Technical content
www.cynergy3.com © 2012 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited. ISO9001CERTIFIED SB20 Level controller or power interface module with alarm sounder Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate Wimborne, Dorset BH21 7PE Telephone +44 (0) 1202 897969 Email:sales@cynergy3.com The SB20 is a versatile level control or interface module that can also be used in many other process control applications. Power supply 240/415 Vac. Two outputs: Main output SPCO 20(8) Amps 250V Secondary output SPCO 10(4) Amps 250V LED indicator and beeper for low level alarm One level switch can be connected for an alarm or two level switches to start and stop a submersible pump or a solenoid valve for emptying/filling function It works with all kind of level switches, including conductive probes, as well as pressure switches or other limit switches. The module can be used as a dry-running protection, with a pressure switch or filling level control switch, to start and stop a pump. Mechanical Diagram Terminal Assignment 240 or 415Vac supply Other versions can be made for particular applications. Please contact Cynergy3 with your requirements.
2 SPCO relay outputs
Alarm indicator LED and Beeper 1 2 3 4 5 6 7 8 9 10 11 12 24 23 22 21 20 19 18 17 16 15 14 13 SB20 53 mm 90 mm
1 Supply Neutral
3 Supply Live 240Vac
4 Supply Live 415Vac
9 Output 1 nc contact
10 Output 1 no contact
11 Output 1 common
13 Output 2 no contact
14 Output 2 common
15 Output 2 nc contact
19-20 Low voltage input sensor 21-22 Sensor common input
23 Sensor minimum level
24 Sensor maximum level
Low voltage input 19-20 for pressure/float switch with contacts closed at minimum pressure or level switch with contacts closed when level low. NB These terminals must be bridged if no sensor is connected. CEON - OFF 1, 2 or 3 sensor inputs Primary output can directly control motors up to 2HP cosF 0.4-0.5 single phase Technical Specification Supply Voltage V 240 or 415ac Sensor Voltage V 12Vac Sensor Inputs switch contacts or conductive probes Output ratings Output 1 Output 2 Contact Form SPCO SPCO Switching Power Max ac VA 1500 750 Switching Voltage AC Max V 250 250 Switching Voltage DC Max V 28 not approved Switching Current Max Resistive (n/o contact) A 20 10 Standard Parts Inputs Outputs SB20 1, 2 or 3 2 Switching Power Max dc W 560 not approved (n/c contact) A 10 10 Switching Current Max Inductive A 8 4
1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 24 23 22 21 20 19 18 17 16 15 14 13 24 23 22 21 20 19 18 17 16 15 14 13 Secondary or Alarm circuit NC Common Common nc nc no no www.cynergy3.com © 2012 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited. ISO9001CERTIFIED Rainwater tank Supply tank Centrifugal pump To process Supply pipe Solenoid valve Mains water Pump Top tank switch (NC when level low) High level switch (NC when level high) High level switch (NC when level high) Example: Rainwater supply Filling a vented roof tank from a rainwater tank. The pump will operate when the roof tank level is not at max level and the water in the rainwater tank is above the low level. The red alarm LED will illuminate and the Beeper will sound (with switch in ON position), if the level in the rainwater tank drops to the low level, and the secondary relay opens a solenoid valve to supply water from the mains water supply, which will remain operated until the rainwater tank fills to the high level. The Beeper alarm will, if switch is ON, sound until the tank is full. The illustration is for 240Vac supply, which is connected to terminals 0 (neutral) and 3 (live). Example: Process supply Maintaining a pressurised supply to a process. The pump will operate when the pressure switch is below the set level and the water in the supply tank is above the low level. The red alarm LED will illuminate and the Beeper will sound (with switch in ON position), if the level in the supply tank drops to the low level, and the secondary relay will operate. The alarm will remain operated until the tank fills to the high level. The illustration is for 240Vac supply, which is connected to terminals 0 (neutral) and 3 (live). The Beeper alarm will, if switch is ON, sound until the tank is full. Low level switch (NC when level high) Low level switch (NC when level high) X The SB20 can be used for many process control functions, including: Dry running control with 2 level switches Dry running control with 1 level switch Dry running control with conductive probes Pump control by pressure switch Pump control by level switch “No water” alarm and secondary control output Level controller or power interface module with alarm sounder SB20 SB20 CE CE ON - OFF ON - OFF Pressure switch Expansion vessel NB The diagrams shown above are simplified illustrations of how the module may be used and do not include any necessary safety devices, such as fuses or thermal cutouts, or statutory requirements for installation of such electrical equipment.