Features
- Low Forward Voltage Drop
- Low Leakage Current
- Excellent High Temperature Stability
- Patented Super Barrier Rectifier Technology
- Soft, Fast Switching Capability
- 175ºC Operating Junction Temperature
- Lead Free Finish, RoHS Compliant (Note 2)
- Also Available in Green Molding Compound (Note 5) Mechanical Data
- Case: TO-220AB
- Case Material: Molded Plastic. UL Flammability Classification Rating 94V-0
- Terminals: Matte Tin Finish annealed over Copper Lead Frame. Solderable per MIL-STD-202, Method 208
- Polarity: As Marked on Body
- Ordering Information: See Page 2
- Marking Information: See Page 2
- Weight: 1.85 grams (approximate) Maximum Ratings (Per Leg) @TA = 25°C unless otherwise specified Single phase, half wave, 60Hz, resistive or inductive load. For capacitance load, derate current by 20%. Characteristic Symbol Value Unit Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage VRRM VRWM VRM 200 V Average Rectified Output Current Per Device (Per Leg) ( T o t a l ) IO 30 60 A Non-Repetitive Peak Forward Surge Current 8.3ms Single Half Sine-Wave Superimposed on Rated Load I FSM 250 A Thermal Characteristics (Per Leg) Characteristic Symbol Value Unit Typical Thermal Resistance Thermal Resistance, Junction to Case (Note 3) Thermal Resistance, Junction to Ambient (Note 3) RθJC RBB θJA 1.2 8.4 ºC/W Operating and Storage Temperature Range TJ, TSTG -65 to +175 ºC Electrical Characteristics (Per Leg) @TA = 25°C unless otherwise specified Characteristic Symbol Min Typ Max Unit Test Condition Forward Voltage Drop VF - 0.91 0.74 0.96
0.77 V I
F = 30A, TJ = 25ºC IF = 30A, TJ = 125ºC Leakage Current (Note 1) IR - 10 100 μA mA VR = 200V, TJ = 25ºC VR = 200V, TJ = 125ºC Reverse Recovery Time trr - 38 50 ns IF = 0.5A, IR = 1A, IRR = 0.25A - 25 35 IF = 1A, VR = 30V di/dt = 100A/μs, TJ = 25ºC Notes: 1. Short duration pulse test used to minimize self-heating effect. 3. Device mounted on heatsink (Black Aluminum, 50mm x 37mm x 15mm) TO-220AB Top View Package Pin Out Configuration TO-220AB Bottom View
Document number: DS31243 Rev. 4 - 2 2 of 3 www.diodes.com December 2009 © Diodes Incorporated SBR60A200CT SBR is a registered trademark of Diodes Incorporated. 0.001 0.01 0.1 100 0.0001 0.001 0.01 0.1 0 30 60 90 120 150 180 V , INSTANTANEOUS REVERSE VOLTAGE (V)R I , INSTANTANEOUS REVERSE CURRENT (mA)R T = -55°CA T = 2 5 ° CA T = 8 5 ° CA T = 125°CA T = 1 7 5 ° CA 25 50 75 100 125 150 175 40I A V E RAGE FORWARD CURRENT (A)F(AV), T , CASE TEMPERATURE ( C) Fig. 3 Forward Current Derating Curve A ° R = R Per Element θθJA JC R = R Total Device θθJA JC R = 8 ° C / W Per Element θJA Note 3 Ordering Information (Notes 4 & 5) Part Number Case Packaging SBR60A200CT TO-220AB 50 pieces/tube SBR60A200CT-G TO-220AB 50 pieces/tube 5. For Green Molding Compound version part numbers, add "-G" suffix to part number above. Examples: SBR60A200CT-G. Marking Information SBR60A200CT = Product Type Marking Code AB = Foundry and Assembly Code YYWW = Date Code Marking YY = Last two digits of year (ex: 07 = 2007) WW = Week (01-52) 60A200CT YYWW AB SBR
Document number: DS31243 Rev. 4 - 2 3 of 3 www.diodes.com December 2009 © Diodes Incorporated SBR60A200CT SBR is a registered trademark of Diodes Incorporated. Package Outline Dimensions IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries rese rve the right to make modifications, enhanc ements, improvements, corrections or ot her changes without further notice to this document and any product descri bed herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or an y product described herein; neither does Di odes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or us er of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthoriz ed sales channel. Should Customers purchase or use Diodes Inco rporated products for any unintended or una uthorized application, Customers shall i ndemnify and hold Diodes Incorporated and its representativ es harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical component s in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when proper ly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support dev ice or system whose failure to perform can be reasonably expect ed to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifi cations of their life support dev ices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or s ystems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporate d and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2009, Diodes Incorporated www.diodes.com TO-220AB Dim Min Typ Max A 3.56 - 4.82 A1 0.51 - 1.39 A2 2.04 - 2.92 b 0.39 0.81 1.01 b2 1.15 1.24 1.77 c 0.356 - 0.61 D 14.22 - 16.51 D1 8.39 - 9.01 e 2.54 e1 5.08 E 9.66 - 10.66 H1 5.85 - 6.85 L 12.70 - 14.73 L1 - - 6.35 P 3.54 - 4.08 Q 2.54 - 3.42 All Dimensions in mm A A1 c D E L b P H1Q A2e SEATING PLANE 16.00 0.20*± *Guaranteed by TO-220AB leadframe design