SC804A SEMTECH | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 21
Technical content
1 www.semtech.com SC804A Fully Integrated 4.4V Lithium-Ion Battery Charger System with Timer PRELIMINARYPOWER MANAGEMENT July 18, 2007 Typical Application Circuit
Applications
The SC804A is a fully integrated full-feature, single cell constant-current/constant-voltage (CC/CV) 4.4V Lithium- Ion battery charger. With an integrated timer and complete charge control algorithm, the SC804A is ideal for stand-alone charger applications. The SC804A contains programmable pre-charge, fast-charge and termination current settings. The SC804A can be programmed to terminate charging based on the output current or the time-out of the programmable timer. The fast charge current is typically set with an external resistor, but it can also be adjusted by applying an analog voltage to the AFC pin. This feature allows use of a microcontroller to set charging current via a DAC output. The SC804A’s 14V input voltage range eliminates the need for additional protection circuitry required by other 5V chargers to protect against faulty adapters. The SC804A also incorporates an under-voltage lockout falling threshold of 3V so that charging will continue if the input supply goes into a current-limited mode. Reference ground and battery sense inputs are provided to eliminate voltage drops during charging due to high charging currents. The output voltage to the battery is controlled to within 1% of the programmed voltage. The SC804A can also function as a general purpose current source or as a current source for charging nickel-cadmium (NiCd) and nickel-metal-hydride (NiMH) batteries. Typical Application Circuit Fully integrated charger with FET pass transistor, reverse-blocking diode, sense resistor, timer, and thermal protection Battery voltage controlled to 1% accuracy Programmable precharge, fastcharge & termination current over wide range, with analog current control reference input for design fl exibility Up to 1.5A continuous charge current Input voltage range from 3V to 14V Soft-start reduces start-of-charge adapter load transients NTC thermistor sense input and adjustable cold temperature threshold Adjustable 2 - 6 hour programmable charge timer 0.1μA battery drain current in shutdown and monitor modes Small 4mm x 4mm 16 lead MLPQ package Over-current protection in all modes Over-voltage protection Remote Kelvin sensing at the battery terminals Status indicators for charger-present, charger-active, over-voltage fault, and error notifi cation Cellular phones PDAs Handheld meters Charging stations Handheld computers Digital cameras Programmable current source VCC14 OVPB13
3 IPRGM7 NTC
6 GND5 RGND
2.2 μF Battery Red Green Charger VIN RT NTC R1 R2 DAC ISET 2.2μF R5 R6 ERROR OV_FLT
2© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT
Electrical Characteristics
Unless otherwise noted: VCC = 4.75V - 5.25V. Typical values are at TA = 25°C Min and Max are for -40°C < TA < +85°C unless noted. Parameter Symbol Conditions Min Typ Max Units Operating Voltage VCC OP 4.28 5.0 6.22 (1) V VCC UVLO Rising Threshold VT UVLOR Charging begins when threshold is exceeded 3.88 4.08 4.28 V VCC UVLO Falling Threshold VT UVLOF Charging continues until threshold is reached 2.86 3.06 3.26 V VCC OVP Rising Threshold VTOVPR 6.63 6.94 7.40 V VCC OVP Falling Threshold VTOVPF 6.22 6.63 7.00 V VCC OVP Hysteresis VT OVPH 200 350 600 mV Operating Current ICCDIS Shutdown Mode - CHRGB, CPB, OVPB, FLTB off NTC = 0V 1.9 mA ICCCHG Charging Mode - CHRGB, CPB, OVPB, FLTB off NTC = 2.5V 2.0 Exceeding the specifi cations below may result in permanent damage to the device or device malfunction. Operation outside of the parameters specifi ed in the Electrical Characteristics section is not implied. Parameter Symbol Maximum Units VCC, CTO, NTC to GND -0.3 to 14.0 V VOUT, BSEN, RTIM, AFC, IPRGM, CPB, CHRGB, OVPB, ITERM, FLTB, to GND -0.3 to +6.0 V RGND to GND -0.3 to 0.3 V VOUT Output Current I VOUT 1.5 A Power Dissipation MLP (Derate 20mW/°C above 85°C) Pd 2 W Thermal Impedance, Junction to Ambient (1) θJA 48 °C/W Junction Temperature T J 150 °C Operating Ambient Temperature Range T A -40 to +85 °C IR Refl ow Temperature T LEAD 260 °C Storage Temperature Range T STG -65 to 150 °C VOUT short to GND Continuous ESD Protection Level (2) VESD 2k V Absolute Maximum Ratings Notes: 1) Calculated from package in still air, mounted to 3” x 4.5”, 4 layer FR4 PCB with thermal vias under the exposed pad per JESD51 standards. 2) Tested according to JEDEC standard JESD22-A11 4-B.
3© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT Electrical Characteristics (Cont.) Parameter Symbol Conditions Min Typ Max Units Battery Leakage Current (VOUT and BSEN) ILEAKBAT VCC = 0V, VOUT = BSEN = 4.5V 0.1 2 μA Regulated Constant Voltage VCV 0°C ≤ TJ ≤ 125°C 4.314 4.357 4.40 V RGND Output Accuracy VOUT = VOUTNOM + ∆RGND VRGND RGND - GND = 30mV 22 30 38 mV RGND Current I RGND RGND = 0V 35 μA Battery Pre-Charge Current I PREQ RITERM = 499Ω, 0°C ≤ TJ ≤ 125°C 270 300 330 mA Battery Termination Current ITERM RITERM = 499Ω, 0°C ≤ TJ ≤ 125°C 270 300 330 mA Battery Fast-Charge Current IFAST RPRGM = 1.87kΩ, VOUT = 3.8V 0°C ≤ TJ ≤ 125°C 753 815 878 mA AFC DAC Fast-Charge Current IDACADJ RPRGM = 1.87kΩ, V(AFC) = 0.75V 0°C ≤ TJ ≤ 125°C 364 405 447 mA AFC Enable/Disable Threshold VTAFC VCC - VAFC > VTAFC disables Analog Fast Charge 1V ITERM Regulated Voltage VITERM 1.45 1.557 1.66 V IPROG Regulated Voltage VIPRGM 1.45 1.557 1.66 V VBAT Precharge Threshold VTPreQ 0°C ≤ TJ ≤ 125°C 2.9 3.01 3.11 V VBAT Recharge Threshold VTReQ VCV - VBSEN, 0°C ≤ TA ≤ 85°C 60 100 140 mV Over-Temperature Shutdown TOT Hysteresis = 10°C 150 °C
4© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT Electrical Characteristics (Cont.) Parameter Symbol Conditions Min Typ Max Units NTC Thresholds VTNTCDIS SC804A Disabled 0.3 0.6 0.8 V VTNTCH NTC Hot VTH Applies to falling threshold 4.3V ≤ VCC ≤ 6.5V at VCC = 5V 1.45 1.50 1.55 % of VCC V VTNTCC NTC Cold VTH, VCTO = 0V Applies to rising threshold 4.3V ≤ VCC ≤ 6.5V at VCC = 5V 73.4 3.67 74.4 3.72 75.4 3.77 % of VCC V VTNTCHYS NTC Hot & Cold VTNTCx hysteresis (VTNTCx Rising - VTNTCx Falling) Applies to internal NTC thresholds 50 mV VCTO CTO Voltage (Adjustable NTC Cold Rising Threshold) Setting Range(2), -40°C ≤ TA ≤ 25°C (NTC Cold Rising Threshold is VTNTCC when CTO tied to GND) 50 90 % of VCC Threshold Error(3), -40°C ≤ TA ≤ 25°C -70 70 mV VTCTOHYS Internal hysteresis on CTO (VCTO Rising - VCTO Falling) Applies to externally set NTC cold threshold 50 mV Adjust Mode BSEN Voltage V BSEN-ADJ 3.5V ≤ VOUT ≤ VCC - 150mV 0°C ≤ TJ ≤ 125°C 3.189 3.217 3.253 V Adjust Mode Enable Voltage, VOUT-BSEN VADJEN 3.5V ≤ VOUT ≤ VCC - 150mV 400 mV Adjust Mode Disable Voltage, VOUT-BSEN VADJDIS 3.5V ≤ VOUT ≤ VCC - 150mV 150 mV External RTIM Regulation Voltage VRTIM RRTIM = 37.4kΩ 1.450 1.557 1.660 V Timer Disable Threshold VTTIMER VRTIM ≤ VTTIMER disables internal timer 0.65 0.85 V Internal Timer Select VT INTTS VCC-VRTIM > VTINTTS selects internal timer 1.1 V
5© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT Electrical Characteristics (Cont.) Parameter Symbol Conditions Min Typ Max Units Pre-Charge Fault Time-out TPreQF RRTIM = 37.4kΩ RTIM pulled to VCC -20% -35% +20% +35% min Complete Charge Time-out TQCOMP RRTIM = 37.4kΩ RTIM pulled to VCC -20% -35% 3.37 2.89 +20% +35% hr CHRGB On V CHRGB Load = 5mA 0.5 1 V CHRGB Off I CHRGB Leakage Current, V = 5V 1 μA CPB On V CPB Load = 5mA 0.5 1 V CPB Off I CPB Leakage Current, V = 5V 1 μA OVPB On V OVPB Load = 5mA 0.5 1 V OVPB Off I OVPB Leakage Current, V = 5V 1 μA FLTB On V FLTB Load = 5mA 0.5 1 V FLTB Off I FLTB Leakage Current, V = 5V 1 μA Notes: 1) VCC_OP Max is the “Maximum Vsupply” as defi ned in EIA/JEDEC Standard No. 78, paragraph 2.11. 2) The absolute voltage on CTO must not exceed 6.0V to ensure normal operation. 3) The threshold error is tested at VCTO min and max only.
6© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT DEVICE PACKAGE SC804AMLTRT(1) MLPQ -16(2) SC804EVB Evaluation Board (2) Pin Descriptions Pin Confi guration Notes: 1) Available in tape and reel packaging only. A reel contains 3000 devices. 2) Available in lead-free packaging only. This product is fully WEEE and RoHS compliant.Pin # Pin Name Pin Function 1 BSEN Battery voltage sense. Connect to battery positive terminal for Kelvin voltage sensing, VOUT otherwise. Do not leave open. 2C T O Cold Temperature Offset. Adjustable NTC input high voltage (cold temperature) threshold. When the pin is connected to GND the NTC high voltage threshold defaults to VTNTCC×VVCC. 3 IPRGM Charger current program pin for fast-charge mode. Requires a resistor to GND to program fast-charge current. 4 ITERM Charger termination current program pin. Requires a resistor to GND to program pre-charge and termination current. 5 RGND Reference ground. Connect to battery’s negative terminal for Kelvin voltage sensing, GND otherwise. Do not leave open. 6 GND Ground.
7 NTC
Input for battery NTC thermistor network. Voltage between VT NTCH×VVCC, normally the hot threshold, and the CTO voltage (VTNTCC×VVCC if CTO is tied to GND), normally the cold threshold, enables charging. Voltages outside this range suspend charging and drive FLTB pin active (low). Voltage below VTNTCDIS (nominally 0.6V) disables the SC804A and resets the charge timer (with FLTB pin inactive). 8 FLTB Open drain fault indicator. Active low when a fault condition occurs. 9 AFC Analog Fast Charge input. Connect to a DAC for analog control of fast charge current level, connect to VCC to disable this feature. Do not leave open. 10 CHRGB Open drain charge status indicator. Active low when the charger is on and the output current exceeds the termination current setting, high impedance when IVOUT < ITERM. 11 CPB Open drain charger-present indicator. Active low when VCC exceeds UVLO.
12 RTIM
Programmable timer input pin. Connect to VCC to select the default time-out of 3 hrs., connect to GND to disable timer, or connect an external resistor to GND to program the time-out period. 13 OVPB Open drain over-voltage indicator. Active low when an input over-voltage fault occurs. 14 VCC Input supply pin. Connect to adapter power. 15 VOUT Charger output. Connect to battery. 16 VOUT Charger output. Connect to battery. T THERMAL PAD Thermal-conduction pad on bottom of the package. Solder directly to the ground plane with multiple thermal vias to all other ground planes.
Ordering Information
MLPQ16: 4X4 16 LEAD T VOUT VCC VOUT OVPB RGND GND NTC FLTB AFC CHRGB CPB RTIMBSEN CTO IPRGM ITERM
7© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT Block Diagram Figure 1 - SC804A Functional Block Diagram Reference Voltages 11 13 VOUT IPRGM ITERM GND NTC CHRGB CPB RGND VCV (VBSEN-ADJ in Adj. Mode) Fast-Charge Ref NTC Interface Pre - Charge Ref RTIM Control Timer Pre-Charge On Fast-Charge On Over-Temp Under-Voltage Over-Voltage
14 VCC
16 VOUT
8 FLTB
8© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT Fast-Charge Mode (CC) The fast-charge CC (Constant Current) mode is active when the battery voltage is above VT PreQ and less than VCV. The fast-charge current can be set to a maximum of 1.5A and is selected by the program resistor on the IPRGM pin. The voltage on this pin will represent the current through the battery, enabling a microprocessor via an analog-to-digital converter (ADC) to monitor battery current by sensing the voltage on the IPRGM pin. The equation to set the fast- charge current is given by: The superior fast-charge current accuracy of the SC804A is obtained by use of a patented* polarity-switched (i.e., chopped) current sense ampli fi er to nullify current measurement offset errors. Compliance with the absolute maximum output current I VOUTMAX, allowing for current regulation tolerance, requires that RIPRGM be no smaller than 1.05kΩ nominal. RIPRGM can be as large as 12.1kΩ, for a nominal FCI as small as 130 mA, but must exceed PCI by at least 80mA. Note that for a given program resistor the current into the battery in CV mode can be determined by replacing V IPRGM_Typ with the actual voltage on the IPRGM pin in the above equation. The CC current can also be modifi ed by applying an analog voltage to the AFC pin as described below. Analog Fast Charge (AFC Pin) Many applications require more than one current setting for fast-charge. This behavior is obtained in the SC804A using the AFC function. When the AFC pin is connected to VCC the device behaves as described in the previous section. When the AFC pin is driven by an analog voltage between 0V and (V VCC-1.0)V, the SC804A automatically uses this pin voltage to set the maximum fast-charge current according to the following equation: This adjustment to the fast charge current is obtained by replacing the fi xed V IPRGM reference voltage with the General Operation The SC804A can be confi gured independently with respect to fast-charge and termination current, output voltage, and timing, depending on the application. A typical charging cycle is described below. Details on alternative applications and output programmability are covered in the individual sections. The charging cycle begins when the power adapter is connected to the device. The SC804A performs glitch fi ltering on the VCC input and initiates a charge cycle when V VCC is greater than the under-voltage lockout (UVLO) rising threshold voltage. If the battery voltage is less than the pre-charge threshold level, the SC804A will output the pre-charge current. Once the pre-charge threshold voltage is exceeded, the SC804A enters fast-charge constant current (CC) mode. When the battery voltage reaches its fi nal value, the charger enters the constant voltage (CV) mode. In this mode the output current decreases as the battery continues to charge until the termination current level is reached. The CHRGB output turns off when IOUT drops below the termination current. If the charge timer is active, the SC804A continues to hold the battery in CV charge mode until the timer expires. When the timer expires the charger enters the monitor mode where the output remains off until the voltage at VOUT drops by VT ReQ. At this point a new charge cycle is initiated. Pre-Charge Mode Pre-charge mode is automatically enabled whenever the battery voltage is below the pre-charge threshold voltage, VT PreQ. It is used to limit the power dissipation and precondition the battery for fast charging. The pre-charge current value is determined by the resistor on the ITERM pin. The pre-charge current is programmable from 50mA to 350mA. The equation to select the pre-charge current is given by: where V ITERM_Typ designates the typical value of VITERM. When the timer is enabled there is also a maximum allowed pre- charge duration. If the pre-charge time exceeds 25% of the total charge cycle the charger will turn off due to a pre-charge fault. This fault is cleared when VCC is toggled or the output voltage rises above VT PreQ. Applications Information PCI = VITERM_Typ × 100 RITERM FCI = VAFC × 1000 RIPRGM *US Patent 6,836,095. × 1000 FCI = RIPRGM VIPRGM_Typ
9© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT in the event of a faulty battery and to maximize charging capacity. The RTIM pin is connected to VCC to select the internal timer, and to GND to disable the timer. Connecting a resistor between RTIM and GND will program the total charge time according to the following equation: R RTIM 3.08 3600 With charge time expressed in hours. The timer is programmable over the range of 2 to 6 hours. The internal timer selection results in a charge time of 3 hours. The SC804A will automatically turn off the output when the charge timer times out. NTC Interface The NTC pin provides an interface to a battery pack Negative Temperature Coeffi cient (NTC) thermistor. The typical NTC network has a fi xed resistor from VCC to the NTC pin, and the battery pack NTC thermistor connected from the NTC pin to ground. In this con fi guration, an increasing battery temperature produces a decreasing NTC pin voltage, and a decreasing battery temperature produces an increasing NTC pin voltage. This con fi guration is shown in the typical application schematic on page 1 of this datasheet. When the NTC voltage from the divider is greater than the high (cold) threshold or less than the low (hot) threshold, the SC804A suspends the charge cycle by turning off the output, halting (but not resetting) the charge timer, and indicating a fault on the FLTB pin. Hysteresis is included for both high and low NTC thresholds to avoid chatter at the NTC trip points. When the NTC pin voltage returns to the valid range, the SC804A automatically resumes the charge cycle. The charge timer will time-out when the SC804A output on- time exceeds the timer setting regardless of how long it has been disabled due to the NTC temperature. An input voltage between VTNTCH×VVCC and the CTO input voltage VCTO ( VTNTCC×VVCC if CTO is tied to GND) enables charging. An input voltage outside this range suspends charging and drives FLTB pin active (low). The internal NTC thresholds of VTNTCH and VTNTCC were designed to work with standard thermistors available from numerous vendors. NTC pin voltage below VT NTCDIS (nominally 0.6V) disables Applications Information (Cont.) AFC voltage. (Note that AFC voltages above V IPRGM will produce IVOUT exceeding that programmed as per the Fast- Charge Mode (CC) section.) For any applied AFC voltage, FCI must not drop below 130mA, and FCI must always remain at least 80mA greater than PCI. Termination Current Once the battery voltage reaches V CV the SC804A will transition from constant current mode to constant voltage mode. The current through the battery will decrease while the voltage remains constant as the battery becomes fully charged. When the current falls below the programmed termination current set by the termination resistor connected to the ITERM pin, the SC804A will disable CHRGB. If the timer is enabled the output will continue to fl oat-charge in CV mode until the timer expires. If the timer is disabled, the output will turn off as soon as the termination current level is reached. The equation to set the termination current is given by: ITERM can be programmed to be as high as 300mA or as low as 50mA, though accuracy is not guaranteed below 100mA. ITERM must be programmed to be less than FCI for correct operation of the charge cycle. Monitor Mode When a charge cycle is complete, the SC804A output turns off and the device enters monitor mode. If the voltage of the battery falls below the recharge threshold CV - V ReQ), the charger will clear the charge timer and re-initiate a charge cycle. The maximum current drain of the battery during monitor mode will be no more than 1μA over temperature. The status of the charger output as a function of the timer and IOUT is tabulated below. Charge Timer The timer on the SC804A has two functions: to protect Timer Iout Output State T < Timeout N/A On T > Timeout N/A Off Disabled < Itermination Off VITERM_Typ ITERM = × 100RITERM
10© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT or R3 = 2.333×RHOT = 13.624kΩ exactly. The closest 1% standard nominal value is R3 = 13.7kΩ. Step 2: Verify acceptable thermistor self heating. In general, lower values of RT provide more noise immunity for the NTC voltage, but at the expense of bias current from the input adapter and power dissipation in the NTC network. The dissipation constant is the power rating of the thermistor resulting in a 1 oC self heating error. The greatest self-heating occurs at low thermistor resistance (at high temperature). Since temperature sensing accuracy matters only at the charging temperature range thresholds, self heating is assessed only at the worst case high temperature threshold of +40 oC. For V VCC = 5V, the 40 oC NTC network current I NTC_HOT = VVCC /(R3 + R HOT) = 0.246mA. Power dissipation in the thermistor at this temperature, P HOT = R HOT × (I NTC_HOT)2 = 0.38mW, for self heating of approximately 0.13 oC. The actual high temperature threshold will thus be lower by 0.13 oC. This self-heating error is usually acceptable. If it is not, then a thermistor with a greater R HOT must be chosen. Step 3: Determine the desired high (cold) threshold . Compute the NTC network resistor divider voltage, as a function of V VCC, at the cold temperature threshold. Step 4: Confi gure CTO. If NTCCOLD is suf fi ciently close to the default cold threshold ( VTNTCC×VVCC), then simply connect CTO to ground, disabling the CTO function, to complete the design. But in this example it is not, so the voltage on CTO must be set to 0.6591×V VCC. The simple resistive voltage divider network of Figure 2 can be used to obtain the desired CTO voltage. or Applications Information (Cont.) the SC804A and resets the charge timer (with the FLTB pin inactive). The NTC pin can be pulled down to ground by an external n-channel FET transistor or processor GPIO to disable or reset the SC804A. Note that the response of the SC804A to NTC pin voltage above the high threshold and below the low threshold is the same. Thus it is possible to con fi gure the NTC network with the battery pack thermistor between NTC and VCC, and a fi xed resistor between NTC and ground. This confi guration may be useful if it is desired to reset the charge timer (and the CHRGB output) when the battery pack is removed (so the fi xed resistor pulls the NTC pin to ground) while VCC is present. Cold Temperature Offset (CTO) The voltage applied to the CTO pin sets the NTC high voltage (normally the cold temperature threshold) for the NTC input. The default NTC high threshold ( VTNTCC×VVCC) can be selected by connecting the CTO pin to ground. If it is desired to change this threshold, the voltage on the CTO pin can be set between 0.5×V VCC and 0.9×VVCC. This feature is especially useful if a single PCB design is needed to satisfy similar applications with different requirements. The temperature range for normal charging can be adjusted by adjusting resistor values on a divider network without changing the NTC thermistor, which is often enclosed in the battery pack. An example of a typical application is shown in Figure 2. NTC/CTO Design Example The following example assumes the NTC network confi guration of Figure 2, with a fi xed resistor R3 connected between NTC and VCC, and a battery NTC thermistor RT connected between NTC and ground. The battery temperature range over which charging is permitted is oC through 40 oC. The datasheet for the selected NTC thermistor indicates that RT = 5.839k Ω at 40oC, at RT = 26.49kΩ at 0oC, with a dissipation constant DC = 3mW. Designate RHOT = 5.839kΩ and RCOLD = 26.49kΩ. Step 1: Select R3. For the normal (NTC thermistor to ground) con fi guration, solve the NTC network voltage divider for R3 to place the NTC voltage at 0.3×VCC when RT = R HOT. 0.3 × VCC = VCC × RHOT R3 + RHOT NTCCOLD = VCC × RCOLD = 0.6591 × VCC R3 + RCOLD VCTO = NTCCOLD = 0.6591 × VCC = VCC × RCT2 RCT1 + RCT2 RCT1 = 1 0.6591 = 0.5172 RCT2 0.6591
11© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT Applications Information (Cont.) The choice of R CT1 and R CT2 is somewhat arbitrary. The simplest approach is to pick one and compute the other. A good choice here is R CT1 = 115kΩ, and RCT2 = 221kΩ, as these standard 1% tolerance values produce the closest match to the desired voltage divider ratio. With these resistor nominal values, which is, nominally, only 0.2% below the target value of 0.6591×V VCC. The CTO network will present a load of only 15μA to a 5V charging adapter. The nominal impedance presented to the CTO pin is R CT1 || R CT2 = 75.6k Ω. Any impedance on the order of 100kΩ (or less) is acceptable. Remote Kelvin Sensing at the Battery The BSEN pin provides the positive Kelvin sensing voltage feedback to the CV amplifi er and should be connected as close to the battery + terminal as possible. Likewise, the RGND pin should be connected directly to the negative terminal of the battery. This allows the designer great fl exibility in PCB layout and achieves greater accuracy by sensing the battery voltage directly at the battery terminals. When laying out the PCB, the designer should route the BSEN and RGND trace directly to the battery connection terminals, rather than just to the VOUT and GND pins on the device. Dropout Voltage Dropout voltage is the smallest achievable difference voltage between VCC and VOUT under a particular operating condition. Dropout voltage is encountered during CC charging whenever the current limit of the charging adapter is less than the SC804A FCI programmed current. In this case, the adapter voltage (the SC804A input voltage) will be pulled down to the battery voltage (the SC804A output voltage) plus the dropout voltage. Dropout voltage is the larger of two values: (1) the I-R component, which is the output current multiplied by the minimum VCC-to-VOUT path resistance (which is highly temperature dependent), and (2) a regulated minimum difference voltage, which is output voltage dependent but is independent of the output current. The regulated minimum dropout voltage results from the collapse of internal voltage references as VOUT pulls VCC down to near, or below, V CV, creating a reduced output regulation voltage approximately 200mV below VCC. Thus VCC cannot be pulled down below VOUT + 200mV. The dropout voltage will be larger than 200mV whenever the minimum path resistance multiplied by the output current exceeds 200mV, but it cannot be smaller than 200mV. This greatest-of-two-limit dropout voltage behavior is evident in the dropout voltage typical performance plot. When operating in Adjust Mode (next section), the regulated minimum dropout voltage depends on the programmed VOUT regulation voltage, and dropout also varies with the actual output voltage during CC charging. See Figure 4 for an illustration of dropout voltage data. Adjust Mode The SC804A can be con fi gured for an output voltage other than V CV using Adjust (ADJ) Mode. In Adjust Mode the output voltage is determined by an external resistor divider from VOUT to BSEN. When BSEN is connected in this fashion, V VOUT (during Constant Voltage (CV) charging) will be controlled such that the voltage at the BSEN pin BSEN) is the reference voltage VBSEN-ADJ. The output voltage can be set to any voltage desired by an appropriate choice of divider network resistors, within the following limits. When the SC804A is programmed for adjust mode, V VOUT is required to be 150mV less than VVCC, and VVOUT is required to be 400mV greater than VBSEN. VVOUT within 150mV of V BSEN guarantees normal mode operation. This implies that, for BSEN used as a Kelvin sense of battery voltage, the product of the fast charge current and the charge path resistance from VOUT to the Kelvin sense point should not exceed 150mV to ensure normal mode operation. The SC804A Adjust Mode schematic is shown in Figures 3a and 3b. Referring to these schematics, the equation for setting the output voltage is: The capacitor C3 across R8 in the feedback network introduces zero-pole frequency compensation for stability. Place the zero according to the following equation to ensure stability: VCTO = VCC × RCT2 = 0.6577 × VCC RCT1 + RCT2 R11 × C3 = 1 2 × 100kHz VOUT = VBSEN-ADJ_TYP x ( 1 + R11 ) R12
12© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT VCC14 OVP13 2.2 μF R3 Red Green Charger VIN RT NTC R1 R2 2.2μF R5 R6 ERROR RCT1 RCT2 OV_FLT VCC14 OVP13 2.2 μF R3 Red Green Charger VIN RT NTC R1 R2 2.2μF R5 R6 ERROR R11 R12 OV_FLT VCC14 OVP13 2.2 μF R3 Red Green Charger VIN RT NTC R1 R2 2.2μF R4 R5 R6 ERROR R11 R12 OV_FLT Applications Information (Cont.) Figure 2 - Application Circuit with AFC Disabled, and with NTC and CTO Resistor Networks Figure 3a - Application Circuit for Adjust Mode Figure 3b - Application Circuit for Adjust Mode, with Adapter-only Voltage Sensing
13© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT The actual dropout voltage is the greater of the Minimum Dropout Voltage at various programmed V CV and instantaneous VOUT voltages (shown here, with several programmed V CV voltages indicated in the fi gure by ‘o’), and the IR drop due to the product of IOUT and R DS-ON (not shown here). Adjust mode operation is ensured for any IOUT current at programmed V CV voltages up to approximately 4.41V. Applications Information (Cont.) FLAG ON OFF CPB UVLO < VCC < OVP Input out of range CHRGB IOUT > ITERM IOUT < ITERM OVPB VCC > OVP VCC < OVP FLTB VCC > OVP VCC UVLO NTC Temp Fault Pre-Charge Time-out (OT (Tj > 150°C) Normal Operation or NTC Disable NOTE: When using Adjust Mode to program a CV regulation voltage greater than V CV, care must be taken when CC charging with a charging adapter operating in current limit. Adapter current-limited operation occurs when the adapter current limit is less than the programmed SC804A fast charge current, such that the adapter voltage is pulled down to V VOUT plus the SC804A dropout voltage. A low adapter current limit multiplied by the low minimum path resistance of the main pass transistor and current sense resistor (as low as 290m Ω total at extremely low temperature) can result in a voltage drop from VCC to VOUT of less than 150mV if the Adjust Mode CV regulation voltage is programmed above V CV + 50mV. If V VCC - V VOUT < 150mV, Adjust Mode may not operate correctly. Adjust Mode will operate correctly whenever the programmed VOUT CV voltage is less than V CV + 50mV, regardless of the adapter current limit, because the regulated minimum dropout voltage is always greater than 150mV in this case. It will also operate correctly with an adapter current limit greater than 550 mA, regardless of the programmed output voltage, because the I-R dropout voltage will exceed 150mV at even the lowest speci fi ed operating temperature. Normal mode (that is, not Adjust Mode) has a regulated minimum dropout voltage of approximately 200mV, which is constant for any V VOUT, and so operates correctly for any adapter current limit. Overcurrent and Max Temperature Protection Overcurrent protection is inherent in all modes of operation. When the device is in charge mode the output is current- limited to either the pre-charge current limit value or the fast charge current limit value depending on the voltage at the output. Max die temperature protection is also included. This feature allows the SC804A to operate with maximum power dissipation by disabling the output current when the die temperature reaches the maximum operating temperature. The result is that the SC804A will operate as a pulse charger in extreme power dissipation applications, delivering the maximum allowable output current while regulating the internal die temperature to a safe level. Indicator Flags There are four indicator outputs/LED drivers ont he SC804A; CPB (Charger Present), CHRGB (Charge Active), OVPB (Over Voltage Fault), and FLTB (Fault). These outputs are all active-low; open drain NMOS drivers capable of sinking up to 10mA. The following table de fi nes each indicator’s output state. The CPB output can be used as a VCC-present indicator. Regardless of teh state of NTC, the CPB output re fl ects the VCC voltage. When V CC is between the UVLO and OVP thresholds the CPB output is low. If V CC is outside these limits, this output is high impedance. The CHRGB output indicates the charging status. When the output current is greater than ITERM, CHRGB is low. CHRGB is high impedance when IOUT is less than ITERM. The CHRGB output is latched during the charge cycle when the output current is less than ITERM. This latch is reset when the battery enters a recharge cycle, or if NTC or VCC are toggled. 0.2 0.4 0.6 0.8 Output voltage, V Minimum dropout voltage, V Figure 4 - Adjust Mode Minimum Dropout Voltage
14© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT Charge Mode Timing Diagram VCC VOUT IOUT CPB CHRGB TIMER FLTB NTC UVLO VTPreQ Pre-Charge Soft Start Fast Charge Termination Current Re-Charge Threshold CC Mode CV Mode On On On On On On On Off Off Off Off Off Fault Hold Figure 5 - Charge Mode Timing The OVPB signal is an active-low output that signals when the input voltage exceeds the OVP threshold. When the voltage on VCC is less than the OVP threshold voltage this output is high impedance. The FLTB output is activated when the device experiences a fault condition. This output can be used to notify the system controller of a fault condition when connected to an interrupt input, or it can be used like CPB and CHRGB to drive an indicator LED. There are fi ve fault modes signaled by FLTB: input over-voltage, input under-voltage, NTC temperature out of range, max die temperature (OT), and pre-charge timeout. When any of these conditions occurs the FLTB output goes low; otherwise it remains high impedance. Capacitor Selection Low cost, low ESR ceramic capacitors such as the X5R and X7R dielectric material types are recommended for use with the SC804A. The output capacitance range is 1μF to 4.7μF. The input capacitor is typically between 0.1μF to 2.2μF, but larger values will not degrade performance
15© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT State Diagram Over-Voltage, Under-Voltage or Over-Temperature will force the SC804A into Shutdown Mode from any state. Soft Start CC Mode Yes IOUT = IFAST Yes IOUT < ITERM VOUT < VCV -V ReQ low temp > NTC Temp > high temp Yes Yes Yes Yes Start Timer Start CV Mode Timer Enabled? CC = Constant Current CV = Constant Voltage Yes Yes OVP > VCC > UVLO En = Hi Soft Start Vout CHRGB Low Timer Enabled? Start Pre-C h a r g e IOUT = IPREQ Time > TMAX/4 Pre- Charge Timeout Fault FLTB goes low. Cleared by VBAT > VTPreQ or Re- cycle VCC Yes VOUT = VCV CHRGB High Z Monitor Mode VOUT off Time > TMAX Float Charge Mode VOUT = VCV NTC out of Range Fault FLTB goes active low Timer is frozen Charge resumes when NTC Temperature is valid VOUT > VTPreQ Shutdown Mode: VOUT & IOUT off, CHRGB High Z, CPB Low.
16© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT Typical Charge Cycle Typical Charge Cycle Evaluation Board confi gured for internal timer, 1.5V on IPRGM = 843mA, 1.5V on ITERM = 300mA, VCC = 5.0V, Li-Ion battery capacity = 850mAh. A 237Ω load resistor (18mA at a battery voltage of 4.36V) was applied to the battery fol- lowing completion of precharge, to slowly discharge the battery following charge timer timeout to illustrate a recharge cycle. The alphabetic markers indicate the following: (a) precharge; (b) fast charge, or Constant Current (CC) charg- ing; (c) Constant Voltage (CV) charging; (d) termination; (e) CV (“fl oat”) charging until charge timer timeout; (f) charge timer timeout; (g) discharge of the battery due to 18mA load; (h) recharge cycle initiated when battery voltage drops below the recharge threshold. 0 30 60 90 120 150 180 210 240 270 300 330 360 0.5 1.5 2.5 3.5 4.36 0 30 60 90 120 150 180 210 240 270 300 330 360 100 200 300 400 500 600 700 800 900 Time (minutes) IVOUT mA V BATTERY , VCHRGB, (V) Time (minutes) b a c d e f g h a b c f h
17© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT VOUT VCV Line Regulation vs. Load, T = +25°C VOUT V CV Load Regulation vs. Line, T = +25°C VOUT VCV Regulation vs. Temperature, VCC = 5.0V, IOUT = 800mA IOUT Line Regulation vs. Temperature, RPRGM = 1.87kΩ IOUT vs. IPRGM Resistance, T = +25°C Precharge and Termination Current vs. ITERM Resistance Typical Characteristics 4.338 4.340 4.342 4.344 4.346 4.348 4.350 4.352 4.354 4.356 500 750 1000 1250 1500 IOUT (mA) VOUT (V) VCC = 5.0V VCC = 5.5V VCC = 6.0V VCC = 6.5V 4.348 4.350 4.352 4.354 4.356 4.358 4.360 -50 -25 0 25 50 75 100 Ambient Temperature, °C VOUT,V 816 820 824 828 832 836 840 VCC, V IOUT, mA T = +85°C T = +25°C T = -40°C 4.338 4.340 4.342 4.344 4.346 4.348 4.350 4.352 4.354 4.356 VIN (V) VOUT (V) Iout = 500mA Iout = 750mA Iout = 1000mA Iout = 1500mA 400 600 800 1000 1200 1400 1600 1800 1/Riprgm, 1/k IOUT, mA 0.0 50.0 100.0 150.0 200.0 250.0 300.0 350.0 400.0 0 0.5 1 1.5 2 2.5 1/RIPRGM, 1/k IOUT, mA Ω Ω
18© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT Typical Characteristics (Cont.) Dropout Voltage vs. IOUT Rds-on vs. IOUT AFC Operation, RPRGM = 1.87kΩ Rds-on (Ω) 0.100 0.200 0.300 0.400 0.500 0.600 0.700 0.800 0.900 400 600 800 1000 1200 1400 1600 IOUT (mA) Dropout (V) TJ = - 40°C TJ = +25°C TJ = +85°C TJ = +125°C 0.270 0.320 0.370 0.420 0.470 0.520 0.570 0.620 400 600 800 1000 1200 1400 1600 IOUT (mA) TJ = -40°C TJ = +25°C TJ = +85°C TJ = +125°C 200 400 600 800 1000 1200 0 0.5 1 1.5 2 VAFC, V Iout (mA) AFC Pin Tied to VCC Actual AFC Response Ideal AFC Response
19© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT Evaluation Board Schematic Evaluation Board Gerber Plot,Top/Bottom Views D1D1 1 2 390 390 D4D4 1 2 390 390 1GNDGND 1RGNDRGND 1 2 390 390 R15 37.4k R15 37.4k CHARGER+CHARGER+ BSEN1 CTO2 IPRGM3 ITERM4 RGND5 GND6 CPB 11 RTIM 12 OVPB 13 VCC 14 VOUT 15 VOUT 16 CHRGB 10 NTC7 AFC 9 FLTB8 SC804A SC804A 1ITERMITERM 1 2 390 390 RTIMRTIM 1GNDGND 1 2 <NM> <NM> 1CTOCTO 1 2 10k 10k JP5JP5 R11 R11 <NM> <NM> R14 R14 1 2 <NM> <NM> 2.2u 2.2u 1VOUTVOUT 1 2 R13 100k R13 100k R16 POT_3296W-105 R16 POT_3296W-105 1 2 2.2u 2.2u NTCNTC 1 2 JP4JP4 1 2 JP6JP6 1GNDGND 1 2 JP2JP2 D3D3 R12 <NM> R12 <NM> 1 2 JP1JP1 1 2 JP7JP7 1IPRGMIPRGM R10 <NM> R10 <NM> 1.87k 1.87k CHARGER-CHARGER- 1 2 JP3JP3 D2D2 499 499
20© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT INDICATOR (LASER MARK) PIN 1 DIMENSIONS NOM INCHES N bbb aaa DIM L e E D A b MIN MAX MILLIMETERS MINMAX NOM .003 .010 .079 .012 .085 .000 .031 (.008) 0.08 0.30 .014 .089 0.25 2.00 .040 .002 0.00 0.80 2.25 0.35 2.15 0.05 1.00 (0.20) .004 0.10 2.00 2.15 2.25 0.65 BSC.026 BSC .089.085.079 D/2 A LxN bbb C A B bxN e SEATING PLANE C E/2 N e/2 aaa C CONTROLLING DIMENSIONS ARE IN MILLIMETERS (ANGLES IN DEGREES). COPLANARITY APPLIES TO THE EXPOSED PAD AS WELL AS THE TERMINALS. NOTES: AD E B Outline Drawing - MLPQ-16 Marking Information 804A yyww xxxxx xxxx yyww = Date Code (Example: 0552) xxxxx xxxx = Semtech Lot Number (Example: E9010 01-1)
21© 2005 Semtech Corp. www.semtech.com SC804A PRELIMINARYPOWER MANAGEMENT DRAFT Land Pattern - MLPQ-16 Semtech Corporation Power Management Products Division
200 Flynn Road, Camarillo, CA 93012
Phone: (805) 498-2111 FAX (805)498-3804 Contact Information P Y K C Z P Y X G K H .189 .026 .016 .033 .122 .091 .091 4.80 0.40 0.85 0.65 2.30 2.30 3.10 DIM (3.95) MILLIMETERS DIMENSIONS (.156) INCHES THIS LAND PATTERN IS FOR REFERENCE PURPOSES ONLY. CONSULT YOUR MANUFACTURING GROUP TO ENSURE YOUR COMPANY'S MANUFACTURING GUIDELINES ARE MET. NOTES: 2x GH2x (C) 2x Z X