SCAN18374T FAIRCHILD | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 12
Technical content
Features
I IEEE 1149.1 (JTAG) Compliant I Buffered positive edge-triggered clock I 3-STATE outputs for bus-oriented applications I 9-bit data busses for parity applications I Reduced-swing outputs source 32 mA/sink 64 mA I Guaranteed to drive 50Ω transmission line to TTL input levels of 0.8V and 2.0V I TTL compatible inputs I 25 mil pitch SSOP (Shrink Small Outline Package) I Includes CLAMP and HIGHZ instructions I Member of Fairchild’s SCAN Products Ordering Code: Devices also available in Tape and Reel. Specify by appending the suffix letter “X” to the ordering code. Connection Diagram Pin Descriptions Truth Tables H = HIGH Voltage Level L = LOW Voltage Level X = Immaterial Z = High Impedance /c17 = L-to-H Transition Order Number Package Number Package Description SCAN18374TSSC MS56A 56-Lead Shrink Small Outline Package (SSOP), JEDEC MO-118, 0.300 Wide Pin Names Description AI(0–8), BI(0–8) Data Inputs ACP , BCP Clock Pulse Inputs AOE 1, BOE1 3-STATE Output Enable Inputs AO (0–8), BO(0–8) 3-STATE Outputs Inputs AO (0–8) ACP AOE 1 AI(0–8) XHXZ /c17 LLL /c17 LHH Inputs BO (0–8) BCP BOE 1 BI(0–8) XHXZ /c17 LLL /c17 LHH
www.fairchildsemi.com 2 SCAN18374T Functional Description The SCAN18374 consists of two sets of nine edge-trig- gered flip-flops with individual D-type inputs and 3-STATE true outputs. The buffered clock and buffered Output Enable pins are common to all flip-flops. Each set of the nine flip-flops will store the state of their individual D inputs that meet the setup and hold time requirements on the LOW-to-HIGH Clock (ACP or BCP) transition. With the Output Enable (AOE 1 or BOE1) LOW, the contents of the nine flip-flops are available at the outputs. When the Output Enable is HIGH, the outputs go to the high impedance state. Operation of the Output Enable input does not affect the state of the flip-flops. Logic Diagram Please note that this diagram is provided only for the understanding of logic operations and should not be used to estimate propagation delays. Block Diagrams Byte-A Note: BSR stands for Boundary Scan Register
3 www.fairchildsemi.com SCAN18374T Block Diagrams (Continued) Tap Controller Byte-B Note: BSR stands for Boundary Scan Register
www.fairchildsemi.com 4 SCAN18374T Description of Boundary-Scan Circuitry The scan cells used in the BOUNDARY-SCAN register are one of the following two types depending upon their loca- tion. Scan cell TYPE1 is intended to solely observe system data, while TYPE2 has the additional ability to control sys- tem data. Scan cell TYPE1 is located on each system input pin while scan cell TYPE2 is located at each system output pin as well as at each of the two internal active-high output enable signals. AOE controls the activity of the A-outputs while BOE controls the activity of the B-outputs. Each will acti- vate their respective outputs by loading a logic high. The BYPASS register is a single bit shift register stage identical to scan cell TYPE1. It captures a fixed logic low. Bypass Register Scan Chain Definition Logic 0 The INSTRUCTION register is an eight-bit register which captures the value 00111101. The two least significant bits of this captured value (01) are required by IEEE Std 1149.1. The upper six bits are unique to the SCAN18374T device. SCAN CMOS Test Access Logic devices do not include the IEEE 1149.1 optional identification register. Therefore, this unique captured value can be used as a “pseudo ID” code to confirm that the correct device is placed in the appropriate location in the boundary scan chain. Instruction Register Scan Chain Definition MSB → LSB Scan Cell TYPE1 Scan Cell TYPE2 Instruction Code Instruction
00000000 EXTEST
10000001 SAMPLE/PRELOAD
10000010 CLAMP
00000011 HIGHZ
5 www.fairchildsemi.com SCAN18374T Description of Boundary-Scan Circuitry (Continued) Boundary-Scan Register Scan Chain Definition (42 Bits in Length)
www.fairchildsemi.com 6 SCAN18374T Description of Boundary-Scan Circuitry (Continued) Boundary-Scan Register Definition Index Bit No. Pin Name Pin No. Pin Type Scan Cell Type
41 AOE 1 3 Input TYPE1 Control
Signals40 ACP 54 Input TYPE1
39 AOE Internal TYPE2
38 BOE
37 BCP 31 Input TYPE1
36 BOE Internal TYPE2
0 55 Input TYPE1 A –in
34 AI 1 53 Input TYPE1
33 AI 2 52 Input TYPE1
32 AI 3 50 Input TYPE1
31 AI 4 49 Input TYPE1
30 AI 5 47 Input TYPE1
29 AI 6 46 Input TYPE1
28 AI 7 44 Input TYPE1
27 AI 8 43 Input TYPE1
26 BI 0 42 Input TYPE1 B –in
25 BI 1 41 Input TYPE1
24 BI 2 39 Input TYPE1
23 BI 3 38 Input TYPE1
22 BI 4 36 Input TYPE1
21 BI 5 35 Input TYPE1
20 BI 6 33 Input TYPE1
19 BI 7 32 Input TYPE1
18 BI 8 30 Input TYPE1
17 AO 0 2 Output TYPE2 A –out
16 AO 1 4 Output TYPE2
15 AO 2 5 Output TYPE2
14 AO 3 7 Output TYPE2
13 AO 4 8 Output TYPE2
12 AO 5 10 Output TYPE2
11 AO 6 11 Output TYPE2
10 AO 7 13 Output TYPE2
8B O 0 15 Output TYPE2 B –out 7B O 1 16 Output TYPE2 6B O 2 18 Output TYPE2 5B O 3 19 Output TYPE2 4B O 4 21 Output TYPE2 3B O 5 22 Output TYPE2 2B O 6 24 Output TYPE2 1B O 7 25 Output TYPE2 0B O 8 27 Output TYPE2
7 www.fairchildsemi.com SCAN18374T Absolute Maximum Ratings(Note 1) Recommended Operating Conditions Note 1: Absolute maximum ratings are those values beyond which damage to the device may occur. The databook specifications should be met, with- out exception, to ensure that the system design is reliable over its power supply, temperature, and output/input loading variables. Fairchild does not recommend operation of SCAN circuits outside databook specifications. Supply Voltage (VCC ) −0.5V to +7.0V DC Input Diode Current (IIK) VI = −0.5V −20 mA VI = VCC +0.5V +20 mA DC Output Diode Current (IOK ) VO = −0.5V −20 mA VO = VCC +0.5V +20 mA DC Output Voltage (VO ) −0.5V to VCC +0.5V DC Output Source/Sink Current (IO ) ±70 mA DC V CC or Ground Current Per Output Pin ±70 mA Junction Temperature SSOP +140°C Storage Temperature −65°C to +150°C ESD (Min) 2000V Supply Voltage (VCC ) SCAN Products 4.5V to 5.5V Input Voltage (VI)0 V t o V CC Output Voltage (VO )0 V t o V CC Operating Temperature (TA) −40°C to +85°C Minimum Input Edge Rate ∆V/∆t 125 mV/ns VIN from 0.8V to 2.0V VCC @ 4.5V, 5.5V Symbol Parameter VCC TA = +25°CT A = −40°C to +85°C Units Conditions (V) Typ Guaranteed Limits VIH Minimum HIGH 4.5 1.5 2.0 2.0 V VOUT = 0.1V VIL Maximum LOW 4.5 1.5 0.8 0.8 V VOUT = 0.1V VOH Minimum HIGH 4.5 3.15 3.15 VI OUT = −50 µA Output Voltage 5.5 4.15 4.15 (Note 2) 4.5 2.4 2.4 V VIN = VIL or VIH 5.5 2.4 2.4 I OH = −32 mA 4.5 2.4 V VIN = VIL or VIH 5.5 2.4 I OH = −24 mA VOL Maximum LOW 4.5 0.1 0.1 V I OUT = 50 µA Output Voltage 5.5 0.1 0.1 (Note 2) 4.5 0.55 0.55 V VIN = VIL or VIH 5.5 0.55 0.55 I OL = 64 mA 4.5 0.55 V VIN = VIL or VIH 5.5 0.55 I OL = 48 mA IIN Maximum Input 5.5 ±0.1 ±1.0 µAV I = VCC , GND Leakage Current IIN Maximum Input 5.5 2.8 3.6 µAV I = VCC TDI, TMS Leakage −385 −385 µAV I = GND Minimum Input Leakage 5.5 −160 −160 µAV I = GND IOLD Minimum Dynamic 5.5 94 94 mA V OLD = 0.8V Max IOHD Output Current (Note 3) −40 −40 mA V OHD = 2.0V Min IOZ Maximum Output 5.5 ±0.5 ±5.0 µAV I (OE) = VIL, VIHLeakage Current IOS Output Short 5.5 −100 −100 mA V O = 0V Circuit Current (min) ICC Maximum Quiescent 5.5 16.0 88 µA VO = Open Supply Current TDI, TMS = VCC 5.5 750 820 µA VO = Open TDI, TMS = GND
www.fairchildsemi.com 8 SCAN18374T Note 2: All outputs loaded; thresholds associated with output under test. Note 3: Maximum test duration 2.0 ms, one output loaded at a time. Noise Specifications Note 4: Worst case package. Note 5: Maximum number of outputs that can switch simultaneously is n. (n − 1) outputs are switched LOW and one output held LOW. Note 6: Maximum number of outputs that can switch simultaneously is n. (n − 1) outputs are switched HIGH and one output held HIGH. Note 7: Maximum number of data inputs (n) switching. (n − 1) input switching 0V to 3V. Input under test switching 3V to threshold (VILD). Note 8: Voltage Range 5.0 is 5.0V ± 0.5V. AC Operating Requirements Normal Operation Note 9: Voltage Range 5.0 is 5.0V ± 0.5V. Symbol Parameter VCC TA = +25°CT A = −40°C to +85°C Units Conditions (V) Typ Guaranteed Limits ICCt Maximum ICC 5.5 2.0 2.0 mA V I = VCC − 2.1V Per Input VI = VCC − 2.1V 5.5 2.15 2.15 mA TDI/TMS Pin, Test One with the Other Floating Symbol Parameter VCC TA = +25°CT A = −40°C to +85°C Units (V) Typ Guaranteed Limits VOLP Maximum HIGH Output Noise 5.0 1.0 1.5 V (Note 5)(Note 6) VOLV Minimum LOW Output Noise 5.0 −0.6 −1.2 V (Note 5)(Note 6) VOHP Maximum Overshoot 5.0 V OH +1.0 V OH +1.5 V (Note 4)(Note 6) VOHV Minimum VCC Droop 5.0 V OH −1.0 V OH −1.8 V (Note 4)(Note 6) VIHD Minimum HIGH Dynamic Input Voltage Level 5.5 1.6 2.0 2.0 V (Note 4)(Note 7) VILD Maximum LOW Dynamic Input Voltage Level 5.5 1.4 0.8 0.8 V (Note 4)(Note 7) Symbol Parameter VCC TA = +25°CT A = −40°C to +85°C Units(V) C L = 50 pF C L = 50 pF (Note 8) Min Typ Max Min Max ns tPHL CP to Q 2.5 10.3 2.5 11.5 ns tPHZ 1.5 9.0 1.5 10.0 ns tPZH 2.0 8.9 2.0 9.5 Symbol Parameter VCC TA = +25°CT A = −40°C to +85°C Units(V) C L = 50 pF C L = 50 pF (Note 9) Guaranteed Minimum tS Setup Time, H or L 5.0 3.0 3.0 ns Data to CP tH Hold Time, H or L 5.0 1.5 1.5 ns CP to Data tW CP Pulse Width 5.0 5.0 5.0 ns fMAX Maximum ACP/BCP Clock Frequency 5.0 100 90 MHz
9 www.fairchildsemi.com SCAN18374T Scan Test Operation Note 10: Voltage Range 5.0 is 5.0V ± 0.5V. Note: All Propagation Delays involving TCK are measured from the falling edge of TCK. Symbol Parameter VCC TA = +25°CT A = −40°C to +85°C Units(V) C L = 50 pF C L = 50 pF (Note 10) Min Typ Max Min Max ns tPHL TCK to TDO 3.5 13.2 3.5 14.5 ns tPHZ TCK to TDO 2.5 11.5 2.5 11.9 ns tPZH TCK to TDO 3.0 14.5 3.0 15.8 nstPHL TCK to Data Out 5.0 18.0 5.0 19.8 During Update-DR State nstPHL TCK to Data Out 5.0 18.6 5.0 20.2 During Update-IR State nstPHL TCK to Data Out 5.5 19.9 5.5 21.5 During Test Logic Reset State nstPHZ TCK to Data Out 4.0 16.4 4.0 18.2 During Update-DR State nstPHZ TCK to Data Out 5.0 19.5 5.0 20.8 During Update-IR State nstPHZ TCK to Data Out 5.0 19.9 5.0 21.5 During Test Logic Reset State nstPZH TCK to Data Out 5.0 18.9 5.0 20.9 During Update-DR State nstPZH TCK to Data Out 6.5 22.4 6.5 24.2 During Update-IR State nstPZH TCK to Data Out 7.0 23.8 7.0 25.7 During Test Logic Reset State
www.fairchildsemi.com 10 SCAN18374T AC Operating Requirements Scan Test Operation Note 11: Voltage Range 5.0 is 5.0V ± 0.5V. Note 12: This delay represents the timing relationship between the data Input and TCK at the associated scan cells numbered 0–8, 9–17, 18–26 and 27–35. Note 13: Timing pertains to BSR 38 and 41 only. Note 14: This delay represents the timing relationship between AOE, BOE and TCK at scan cells 36 and 39 only. Note 15: Timing pertains to BSR 37 and 40 only. Note: All Input Timing Delays involving TCK are measured from the rising edge of TCK. Symbol Parameter VCC TA = +25°CT A = −40°C to +85°C Units(V) C L = 50 pF C L = 50 pF (Note 11) Guaranteed Minimum tS Setup Time, H or L 5.0 3.0 3.0 ns Data to TCK (Note 12) tH Hold Time, H or L 5.0 4.5 4.5 ns TCK to Data (Note 12) tS Setup Time, H or L 5.0 3.0 3.0 ns AOE 1, BOE1 to TCK (Note 13) tH Hold Time, H or L 5.0 4.5 4.5 ns TCK to AOE1, BOE1 (Note 13) tS Setup Time, H or L 5.0 3.0 3.0 ns Internal AOE, BOE to TCK (Note 14) tH Hold Time, H or L 5.0 3.0 3.0 ns TCK to Internal AOE, BOE (Note 14) tS Setup Time 5.0 3.0 3.0 ns ACP, BCP (Note 15) to TCK tH Hold Time 5.0 3.5 3.5 ns TCK to ACP, BCP (Note 15) tS Setup Time, H or L 5.0 8.0 8.0 ns TMS to TCK tH Hold Time, H or L 5.0 2.0 2.0 ns TCK to TMS tS Setup Time, H or L 5.0 4.0 4.0 ns TDI to TCK tH Hold Time, H or L 5.0 4.5 4.5 ns TCK to TDI tW Pulse Width TCK 5.0 H 15.0 15.0 ns L5 . 0 5 . 0 fMAX Maximum TCK 5.0 25 25 MHz Clock Frequency Tpu Wait Time, Power Up to TCK 5.0 100 100 ns Tdn Power Down Delay 0.0 100 100 ms
11 www.fairchildsemi.com SCAN18374T Extended AC Electrical Characteristics Note 16: This specification is guaranteed but not tested. The limits apply to propagation delays for all paths described switching in phase (i.e., all LOW-to- HIGH, HIGH-to-LOW, etc.). Note 17: This specification is guaranteed but not tested. The limits represent propagation delays with 250 pF load capacitors in place of the 50 pF load capacitors in the standard AC load. This specification pertains to single output switching only. Note 18: 3-STATE delays are load dominated and have been excluded from the datasheet. Note 19: The Output Disable Time is dominated by the RC network (500Ω , 250 pF) on the output and has been excluded from the datasheet. Note 20: Skew is defined as the absolute value of the difference between the actual propagation delays for any two separate outputs of the same device. The specification applies to any outputs switching HIGH-to-LOW (tOSHL ), LOW-to-HIGH (tOSLH ), or any combination switching LOW-to-HIGH and/or HIGH- to-LOW. Capacitance Symbol Parameter TA = +25°C Units VCC = 5.0V T A = −40°C to +85°C C L = 50 pF V CC = 5.0V ± 0.5V
18 Outputs C L = 250 pF
Switching (Note 17) (Note 16) Min Typ Max Min Max tPLH , Propagation Delay 3.0 11.5 4.0 13.5 ns tPHL Data to Output 3.0 12.5 4.0 16.5 tPZH , Output Enable Time 2.5 10.5 (Note 18) ns tPZL 2.5 tPHZ , Output Disable Time 2.0 10.5 (Note 19) ns tPLZ 2.0 10.5 tOSHL Pin to Pin Skew 0.5 1.0 1.0 ns (Note 20) HL Data to Output tOSLH Pin to Pin Skew 0.5 1.0 1.0 ns (Note 20) LH Data to Output Symbol Parameter Typ Units Conditions C IN Input Pin Capacitance 4.0 pF V CC = 5.0V C OUT Output Pin Capacitance 13.0 pF V CC = 5.0V C PD Power Dissipation Capacitance 34.0 pF V CC = 5.0V
www.fairchildsemi.com 12 SCAN18374T D-Type Flip-Flop with 3-STATE Outputs Physical Dimensions inches (millimeters) unless otherwise noted 56-Lead Shrink Small Outline Package (SSOP), JEDEC MO-118, 0.300 Wide Fairchild does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and Fairchild reserves the right at any time without notice to change said circuitry and specifications. LIFE SUPPORT POLICY FAIRCHILD ’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be rea- sonably expected to result in a significant injury to the user. 2. A critical component in any component of a life support device or system whose failure to perform can be rea- sonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.fairchildsemi.com