Radar-Based Dual-Zone Narrow-Beam Sensors for Detection of Moving and Stationary Targets

  • Fourth generation FMCW (true-presence) radar detects moving and stationary objects
  • Narrow beam pattern Two independent, adjustable sensing zones
  • Easy setup and configuration of range, sensitivity, and output with simple DIP switches
  • Sensing functions are unaffected by wind, falling rain or snow, fog, humidity, air temperatures, or light
  • Sensor operates in Industrial, Scientific, and Medical (ISM) telecommunication band
  • Rugged IP67 housing withstands harsh environments Protected by US patents CAUTION: Make No Modifications to this Product Any modifications to this product not expressly approved by Banner Engineering could void the user's authority to operate the product. Contact Banner Engineering for more information. WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Models1 Maximum Range Connection Supply Voltage Telecom Approval 2 Output QT50R-US-AF2W 24 m (78 ft) 5-wire 2 m (6.5 ft) Integral cable 12 to 30 V dc Telecom approved for US, Canada and Brazil DIP-switch- selectable NPN or PNP and N.O. or N.C. QT50R-EU-AF2W Telecom approved for Europe, UK, Australia, New Zealand, China, and Japan QT50R-KR-AF2W 12 to 24 V dc Telecom approved for South Korea QT50R-TW-AF2W 12 to 30 V dc Telecom approved for Taiwan 1 Cabled models only are listed. For integral 5-pin Euro-style (M12) quick-disconnect fitting, add suffix "Q" to the model number (for example, QT50R-xx-AF2WQ). QD models require a mating cordset; see Quick Disconnect (QD) Cordsets on page 2 For additional countries, contact Banner Engineering. R-GAGE® QT50R-AF2W Sensor Original Document 162360 Rev. F

17 August 2016

sensor can be configured to two independent sensing zones. sensor. The sensor is plug-in ready for immediate operation. Figure 1. R-GAGE features

  1. Power LED: Green (power ON)
  2. Output LEDs: Yellow (output

Figure 2. R-GAGE setpoint distances back of the sensor and access the DIP switches.

6 Dual NPN/PNP output functionality

7 Normally Open/Normally Closed output functionality

8 Response Speed

DIP switch 1 is on the left and DIP switch 8 is on the right.

  • Default settings Switch 1 Switch 2 Switch 3 EU, KR Models TW, US Models All Zone 1 Zone 1 Zone 2 0 0 0 3 m (9.8 ft) 3.5 m (11.5 ft) 8 m (26.2 ft) 0 0 1 4 m (13.1 ft) 4 m (13.1 ft) 10 m (32.8 ft) 0 1 0 6 m (19.7 ft) 6 m (19.7 ft) 12 m (39.4 ft) 0 1 1 8 m (26.2 ft) 8 m (26.2 ft) 16 m (52.5 ft) 1* 0* 0* 8 m (26.2 ft) 8 m (26.2 ft) 20 m (65.6 ft) 1 0 1 10 m (32.8 ft) 10 m (32.8 ft) 20 m (65.6 ft) 1 1 0 10 m (32.8 ft) 10 m (32.8 ft) 24 m (78.7 ft) 1 1 1 12 m (39.4 ft) 12 m (39.4 ft) 24 m (78.7 ft) NOTE: Highest sensitivity is achieved only if sensing distance is 8 m (26.2 ft) or less Sensitivity Selection * Default settings Switch 4 Switch 5 Sensitivity 0* 0* 4 (Highest) 0 1 3 (High) 1 0 2 (Medium) 1 1 1 (Low) Output Configuration * Default settings Switch 6 NPN / PNP 0* NPN

1 PNP

0* NO 1 NC Response Speed * Default settings Switch 8 On Total Off Total Total 0 30 70 100 1* 50 300 350 R-GAGE® QT50R-AF2W Sensor P/N 162360 Rev. F www.bannerengineering.com - Tel: +1-763-544-3164 3

The sensor is able to detect a proper object (see Detectable Objects) from 1 to 24 m (3.3 to 78.7 ft), depending on target Detectable Objects Objects containing metal, water, or similar high-dielectric materials Operating Principle Frequency modulated continuous-wave (FMCW) radar Operating Frequency US, TW Models: 24.075–24.175 GHz, ISM Band EU, KR Models: 24.050–24.250 GHz, ISM Band Supply Voltage 12 to 30 V dc, less than 100 mA, exclusive of load For KR models: 12 to 24 V dc, less than 100 mA exclusive of load Supply Protection Circuitry Protected against reverse polarity and transient overvoltages Delay at Power-up Less than 2 seconds Output Configuration DIP switch 6 selects dual NPN (default) or dual PNP operation; DIP switch 7 selects N.O. (default) or N.C. operation; 150mA each

  • Zone 1 output: white wire
  • Zone 2 output: black wire Output Protection Protected against short circuit conditions Response Time DIP switch 8 selects ON/OFF response time IndicatorsInicators Power LED: Green (power ON) Signal Strength LED: Red, flashes in proportion to signal strength. Steady on at 4x excess gain. Only indicates signal amplitude, not target distance. Output LEDs: Yellow (output energized) / Red (configuration) See Figure 1 on page Adjustments DIP-switch-configurable sensing distance, sensitivity, response time, and output configuration Construction Housing: ABS/polycarbonate Lightpipes: Acrylic Access Cap: Polyester Operating Temperature Environmental Rating IEC IP67 Connections Integral 5-wire 2 m (6.5 ft) cable or M12 Euro-style QD fitting. QD models require a mating cordset Certifications ETSI/EN 300 440 FCC part 15 RSS-210 ANATEL Category II CMIIT Category G ARIB STD T-73 KC mark - MSIP/RRA NCC for others, contact Banner Engineering Country of Origin: USA FCC ID: UE3QT50RUS—This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IC: 7044A-QR50RCA—This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme aux CNR exempts de licence d'Industrie Canada. Son fonctionnement est soumis aux deux conditions suivantes:(1) Ce dispositif ne peut causer des interférences; et(2) Ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent entraîner un mauvais fonctionnement de l'appareil. Este equipamento opera em caráter secundário, isto é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. SRD24-IO3B24100.2TR0.1 South Korea Class A Certification A 급 기기 ( 업무용 방송통신기자재 ) 이 기기는 업무용 (A 급 ) 으로 전자파적합기기로 서 판매자 또는 사용자는 이 점을 주의하시기 바라며 , 가정외의 지역에서 사용하는 것을 목 적으로 합니다 . R-GAGE® QT50R-AF2W Sensor 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 162360 Rev. F

10.2" 41 mm 1.6" 89 mm 3.5" 66 mm 2.6" 54 mm 2.1" 120 mm 4.7" 105 mm 4.1" 208 mm 8.2" 23 mm 0.9" 3 mm 0.1" Ø68 mm 2.7"

4 X Ø5 mm

0.2" Beam Pattern Typical Beam Pattern (with BRTR-CC20E Radar Target, Radar Cross Section = 50 m2) Typical Beam Pattern (with 4 different targets) at highest sensitivity level Left-Right Beam Pattern 5 m -5 m -10 m 10 m 5 m0 10 m 15 m 20 m 25 m 2 3 4 Sensitivity 4 Sensitivity 1 Distance Left-Right Beam Pattern 0 5 m 10 m 15 m 20 m 25 m 5 m 10 m -10 m -5 m Distance 1–4: Indicates sensitivity level 1: Weak Object (Radar cross section = 0.25 m2) 2: Car (Radar cross section = 3 m2) 3: Large Truck (Radar cross section = 50 m2) 4: Passenger Train (Radar cross section = 300 m2) NOTE: The effective beam pattern depends on the sensitivity level and target properties. Windows The R-GAGE sensor can be placed behind a glass or a plastic window, but the configuration must be tested and the distance from the sensor to the window must be determined and controlled prior to installation. There is typically a 20% signal reduction when the sensor is placed behind a window. R-GAGE® QT50R-AF2W Sensor P/N 162360 Rev. F www.bannerengineering.com - Tel: +1-763-544-3164 5

Polycarbonate at 4 mm thickness performs well in most situations, but the performance depends on filler materials. Thinner (1 to 3 mm) windows have high reflection. The amount of reflection depends on the material, thickness, and distance from the sensor to the window. Locate the sensor in a position of minimum reflection from the window, which will repeat every 6.1 mm of distance between the sensor and the window. The positions of maximum reflection from the window repeat between the minimums, and decrease in effect until the window is approximately 150 mm (5.9 in) away. Consult the factory for pre-tested window materials which can be used at any distance without issue. Additionally, the face of the window should be protected from flowing water and ice by use of a flow diverter or hood directly above the window. Falling rain or snow in the air in front of the window, light water mist, or small beads on the face of the window are typically not an issue. However, a thick, continuous surface of water or ice directly on the face of the window can be detected as a dielectric boundary. Weather The R-GAGE sensor can be used in the extreme weather conditions found in port harbors and near oceans. The water in the air does not affect the radar beam, but thick water or ice on the face of the radome can affect performance. In heavy rain or ice conditions, to prevent build-up of water or ice on the radome, use the SAQT50R-91611 accessory. This is a hydrophobic end cap that is easily attached over the sensor radome. This end cap, which is field-replaceable, will take the regular wear and tear from port operation to protect the sensor radome and prolong the life of the radar sensor. Wiring shield (QD cordset) 12-30V dc Load 1 Load 2 Wiring Key: 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray (Do not connect NOTE: Banner recommends that the shield wire (quick disconnect (QD) fitting cordsets only) be connected to earth ground or dc common. Shielded cordsets are recommended for all QD models. Accessories Quick Disconnect (QD) Cordsets 5-Pin Threaded M12/Euro-Style Cordsets—with Shield Model Length Style Dimensions Pinout (Female) MQDEC2-506 1.83 m (6 ft) Straight 44 Typ. ø 14.5 M12 x 1 2 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray MQDEC2-515 4.57 m (15 ft) MQDEC2-530 9.14 m (30 ft) MQDEC2-550 15.2 m (50 ft) MQDEC2-506RA 1.83 m (6 ft) Right-Angle 32 Typ. [1.26"] 30 Typ. [1.18"] ø 14.5 [0.57"] M12 x 1 MQDEC2-515RA 4.57 m (15 ft) MQDEC2-530RA 9.14 m (30 ft) MQDEC2-550RA 15.2 m (50 ft) R-GAGE® QT50R-AF2W Sensor 6 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 162360 Rev. F

NOTE: Pin 5 is not used. Mounting Brackets All measurements are in mm SMB30SC

  • Swivel bracket with 30 mm mounting hole for sensor Black reinforced thermoplastic polyester
  • Stainless steel mounting and swivel locking hardware included B A Hole center spacing: A=ø 50.8 Hole size: A=ø 7.0, B=ø 30.0 SMB30MM
  • 12-ga. stainless steel bracket with curved mounting slots for versatile orientation Clearance for M6 (¼ in) hardware
  • Mounting hole for 30 mm sensor A B C Hole center spacing: A = 51, A to B = 25.4 Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1 Weather Deflector SAQT50R
  • Coated to help repel water and maximize signal strength Mounts using screws for easy application and replacement
  • Required if the R-GAGE is exposed to rain or snow
  • Prevents buildup of water or ice interfering with sensor performance 10.5 mm 27.5 mm 76.2 mm 4x 4-40 UNC Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. For the most recent version of any documentation, refer to: www.bannerengineering.com. R-GAGE® QT50R-AF2W Sensor © Banner Engineering Corp. All rights reserved