SBL1060CTP
Document overview
- Manufacturer or author: Diodes Incorporated
- PDF pages: 4
Technical content
Features
Low Forward Voltage Drop Soft, Fast Switching Capability Schottky Barrier Chip ITO-220S Heat Sink Tab Electrically Isolated from Cathode UL Approval in Accordance with UL 1557, Reference No. E94661 Mechanical Data Case: ITO-220S Case Material: Molded Plastic, UL Flammability Classification Rating 94V-0 Terminals: Matte Tin Finish annealed over Copper leadframe. Solderable per MIL-STD-202, Method 208 Weight: 1.335 grams (approximate) Ordering Information (Note 1) Part Number Case Packaging SBL1060CTP ITO-220S 50 pieces/tube Notes: 1. For packaging details, go to our website at http://www.diodes.com. Marking Information Package Pin Out Configuration Anode Common Cathode Anode Isolated Top View Bottom View SBL1060CTP = Product Type Marking Code AB = Foundry and Assembly Code YYWW = Date Code Marking YY = Last two digits of year (ex: 08 = 2008) WW = Week (01 - 53) 1 0 6 0 C T P Y Y W W AB S B L PART OBSOLETE – NO ALTERNATE PART
Document number: DS31458 Rev. 8 - 4 2 of 4 www.diodes.com October 2015 © Diodes Incorporated SBL1060CTP OBSOLETE – PART DISCONTINUED Maximum Ratings (Per Leg) @TA = 25°C unless otherwise specified Single phase, half wave, 60Hz, resistive or inductive load. For capacitance load, derate current by 20%. Characteristic Symbol Value Unit Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage VRRM VRWM VRM 60 V Average Rectified Output Current (Per Leg) (Total) IO 5 10 A Non-Repetitive Peak Forward Surge Current 8.3ms Single Half Sine-Wave Superimposed on Rated Load IFSM 110 A Isolation Voltage From Terminal Heatsink t = 1 min. VAC 2000 V Thermal Characteristics (Per Leg) Characteristic Symbol Value Unit Typical Thermal Resistance Junction to Case RJC 3 C/W Operating and Storage Temperature Range TJ, TSTG -65 to +150 ºC Electrical Characteristics (Per Leg) @TA = 25°C unless otherwise specified Characteristic Symbol Min Typ Max Unit Test Condition Forward Voltage Drop VF - 0.57 0.7
0.62 V IF = 5A, TJ = 25ºC
IF = 5A, TJ = 125ºC Leakage Current (Note 2) IR - 0.5 50 mA VR = 60V, TJ = 25ºC VR = 60V, TJ = 100ºC Notes: 2. Short duration pulse test used to minimize self-heating effect. 0 300 600 900 0.01 0.1 I , INSTANTANEOUS FORWARD CURRENT (A)F Fig. 1 Typical Forward Characteristics V , INSTANTANEOUS FORWARD VOLTAGE (mV)F T = 25°CA T = -55°CA T = 85°CA T = 125°CA T = 150°CA 0 10 20 30 40 50 60 Fig. 2 Typical Reverse Characteristics V , INSTANTANEOUS REVERSE VOLTAGE (V)R 100 1,000 10,000 100,000I , INSTANTANEOUS REVERSE CURRENT (µA)R T = 25°CA T = 85°CA T = 125°CA T = 150°CA
Document number: DS31458 Rev. 8 - 4 3 of 4 www.diodes.com October 2015 © Diodes Incorporated SBL1060CTP OBSOLETE – PART DISCONTINUED Fig. 3 Forward Current Derating Curve T , AMBIENT TEMPERATURE (°C)A 25 50 75 100 125 150 175 I , AVERAGE FORWARD CURRENT (A)F(AV) R = R Total Device JA JC R = 23°C/W Per Element JA Package Outline Dimensions ITO-220S DIM. MIN. MAX. TYP. A 4.52 4.62 4.57 A1 0.51 1.39 A2 2.57 2.77 2.67 b 0.72 0.95 0.84 b2 1.15 1.54 1.26 c 0.356 0.61 D 14.22 16.51 15.00 D1 8.60 8.80 8.70 D2 13.68 14.08 e 2.49 2.59 2.54 e1 4.98 5.18 5.08 E 10.01 10.21 10.11 E1 6.86 8.89 H1 5.85 6.85 L 13.30 13.90 13.60 L1 4.00 P 3.54 4.08 Q 2.54 3.42 All Dimensions in mm E L be A D
7 Ref
5 Ref
E15 Ref c e1 Q ØP
1.7 Ref
5 Ref5 Ref
Ø1.5 Dp 0.1 max
Document number: DS31458 Rev. 8 - 4 4 of 4 www.diodes.com October 2015 © Diodes Incorporated SBL1060CTP OBSOLETE – PART DISCONTINUED IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF ME RCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability aris ing out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any lic ense under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such appli cations shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companie s whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify an d hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising ou t of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. This document is written in English but may be translated into multiple languages. Only the English version of this document is the final and determinative format released by Diodes Incorporated. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or system s without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expe cted to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support d evices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety -critical, life support devices or systems, notwithstanding any dev ices- or systems -related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorpora ted and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2015, Diodes Incorporated www.diodes.com