Ambient temperature (max.) Terminal type Mounting Manual operation Actuator Dimension L*W*H Thermal 1-2 Series trip both poles; series trip 1 pole/switch only 1 pole; switch only 2 poles -20 to +65 °C Standard quick connect 250in x .032in and solder option Snap-in Rocker 43.8 x 24.9 x 48.0mm Thermal Series trip 0°C to + 60 °C for 10-20A models 0°C to + 50 °C for 5-8A models Standard quick connect 250inx.032in/solder option/PCB Snap-in, PCB Rocker 21.8 x 15.2 x 32.0mm Thermal Series trip 0 to 60 °C Standard quick connect 250inx.032in and #8-32 screw threaded bushing Push-to-reset 31.0 x 14.6 x 35.0mm (W54) 22.6 x 14.6 x 29.2mm (W57) Electrical Data Dielectric strength Insulation Resistance Max Operating Voltages Rated current Interrupt capacity Calibration Resetable OverloadCapacity Reset Time 2000Vrms 50VDC 250VAC 2A to 20A 1000A at 50VDC, 250VAC/60Hz and 125/250VAC 400Hz; 1500A at 25/250VAC/60Hz Will continuously carry 100% of rating. May trip between 101% and 134%, but must trip at 135% of rating within one hour at +25°C 150% for 5-8A models Ten times rated current 1500VAC 100M Ω 50VDC 125/250VAC (model dependent) 5A to 20A 1,000 amps in accordance with UL standard 1077 Will continuously carry 100% of rating. May trip between 101% and 134%, but must trip at 135% of rating within one hour at +25°C. 150% for 5-8A models Ten times rated current. Switch Endurance Cycling: Typically 6,000 operations at 100% of rating
60 Seconds
100MΩ 50VDC 250VAC 5A to 40A 1,000 amps in accordance with UL standard 1077 Will continuously carry 100% of rating. May trip between 101% and 134%, but must trip at 135% of rating within one hour at +25°C Ten times rated current. Accessories Protective boot, knurl nut, hex nut, lockwasher, nameplate Link to datasheet Potter & Brumfield W33 Potter & Brumfield W51 Potter & Brumfield W54 Key Features PCB mount not applicable. Visit TE.com for more information PCB mount not applicable. Visit TE.com for more information PCB mount not applicable. Visit TE.com for more information 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data.
Relays, Contactors & Circuit Breakers PCB mount not applicable. Visit TE.com for more information PCB mount not applicable. Visit TE.com for more information PCB mount not applicable. Visit TE.com for more information Potter & Brumfield W57 Thermal overload/trip free operation Push to reset Compact design Cannot be manually tripped PCB termination options UL 1077, UL 1500, cUL, VDE, CCC. (3A,4A,20A no VDE) Potter & Brumfield W58 Thermal overload/trip free operation Push to reset Cannot be manually tripped Visual trip indication UL 1077, UL 1500, CSA. (30A not UL or CSA) Potter & Brumfield W6/W9 Magnetic hydraulic actuation/trip-free operation Several delay curve options Fungus and moisture resistant UL 1077, UL 1500, CSA, VDE Applications Generators, general aviation, medical, marine Power supplies, lighting, surge protection Audio, pool and spa, appliances, Industrial controls Generators, general aviation, medical, marine Power supplies, lighting, surge protection Audio, pool and spa, appliances, Industrial controls HVAC (transformers), general aviation, medical, marine Power supplies, lighting, surge protection Audio, pool and spa, appliances, Industrial controls Operational Data Type Number of Poles Circuit function Ambient temperature (max.) Terminal type Mounting Manual operation Actuator Dimension L*W*H Thermal Series trip 0 to 60°C Standard quick connect .250in x .032in and #8-32 screw and PCB option 3/8"-24, M11-1.0, M12-1.0 threaded bushing Push-to-reset 31.0 x 14.6 x 35.0mm (W54) 22.6 x 14.6 x 29.2mm (W57) Thermal Series trip -25 to 65°C Standard quick connect .250in x .032in and #8-32 screw 3/8"-24 threaded bushing" Push-to-reset 34.9 x 16.8 x 34.9mm Magnetic/hydraulic 1-4 Series trip -40 to +85 °C W6-Standard Quick Connect .250in x .032in and #8-32 or #10/32 screw. W9- #10/32 stud terminations 6-32, M3 tapped holes Toggle 41.7 x 19.0 x 50.8mm (W6 per pole) 46.9 x 19.0 x 63.5mm (W9 per pole) Electrical Data Dielectric strength Insulation Resistance Max Operating Voltages Rated current Interrupt capacity Calibration Resetable Overload Capacity Reset Time 1500VAC 50VDC, 250VAC 50/60 Hz 3A to 20A 1000 amps in accordance with UL standard 1077 Will continuously carry 100% of rating. May trip between 101% and 134%, but must trip at 135% of rating within one hour at +25°C Ten times rated current 50VDC, 250VAC 0.5A to 30A 2000 amps at 50VDC (0.5 - 30 amp models) 1000 amps at 250VAC (0.5 - 30amp models). Note: 30 amp model not UL or CSA Breaker will continuously carry 100% of rated load. It may trip between 101% and 145% of rated load, but must trip at 145% at 25°C Ten times rated current 50/60 Hz, 1,500V: DC, 1100V 100 megohms at 500VDC 65VDC, 277VAC, 480VAC - 3Ø wye 0.20A to 50A up to 5000A with UL 1077, CSA, VDE. Up to 3000A for UL 1500 Breakers will hold 100% rated current. May trip between 101% and 124% rated load (134% for AC/DC units) Must trip at 125% rated load (135% for AC/DC units) Ten times rated current Accessories Protective boot, knurl nut, hex nut, lockwasher, nameplate Protective boot, knurl nut, hex nut, lockwasher Toggle guard (W6 only) Link to datasheet Potter & Brumfield W57 Potter & Brumfield W58 Potter & Brumfield W6/W9 Key Features 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data.
Visit TE.com for more information Visit TE.com for more information Transformers Relays, Contactors & Circuit Breakers INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Key Features Typical Applications HVAC Industrial and residential Motor control HVAC Industrial and residential Motor control Specifications Primary Voltage- AC Secondary Voltage- DC Insulation Class Wire Size QC size Terminations Frequency Mounting Options 120, 208, 240, 277, 380, 415, 480, 575 12 or 24 UL Class B (130°C) Standard 18 AWG stranded, 12in N/A Same side - opposite side 50/60 Hz Type K Foot Mount Type G Panel Mount Plate Mount 120, 208, 240, 277, 380, 415, 480, 575 12 or 24 UL Class B (130°C) N/A standard .250in x .032in Type BB Same side Type AB Opposite side Type AE Laydown 50/60 Hz Type K Foot Mount Type G Panel Mount Plate Mount Other Data Secondary Fusing Requirement Shielding Dielectric Strength 60VA-75VA non-inherently energy limited Internal fuse or integral circuit breaker 75VA standard models come with integral circuit breaker Internal fuse or integral circuit breaker 75VA standard models come with integral circuit breaker Link to datasheet 4000 SERIES WIRE LEAD CLASS II CONTROL TRANSFORMERS
4000 SERIES
4000 SERIES WIRE
UL 5085-3, formerly UL 1585 Inherently/non-inherently energy limited Wire lead terminations Custom specification/design available
4000 SERIES QUICK
UL 5085-3, formerly UL 1585 Inherently/non-inherently energy limited Quick connect terminals Custom specification/design available 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data.
Visit TE.com for more information Visit TE.com for more information PAGE 37 Transformers Relays, Contactors & Circuit Breakers Key Features Applications HVAC Industrial Motor control Industrial controls, garage door openers small power supplies, control boards lighting/monitoring controls, vending machines Specifications Primary Voltage- AC Secondary Voltage- DC Insulation Class Wire Size QC size Terminations Frequency Mounting Options 120, 208, 240, 230, 277, 460, 480, 575 UL Class B (130°C) Standard 18 AWG stranded, 12in Standard .250in x .032in Type BB same side Type AB opposite side 50/60 Hz Type K foot mount Single 115VAC, 6-pin Dual 115/230VAC, 8-pin Series 10-120VCT Parallel 6-60VAC UL Class B (130°C) N/A N/A PCB through hole design 50/60 Hz PCB through hole design Other Data Secondary Fusing Requirement Shielding Dielectric Strength Electrostatic shielding not required due to split bobbin 1500Vrms Link to datasheet 4700 SERIES GENERAL PURPOSE POWER TRANSFORMERS
4900 SERIES
4700 SERIES GENERAL PURPOSE
UL 5085-1,-2 formerly UL 50 Non-fused Wire leads or quick connects Custom specification/design available
4900 SERIES PRINTED CIRCUIT
1.1VA to 36VA UL 5085-1,-2 formerly UL 506 Drop in replacement Split bobbin design Signal or dual primary voltage Custom specification/design available 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data.
INDUSTRIAL / / / QUICK REFERENCE GUIDE INDUSTRIAL RELAYS te.com © 2019 TE Connectivity. All Rights Reserved. Axicom, Potter & Brumfield, SCHRACK, TE, TE Connectivity, and TE Connectivity (logo) are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. While TE has made every reasonable effort to ensure the accuracy of the information in this brochure, TE does not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this catalog are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE for the latest dimensions and design specifications. 1-1773969-4 02/20 JN