SARA-U2 U-BLOX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 57

Technical content

Datasheet sections

  • 1 Functional description
  • 1.1 Overview
  • 1.2 Product features
  • 1.3 Block diagram
  • 1.4 Product description
  • 1.5 AT command support
  • 1.6 Supported features
  • 2 Interfaces
  • 2.1 Power management
  • 2.1.1 Module supply (VCC)
  • 2.1.2 RTC supply (V_BCKP)
  • 2.1.3 Generic digital interfaces supply (V_INT)
  • 2.2 Antenna
  • 2.2.1 Antenna RF interface (ANT)
  • 2.2.2 Antenna detection (ANT_DET)
  • 2.3 System functions
  • 2.3.1 Module power-on
  • 2.3.2 Module power-off
  • 2.3.3 Module reset
  • 2.4 SIM
  • 2.4.2 SIM card detection (SIM_DET)
  • 2.5 Serial interfaces
  • 2.5.1 Asynchronous serial interface (UART)
  • 2.5.2 Auxiliary asynchronous serial interface (AUX UART)
  • 2.5.3 Universal Serial Bus (USB)
  • 2.5.4 DDC (I
  • 2.6 Audio
  • 2.7 GPIO
  • 3 Pin definition
  • 3.1 Pin assignment
  • 4 Electrical specifications
  • 4.1 Absolute maximum rating
  • 4.1.1 Maximum ESD
  • 4.2 Operating conditions
  • 4.2.1 Operating temperature range

HSPA modules with 2G fallback Data Sheet Abstract Technical data sheet describing SARA-U2 series HSPA cellular modules. These modules are a complete and cost efficient 3.75G solution offering up to five -band high -speed HSPA and up to quad-band GSM/EGPRS voice and/or data transmission technology in a compact form factor. www.u-blox.com UBX-13005287 - R17

SARA-U2 series - Data Sheet UBX-13005287 - R17 Page 2 of 57 Document Information Title SARA-U2 series Subtitle HSPA modules with 2G fallback Document type Data Sheet Document number UBX-13005287 Revision and date R17 31-Oct-2017 Disclosure restriction Product Status Corresponding content status Functional Sample Draft For functional testing. Revised and supplementary data will be published later. In Development / Prototype Objective Specification Target values. Revised and supplementary data will be published later. Engineering Sample Advance Information Data based on early testing. Revised and supplementary data will be published later. Initial Production Early Prod. Information Data from product verification. Revised and supplementary data may be published later. Mass Production / End of Life Production Information Final product specification. This document applies to the following products: Name Type number Modem version Application version PCN reference Product status SARA-U201 SARA-U201-03B-00 23.60 A01.01 UBX-16018086 Initial Production SARA-U201-63B-00 23.62 A01.01 UBX-17053345 Initial Production SARA-U201-04B-00 23.60 A01.06 UBX-17058162 Initial Production SARA-U201 ATEX SARA-U201-03X-00 23.60 A01.01 UBX-16030157 Initial Production SARA-U201-04X-00 23.60 A01.06 UBX-17058162 Initial Production SARA-U260 SARA-U260-00S-01 23.20 A01.01 UBX-15013844 Mass Production SARA-U260-03S-00 23.41 A01.01 UBX-15020745 Mass Production SARA-U270 SARA-U270-00S-00 23.20 A01.00 UBX-14015739 Obsolete SARA-U270-00S-01 23.20 A01.01 UBX-16006754 Mass Production SARA-U270-03S-00 23.41 A01.01 UBX-15020745 Mass Production SARA-U270-73S-00 23.41 A01.02 UBX-16028821 Mass Production SARA-U270-53S-00 23.41 A01.03 UBX-16008757 End of Life SARA-U270-53S-01 23.41 A01.04 UBX-17011151 Mass Production SARA-U270 ATEX SARA-U270-00X-00 23.20 A01.00 UBX-14015739 Mass Production SARA-U280 SARA-U280-00S-00 23.28 A01.00 UBX-15011634 Mass Production SARA-U280-03S-00 23.41 A01.01 UBX-15020745 Mass Production u-blox reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or any part thereof without the express permission of u-blox is strictly prohibited. The information contained herein is provided “as is” and u-blox assumes no liability for the use of the information. No warranty, either express or implied, is given, including but not limited, with respect to the accuracy, correctness, reliability and fitness for a particular purpose Copyright © 2017, u-blox AG u-blox is a registered trademark of u -blox Holding AG in the EU and other countries. Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. All other registered trademark s or trademarks mentioned in this document are property of their respective owners.

SARA-U2 series - Data Sheet UBX-13005287 - R17 Contents Page 4 of 57

4.2.11 DDC (I

SARA-U2 series - Data Sheet UBX-13005287 - R17 Functional description Page 5 of 57

1 Functional description

1.1 Overview

The SARA-U2 series modules are a 3.75G UMTS/HSPA solution with GSM/(E)GPRS fall -back in the miniature (26.0 x 16.0 mm, 96-pin) SARA LGA form fa ctor that allows seamless drop -in migration from / to other u-blox cellular modules families. SARA-U2 modules feature HSPA data -rates of 7.2 Mb/s (downlink) and 5.76 Mb/s (uplink). The modules offer data and voice communication over an extended operating t emperature range of –40 °C to +85 °C, with low power consumption and a rich feature set including dual-stack IPv4 / IPv6. The SARA-U2 series includes variants supporting band combinations for worldwide operation, for North America operation and for operation in Europe, Asia and other countries. Cost-saving UMTS-only variant is also available. SARA-U2 modules are complete, fully qualified and certified solutions, which reduce costs and enable short time to market. They are ideally suited to M2M applications such as: mobile Internet terminals, car infotainment and telematics, Automatic Meter Reading (AMR), Remote Monitoring Automation and Control (RMAC), surveillance and security, road pricing, asset tracking, fleet ma nagement, anti-theft systems, and Point of Sales (PoS) terminals. SARA-U2 modules support full access to u-blox GNSS receivers via serial port. Thus any host processor connected to the cellular module through a single serial port can control both the cellu lar module and the positioning chip/module. The compact SARA 26.0 x 16.0 mm form factor with LGA pads (functionally, referred to as “pins”) allows fully automated assembly with standard p ick & place and reflow soldering equipment for cost-efficient, high-volume production.

1.2 Product features

Module UMTS Bands Interfaces Audio Features Grade HSUPA [Mb/s] HSDPA [Mb/s] 3G bands [MHz] 2G bands [MHz] UART USB 2.0 DDC (I GPIO Analog Audio Digital Audio Network indication Antenna supervisor Jamming detection Embedded TCP / UDP Embedded HTTP, FTP Embedded SSL / TLS GNSS via Modem AssistNow Software CellLocate FW update via serial FOTA eCall / ERA-GLONASS ODIS Dual stack IPv4/IPv6 Standard Professional Automotive SARA-U201 5.76 7.2 800/850/900 1800/1900 2

  • • • SARA-U201 ATEX 5.76 7.2 800/850/900 1800/1900 2
  • • • SARA-U260 5.76 7.2 850/1900 850/1900 1 1 1 9 1 • • • • • • • • • • • SARA-U270 5.76 7.2 900/2100 900/1800 SARA-U270 ATEX 5.76 7.2 900/2100 900/1800 1 1 1 9 1 • • • • • • • • • • • • Table 1: SARA-U2 series main features summary Second UART interface and FOTA not supported by "03" and "63" product versions SARA-U270-73S and SARA-U270-53S module product versions do not support 2G radio access technology SARA-U270-73S and SARA-U270-53S module product versions do not support 2G radio access technology SARA-U201 ATEX and SARA-U270 ATEX modules provide the sa me feature set as the SARA-U201 and SARA-U270 modules respectively, with the additional certification for use in potentially explosive atmospheres. Unless otherwise specified, SARA-U201 refers to all SARA-U201 ATEX and SARA-U201 modules; in the same way SARA-U270 refers to both SARA-U270 ATEX and SARA-U270 modules.

SARA-U2 series - Data Sheet UBX-13005287 - R17 Functional description Page 6 of 57

1.3 Block diagram

V_BCKP (RTC) V_INT (I/O) RF transceiver Power Management Cellular BaseBand Processor ANT VCC (Supply) USB DDC (I2C) / AUX UART SIM card detection SIM UART Power-On Reset Digital audio (I2S) GPIO Antenna detection

26 MHz

Figure 1: SARA-U201 block diagram Memory V_BCKP (RTC) V_INT (I/O) RF transceiver Power Management Cellular BaseBand Processor ANT VCC (Supply) USB DDC (I2C) SIM card detection SIM UART Power-On Reset Digital audio (I2S) GPIO Antenna detection 3G PA Figure 2: SARA-U260 and SARA-U270 block diagram Memory V_BCKP (RTC) V_INT (I/O) RF transceiver Power Management Cellular BaseBand Processor ANT VCC (Supply) USB DDC (I2C) SIM card detection SIM UART Power-On Reset Digital audio (I2S) GPIO Antenna detection 3G PA Figure 3: SARA-U280 block diagram

SARA-U2 series - Data Sheet UBX-13005287 - R17 Functional description Page 7 of 57

1.4 Product description

SARA-U2 series modules provide variants to support different band combinations for specific regions:  SARA-U201 modules are designed for worldwide operation  SARA-U260 and SARA-U280 modules are mainly designed for operation in America  SARA-U270 modules are mainly designed for operation in Europe, Asia and other countries 3G UMTS/HSDPA/HSUPA characteristics 2G GSM/GPRS/EDGE characteristics Class A User Equipment Class B Mobile Station 3GPP Release 7 High Speed Packet Access (HSPA) UMTS Terrestrial Radio Access (UTRA) Frequency Division Duplex (FDD) 3GPP Release 7 Enhanced Data rate GSM Evolution (EDGE) GSM EGPRS Radio Access (GERA) Time Division Multiple Access (TDMA) Band support:  SARA-U201: Band 19 (800 MHz) Band 5 (850 MHz) Band 8 (900 MHz) Band 2 (1900 MHz) Band 1 (2100 MHz) Band support:  SARA-U201: GSM 850 MHz E-GSM 900 MHz DCS 1800 MHz PCS 1900 MHz  SARA-U260 and SARA-U280: Band 5 (850 MHz) Band 2 (1900 MHz)  SARA-U260: GSM 850 MHz PCS 1900 MHz  SARA-U270: Band 8 (900 MHz) Band 1 (2100 MHz)  SARA-U270: E-GSM 900 MHz DCS 1800 MHz WCDMA/HSDPA/HSUPA Power Class  Power Class 3 (24 dBm) for WCDMA/HSDPA/HSUPA mode GSM/GPRS Power Class  Power Class 4 (33 dBm) for GSM/E-GSM bands  Power Class 1 (30 dBm) for DCS/PCS bands EDGE Power Class  Power Class E2 (27 dBm) for GSM/E-GSM bands  Power Class E2 (26 dBm) for DCS/PCS bands PS (Packet Switched) data rate  HSUPA category 6, up to 5.76 Mb/s UL  HSDPA category 8, up to 7.2 Mb/s DL  WCDMA PS data, up to 384 kb/s DL/UL PS (Packet Switched) data rate  GPRS multi-slot class 12 , CS1-CS4 up to 85.6 kb/s DL/UL  EDGE multi-slot class 12 , MCS1-MCS9 up to 236.8 kb/s DL/UL CS (Circuit Switched) data rate  WCDMA CS data, up to 64 kb/s DL/UL CS (Circuit Switched) data rate  GSM CS data, up to 9.6 kb/s DL/UL supported in transparent/non transparent mode Table 2: SARA-U2 series 3G and 2G characteristics Not supported by SARA-U270-73S, SARA-U270-53S and SARA-U280 modules Device can work simultaneously in Packet Switch and Circuit Switch mode: voice calls are possible while the data connectio n is active without any interruption in service. Device can be attached to both GPRS and GSM services (i.e. Packet Switch and Circuit Switch mo de) using one service at a time. If for example during data transmission an incoming call occurs, the data conn ection is suspended to allow the voice communication. Once the voice call has terminated, the data service is resumed. SARA-U260 and SARA -U270 modules do not support 8 -PSK modulation in uplink; the EDGE Power Class corresponds to the GSM/GPRS Power Class GPRS / EDGE multi-slot class determines the number of timeslots available for upload and download and thus the speed at which data can be transmitted and received, with higher classes typically allowing faster data transfer rates. GPRS multi-slot class 12 implies a maximum of 4 slots in DL (reception) and 4 slots in UL (transmission) with 5 slots in total. EDGE multi-slot class 12 implies a maximum of 4 slots in DL (reception) and 4 slots in UL (transmission) with 5 slots in total. SARA-U260 and SARA-U270 modules support EDGE multi-slot class 12, MCS1-MCS9 up to 236.8 kb/s DL, MCS1-MCS4 up to 70.4 kb/s UL

SARA-U2 series - Data Sheet UBX-13005287 - R17 Functional description Page 8 of 57 Operation modes I to III are supported on GSM/GPRS networks, with user -defined preferred service selectable from GSM to GPRS. Paging messages for GSM calls can be optionally monitored during GPRS data transfer in not-coordinating NOM II-III. Direct Link mode is supported for TCP and UDP sockets. Basic features Supplementary services Short Message Service (SMS) Display of Called Number Call Hold/Resume (HOLD) Text and PDU mode supported Indication of Call Progress Signals Call Waiting (CW) Mobile-Originating SMS (MO SMS) Country/PLMN Indication Multi-Party (MTPY) Mobile-Terminating SMS (MT SMS) Country/PLMN Selection Call Forwarding (CFU, CFB, CFNRy, CFNRc) SMS indication and acknowledgement International Access Function Call Deflection (CD) SMS Cell Broadcast (CBS) Service Indicator Explicit Call Transfer (ECT) SMS during circuit-switched calls Emergency Calls Capabilities Call Barring (BAOC, BOIC, BOIC-exHC, BAIC, BIC_Roam) SMS over CSD Dual Tone Multi Frequency (DTMF) Advice of Charge Charging (AoCC, AoCI) SMS over PSD Subscription Identity Management Calling Line Identification Presentation (CLIP) SMS storage on SIM Service Provider Indication Calling Line Identification Restriction (CLIR) SMS storage on module memory Abbreviated Dialing Connected Line Identification Presentation (CoLP) Concatenated SMS Fixed Number Dialing Connected Line Identification Restriction (CoLR) Barring of Dialed Numbers Unstructured Supplementary Services Data (USSD) ME-SIM lock Calling Name Presentation (CNAP) SIM Access Profile Table 3: SARA-U2 series mobile stations: basic features, supplementary services and SMS service summary

1.5 AT command support

SARA-U2 series modules support AT commands according to the 3GPP Technical Specifications 27.007 [1], 27.005 [2], 27.010 [3], and the u-blox AT command extension. For the complete list of supported AT commands and their syntax see u-blox AT Commands Manual [4]. RIL (Radio Interface Layer ) software for Android and Embedded Windows is available for SARA -U2 series modules free of charge; see the Android RIL Production delivery [5] application note for more information.

1.6 Supported features

Table 4 lists the main features supported by SARA-U2 modules. For more details see the SARA-G3 and SARA-U2 series System Integration Manual [6] and u-blox AT commands manual [4]. Feature Description Network indication GPIO configured to indicate the network status: registered home network, registered roaming, voice or data call enabled, no service. The feature can be enabled through the +UGPIOC AT command. Antenna detection The ANT_DET pin provides antenna presence detection capability, evaluating the resistance from the ANT pin to GND by means of an external antenna detection circuit implemented on the application board. The antenna detection feature can be enabled through the +UANTR AT command. All these functionalities are supported via AT commands (for more details see u-blox AT Commands Manual [4]).

SARA-U2 series - Data Sheet UBX-13005287 - R17 Functional description Page 9 of 57 Feature Description Jamming detection Detects some “artificial” interference that obscures the operator’s carriers entitled to give access to the GSM/UMTS service and reports the start and stop of such conditions to the application processor (AP). The AP can react appropriately by e.g. switching off the radio transceiver to reduce power consumption and monitoring the environment at constant periods. The feature can be enabled and configured through the +UCD AT command. Embedded TCP and UDP stack Embedded TCP/IP and UDP/IP stack including direct link mode for TCP and UDP sockets. Sockets can be set in Direct Link mode to establish a transparent end to end communication with an already connected TCP or UDP socket via serial interface. FTP, FTPS File Transfer Protocol as well as Secure File Transfer Protocol (SSL encryption of FTP control channel) functionalities are supported via AT commands. HTTP, HTTPS Hyper-Text Transfer Protocol as well as Secure Hyper-Text Transfer Protocol (SSL encryption) functionalities is supported via AT commands. HEAD, GET, POST, DELETE and PUT operations are available. Up to four client contexts can be simultaneously used. Embedded TLS 1.2 With the support of X.509 certificates, Embedded TLS 1.2 provides server and client authentication, data encryption, data signature and enables TCP/IP applications like HTTPS and FTPS to communicate over a secured and trusted connection. The feature can be configured and enabled by +USECMNG and +USECPRF AT commands. IPv4/IPv6 dual-stack Capability to move between IPv4 and dual stack network infrastructures using external context. IPv4 and IPv6 addresses can be used. GNSS via modem Full access to u-blox positioning chips and modules is available through a dedicated DDC (I C) interface. This means that from any host processor a single serial port can control the cellular module and the positioning chip or module. For more details see the GNSS Implementation Application Note [7]. Embedded AssistNow Software Embedded AssistNow Online and AssistNow Offline clients to provide better GNSS performance and faster Time-to-First-Fix. An AT command can enable / disable the clients. CellLocate Enables the estimation of device position based on the parameters of the mobile network cells visible to the specific device based on the CellLocate database:  Normal scan: only the parameters of the visible home network cells are sent  Deep scan: the parameters of all surrounding cells of all mobile operators are sent CellLocate is implemented using a set of AT commands that allow configuration and position request. Hybrid Positioning The module current position is provided using a u-blox positioning chip or module or the estimated position from CellLocate depending by which positioning method provides the best and fastest solution according to the user configuration. Hybrid positioning is implemented through a set of AT commands that allow configuration and position request. Control Plan Aiding / LCS Assisted GPS Location Services feature, which is based on the Radio Resources Location Protocol (RRLP), according to 3GPP TS 44.031 [9], and Radio Resource Control (RRC), according to 3GPP TS 25.331 [17]. With the Assisted GPS feature, a location server provides the module with the GPS system information that otherwise must be downloaded from satellites. The feature allows faster position fixes, increases sensitivity and reduces module power consumption. The feature is invoked by the module through LCS Supplementary Services or by the Network during emergency calls. Firmware update Over AT commands (FOAT) Firmware module upgrade over UART and USB interface using AT command. The firmware upgrade can be executed through the +UFWUPD AT command. Smart Temperature Supervisor Constant monitoring of the module board temperature:  Warning notification when the temperature approaches an upper or lower predefined threshold  Shutdown notified and forced when the temperature value is outside the specified range (shutdown suspended in case of an emergency call in progress) The feature can be enabled or disabled through the +USTS AT command. The sensor measures board temperature, which can differ from ambient temperature. SIM Access Profile (SAP) Allows access and use of a remote (U)SIM card instead of the local SIM card directly connected to the module (U)SIM interface. The module acts as an SAP Client establishing a connection and performing data exchange to a SAP Server directly connected to the remote SIM. The modules provide a dedicated USB SAP channel and a dedicated multiplexer SAP channel over UART for communication with the remote (U)SIM card. The feature can be configured and enabled by +USAPMODE and + USAPIND AT commands. BIP Bearer Independent Protocol for Over-the-Air SIM provisioning. The data transfer to/from the SIM uses either an already active PDP context or a new PDP context established with the APN provided by the SIM card.

SARA-U2 series - Data Sheet UBX-13005287 - R17 Functional description Page 10 of 57 Feature Description In-Band Modem In-Band modem solution for eCall and ERA-GLONASS emergency call applications over cellular networks implemented according to the 3GPP TS 26.267 specification [8]. When activated, the in-vehicle eCall / ERA-GLONASS system (IVS) creates an emergency call carrying both voice and data (including vehicle position data) directly to the nearest Public Safety Answering Point (PSAP) to determine whether rescue services should be dispatched to the known position. DTMF decoder During a voice call, the Dual-Tone Multi-Frequency detector analyses the RX speech (coming from the remote party). The detected DTMF symbols can be output via the related URC. For more details, see the +UDTMFD AT command. Power saving The power saving configuration is by default disabled, but it can be configured using an AT command. When power saving is enabled, the module automatically enters the low power idle-mode whenever possible, reducing current consumption. During idle-mode, the module processor core runs with the RTC 32 kHz reference clock. The feature can be enabled through the +UPSV AT command. Automatic selection of authentication type Automatic selection of authentication type during PDP context activation. The module will sequentially try different authentication protocols (none/CHAP/PAP) until the authentication succeeds. The feature can be enabled through the +UPSD and +UAUTHREQ AT commands. Signal quality report for Packet Switched calls The quality of the GPRS UL and/or DL connection is returned by the AT+CSQ command. eMLPP Multi-Level Precedence and Pre-emption Service (eMLPP) permits to handle the call priority. The maximum priority associated to a user is set in the SIM: within this threshold, the user can assign different priorities to the calls. This results in a differentiated treatment of the calls by the network in case of abnormal events such as handovers to congested cells. The feature can be enabled through the +CAEMLPP, +CPPS, +CAAP AT commands. Network Friendly Mode When the Network Friendly Mode is enabled, the module reacts to service request denials by using time-spaced, randomized or delayed retry schemes according to GSMA IoT Device Connection Efficiency Guidelines [18]. The feature can be enabled through the +UNFM, +UNFMCONF and +URPM AT commands. Ethernet (CDC-ECM) over USB interface Ethernet (CDC-ECM) interface allowing networking from a HOST by means of the IP address received from the cellular network (bridge mode). The HOST configuration is performed via the DHCP protocol (a DHCP server is implemented). It operates as a not exclusive alternative to PPP dial-up. The feature can be configured by +UUSBCONF and enabled by +UCEDATA AT commands. ODIS OMA-DM IMEI Sync (ODIS) is an AT&T functionality required at the cellular module level and used to identify the end device operating inside the network. Last gasp In case of power supply outage (i.e. main supply interruption, battery removal, battery voltage below a certain threshold) the cellular module can be configured to send an alarm notification to a remote entity. The feature can be enabled and configured through the +ULGASP AT command. Firmware update Over The Air (FOTA) Embedded FOTA client to enable the Firmware module update over the cellular air interface. The feature can be enabled and configured through the +UFWINSTALL AT command. Smart radio Coverage Manager (SCM) Smart radio coverage manager is a feature that aims to reduce the power consumption in those cellular scenarios where the radio coverage or the network conditions would cause an inefficient usage of power supply. Table 4: Main supported features of the SARA-U2 series u-blox is extremely mindful of user privacy. When a position i s sent to the CellLocate server, u-blox is unable to track the SIM or the specific device that sent the position. Not supported by SARA-U260 and SARA-U280 modules Not supported by “00” product version Not supported on SARA-U260, SARA-U270 and SARA-U280 modules Not supported by "00","03","53","63","73" product versions

SARA-U2 series - Data Sheet UBX-13005287 - R17 Interfaces Page 11 of 57

2 Interfaces

2.1 Power management

2.1.1 Module supply (VCC)

SARA-U2 modules must be supplied through the VCC pins by a DC power supply. Voltages must be stable: during operation, the current drawn from VCC can vary by some order of magnitude, especially due to the surging consumption profile of the GSM system (described in SARA-G3 and SARA-U2 series System Integration Manual [6]). It is important that the system power supply circuit is able to support peak power.

2.1.2 RTC supply (V_BCKP)

V_BCKP is the Real Time Clock (RTC) supply of SARA -U2 modules. When VCC voltage is within the valid operating range, the internal Power Management Unit (PMU) supplies the RTC and the same supply voltage is available on V_BCKP pin. If the VCC voltage is under the minimum operating limit (e.g. during not powered mode), the V_BCKP pin can externally supply the RTC.

2.1.3 Generic digital interfaces supply (V_INT)

SARA-U2 modules provide a 1.8 V supply rail output on the V_INT pin, which is internally generated when the module is switched on. The same voltage domain is used internally to supply the generi c digital interfaces of the modules. The V_INT supply output can be used in place of an external discrete regulator optimizing the bill of material for various applications, e.g. with u-blox GNSS receivers operating at 1.8 V.

2.2 Antenna

2.2.1 Antenna RF interface (ANT)

The ANT pin has an impedance of 50  and provides the RF antenna interface of SARA-U2 modules.

2.2.2 Antenna detection (ANT_DET)

The ANT_DET pin is an Analog to Digital Converter (ADC) input to sense the antenna presence (as optional feature), evaluating the resistance from the ANT pin to GND by means of an external antenna detection circuit implemented on the application board (for more details see the SARA-G3 and SARA-U2 series System Integration Manual [6] and the u-blox AT Commands Manual [4], +UANTR).

2.3 System functions

2.3.1 Module power-on

SARA-U2 modules can be switched on in one of the following ways:  Rising edge on VCC pins to a valid voltage for module supply, i.e. applying module supply  Low pulse on PWR_ON pin, i.e. forcing the pin (normally high with external pull-up) to a low level for a valid time period (see section 4.2.6): PWR_ON pin requires an external pull -up resistor to set its value to logic high and may not be left floating  Rising edge on RESET_N pin, i.e. releasing the pin from the low level, normally high with internal pull-up  RTC alarm, i.e. pre-programmed scheduled time by AT+CALA command

SARA-U2 series - Data Sheet UBX-13005287 - R17 Interfaces Page 12 of 57

2.3.2 Module power-off

SARA-U2 modules can be properly switched off, with storage of current parameter settings and network detach, in one of these ways:  AT+CPWROFF command  Low pulse on the PWR_ON pin for at least 1 s An abrupt under -voltage shutdown occ urs on SARA -U2 modules when the VCC supply drops below the extended operating range minimum limit, but in this case it is not possible to perform the storing of the current parameter settings in the module’s non-volatile memory as well as the proper network detach. An over-temperature or an under -temperature shutdown occurs on SARA-U2 modules when the temperature measured within the cellular module reaches the dangerous area, if the optional Smart Temperature Supervisor feature is enabled and configured by the dedicated AT command. For more details see the SARA-G3 and SARA-U2 series System Integration Manual [6] and u-blox AT commands manual [4], +USTS AT command.

2.3.3 Module reset

SARA-U2 modules can be properly reset (rebooted), with storage of current parameter settings and network detach, in this way:  By the AT+CFUN command (see the u-blox AT Commands Manual [4]). This causes an “internal” or “software” reset of the baseband processor, excluding the integrated power management unit and the RTC internal block: the V_INT generic digital interfaces supply is enabled and each digital pin is set to its inte rnal reset state (reported in Table 6), the V_BCKP supply and the RTC block are enabled. An abrupt “external” or “hardware” reset occurs when a low level is applied to the RESET_N pin, which is normally set high by an internal pull -up, for a valid time period (see section 4.2.7). This causes a reset of the entire module, including the integrated power management unit, except for the RTC internal block: the V_INT generic digital interfaces supply is switched off and all the digital pins are tri -stated, but the V_BCKP supply and the RTC block are enabled. The current parameter settings are not saved in the module’s non -volatile memory and a proper network detach is not performed.

2.4 SIM

2.4.1 (U)SIM interface SARA-U2 modules provide a (U)SIM interface on the VSIM, SIM_IO, SIM_CLK, SIM_RST pins: the high -speed SIM/ME interface is implemented as well as automatic detection of the required SIM supporting voltage. Both 1.8 V and 3 V SIM card/chip types are supported (1.8 V and 3 V ME). Activation and deactivation with automatic voltage switch from 1.8 V to 3 V is implemented, according to ISO -IEC 7816-3 specifications. The SIM driver supports the PPS (Protocol and Parameter Selection) pr ocedure for baud -rate selection, according to the values proposed by the SIM card/chip.

2.4.2 SIM card detection (SIM_DET)

The SIM_DET pin of SARA -U2 modules is a 1.8 V digital input which is by default configured as an external interrupt to detect the SIM card presence (as a feature which can be optionally used) when it is properly connected to the mechanical switch of the SIM card holder (for more details see SARA-G3 and SARA-U2 series System Integration Manual [6]). The SIM_DET pin of SARA -U2 modules can additionally be configured via AT command to provide the “SIM card hot insertion/removal” function (for more details see u-blox AT Commands Manual [4], +UDCONF=50). The SIM_DET pin of SARA -U2 modules can additionally be configured via AT command as GPIO (for more details see section 2.7 and the u-blox AT Commands Manual [4], +UGPIOC, +UGPIOR, +UGPIOW).

SARA-U2 series - Data Sheet UBX-13005287 - R17 Interfaces Page 13 of 57

2.5 Serial interfaces

SARA-U2 modules provide the following serial communication interfaces:  UART interface: 9-wire unbalanced 1.8 V asynchronous serial interface supporting (see 2.5.1) o AT command mode o Data mode and Online command mode o MUX functionality, including dedicated GNSS tunneling and SIM Access Profile virtual channels o FW upgrades by means of the FOAT feature o FW upgrades by means of the u-blox EasyFlash tool o Trace log capture (diagnostic purpose)  Auxiliary UART interface : 3 -wire unbalanced 1.8 V asynchronous serial interface, available as alternative function, in mutually exclusive way, over the DDC (I C) interface’ pins, supporting (see 2.5.2) o AT command mode o Trace log capture (diagnostic purpose)  USB interface: High-Speed USB 2.0 compliant interface supporting (see 2.5.3) o AT command mode o Data mode and Online command mode o GNSS tunneling and SIM Access Profile virtual channels o Ethernet-over-USB virtual channel o FW upgrades by means of the FOAT feature o FW upgrades by means of the u-blox EasyFlash tool o Trace log capture (diagnostic purpose)  DDC interface: I C-bus compatible 1.8 V interface supporting (see 2.5.4) o Communication with u-blox GNSS positioning chips / modules o Communication with other external I C devices as an audio codec

2.5.1 Asynchronous serial interface (UART)

The UART interface is a 9 -wire 1.8 V unbalanced asynchronous serial interface supporting AT command mode, Data mode and Online command mode, MUX functionality, including dedicated GNSS tunneling and SIM Access Profile virtual channels, FW upgrades by means of the FOAT feature, FW upgr ades by means of the u -blox EasyFlash tool, and Trace log capture (diagnostic purpose). The UART features are:  Complete serial port with RS -232 functionality conforming to the ITU-T V.24 Recommendation [10], with CMOS compatible signal levels (0 V for low data bit or ON state and 1.8 V for high data bit or OFF state)  Data lines (RXD as output, TXD as input), hardware flow control lines (CTS as output, RTS as input), modem status and control lines (DTR as input, DSR as output, DCD as output, RI as output) are provided  Hardware flow control (default value), software flow control, or none flow control are supported  Power saving indication available on the hardware flow control output (CTS line): the line is driven t o the OFF state when the module is not prepared to accept data by the UART interface See the u-blox AT Commands Manual [4] for the definition of the command mode, data mode, and online command mode. SARA-U2 modules product versions "00", "03", "53", "63", "73" do not provide Auxiliary UART interface. SARA-U2 modules product versions "00" do not support Ethernet-over-USB. If enabled

SARA-U2 series - Data Sheet UBX-13005287 - R17 Interfaces Page 14 of 57  1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800 and 921600 b/s baud rates are supported for the AT interface  Autobauding is by default enabled  Frame format can be: o 8N2 (8 data bits, no parity, 2 stop bits) o 8N1 (8 data bits, no parity, 1 stop bit) o 8E1 (8 data bits, even parity, 1 stop bit) o 8O1 (8 data bits, odd parity, 1 stop bit) o 7E1 (7 data bits, even parity, 1 stop bit) o 7O1 (7 data bits, odd parity, 1 stop bit)  Default frame configuration is 8N1 The UART serial interface can be conveniently configured through AT commands. For more details see the u-blox AT Commands Manual [4] (+IPR, +ICF, + IFC, &K, \\Q, +UPSV AT command) and SARA-G3 and SARA-U2 series System Integration Manual [6].

2.5.1.1 Autobauding feature

Only one shot autobauding is supported: the baud rate detection is performed only once, at module start up. After detection the module works at the fixed baud rate (the detected one) and the baud rate can only be changed via the appropriate AT command (+IPR, for more details see the u-blox AT Commands Manual [4]).  The module detects the followings baud rates (b/s): 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400  The only detectable frame configurations are: 7E1, 7O1, 8N1, 8E1, 8O1

2.5.1.2 Multiplexer protocol

SARA-U2 module has a software layer with MUX function ality, 3GPP TS 27.010 Multiplexer Protocol [3], available on the UART interface. The multiplexer protocol is supported over the UART physical interface only. This is a data link protocol (layer 2 of OSI model) which uses HDLC -like framing and operates between the cellular module (Data Circuit-terminating Equipment) and the application processor (Data Terminal Equipment) allowing simultaneous sessions over the UART physical link: the user can concurrently use AT command interface on one MUX channel and Data communication on another MUX channel. Each session consists of a stream of bytes transferring various kinds of data such as SMS, CBS, PSD, GNSS, AT commands in general. SARA-U2 modules provide the following virtual channels:  Channel 0: control channel  Channel 1 – 5: AT commands / data connection  Channel 6: GNSS tunneling  Channel 7: SAP (SIM Access Profile) For more details see the Mux Implementation Application Note [11].

SARA-U2 series - Data Sheet UBX-13005287 - R17 Interfaces Page 15 of 57

2.5.2 Auxiliary asynchronous serial interface (AUX UART)

Not supported by "00", "03", "53", "63", "73" product versions. The auxiliary UART interface is a 3-wire 1.8 V unbalanced asynchronous serial interface supporting AT command mode and Trace log capture (diagnostic purpose). The auxiliary UART interface is by default disabled, and it can be enabled by means of the +USIO AT command (for more details see the u-blox AT Commands Manual [4]), as alternative function of the DDC (I C) interface’ pins, in mutually exclusive way with the DDC (I C) interface. The auxiliary UART features are:  Only the RXD_AUX data output and the TXD_AUX data input are provided, with CMOS compatible signal levels (0 V for low data bit or ON state and 1.8 V for high data bit or OFF state)  Data lines (SCL pin configured as RXD_AUX output, SDA pin configured as TXD_AUX input)  Software flow control, or none flow control (default value) are supported  1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800 and 9 21600 b/s baud rates are supported for the AT interface  Autobauding is by default enabled  Frame format can be: o 8N2 (8 data bits, no parity, 2 stop bits) o 8N1 (8 data bits, no parity, 1 stop bit) o 8E1 (8 data bits, even parity, 1 stop bit) o 8O1 (8 data bits, odd parity, 1 stop bit) o 7E1 (7 data bits, even parity, 1 stop bit) o 7O1 (7 data bits, odd parity, 1 stop bit)  Default frame configuration is 8N1 The auxiliary UART serial interface can be conveniently configured through AT commands. For more details see the u-blox AT Commands Manual [4] (+IPR, +ICF, +IFC, &K, \\Q, +UPSV AT command) and the SARA-G3 and SARA-U2 series System Integration Manual [6].

2.5.2.1 Autobauding feature

Only one shot autobauding is supported: the baud rate detection is performed only once, at module start up. After detection the module works at the fixed baud rate (the detected one) and the baud rate can only be changed via the appropriate AT command (+IPR, for more details see the u-blox AT Commands Manual [4]).  The module detects the followings baud rates (b/s): 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400  The only detectable frame configurations are: 7E1, 7O1, 8N1, 8E1, 8O1

SARA-U2 series - Data Sheet UBX-13005287 - R17 Interfaces Page 16 of 57

2.5.3 Universal Serial Bus (USB)

SARA-U2 series modules include a high -speed USB 2.0 compliant interface with maximum 480 Mb/s data rate. The module itself acts as a USB device and can be connected to any USB host. The USB is the suitable interface for transferring high speed data between SARA-U2 series and a host processor, available for AT commands, data communication, FW upgrade by means of the FOAT feature, FW upgrade by means of the u-blox EasyFlash tool and for diagnostic purpose. The USB_D+ / USB_D- lines carry the USB serial data and signaling. The USB interface is automatically enabled by an external valid USB VBUS supply voltage (5.0 V typical) applied on the VUSB_DET pin. SARA-U2 series modules can provide the following functions over the USB interface:  CDC-ACM for AT commands and data communication  CDC-ACM for GNSS tunneling  CDC-ACM for diagnostic  CDC-ACM for SAP (SIM Access Profile)  CDC-ECM for Ethernet-over-USB CDC-ECM for Ethernet-over-USB function is not supported by the “00” product version. The default configuration of the USB interface provides 7 USB CDC-ACM modem COM ports:  USB1: AT and data  USB2: AT and data  USB3: AT and data  USB4: GNSS tunneling  USB5: Primary Log (diagnostic purpose)  USB6: Secondary Log (diagnostic purpose)  USB7: SAP (SIM Access Profile) The user can concurrently use the AT command interface on one CDC, and Packet -Switched / Circuit-Switched Data communication on another CDC. The USB interface can be configured by the AT+UUSBCONF command to provide a different set of functions, including 1 CDC-ECM for Ethernet-over-USB and 4 CDC-ACM modem COM ports enumerated as follows:  USB1: AT and data  USB2: GNSS tunneling  USB3: Primary Log (diagnostic purpose)  USB4: SAP (SIM Access Profile) The default profile of the USB interface cannot be changed on the “00” product version. For more details regarding the USB configurations and capabilities, see the SARA-G3 and SARA-U2 series System Integration Manual [6] and the u-blox AT Commands Manual [4] (+UUSBCONF AT command).

SARA-U2 series - Data Sheet UBX-13005287 - R17 Interfaces Page 17 of 57 USB drivers are available for the following operating system platforms:  Windows XP  Windows Vista  Windows 7  Windows 8  Windows 8.1  Windows 10  Windows CE 5.0  Windows Embedded CE 6.0  Windows Embedded Compact 7  Windows Embedded Automotive 7  Windows Mobile 5  Windows Mobile 6  Windows Mobile 6.1  Windows Mobile 6.5 SARA-U2 modules are compatible with standard Linux/Android USB kernel drivers.

2.5.4 DDC (I

C) bus interface SARA-U2 modules include an I C compatible DDC interface ( SDA, SCL) available to communicate with a u -blox GNSS receiver and with external I C devices as an audio codec: SARA-U2 module acts as an I C master which can communicate with I C slaves in accordance to the I C bus specifications [12].

2.6 Audio

SARA-U2 modules have one 4 -wire I S digital audio interface ( I2S_CLK, I2S_RXD, I2S_TXD and I2S_WA) that can be configured by AT commands in PCM or in normal I S mode. (For more details see the u-blox AT Commands Manual [4] and the SARA-G3 and SARA-U2 series System Integration Manual [6].) SARA-U2 modules provide a digital clock output (CODEC_CLK) for an external audio codec.

SARA-U2 series - Data Sheet UBX-13005287 - R17 Interfaces Page 18 of 57

2.7 GPIO

SARA-U2 modules provide nine pins ( GPIO1, GPIO2, GPIO3, GPIO4, I2S_RXD, I2S_TXD, I2S_CLK, I2S_WA, SIM_DET) which can be configured as general purpose input/output, or to provide the custom functions listed in Table 5 via u-blox AT commands. For further details see the SARA-G3 and SARA-U2 series System Integration Manual [6] and the u-blox AT Commands Manual [4], +UGPIOC, +UGPIOR, +UGPIOW, +UGPS, +UGPRF, +USPM, +UDCONF=50, +ULGASP AT commands. Function Description Module Default GPIO Configurable GPIOs GSM Tx-burst indication GSM transmit slot indication SARA-U201, SARA-U260, SARA-U270 -- GPIO1 GNSS supply enable Enable/disable the supply of the u-blox GNSS receiver connected to the cellular module All GPIO2 GPIO1, GPIO2, GPIO3, GPIO4, SIM_DET GNSS data ready Input to sense when the u-blox GNSS receiver connected to the cellular module is ready for sending data over the DDC (I C) interface All GPIO3 GPIO3 GNSS RTC sharing RTC synchronization signal to the u-blox GNSS receiver connected to the cellular module All GPIO4 GPIO4 SIM card detection SIM card physical presence detection All SIM_DET SIM_DET SIM card hot insertion Enable/disable SIM interface upon detection of external SIM card physical insertion/removal All -- SIM_DET Last gasp Input to trigger the delivery of a last alarm notification to a remote entity SARA-U201 -- GPIO3 Network status indication Network status: registered 2G / 3G home network, registered 2G / 3G roaming, 2G / 3G data transmission, no service All -- GPIO1, GPIO2, GPIO3, GPIO4, SIM_DET Module status indication Module status: power off mode, i.e. module switched off, versus idle, active or connected mode, i.e. module switched on All -- GPIO1 Module operating mode indication Module operating mode: idle mode versus active or connected mode All -- SIM_DET I S digital audio interface I S digital audio interface (I2S_RXD, I2S_TXD, I2S_CLK, I2S_WA respectively) All I2S_RXD, I2S_TXD, I2S_CLK, I2S_WA I2S_RXD, I2S_TXD, I2S_CLK, I2S_WA General purpose input Input to sense high or low digital level All -- All General purpose output Output to set the high or the low digital level All -- All Pin disabled Tri-state with an internal active pull-down enabled All GPIO1 All Table 5: GPIO custom functions configuration Not supported by "03", "63" product versions

SARA-U2 series - Data Sheet UBX-13005287 - R17 Pin definition Page 19 of 57

3 Pin definition

3.1 Pin assignment

V_INT V_BCKP GND CODEC_CLK RESET_N GPIO1 PWR_ON RXD TXD 24 27 30 5962 56 GND GND DSR DTR GND VUSB_DET GND GND USB_D- USB_D+ RSVD GND GPIO2 GPIO3 SDA SCL GPIO4 GND GND GND RSVD RSVD RSVD RSVD GND VCC VCC RSVD I2S_TXD I2S_CLK SIM_CLK SIM_IO VSIM SIM_DET VCC RSVD RSVD SIM_RST I2S_RXD I2S_WA GND GND GND GND GND GND GND GND GND ANT_DET ANT SARA-U2 Top View Pin 65-96: GND Figure 4: SARA-U2 series pin assignment No Name Power domain I/O Description Remarks

1 GND - N/A Ground All the GND pins must be connected to ground

2 V_BCKP - I/O Real Time Clock supply

V_BCKP = 1.8 V (typical) generated by the module to supply the Real Time Clock when VCC supply voltage is within valid operating range. See section 4.2.2 for detailed electrical specs.

3 GND - N/A Ground All the GND pins must be connected to ground

4 V_INT - O Generic Digital Interfaces

V_INT = 1.8 V (typical) generated by the module when it is switched-on and the RESET_N (external reset input pin) is not forced to the low level. See section 4.2.2 for detailed electrical specs.

5 GND - N/A Ground All the GND pins must be connected to ground

SARA-U2 series - Data Sheet UBX-13005287 - R17 Pin definition Page 20 of 57 No Name Power domain I/O Description Remarks 6 DSR GDI O UART data set ready Circuit 107 (DSR) in ITU-T V.24. Output driver class D. PU/PD class a. Value at internal reset: T/PU. See section 4.2.9 for detailed electrical specs. 7 RI GDI O UART ring indicator Circuit 125 (RI) in ITU-T V.24. Output driver class C_0. PU/PD class c. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs. 8 DCD GDI O UART data carrier detect Circuit 109 (DCD) in ITU-T V.24. Output driver class C_0. PU/PD class c. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs.

9 DTR GDI I UART data terminal

Circuit 108/2 (DTR) in ITU-T V. 24. Internal active pull-up to V_INT enabled. PU/PD class c. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs. 10 RTS GDI I UART ready to send Circuit 105 (RTS) in ITU-T V.24. Internal active pull-up to V_INT enabled. PU/PD class a. Value at internal reset: T/PU. See section 4.2.9 for detailed electrical specs. 11 CTS GDI O UART clear to send Circuit 106 (CTS) in ITU-T V.24. Output driver class A. PU/PD class a. Value at internal reset: T/PU. See section 4.2.9 for detailed electrical specs. 12 TXD GDI I UART data input Circuit 103 (TxD) in ITU-T V.24. Internal active pull-up to V_INT enabled. PU/PD class a. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs. 13 RXD GDI O UART data output Circuit 104 (RxD) in ITU-T V.24. Output driver class A. PU/PD class a. Value at internal reset: T/PU. See section 4.2.9 for detailed electrical specs.

14 GND - N/A Ground All the GND pins must be connected to ground

15 PWR_ON POS I Power-on input The PWR_ON pin has high input impedance:

don’t leave it floating in noisy environment (an external pull-up resistor is required) See section 4.2.6 for detailed electrical specs. 16 GPIO1 GDI I/O GPIO GPIO configurable as described in Table 5. Output driver class A. PU/PD class a. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs. 17 VUSB_DET USB I USB detect input Input for VBUS (5 V typical) USB supply sense. See section 4.2.10 for detailed electrical specs. 18 RESET_N ERS I External reset input Internal 10 k pull-up resistor to V_BCKP. See section 4.2.7 for detailed electrical specs. 19 CODEC_CLK GDI O Clock output Output driver class B. PU/PD class b. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs.

20 GND - N/A Ground All the GND pins must be connected to ground

21 GND - N/A Ground All the GND pins must be connected to ground

22 GND - N/A Ground All the GND pins must be connected to ground

23 GPIO2 GDI I/O GPIO GPIO configurable as described in Table 5. Output driver class A. PU/PD class a. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs.

SARA-U2 series - Data Sheet UBX-13005287 - R17 Pin definition Page 21 of 57 No Name Power domain I/O Description Remarks 24 GPIO3 GDI I/O GPIO GPIO configurable as described in Table 5. Output driver class A. PU/PD class a. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs. 25 GPIO4 GDI I/O GPIO GPIO configurable as described in Table 5. Output driver class A. PU/PD class a. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs.

26 SDA DDC I/O I

C bus data line Fixed open drain. No internal pull-up. Value at internal reset: T. See section 4.2.11 for detailed electrical specs. GDI I AUX UART data input Not supported by "00","03","53","63","73" product versions Circuit 103 (TxD) in ITU-T V.24. Internal active pull-up to V_INT enabled. PU/PD class a. Value at internal reset: T. See section 4.2.9 for detailed electrical specs.

27 SCL DDC O I

C bus clock line Fixed open drain. No internal pull-up. Value at internal reset: T. See section 4.2.11 for detailed electrical specs. GDI O AUX UART data output Not supported by "00","03","53","63","73" product versions Circuit 104 (RxD) in ITU-T V.24. Output driver class E. PU/PD class a. Value at internal reset: T. See section 4.2.9 for detailed electrical specs. 28 USB_D- USB I/O USB Data Line D- 90  nominal differential impedance. Pull-up, pull-down and series resistors as required by USB 2.0 specifications [15] are part of the USB pin driver and need not be provided externally. Value at internal reset: T. See section 4.2.10 for detailed electrical specs. 29 USB_D+ USB I/O USB Data Line D+ 90  nominal differential impedance. Pull-up, pull-down and series resistors as required by USB 2.0 specifications [15] are part of the USB pin driver and need not be provided externally. Value at internal reset: T. See section 4.2.10 for detailed electrical specs.

30 GND - N/A Ground All the GND pins must be connected to ground

31 RSVD - N/A RESERVED pin Leave unconnected.

32 GND - N/A Ground All the GND pins must be connected to ground

33 RSVD - N/A RESERVED pin This pin must be connected to GND.

34 I2S_WA GDI I/O /

I S word alignment / GPIO Configurable as I S word alignment (Input with internal active pull-down enabled in slave mode, Output in master mode), or as GPIO (see Table 5). Output driver class C. PU/PD class a. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs.

35 I2S_TXD GDI O /

I S transmit data / GPIO Configurable as I S transmit data out, or as GPIO (see Table 5) Output driver class C. PU/PD class a. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs.

36 I2S_CLK GDI I/O /

I S clock / GPIO Configurable as I S clock (Input with internal active pull-down in slave mode, Output in master mode), or as GPIO (see Table 5). Output driver class C. PU/PD class a. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs.

SARA-U2 series - Data Sheet UBX-13005287 - R17 Pin definition Page 22 of 57 No Name Power domain I/O Description Remarks

37 I2S_RXD GDI I /

I S receive data / GPIO Configurable as I S receive data input (with internal active pull- down enabled), or as GPIO (see Table 5). Output driver class C. PU/PD class a. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs. 38 SIM_CLK SIM O SIM clock Value at internal reset: L. See section 4.2.8 for detailed electrical specs. 39 SIM_IO SIM I/O SIM data Internal 4.7 k pull-up resistor to VSIM. Value at internal reset: L/PD. See section 4.2.8 for detailed electrical specs. 40 SIM_RST SIM O SIM reset Value at internal reset: L. See section 4.2.8 for detailed electrical specs. 41 VSIM - O SIM supply output VSIM = 1.80 V typical or 2.90 V typical generated by the module according to the SIM card type. See section 4.2.2 for detailed electrical specs.

42 SIM_DET GDI I SIM detection Configurable for the SIM card presence detection function, or

as GPIO (see Table 5). PU/PD class a. Value at internal reset: T/PD. See section 4.2.9 for detailed electrical specs.

43 GND - N/A Ground All the GND pins must be connected to ground

44 RSVD - N/A RESERVED pin Leave unconnected. 45 RSVD - N/A RESERVED pin Leave unconnected. 46 RSVD - N/A RESERVED pin Leave unconnected. 47 RSVD - N/A RESERVED pin Leave unconnected. 48 RSVD - N/A RESERVED pin Leave unconnected. 49 RSVD - N/A RESERVED pin Leave unconnected.

50 GND - N/A Ground All the GND pins must be connected to ground

51 VCC - I Module supply input All VCC pins must be connected to external supply. 52 VCC - I Module supply input All VCC pins must be connected to external supply. 53 VCC - I Module supply input All VCC pins must be connected to external supply.

54 GND - N/A Ground All the GND pins must be connected to ground

55 GND - N/A Ground All the GND pins must be connected to ground

56 ANT - I/O RF input/output 50  nominal impedance

See section 4.2.4 for detailed electrical specs.

57 GND - N/A Ground All the GND pins must be connected to ground

58 GND - N/A Ground All the GND pins must be connected to ground

59 GND - N/A Ground All the GND pins must be connected to ground

60 GND - N/A Ground All the GND pins must be connected to ground

61 GND - N/A Ground All the GND pins must be connected to ground

62 ANT_DET ADC I Antenna detection Antenna presence detection function. See section 4.2.5 for detailed electrical specs.

63 GND - N/A Ground All the GND pins must be connected to ground

64 GND - N/A Ground All the GND pins must be connected to ground

65-96 GND - N/A Ground All the GND pins must be connected to ground Table 6: SARA-U2 series module pin-out For more information about pin-out see the SARA-G3 and SARA-U2 series System Integration Manual [6]. For an explanation of abbreviations and terms used, see Appendix A.

SARA-U2 series - Data Sheet Page 23 of 57

4 Electrical specifications

Stressing the device above one or mor e of the ratings listed in the Absolute Maximum Rating section may cause permanent damage. These are stress ratings only. Operating the module at these or at any conditions other than those specified in the Operating Conditions sections (section 4.2) of the specification should be avoided. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. Operating conditions ranges define those limits within which the functionality of the device is guaranteed. Where application information is given, it is advisory only and does not form part of the specification.

4.1 Absolute maximum rating

Limiting values given below are in accordance with the Absolute Maximum Rating System (IEC 134). Symbol Description Condition Min. Max. Unit VCC Module supply voltage Input DC voltage at VCC pins -0.30 5.50 V VUSB_DET USB detection pin Input DC voltage at VUSB_DET pin -0.30 5.35 V USB USB D+/D- pins Input DC voltage at USB_D+ and USB_D- pins -1.00 5.35 V V_BCKP RTC supply voltage Input DC voltage at V_BCKP pin -0.15 2.00 V GDI Generic digital interfaces Input DC voltage at Generic digital interfaces pins -0.30 3.60 V DDC DDC interface Input DC voltage at DDC interface pins -0.30 3.60 V SIM SIM interface Input DC voltage at SIM interface pin -0.30 3.60 V ERS External reset signal Input DC voltage at RESET_N external reset pin -0.15 2.10 V POS Power-on signal Input DC voltage at PWR_ON power-on pin -0.30 5.50 V ADC Antenna detection pin Input DC voltage at ANT_DET pin -0.15 3.00 V P_ANT Antenna power Input RF power at ANT pin -10 dBm Rho_ANT Antenna ruggedness Output RF load mismatch ruggedness at ANT pin 15:1 VSWR Tstg Storage temperature -40 90 °C Table 7: Absolute maximum ratings The product is not protected against overvoltage or reversed voltages. If necessary, voltage spikes exceeding the power supply voltage specification, given in table above, must be limited to values within the specified boundaries by using appropriate protection devices.

4.1.1 Maximum ESD

Parameter Module Min. Typ. Max. Unit Remarks ESD sensitivity for all pins except ANT pin All 1000 V Human Body Model according to JESD22-A114F ESD sensitivity for ANT pin All 1000 V Human Body Model according to JESD22-A114F ESD immunity for ANT pin SARA-U201 4000 V Contact Discharge according to IEC 61000-4-2

8000 V Air Discharge according to IEC 61000-4-2

SARA-U260, SARA-U270, SARA-U280

2000 V Contact Discharge according to IEC 61000-4-2

4000 V Air Discharge according to IEC 61000-4-2

Table 8: Maximum ESD ratings SARA-U2 modules are Electrostatic Sensitive Devices (ESD) and require special precautions when handling. See section 7.4 for ESD handling instructions.

SARA-U2 series - Data Sheet Page 24 of 57

4.2 Operating conditions

Unless otherwise indicated, all operating condition specifications are at an ambient temperature of 25°C. Operation beyond the operating conditions is not recommended and extended exposure beyond them may affect device reliability.

4.2.1 Operating temperature range

Symbol Parameter Module Min. Typ. Max. Units Remarks Topr Operating temperature range All -40 +85 °C Normal operating temperature range SARA-U201 -20 +65 °C See section 4.2.1.1 SARA-U260, SARA-U270, SARA-U280 -20 +55 °C See section 4.2.1.1 Extended operating temperature range All -40 -20 °C Extended operating temperature range 1 See section 4.2.1.2 SARA-U201 +65 +85 °C Extended operating temperature range 2 See section 4.2.1.3 SARA-U260, SARA-U270, SARA-U280 +55 +85 °C Extended operating temperature range 2 See section 4.2.1.3 Table 9: Environmental conditions

4.2.1.1 Normal operating temperature range

The cellular module is fully functional and meets the 3GPP specification across the specified temperature range.

4.2.1.2 Extended operating temperature range 1

The cellular module is fully functional across the specified temperature range. Occasional deviations from the 3GPP specification may occur.

4.2.1.3 Extended operating temperature range 2

The cellular module is functiona l across the specified temperature range. Occasional deviations from the 3GPP specification may occur. Thermal protection including automatic shutdown is implemented for protection against overheating. Thermal protection is disabled for emergency calls. Fo r more details, see the u-blox AT Commands Manual [4], +USTS AT command).

SARA-U2 series - Data Sheet Page 25 of 57

4.2.2 Supply/Power pins

Symbol Parameter Min. Typ. Max. Unit VCC Module supply normal operating input voltage 3.30 3.80 4.40 V Module supply extended operating input voltage 3.10 4.50 V V_BCKP RTC supply input voltage 1.00 1.80 1.90 V I_BCKP RTC supply average current consumption, at V_BCKP = 1.8 V 2.00 µA Table 10: Input characteristics of Supply/Power pins Symbol Parameter Min. Typ. Max. Unit VSIM SIM supply output voltage 1.76 1.80 1.83 V 2.84 2.90 2.94 V V_BCKP RTC supply output voltage 1.71 1.80 1.89 V I_BCKP RTC supply output current capability 3 mA V_INT Digital I/O Interfaces supply output voltage 1.73 1.80 1.87 V V_INT_RIPPLE Digital I/O Interfaces supply output peak-to-peak voltage ripple during active or connected mode 15 mV Digital I/O Interfaces supply output peak-to-peak voltage ripple during low power idle mode with power saving enabled by AT+UPSV command 70 mV I_INT Digital I/O Interfaces supply output current capability 70 mA Table 11: Output characteristics of Supply/Power pins Input voltage at VCC must be above the normal operating range minimum limit to switch-on the module. Occasional deviations from the 3GPP specifications may occur. Ensure that input voltage at VCC never drops below the extended operating range minimum limit during module operation: the module may switch-off when the VCC voltage value drops below the extended operating range minimum limit.

SARA-U2 series - Data Sheet Page 26 of 57

4.2.3 Current consumption

Mode Condition Band Module Min Typ Max Unit Power Off Mode Averaged current, module switched off SARA-U201 55 µA SARA-U260, SARA-U270, SARA-U280 65 µA Idle-Mode (Power Saving enabled by AT+UPSV, module in low power idle-mode, equivalent to +CFUN=0) Averaged current over a 100-ms period, USB interface disconnected All 0.5 mA Averaged current over a 100-ms period, USB interface connected and suspended All 0.9 mA 2G Cyclic Idle/Active-Mode (Power Saving enabled by AT+UPSV, Module registered with network) Averaged current over a 10-minute period, DRX = 9 , +UPSV=2 or 3, USB disconnected All All 0.9 mA Averaged current over a 10-minute period, DRX = 5 , +UPSV=1, USB disconnected All All 1.2 mA Averaged current over a 10-minute period, DRX = 5 , +UPSV=1, USB suspended All All 1.6 mA 2G Active-Mode (Power Saving disabled by AT+UPSV=0, Module registered with network) Averaged current over a 10-minute period, DRX = 5 , USB disconnected All All 14.7 mA Averaged current over a 10-minute period, DRX = 5 , USB connected and not suspended All All 34.3 mA GSM Connected Mode (Tx / Rx call enabled) Peak current during a 1-slot Tx burst Maximum Tx power 850, 900 All 1.55 1.90 A Averaged current over a 10-second period,

1 Tx + 1 Rx slot, Minimum Tx power

All SARA-U201, SARA-U260, SARA-U270 45 mA Averaged current over a 10-second period,

1 Tx + 1 Rx slot, Maximum Tx power

850, 900 SARA-U201 240 mA SARA-U260, SARA-U270 210 mA 1800, 1900 SARA-U201 160 mA SARA-U260, SARA-U270 135 mA GPRS Connected Mode (Tx / Rx call enabled) Averaged current over a 10-second period,

4 Tx + 1 Rx slots, Maximum Tx power

850, 900 SARA-U201 600 mA SARA-U260, SARA-U270 560 mA 1800, 1900 SARA-U201 400 mA SARA-U260, SARA-U270 350 mA EDGE Connected Mode (Tx / Rx call enabled) Averaged current over a 10-second period, 850, 900 SARA-U201 470 mA 1800, 1900 SARA-U201 490 mA Typical values with a matched antenna Maximum values with a mismatched antenna Module is registered with the network, with a paging period of 2.12 s (2G network DRX setting = 9), with none neighbour cell. Module is registered with the network, with a paging period of 1.18 s (2G network DRX setting = 5), with 16 neighbour cells. It is recommended to use this figure to dimension maximum current capability of power supply. Condition for GPRS and EDGE multi-slot output power: Multi-Slot Power Reduction profile 2 (+UDCONF=40 AT command default value).

SARA-U2 series - Data Sheet Page 27 of 57 Mode Condition Band Module Min Typ Max Unit 3G Cyclic Idle/Active-Mode (Power Saving enabled by AT+UPSV, Module registered with network) Averaged current over a 10-minute period, DRX = 9 , +UPSV=2 or 3, USB disconnected All All 0.9 mA Averaged current over a 10-minute period, DRX = 7 , +UPSV=1, USB disconnected All All 1.3 mA Averaged current over a 10-minute period, DRX = 7 , +UPSV=1, USB suspended All All 1.7 mA 3G Active-Mode (Power Saving disabled by AT+UPSV=0, Module registered with network) Averaged current over a 10-minute period, DRX = 7 , USB disconnected All All 14.1 mA Averaged current over a 10-minute period, DRX = 7 , USB connected and not suspended All All 33.7 mA UMTS Connected Mode (Tx / Rx call enabled) Averaged current over a 10-second period, 12.2 kb/s UL, 12.2 kb/s DL Minimum Tx power 1, 2 All 120 mA 5, 8, 19 All 115 mA Averaged current over a 10-second period, 12.2 kb/s UL, 12.2 kb/s DL Tx power = 0 dBm 1, 2 All 140 mA 5, 8, 19 All 135 mA Averaged current over a 10-second period, 12.2 kb/s UL, 12.2 kb/s DL Tx power = 12 dBm 1, 2 All 200 mA 5, 8, 19 All 190 mA Averaged current over a 10-second period, 12.2 kb/s UL, 12.2 kb/s DL Tx power = 18 dBm 1, 2 All 350 mA 5, 8, 19 All 325 mA Averaged current over a 10-second period, 12.2 kb/s UL, 12.2 kb/s DL Maximum Tx power 1, 2 SARA-U201 510 mA SARA-U260, SARA-U270, SARA-U280 625 mA 5, 8, 19 SARA-U201 430 mA SARA-U260, SARA-U270, SARA-U280 565 mA HSDPA Connected Mode (Tx / Rx call enabled) Averaged current over a 10-second period, Maximum DL data rate (HSDPA) Maximum Tx power 1, 2 SARA-U201 550 mA SARA-U260, SARA-U270, SARA-U280 680 mA 5, 8, 19 SARA-U201 500 mA SARA-U260, SARA-U270, SARA-U280 595 mA HSUPA or HSPA Connected Mode (Tx / Rx call enabled) Averaged current over a 10-second period, Maximum UL data rate (HSUPA) or Maximum both UL/DL data rate (HSPA) Maximum Tx power 1, 2 SARA-U201 425 mA SARA-U260, SARA-U270, SARA-U280 580 mA 5, 8, 19 SARA-U201 390 mA SARA-U260, SARA-U270, SARA-U280 510 mA Table 12: VCC current consumption Module is registered with the network, with a paging period of 5.12 s (3G network DRX setting = 9). Module is registered with the network, with a paging period of 1.28 s (3G network DRX setting = 7).

SARA-U2 series - Data Sheet Page 28 of 57

4.2.4 RF characteristics

The 3G and 2G bands supported by each SARA -U2 series module are defined in Table 2, while the following Table 13 lists the Transmitting and Receiving frequencies for each 3G and 2G band, according to 3GPP TS 34.121-1 [13] and 3GPP TS 51.010-1 [14]. Parameter Min. Max. Unit Remarks Frequency range GSM 850 Uplink 824 849 MHz Module transmit Downlink 869 894 MHz Module receive Frequency range E-GSM 900 Uplink 880 915 MHz Module transmit Downlink 925 960 MHz Module receive Frequency range DCS 1800 Uplink 1710 1785 MHz Module transmit Downlink 1805 1880 MHz Module receive Frequency range PCS 1900 Uplink 1850 1910 MHz Module transmit Downlink 1930 1990 MHz Module receive Frequency range UMTS Band 19 (800 MHz) Uplink 830 845 MHz Module transmit Downlink 875 890 MHz Module receive Frequency range UMTS Band 5 (850 MHz) Uplink 824 849 MHz Module transmit Downlink 869 894 MHz Module receive Frequency range UMTS Band 8 (900 MHz) Uplink 880 915 MHz Module transmit Downlink 925 960 MHz Module receive Frequency range UMTS Band 2 (1900 MHz) Uplink 1850 1910 MHz Module transmit Downlink 1930 1990 MHz Module receive Frequency range UMTS Band 1 (2100 MHz) Uplink 1920 1980 MHz Module transmit Downlink 2110 2170 MHz Module receive Table 13: Operating RF frequency bands SARA-U2 series modules include a UE Power Class 3 3G transmitter, a GMSK Power Cla ss 4 transmitter for GSM/E-GSM bands, and a GMSK Power Class 1 transmitter for DCS/PCS bands (see Table 2). SARA-U201 modules also include an 8-PSK Power Class E2 transmitter for all 2G bands (see Table 2). Output power and characteristics are compliant with 3GPP TS 34.121-1 [13] and 3GPP TS 51.010-1 [14]. SARA-U2 series modules 3G and 2G receiver characteristics are compliant to 3GPP TS 34.121 -1 [13] and 3GPP TS 51.010-1 [14], with conducted receiver sensitivity performance specified in Table 14. Parameter Min. Typ. Max. Unit Remarks Receiver input sensitivity GSM 850 / E-GSM 900 -109.0 dBm Downlink RF level @ BER Class II < 2.4 % Receiver input sensitivity DCS 1800 / PCS 1900 -109.0 dBm Downlink RF level @ BER Class II < 2.4 % Receiver input sensitivity UMTS Band 19 (850 MHz) -111.0 dBm Downlink RF level for RMC @ BER < 0.1 % Receiver input sensitivity UMTS Band 5 (850 MHz) -111.0 dBm Downlink RF level for RMC @ BER < 0.1 % Receiver input sensitivity UMTS Band 8 (900 MHz) -110.0 dBm Downlink RF level for RMC @ BER < 0.1 % Receiver input sensitivity UMTS Band 2 (1900 MHz) -110.0 dBm Downlink RF level for RMC @ BER < 0.1 % Receiver input sensitivity UMTS Band 1 (2100 MHz) -110.0 dBm Downlink RF level for RMC @ BER < 0.1 % Condition: 50  source Table 14: Receiver sensitivity performance

SARA-U2 series - Data Sheet Page 29 of 57

4.2.5 ANT_DET pin

Pin Name Parameter Min. Typ. Max. Unit Remarks ANT_DET Output DC current pulse value 10 µA Output DC current pulse time length 128 µs Table 15: ANT_DET pin characteristics

4.2.6 PWR_ON pin

Pin Name Parameter Min. Typ. Max. Unit Remarks PWR_ON Internal supply for Power-On Input Signal 1.71 1.80 1.89 V RTC supply (V_BCKP) L-level input -0.30 0.65 V High input impedance (no internal pull-up) H-level input 1.50 4.40 V High input impedance (no internal pull-up) L-level input current -6 µA PWR_ON low time to switch-on the module 50 80 µs PWR_ON low time to switch-off the module 1000 ms Table 16: PWR_ON pin characteristics (POS domain)

4.2.7 RESET_N pin

Pin Name Parameter Min. Typ. Max. Unit Remarks RESET_N Internal supply for External Reset Input Signal 1.71 1.80 1.89 V RTC supply (V_BCKP) L-level input -0.30 0.51 V H-level input 1.32 2.01 V L-level input current -180 µA Pull-up resistance 10 k Internal pull-up to RTC supply (V_BCKP) RESET_N low time to perform a proper reset 50 ms Table 17: RESET_N pin characteristics (ERS domain)

SARA-U2 series - Data Sheet Page 30 of 57 4.2.8 (U)SIM pins The SIM pins are a dedicated interface to the external SIM card/chip. The electrical characteristics fulfill regulatory specification requirements. The values in Table 18 are for information only. Parameter Min. Typ. Max. Unit Remarks Low-level input 0.00 0.35 V VSIM = 1.80 V 0.00 0.57 V VSIM = 2.90 V High-level input 1.29 3.30 V VSIM = 1.80 V 2.07 3.30 V VSIM = 2.90 V Low-level output 0.00 0.35 V VSIM = 1.80 V, Max value at IOL = +1.0 mA 0.00 0.35 V VSIM = 2.90 V, Max value at IOL = +1.0 mA High-level output 1.26 1.80 V VSIM = 1.80 V, Min value at IOH = -1.0 mA 2.03 2.90 V VSIM = 2.90 V, Min value at IOH = -1.0 mA Input/Output leakage current 0.7 µA 0.2V < VIN < 3.3V Internal pull-up resistor on SIM_IO to VSIM 4.7 k Clock frequency on SIM_CLK 3.25 MHz Table 18: (U)SIM pins characteristics (SIM domain)

SARA-U2 series - Data Sheet Page 31 of 57

4.2.9 Generic Digital Interfaces pins

Parameter Min. Typ. Max. Unit Remarks Internal supply for GDI domain 1.73 1.80 1.87 V Generic Digital Interfaces supply (V_INT) Input characteristic: L-level input -0.20 0.35 V Input characteristic: H-level input 1.31 1.93 V Output characteristics: L-level output 0.00 0.20 V Max value at IOL = +0.1 mA for driver class A 0.00 0.35 V Max value at IOL = +6.0 mA for driver class A 0.00 0.20 V Max value at IOL = +0.1 mA for driver class B 0.00 0.35 V Max value at IOL = +4.0 mA for driver class B 0.00 0.20 V Max value at IOL = +0.1 mA for driver class C 0.00 0.35 V Max value at IOL = +2.0 mA for driver class C 0.00 0.45 V Max value at IOL = +2.0 mA for driver class C_0 0.00 0.20 V Max value at IOL = +0.1mA for driver class D 0.00 0.35 V Max value at IOL = +1.0 mA for driver class D 0.00 0.20 V Max value at IOL = +0.1 mA for driver class E Output characteristics: H-level output 1.45 1.80 V Min value at IOH = -6.0 mA for driver class A 1.60 1.80 V Min value at IOH = -0.1 mA for driver class A 1.45 1.80 V Min value at IOH = -4.0 mA for driver class B 1.60 1.80 V Min value at IOH = -0.1 mA for driver class B 1.45 1.80 V Min value at IOH = -2.0 mA for driver class C 1.60 1.80 V Min value at IOH = -0.1 mA for driver class C 1.35 1.80 V Min value at IOH = -2.0 mA for driver class C_0 1.45 1.80 V Min value at IOH = -1.0 mA for driver class D 1.60 1.80 V Min value at IOH = -0.1 mA for driver class D 1.60 1.80 V Min value at IOH = -0.1 mA for driver class E Input/Output leakage current 0.7 µA 0.2 V < VIN < 1.93 V Pull-up input current -240 µA PU Class a -150 µA PU Class b -125 µA PU Class c Pull-down input current +200 µA PD Class a +150 µA PD Class b +45 µA PD Class c Table 19: Generic Digital Interfaces pins characteristics (GDI domain)

4.2.9.1 AC characteristics of digital audio interfaces pins

S digital audio interface can be configured in 4 different modes:  Normal I S mode – Master mode  Normal I S mode – Slave mode  PCM mode – Master mode  PCM mode – Slave mode AC characteristics of the 4 different modes of the I S digital audio interface are reported as follows.

SARA-U2 series - Data Sheet Page 33 of 57 Parameter Description Min. Typ. Max. Unit Remarks T2 I S clock high time 1.933 1.953 µs <I2S_sample_rate>=0 1.397 1.417 µs <I2S_sample_rate>=1 1.282 1.302 µs <I2S_sample_rate>=2 0.957 0.977 µs <I2S_sample_rate>=3 0.689 0.709 µs <I2S_sample_rate>=4 0.631 0.651 µs <I2S_sample_rate>=5 0.468 0.488 µs <I2S_sample_rate>=6 0.334 0.354 µs <I2S_sample_rate>=7 0.306 0.326 µs <I2S_sample_rate>=8 T3 I S clock low time 1.933 1.953 µs <I2S_sample_rate>=0 1.397 1.417 µs <I2S_sample_rate>=1 1.282 1.302 µs <I2S_sample_rate>=2 0.957 0.977 µs <I2S_sample_rate>=3 0.689 0.709 µs <I2S_sample_rate>=4 0.631 0.651 µs <I2S_sample_rate>=5 0.468 0.488 µs <I2S_sample_rate>=6 0.334 0.354 µs <I2S_sample_rate>=7 0.306 0.326 µs <I2S_sample_rate>=8 I S word alignment period 125.0 µs <I2S_sample_rate>=0 90.70 µs <I2S_sample_rate>=1 83.33 µs <I2S_sample_rate>=2 62.50 µs <I2S_sample_rate>=3 45.35 µs <I2S_sample_rate>=4 41.67 µs <I2S_sample_rate>=5 31.25 µs <I2S_sample_rate>=6 22.68 µs <I2S_sample_rate>=7 20.83 µs <I2S_sample_rate>=8 I S word alignment frequency 8.000 kHz <I2S_sample_rate>=0 11.03 kHz <I2S_sample_rate>=1 12.00 kHz <I2S_sample_rate>=2 16.00 kHz <I2S_sample_rate>=3 22.05 kHz <I2S_sample_rate>=4 24.00 kHz <I2S_sample_rate>=5 32.00 kHz <I2S_sample_rate>=6 44.10 kHz <I2S_sample_rate>=7 48.00 kHz <I2S_sample_rate>=8 T4 I S TXD invalid before I S CLK high end (before shifting edge of I S CLK) 24 ns <I2S_mode> = 2,4,6,8,10,12 I S TXD invalid before I S CLK low end (before shifting edge of I S CLK) 24 ns <I2S_mode> = 3,5,7,9,11,13 T5 I S TXD valid after I S CLK low begin (after shifting edge of I S CLK) 32 ns <I2S_mode> = 2,4,6,8,10,12 I S TXD valid after I S CLK high begin (after shifting edge of I S CLK) 32 ns <I2S_mode> = 3,5,7,9,11,13 T6 I S RXD setup time before I S CLK low end (before latching edge of I S CLK) 60 ns <I2S_mode> = 2,4,6,8,10,12 I S RXD setup time before I S CLK high end (before latching edge of I S CLK) 60 ns <I2S_mode> = 3,5,7,9,11,13 T7 I S RXD hold time after I S CLK high begin (after latching edge of I S CLK) 10 ns <I2S_mode> = 2,4,6,8,10,12 I S RXD hold time after I S CLK low begin (after latching edge of I S CLK) 10 ns <I2S_mode> = 3,5,7,9,11,13 Table 20: AC characteristics of digital audio interface in Normal I S mode and Master mode enabled

SARA-U2 series - Data Sheet Page 35 of 57 Parameter Description Min. Typ. Max. Unit Remarks I S word alignment period 125.0 µs <I2S_sample_rate>=0 90.70 µs <I2S_sample_rate>=1 83.33 µs <I2S_sample_rate>=2 62.50 µs <I2S_sample_rate>=3 45.35 µs <I2S_sample_rate>=4 41.67 µs <I2S_sample_rate>=5 31.25 µs <I2S_sample_rate>=6 22.68 µs <I2S_sample_rate>=7 20.83 µs <I2S_sample_rate>=8 I S word alignment frequency 8.000 kHz <I2S_sample_rate>=0 11.03 kHz <I2S_sample_rate>=1 12.00 kHz <I2S_sample_rate>=2 16.00 kHz <I2S_sample_rate>=3 22.05 kHz <I2S_sample_rate>=4 24.00 kHz <I2S_sample_rate>=5 32.00 kHz <I2S_sample_rate>=6 44.10 kHz <I2S_sample_rate>=7 48.00 kHz <I2S_sample_rate>=8 T4 I S TXD invalid before I S CLK falling edge (before shifting edge of I S CLK) 24 ns <I2S_mode> = 2,4,6,8,10,12 I S TXD invalid before I S CLK rising edge (before shifting edge of I S CLK) 24 ns <I2S_mode> = 3,5,7,9,11,13 T5 I S TXD valid after I S CLK falling edge (after shifting edge of I S CLK) 32 ns <I2S_mode> = 2,4,6,8,10,12 I S TXD valid after I S CLK rising edge (after shifting edge of I S CLK) 32 ns <I2S_mode> = 3,5,7,9,11,13 T6 I S RXD setup time before I S CLK rising edge (before latching edge of I S CLK) 60 ns <I2S_mode> = 2,4,6,8,10,12 I S RXD setup time before I S CLK falling edge (before latching edge of I S CLK) 60 ns <I2S_mode> = 3,5,7,9,11,13 T7 I S RXD hold time after I S CLK rising edge (after latching edge of I S CLK) 10 ns <I2S_mode> = 2,4,6,8,10,12 I S RXD hold time after I S CLK falling edge (after latching edge of I S CLK) 10 ns <I2S_mode> = 3,5,7,9,11,13 Table 21: AC characteristics of digital audio interface in Normal I S mode and Slave mode enabled

SARA-U2 series - Data Sheet Page 37 of 57 Parameter Description Min. Typ. Max. Unit Remarks 1/T1 I S clock frequency 144.0 144.1 kHz <I2S_mode>=0, <I2S_sample_rate>=0 136.0 136.1 kHz <I2S_mode>=1, <I2S_sample_rate>=0 198.5 198.6 kHz <I2S_mode>=0, <I2S_sample_rate>=1 187.4 187.6 kHz <I2S_mode>=1, <I2S_sample_rate>=1 216.0 216.2 kHz <I2S_mode>=0, <I2S_sample_rate>=2 204.0 204.2 kHz <I2S_mode>=1, <I2S_sample_rate>=2 288.0 288.3 kHz <I2S_mode>=0, <I2S_sample_rate>=3 272.0 272.3 kHz <I2S_mode>=1, <I2S_sample_rate>=3 396.9 397.5 kHz <I2S_mode>=0, <I2S_sample_rate>=4 374.9 375.4 kHz <I2S_mode>=1, <I2S_sample_rate>=4 432.0 432.7 kHz <I2S_mode>=0, <I2S_sample_rate>=5 408.0 408.7 kHz <I2S_mode>=1, <I2S_sample_rate>=5 576.0 577.3 kHz <I2S_mode>=0, <I2S_sample_rate>=6 544.0 545.2 kHz <I2S_mode>=1, <I2S_sample_rate>=6 793.8 796.3 kHz <I2S_mode>=0, <I2S_sample_rate>=7 749.7 752.0 kHz <I2S_mode>=1, <I2S_sample_rate>=7 864.0 867.0 kHz <I2S_mode>=0, <I2S_sample_rate>=8 816.0 818.7 kHz <I2S_mode>=1, <I2S_sample_rate>=8 T2 I S clock low time 3.452 3.472 µs <I2S_mode>=0, <I2S_sample_rate>=0 3.656 3.676 µs <I2S_mode>=1, <I2S_sample_rate>=0 2.500 2.520 µs <I2S_mode>=0, <I2S_sample_rate>=1 2.648 2.668 µs <I2S_mode>=1, <I2S_sample_rate>=1 2.295 2.315 µs <I2S_mode>=0, <I2S_sample_rate>=2 2.431 2.451 µs <I2S_mode>=1, <I2S_sample_rate>=2 1.716 1.736 µs <I2S_mode>=0, <I2S_sample_rate>=3 1.818 1.838 µs <I2S_mode>=1, <I2S_sample_rate>=3 1.240 1.260 µs <I2S_mode>=0, <I2S_sample_rate>=4 1.314 1.334 µs <I2S_mode>=1, <I2S_sample_rate>=4 1.137 1.157 µs <I2S_mode>=0, <I2S_sample_rate>=5 1.205 1.225 µs <I2S_mode>=1, <I2S_sample_rate>=5 0.848 0.868 µs <I2S_mode>=0, <I2S_sample_rate>=6 0.899 0.919 µs <I2S_mode>=1, <I2S_sample_rate>=6 0.610 0.630 µs <I2S_mode>=0, <I2S_sample_rate>=7 0.647 0.667 µs <I2S_mode>=1, <I2S_sample_rate>=7 0.559 0.579 µs <I2S_mode>=0, <I2S_sample_rate>=8 0.593 0.613 µs <I2S_mode>=1, <I2S_sample_rate>=8 T3 I S clock high time 3.452 3.472 µs <I2S_mode>=0, <I2S_sample_rate>=0 3.656 3.676 µs <I2S_mode>=1, <I2S_sample_rate>=0 2.500 2.520 µs <I2S_mode>=0, <I2S_sample_rate>=1 2.648 2.668 µs <I2S_mode>=1, <I2S_sample_rate>=1 2.295 2.315 µs <I2S_mode>=0, <I2S_sample_rate>=2 2.431 2.451 µs <I2S_mode>=1, <I2S_sample_rate>=2 1.716 1.736 µs <I2S_mode>=0, <I2S_sample_rate>=3 1.818 1.838 µs <I2S_mode>=1, <I2S_sample_rate>=3 1.240 1.260 µs <I2S_mode>=0, <I2S_sample_rate>=4 1.314 1.334 µs <I2S_mode>=1, <I2S_sample_rate>=4 1.137 1.157 µs <I2S_mode>=0, <I2S_sample_rate>=5 1.205 1.225 µs <I2S_mode>=1, <I2S_sample_rate>=5 0.848 0.868 µs <I2S_mode>=0, <I2S_sample_rate>=6 0.899 0.919 µs <I2S_mode>=1, <I2S_sample_rate>=6 0.610 0.630 µs <I2S_mode>=0, <I2S_sample_rate>=7 0.647 0.667 µs <I2S_mode>=1, <I2S_sample_rate>=7

SARA-U2 series - Data Sheet Page 38 of 57 Parameter Description Min. Typ. Max. Unit Remarks 0.559 0.579 µs <I2S_mode>=0, <I2S_sample_rate>=8 0.593 0.613 µs <I2S_mode>=1, <I2S_sample_rate>=8 I S word alignment period 125.0 µs <I2S_sample_rate>=0 90.70 µs <I2S_sample_rate>=1 83.33 µs <I2S_sample_rate>=2 62.50 µs <I2S_sample_rate>=3 45.35 µs <I2S_sample_rate>=4 41.67 µs <I2S_sample_rate>=5 31.25 µs <I2S_sample_rate>=6 22.68 µs <I2S_sample_rate>=7 20.83 µs <I2S_sample_rate>=8 I S word alignment frequency 8.000 kHz <I2S_sample_rate>=0 11.03 kHz <I2S_sample_rate>=1 12.00 kHz <I2S_sample_rate>=2 16.00 kHz <I2S_sample_rate>=3 22.05 kHz <I2S_sample_rate>=4 24.00 kHz <I2S_sample_rate>=5 32.00 kHz <I2S_sample_rate>=6 44.10 kHz <I2S_sample_rate>=7 48.00 kHz <I2S_sample_rate>=8 T4 I S CLK high begin to I S WA high begin -24 32 ns <I2S_mode> = 0 T5 I S CLK low end to I S WA high end -24 32 ns <I2S_mode> = 0 T6 I S TXD invalid before I S CLK low end 24 ns <I2S_mode> = 0 T7 I S TXD valid after I S CLK high begin 22 ns <I2S_mode> = 0 T8 I S RXD setup time before I S CLK high end 60 ns <I2S_mode> = 0 T9 I S RXD hold time after I S CLK low begin 12 ns <I2S_mode> = 0 Table 22: AC characteristics of digital audio interface in PCM mode (<I2S_mode> = 0,1) and Master mode enabled

SARA-U2 series - Data Sheet Page 40 of 57 Parameter Description Min. Typ. Max. Unit Remarks 1/T1 I S clock frequency 144.0 kHz <I2S_mode>=0, <I2S_sample_rate>=0 136.0 kHz <I2S_mode>=1, <I2S_sample_rate>=0 198.5 kHz <I2S_mode>=0, <I2S_sample_rate>=1 187.4 kHz <I2S_mode>=1, <I2S_sample_rate>=1 216.0 kHz <I2S_mode>=0, <I2S_sample_rate>=2 204.0 kHz <I2S_mode>=1, <I2S_sample_rate>=2 288.0 kHz <I2S_mode>=0, <I2S_sample_rate>=3 272.0 kHz <I2S_mode>=1, <I2S_sample_rate>=3 396.9 kHz <I2S_mode>=0, <I2S_sample_rate>=4 374.9 kHz <I2S_mode>=1, <I2S_sample_rate>=4 432.0 kHz <I2S_mode>=0, <I2S_sample_rate>=5 408.0 kHz <I2S_mode>=1, <I2S_sample_rate>=5 576.0 kHz <I2S_mode>=0, <I2S_sample_rate>=6 544.0 kHz <I2S_mode>=1, <I2S_sample_rate>=6 793.8 kHz <I2S_mode>=0, <I2S_sample_rate>=7 749.7 kHz <I2S_mode>=1, <I2S_sample_rate>=7 864.0 kHz <I2S_mode>=0, <I2S_sample_rate>=8 816.0 kHz <I2S_mode>=1, <I2S_sample_rate>=8 I S word alignment period 125.0 µs <I2S_sample_rate>=0 90.70 µs <I2S_sample_rate>=1 83.33 µs <I2S_sample_rate>=2 62.50 µs <I2S_sample_rate>=3 45.35 µs <I2S_sample_rate>=4 41.67 µs <I2S_sample_rate>=5 31.25 µs <I2S_sample_rate>=6 22.68 µs <I2S_sample_rate>=7 20.83 µs <I2S_sample_rate>=8 I S word alignment frequency 8.000 kHz <I2S_sample_rate>=0 11.03 kHz <I2S_sample_rate>=1 12.00 kHz <I2S_sample_rate>=2 16.00 kHz <I2S_sample_rate>=3 22.05 kHz <I2S_sample_rate>=4 24.00 kHz <I2S_sample_rate>=5 32.00 kHz <I2S_sample_rate>=6 44.10 kHz <I2S_sample_rate>=7 48.00 kHz <I2S_sample_rate>=8 T4 I S WA high begin before I S CLK low begin (latching edge of I S CLK) 36 ns <I2S_mode>= 0 T5 I S WA low begin before I S CLK low begin (latching edge of I S CLK) 36 ns <I2S_mode>= 0 T6 I S TXD invalid before I S CLK rising edge (shifting edge of I S CLK) 12 ns <I2S_mode>= 0 T7 I S TXD valid after I S CLK rising edge (shifting edge of I S CLK) 79 ns <I2S_mode>= 0 T8 I S RXD setup time before I S CLK falling edge (latching edge of I S CLK) 22 ns <I2S_mode>= 0 T9 I S RXD hold time after I S CLK falling edge (latching edge of I S CLK) 24 ns <I2S_mode>= 0 Table 23: AC characteristics of digital audio interface in PCM mode (<I2S_mode> = 0,1) and Slave mode enabled

SARA-U2 series - Data Sheet Page 41 of 57

4.2.9.2 AC characteristics of Digital Clock Output pin

CODEC_CLK (Output) Figure 13: AC characteristics of CODEC_CLK digital clock output Parameter Description Min. Typ. Max. Unit Remarks T1 CODEC_CLK clock period 38 ns CODEC_CLK output set to 26 MHz 77 ns CODEC_CLK output set to 13 MHz 1/T1 CODEC_CLK clock frequency 26 MHz CODEC_CLK output set to 26 MHz

13 MHz CODEC_CLK output set to 13 MHz

T2 CODEC_CLK clock low time 10 ns CODEC_CLK output set to 26 MHz 26 ns CODEC_CLK output set to 13 MHz T3 CODEC_CLK clock high time 10 ns CODEC_CLK output set to 26 MHz 26 ns CODEC_CLK output set to 13 MHz Table 24: AC characteristics of CODEC_CLK digital clock output

4.2.10 USB pins

USB data lines ( USB_D+ and USB_D-) are compliant to the USB 2.0 high -speed specification. See the Universal Serial Bus Revision 2.0 specification [15] for detailed electrical characteristics. The values in Table 25 related to USB 2.0 high-speed physical layer specifications are for information only. Parameter Min. Typ. Max. Unit Remarks USB detection voltage on pin VUSB_DET 4.40 5.00 5.25 V Current sink at VUSB_DET 30 µA High-speed squelch detection threshold (input differential signal amplitude) 100 150 mV High speed disconnect detection threshold (input differential signal amplitude) 525 625 mV High-speed data signaling input common mode voltage range -50 500 mV High-speed idle output level -10 10 mV High-speed data signaling output high level 360 440 mV High-speed data signaling output low level -10 10 mV Chirp J level (output differential voltage) 700 1100 mV Chirp K level (output differential voltage) -900 -500 mV Table 25: USB pins characteristics

SARA-U2 series - Data Sheet Page 42 of 57 C) pins DDC (I C) lines ( SCL and SDA) are compliant to the I C-bus standard mode specification . See the I C-bus Specifications [12] for detailed electrical characteristics. The values in Table 26 related to I C-bus standard mode specifications are for information only. Parameter Min. Typ. Max. Unit Remarks Internal supply for DDC domain 1.73 1.80 1.87 V Generic Digital Interfaces supply (V_INT) L-level input -0.20 0.35 V H-level input 1.31 1.93 V L-level output 0.00 0.35 V Max value at IOL = +1.0 mA Input/Output leakage current 0.7 µA 0.2 V < VIN < 1.93 V Clock frequency on SCL 100 kHz Table 26: DDC (I C) pins characteristics (DDC domain)

SARA-U2 series - Data Sheet UBX-13005287 - R17 Mechanical specifications Page 43 of 57

5 Mechanical specifications

C R R P Q K M1 M1 M2 E G E ANT pin B Pin 1 Indicator K G H1 J1 A D D O O L N LI F F Figure 14: SARA-U2 series modules dimensions (bottom and sides views) Parameter Description Typical Tolerance Weight Module Weight [g] < 3 Table 27: SARA-U2 series modules dimensions Module height tolerance +/ –0.20 mm may be exceeded close to the corn ers of the PCB due to cutting process: in worst case the height could be +0.40 mm longer than the typical value. For information regarding Footprint and Paste Mask see the SARA-G3 and SARA-U2 series System Integration Manual [6].

SARA-U2 series - Data Sheet UBX-13005287 - R17 Reliability tests and approvals Page 44 of 57

6 Reliability tests and approvals

6.1 Reliability tests

Tests for product family qualifications are according to ISO 16750 “Road vehicles - Environmental conditions and testing for electrical and electronic equipment“, and appropriate standards.

6.2 Approvals

6.2.1 SARA-U2 series

Products marked with this lead -free symbol on the product label comply with the "Directive 2002/95/EC of the European Parliament and the Council on the Restriction of Use of certain Hazardous Substances in Electrical and Electronic Equipment" RoHS). SARA-U2 modules are RoHS compliant. No natural rubbers, hygroscopic materials, or materials containing asbestos are employed. Table 28 lists the SARA-U2 series main approvals. Certification Scheme SARA-U201 SARA-U201 ATEX SARA-U260 SARA-U270 SARA-U270 ATEX SARA-U280 GCF (Global Certification Forum) • • • • PTCRB (PCS Type Certification Review Board) • • • • CE (Conformité Européenne) • • • • FCC (United States Federal Communications Commission) FCC identification number XPY1CGM5NNN XPY1CGM5NNN XPYSARAU260 XPYSARAU280 ISED (Innovation, Science and Economic Development, formerly known as IC - Industry Canada) ISED certification number 8595A-1CGM5NNN 8595A-1CGM5NNN 8595A-SARAU260 8595A-SARAU280 Anatel (Brazilian Certification) • • RCM (Australia Regulatory Compliance Mark) • • • • Giteki (Japan approval mark) • • KCC (Korean KC mark) • • NCC (Taiwanese National Communications Commission) • • CCC (China Compulsory Certification) • • • • SRRC (State Radio Regulation of China) • • • • AT&T (US Network Operator) • • • • Rogers Canada (Canadian Network Operator) • • KT (Korean Network Operator) • SKT (Korean Network Operator) • NTT DoCoMo (Japanese Network Operator) • ATEX (ATmospheric EXplosives) • • Table 28: SARA-U2 series main certification approvals For all the certificates of compliancy and for the complete list of approvals (including countries’ and network operators’ approvals) of SARA-U2 series modules, see our website (http://www.u-blox.com/) or please contact the u-blox office or sales representative nearest you.

SARA-U2 series - Data Sheet UBX-13005287 - R17 Reliability tests and approvals Page 45 of 57

6.2.2 SARA-U201 ATEX and SARA-U270 ATEX

SARA-U201 ATEX and SARA-U270 ATEX modules are cer tified as components intended for use in potentially explosive atmospheres compliant to the following standards:  IEC 60079-0: 2011  IEC 60079-11: 2011  IEC 60079-26: 2006 The certification numbers of the modules according to the ATEX directive 2014/34/EU are:  SARA-U201 ATEX: SIQ 16 ATEX 298 U  SARA-U270 ATEX: SIQ 15 ATEX 017 U The certification numbers of the modules according to the IECEx conformity assessment system are:  SARA-U201 ATEX: IECEx SIQ 16.0006U  SARA-U270 ATEX: IECEx SIQ 15.0001U According to the standards listed above, the modules are certified with the following marking:  SARA-U201 ATEX: Ex II 1G, Ex ia IIB  SARA-U270 ATEX: Ex II 1G, Ex ia IIC/IIB According to the marking stated above, the modules are certified as electrical equipment of:  group ‘II’: intended for use in areas with explosive gas atmosphere other than mines susceptible to firedamp  category ‘1G’: intended for use in zone 0 hazardous areas, in which explosive atmospheres caused by mixtures of air and gases, vapors or mists are present continuously, for long periods or frequently  level of protection ‘ia’: intrinsically safe apparatus with very high level of protection, not capable of causing ignition in normal operation and with the application of one countable fault or a combination of an y two countable fault plus those non-countable faults which give the most onerous condition  subdivision ‘IIB’: intended for use in areas where the nature of the explosive gas atmosphere is considered dangerous based on the Maximum Experimental Safe Gap or the Minimum Ignition Current ratio of the explosive gas atmosphere in which the equipment may be installed (a typical gas is ethylene), so that the modules are also suitable for applications intended for use in subdivision IIA (a typical gas is propane)  subdivision ‘IIC/IIB’: intended for use in areas where the nature of the explosive gas atmosphere is considered very dangerous based on the Maximum Experimental Safe Gap or the Minimum Ignition Current ratio of the explosive gas atmosphere in which the equipment may be installed (a typical gas is hydrogen), so that the modules are also suitable for applications intended for use in subdivision IIB (typical gas is ethylene) and subdivision IIA (a typical gas is propane) Section 4.2.1 defines the temperature range of use for SARA-U201 ATEX and SARA-U270 ATEX modules. The RF radiating profile of the modules is compliant to all the applicable 3GPP / ETSI standards, with a maximum of 2 W RF pulse power (corresponding to 1 .15 mJ RF pulse energy) and with a maximum average power of 250 mW according to the GSM/GPRS and WCDMA power class stated in Table 2. Section 9.1 describes the nameplate of SARA-U201 ATEX and SARA-U270 ATEX modules (see the Figure 19 and Figure 20). The following maximum input and equivalent parameters must be considered in sub-division IIC: SARA-U270 ATEX Ui 3.8 V Ii 1.6 A (burst) Ci 132 µF Li 9.8 µH

SARA-U2 series - Data Sheet UBX-13005287 - R17 Reliability tests and approvals Page 46 of 57 The following maximum input and equivalent parameters must be considered in sub -divisions IIB, IIA (two different configurations are allowed for SARA-U201 ATEX): SARA-U201 ATEX SARA-U270 ATEX Ui 3.8 4.2 4.2 Ii 2.5 A (burst) 1.6 A (burst) 2.5 A (burst) Ci 169 µF 169 µF 132 µF Li 9.4 µH 9.4 µH 9.8 µH For more information about the integration of these modules in applications intended for use in potentially explosive atmospheres, see the SARA-G3 / SARA-U2 Series System Integration Manual [6].

SARA-U2 series - Data Sheet UBX-13005287 - R17 Product handling & soldering Page 47 of 57

7 Product handling & soldering

7.1 Packaging

SARA-U2 modules are delivered as hermetically sealed, reeled tapes to enable efficient production, pro duction lot set-up and tear-down. For more information about packaging, see u-blox Package Information Guide [16]. Figure 15: Reeled SARA-U2 modules

7.1.1 Reels

SARA-U2 modules are delivera ble in quantities of 250 pieces on a reel. SARA -U2 modules are delivered using reel Type B2 as described in the u-blox Package Information Guide [16]. Parameter Specification Reel type B2 Delivery quantity 250 Table 29: Reel information for SARA-U2 modules Quantities of less than 250 pieces are also available. Contact u-blox for more information.

SARA-U2 series - Data Sheet UBX-13005287 - R17 Product handling & soldering Page 48 of 57

7.1.2 Tapes

Figure 16 shows the position and the orientation of SARA-U2 series modules as they are delivered on the tape, while Figure 17 and Table 30 specify the tape dimensions. Pin 1Sprocket hole Feed direction Figure 16: Orientation for SARA-U2 series modules on tape Figure 17: SARA-U2 series tape dimensions (mm) Parameter Typical value Tolerance Unit A0 16.8 0.2 mm B0 26.8 0.2 mm K0 3.2 0.2 mm Table 30: SARA-U2 series tape dimensions (mm) Note 1: 10 sprocket hole pitch cumulative tolerance ± 0.2 mm. Note 2: pocket position relative to sprocket hole is measured as true position of pocket, not pocket hole. Note 3: A0 and B0 are calculated on a plane at a distance “R” above the bottom of the pocket.

SARA-U2 series - Data Sheet UBX-13005287 - R17 Product handling & soldering Page 49 of 57

7.2 Moisture Sensitivity Levels

SARA-U2 modules are Moisture Sensitive Devices (MSD) in accordance to the IPC/JEDEC specification. The Moisture Sensitivity Level (MSL) relates to the packaging and handling precautions required. SARA -U2 modules are rated at MSL level 4. For more information regarding moisture sensitivity levels, labeling, st orage and drying see the u-blox Package Information Guide [16]. For MSL standard see IPC/JEDEC J-STD-020 (can be downloaded from http://www.jedec.org/).

7.3 Reflow soldering

Reflow profiles are to be selected according to u -blox recommendations (see SARA-G3 and SARA-U2 series System Integration Manual [6]). Failure to observe these recommendations can result in severe damage to the device!

7.4 ESD precautions

SARA-U2 modules contain highly sensitive electronic circuitry and are Electrostatic Sensitive Devices (ESD). Handling SARA -U2 modules without proper ESD protection may destroy or damage them permanently. SARA-U2 modules are Electrostatic Sensitive Devices (ESD) and require special ESD precautions typically applied to ESD sensitive components. Table 8 reports the maximum ESD ratings of the SARA-U2 module. Proper ES D handling and packaging procedures must be applied throughout the processing, handling and operation of any application that incorporates SARA-U2 module. ESD precautions should be implemented on the application board where the module is mounted, as described in SARA-G3 and SARA-U2 series System Integration Manual [6]. Failure to observe these precautions can result in severe damage to the device!

SARA-U2 series - Data Sheet UBX-13005287 - R17 Default settings Page 50 of 57

8 Default settings

Interface AT settings Comments UART interface Enabled Multiplexing mode can be enabled by AT+CMUX command providing following channels:  Channel 0: control channel  Channel 1 – 5: AT commands / data connection  Channel 6: GNSS tunneling  Channel 7: SAP (SIM Access Profile) AT+IPR=0 One-shot automatic baud rate detection enabled AT+ICF=3,1 Frame format: 8 bits, no parity, 1 stop bit Where AT+IPR=0 is the default value, the AT+ICF value in the profile is not applied (AT+IPR=0 overrules the AT+ICF setting) and the one-shot automatic frame detection is active. AT&K3 HW flow control enabled AT&S1 DSR line set ON in data mode and set OFF in command mode AT&D1 Upon an ON-to-OFF transition of DTR, the module enters online command state and issues an OK result code AT&C1 Circuit 109 changes in accordance with the Carrier detect status; ON if the Carrier is detected, OFF otherwise AUX UART interface Disabled AT command interface is by default disabled on the AUX UART physical interface, and it can be configured by AT+USIO command (see u-blox AT Commands Manual [4]) USB interface Enabled 7 USB CDCs (Communications Device Class) by default available:  USB1: AT and data  USB2: AT and data  USB3: AT and data  USB4: GNSS tunneling  USB5: Primary Log (diagnostic purpose)  USB6: Secondary Log (diagnostic purpose)  USB7: SAP (SIM Access Profile) AT&K3 HW flow control enabled AT&S1 DSR line set ON in data mode and set OFF in command mode AT&D1 Upon an ON-to-OFF transition of DTR, the module enters online command state and issues an OK result code AT&C1 Circuit 109 changes in accordance with the Carrier detect status; ON if the Carrier is detected, OFF otherwise Power saving AT+UPSV=0 Disabled Network registration AT+COPS=0 Self network registration Table 31: SARA-U2 series default settings See the u-blox AT Commands Manual [4] and the SARA-G3 and SARA-U2 series System Integration Manual [6] for information about further settings.

SARA-U2 series - Data Sheet UBX-13005287 - R17 Labeling and ordering information Page 51 of 57

9 Labeling and ordering information

9.1 Product labeling

The labels of SARA-U2 series modules include important product information as described in this section. Figure 18 illustrates the label of all the SARA -U2 series modules except for SARA -U201 ATEX and SARA-U270 ATEX, and includes: u -blox logo, production lot, Pb -free markin g, product Type Number, IMEI number, certification info and production country. SARA-U2xx xxx-xx Figure 18: SARA-U2 series modules label Figure 19 and Figure 20 illustrate the label of SARA -U201 ATEX and SARA -U270 ATEX modules respectively; these include: u-blox logo, production lot, Pb -free marking, product Type Numbe r, IMEI number, ATEX marking with the IECEx and ATEX certificate numbers and category classification. SARA-U201 03X-00

1304 SIQ 16 ATEX 298 U

IECEx SIQ 16.0006U II 1G, Ex ia IIB Figure 19: SARA-U201 ATEX modules label

SARA-U2 series - Data Sheet UBX-13005287 - R17 Labeling and ordering information Page 52 of 57 SIQ 15 ATEX 017 U IECEx SIQ 15.0001U II 1G Ex ia IIC/IIB SARA-U270 00X-00 1304 Figure 20: SARA-U270 ATEX modules label For information about the approval codes and for all the certificates of compliancy of SARA-U2 series modules, see our website (www.u-blox.com) or please contact the u-blox office or sales representative nearest you.

9.2 Explanation of codes

Three different product code formats are used. The Product Name is used in documentation such as thi s data sheet and identifies all the u -blox products, independent of packaging and quality grade. The Ordering Code includes options and quality, while the Type Number includes the hardware and firmware versions. Table 32 details these 3 different formats: Format Structure Product Name SARA-TGVV Ordering Code SARA-TGVV-TTQ Type Number SARA-TGVV-TTQ-XX Table 32: Product code formats Table 33 explains the parts of the product code. Code Meaning Example PPP(P) Form factor (3 or 4 digit, typically 4 for cellular products) SARA TG Platform (Technology and Generation)  Dominant technology: G: GSM/GPRS; U: UMTS/HSPA; C: CDMA 1xRTT; N: NB -IoT; R: LTE low data rate (Cat 1 and below); L: LTE high data rate (Cat 3 and above)  Generation: 1…9 VV Variant function set based on the same platform [00…99] 00 TT Major product version [00…99] 00 Q Quality grade/production site  A = automotive  B = professional  S = professional  X = ATEX S XX Minor product version (not relevant for certification) Default value is 00 Table 33: Part identification code

SARA-U2 series - Data Sheet UBX-13005287 - R17 Labeling and ordering information Page 53 of 57

9.3 Ordering information

Ordering No. Product SARA-U201-03B UMTS/HSPA 800/850/900/1900/2100 MHz and GPRS/EDGE 850/900/1800/1900 MHz bands for worldwide use, 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-U201-63B UMTS/HSPA 800/850/900/1900/2100 MHz and GPRS/EDGE 850/900/1800/1900 MHz bands for worldwide use, approved by NTT DoCoMo Japanese network operator 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-U201-03X UMTS/HSPA 800/850/900/1900/2100 MHz and GPRS/EDGE 850/900/1800/1900 MHz bands for worldwide use, ATEX certified, 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-U201-04B UMTS/HSPA 800/850/900/1900/2100 MHz and GPRS/EDGE 850/900/1800/1900 MHz bands for worldwide use, 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-U201-04X UMTS/HSPA 800/850/900/1900/2100 MHz and GPRS/EDGE 850/900/1800/1900 MHz bands for worldwide use, ATEX certified, 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-U260-00S UMTS/HSPA 850/1900 MHz and GSM/EGPRS 850/1900 MHz bands for America, 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-U260-03S UMTS/HSPA 850/1900 MHz and GSM/EGPRS 850/1900 MHz bands for America, 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-U270-00S UMTS/HSPA 900/2100 MHz and GSM/EGPRS 900/1800 MHz bands for Europe, Asia and other countries, 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-U270-03S UMTS/HSPA 900/2100 MHz and GSM/EGPRS 900/1800 MHz bands for Europe, Asia and other countries, 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-U270-53S UMTS/HSPA 900/2100 MHz bands, approved by KT Korean network operator, 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-U270-73S UMTS/HSPA 900/2100 MHz bands, approved by SKT Korean network operator, 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-U270-00X UMTS/HSPA 900/2100 MHz and GSM/EGPRS 900/1800 MHz bands for Europe, Asia and other countries, ATEX certified, 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-U280-00S UMTS/HSPA 850/1900 MHz bands for America, 26.0 x 16.0 x 3.0 mm, 250 pcs/reel SARA-U280-03S UMTS/HSPA 850/1900 MHz bands for America, 26.0 x 16.0 x 3.0 mm, 250 pcs/reel Table 34: Product ordering codes

SARA-U2 series - Data Sheet UBX-13005287 - R17 Appendix Page 54 of 57 Appendix A Glossary Name Definition ACM Abstract Control Model ADC Analog to Digital Converter ATEX Atmospheres Explosive BER Bit Error Rate CDC Communications Device Class DDC Display Data Channel (I C compatible) Interface DL Down-link (Reception) Driver Class Output Driver Class: see Table 19 for definition DRX Discontinuous Reception ECM Ethernet networking Control Model EDGE Enhanced Data rates for GSM Evolution ERS External Reset Input Signal GDI Generic Digital Interfaces (V_INT supply power domain) GND Ground GNSS Global Navigation Satellite System GPIO General Purpose Input Output GPRS General Packet Radio Service GSM Global System for Mobile communications H High logic digital level HSDPA High Speed Downlink Packet Access HSUPA High Speed Uplink Packet Access I C Inter-Integrated Circuit Interface I S Inter-IC Sound Interface L Low logic digital level LGA Land Grid Array N/A Not Applicable PCN / IN Product Change Notification / Information Note PD Pull-Down POS Power-On Input Signal (power domain) PU Pull-Up PU/PD Class Pull-Up / Pull-Down Class: see Table 19 for definition RMC Reference Measurement Channel SIM SIM Interface (power domain) SPI Serial Peripheral Interface T Tristate (Output of the pin set to tri-state, i.e. high impedance state) T/PD Tristate with internal active Pull-Down enabled T/PU Tristate with internal active Pull-Up enabled TBD To Be Defined UART Universal Asynchronous Receiver-Transmitter serial interface UL Up-link (Transmission) UMTS Universal Mobile Telecommunications System USB Universal Serial Bus (power domain) Table 35: Explanation of abbreviations and terms used

SARA-U2 series - Data Sheet UBX-13005287 - R17 Related documents Page 55 of 57 Related documents [1] 3GPP TS 27.007 - AT command set for User Equipment (UE) [2] 3GPP TS 27.005 - Use of Data Terminal Equipment - Data Circuit terminating Equipment (DTE - DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS) [3] 3GPP TS 27.010 - Terminal Equipment to User Equipment (TE-UE) multiplexer protocol [4] u-blox AT Commands Manual, Docu No UBX-13002752 [5] u-blox Android RIL Production delivery Application note, Docu No UBX-13002041 [6] u-blox SARA-G3 and SARA-U2 series System Integration Manual, Docu No UBX-13000995 [7] u-blox GNSS Implementation Application Note, Docu No UBX-13001849 [8] 3GPP TS 26.267 eCall Data Transfer; In-band modem solution; General description [9] 3GPP TS44.031 Location Services (LCS); Mobile Station (MS) - Serving Mobile Location Centre (SMLC) Radio Resource LCS Protocol (RRLP) [10] ITU-T Recommenda tion V24, 02 -2000. List of definitions for interchange circuits between Data Terminal Equipment (DTE) and Data Connection Equipment (DCE) [11] u-blox Mux Implementation Application Note for wireless modules, Docu No UBX-13001887 [12] I C-bus specification and user manual - Rev. 5 - 9 October 2012 - NXP Semiconductors, http://www.nxp.com/documents/user_manual/UM10204.pdf [13] 3GPP TS 34.121-1 - User Equipment conformance specification; Radio transmission and reception (FDD); Part 1: Conformance specification [14] 3GPP TS 51.010-1 - Mobile Station conformance specification; Part 1: Conformance specification [15] Universal Serial Bus Revision 2.0 specification, http://www.usb.org/developers/docs/usb20_docs/ [16] u-blox Package Information Guide, Docu No UBX-14001652 [17] 3GPP TS 25.331 Radio Resource Control (RRC); Protocol specification [18] GSMA IoT Device Connection Efficiency Guidelines For regular updates to u -blox documentation and to receive product change notifications, register on our homepage.

SARA-U2 series - Data Sheet Page 56 of 57

Revision history

Revision Date Name Comments R01 22-Jan-2014 sfal / sses Initial release R02 29-Apr-2014 sses Updated: receiver sensitivity performance, normal operating temperature range, maximum ESD ratings, USB audio device class support, GPIO configuration table. R03 20-Jun-2014 sses Advance Information document status. Added VCC current consumption characteristics. R04 18-Jul-2014 sses Early Production Information document status. Added VCC current consumption characteristics for 3G Tx/Rx connected modes. R05 10-Apr-2015 sfal Extended the document applicability to SARA-U270 ATEX; removed SARA-U290 and audio over USB feature; updated list of approvals and product labeling R06 15-May-2015 sfal Extended applicability to product version “03” and related features R07 26-Jun-2015 lpah Advance Information document status. R08 10-Aug-2015 sfal Early Production Information document status Extended applicability to SARA-U270-53S R09 02-Dec-2015 sses Document status reverted to Objective Specification Extended applicability to SARA-U201-03A and SARA-U201-03B R10 25-May-2016 lpah / sfal Added SARA-U260-00S-01, SARA-U270-00S-01 Removed SARA-U260-00S-00 Added SARA-U201 ATEX and updated SARA-U201 electrical specification values R11 08-Jul-2016 lpah / sfal Document status updated to Advance Information R12 30-Aug-2016 lpah Document status updated to Early Production R13 07-Oct-2016 lpah Document status reverted to Advance Information Extended applicability to SARA-U270-73S Removed the applicability to SARA-U201-03A R14 14-Dec-2016 lpah "Disclosure restriction" replaces "Document status" on page 2 and document footer R15 03-Aug-2017 lpah Extended applicability to SARA-U270-53S-01 Updated label and approvals information R16 20-Sep-2017 lpah / sses Extended applicability to SARA-U201 modules "63" and "04" product versions R17 31-Oct-2017 lpah / sses Updated SARA-U201-04B / SARA-U201-04X product status

SARA-U2 series - Data Sheet UBX-13005287 - R17 Contact Page 57 of 57 Contact For complete contact information visit us at http://www.u-blox.com/ u-blox Offices North, Central and South America u-blox America, Inc. Phone: +1 703 483 3180 E-mail: info_us@u-blox.com Regional Office West Coast: Phone: +1 408 573 3640 E-mail: info_us@u-blox.com Technical Support: Phone: +1 703 483 3185 E-mail: support_us@u-blox.com Headquarters Europe, Middle East, Africa u-blox AG Phone: +41 44 722 74 44 E-mail: info@u-blox.com Support: support@u-blox.com Documentation Feedback E-mail: docsupport@u-blox.com Asia, Australia, Pacific u-blox Singapore Pte. Ltd. Phone: +65 6734 3811 E-mail: info_ap@u-blox.com Support: support_ap@u-blox.com Regional Office Australia: Phone: +61 2 8448 2016 E-mail: info_anz@u-blox.com Support: support_ap@u-blox.com Regional Office China (Beijing): Phone: +86 10 68 133 545 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office China (Chongqing): Phone: +86 23 6815 1588 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office China (Shanghai): Phone: +86 21 6090 4832 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office China (Shenzhen): Phone: +86 755 8627 1083 E-mail: info_cn@u-blox.com Support: support_cn@u-blox.com Regional Office India: Phone: +91 80 4050 9200 E-mail: info_in@u-blox.com Support: support_in@u-blox.com Regional Office Japan (Osaka): Phone: +81 6 6941 3660 E-mail: info_jp@u-blox.com Support: support_jp@u-blox.com Regional Office Japan (Tokyo): Phone: +81 3 5775 3850 E-mail: info_jp@u-blox.com Support: support_jp@u-blox.com Regional Office Korea: Phone: +82 2 542 0861 E-mail: info_kr@u-blox.com Support: support_kr@u-blox.com Regional Office Taiwan: Phone: +886 2 2657 1090 E-mail: info_tw@u-blox.com Support: support_tw@u-blox.com