Power distribution system SBG-1170-05-V0060 www.e-t-a.de 1617

Description

The power distribution system has been designed to accommodate plug-in type thermal circuit breakers type 1170-21, 1180 and 1610. It is a printed circuit board module for rail mounting. Typical appli- cations are mainly in control cabinets for utility vehicles and special vehicles and for mobile construction machinery. The current supplied by a power supply is distributed onto 5 ways/ slots. There are two LEDs per circuit breaker. The red LED is lighted when the circuit breaker has tripped. The green LED is lighted when the circuit breaker is in ON condition. Group signalling is generated via the distributor. This signal can be enquired via a potential-free relay. The jumpers allow bridging the signalling for individual circuit breakers if those are not fitted. l Ease of cable management, reduced weight l The circuit breakers can be plugged in in OFF condition with the system live l One red and/or green LED per circuit breaker (ON/OFF) l Potential-free group signalling l Signalling can be bridged with a jumper in the event of empty slots l Other population versions available upon request Technical Data Preferred types SBG-1170-05-V0060-B With signalling (relay) with green and red LED, 24 V DC SBG-1170-05-V0060-D With signalling (relay) with green and red LED, 12 V DC Dimensions including circuit breakers 121 x 92.3 x 66.2 bis 94 mm (l x w x h) Rated voltage: 12 V DC / 24 V DC Supply: 75 A spring-loaded terminal, a second terminal allows looping through Load terminals: 5 ways per max. 25 A 3 spring-loaded terminals per way Group signalling: changeover contact 0.5 A (12 V DC / DC 24 V) spring-loaded terminals Temperature range: -20 ... +70 °C pcb protected against condensation by surface coating Derating table temperature ambient 60 °C 70 °C supply 75 A 60 A 50 A load output 25 A 18.5 A 16 A Note l The circuit breakers must only be plugged in or removed in the OFF condition. l The max. supply current of the individual printed circuit boards has to be observed when looping through several distribution modules. l The LEDs and the signalling require a mass potential (0 V), max. 2 A connected via spring-loaded terminals up to 2.5 mm² (1.5 mm² with wire end ferrule with plastic collar), a second terminal allows looping through. l Circuit breakers are not included in delivery.

Ordering information

1170 thermal circuit breaker Version, max. number of circuit breakers on the power distribution system 05 number of slots

0060 Ausführung

A Version A with signalling, red LED, 24 V DC B Version B with signalling, green and red LED, 24 V DC C Version C without signalling, without LED 12 V DC / 24 V DC D Version D with signalling, green and red LED, 12 V DC SBG-1170-05-V0060-A example Overview of connections (terminals) Model terminals supply terminals load terminals signalisation SBG-1170-05-V0060- A/B/C/D Federkraft up to 16 mm² (10 mm² with wire end ferrule with plastic collar) up to 6 mm² (4 mm² with wire end ferrule with plastic collar) up to 2.5 mm² (1.5 mm² with wire end ferrule with plastic collar)

www.e-t-a.de Power distribution system SBG-1170-05-V0060 1617 Dimensions Plug-in modules (circuit breakers) have to be ordered separately. load terminals supply plus jumper supply Gnd (0 V) signal terminal LED red/green symmetrical rail EN50022-35 x 7.5 (not part of the product) type 1180: 94 mm type 1170: 89.3 mm type 1610-H: 73.6 mm type 1610...: 68.2 mm 92.3 mm 121 mm Schematic diagram -F1 GN 12 34 5 11 14 12 1214 RD GN RD GN RD GN RD GN RD -F2 -F3 -F4 -F5