Features

 Up to 64 devices supported on a single 600 Series control panel. W i n d o w s®-based field programming.  Dual optically isolated serial ports.  Can interface with building automation systems via standard ASCII communication.  Microprocessor based.  Expandable in 16 point increments to 128 points. Supervised.  Allows remote system control.  Mounting track included. An ISO 9000-2000 Company 7120-1288:149 SIGNALING S521 SAN, SAN-RC Microsoft® Windows® is a registered trademark of Microsoft® Corporation. gwf2027ph1.wmf

12 Clintonville Road, Northford, CT 06472-1610 USA  Tel: (203) 484-7161  Fax: (203) 484-7118

CS-2027 Rev. A page 2 of 2 www.gamewell-fci.com provide an isolated RS-232 output from the main CPU of the 600 Series system panels. The IF602 and IF610 panels have built-in RS-232 ports.

Applications

The SAN units provide a means for remote annunciation and control of the system via a simple RS-232 connection. These driver units fit neatly into an annunciator unit and can be used to drive the LED or incandescent lights of a standard or graphic-type annunciator. When it is necessary for remote system control, the SAN-16-RC provides for up to eight inputs for system control. Any or all inputs may be used to customize any given command station’s capabili- ties. The SAN units can also be used to interface with other building systems via ASCII or where dry contacts or a switched output is required. The SAN’s outputs can be used to drive a relay to interface or control virtually any remote point or group of points. Engineer’s Specifications Remote annunciation and control for the main control panel shall be supplied where indicated. Remote annunciation and control shall be accomplished via the RS-232 data communications line. It shall be possible to add up to 64 devices to the communication line. Each device shall be capable of driving up to 128 points. It shall be possible to mix annunciators, printers and LCD alphanumeric displays on a single line without the need for special software. Devices shall not be placement sensitive. All devices shall be individually field programmable and independent from each other. The device shall be Gamewell-FCI part numbers. Specifications Serial Annunciator Driver: Basic SAN and SAN-RC provide 16- point drives. SAN Input Power: 24 VAC/VDC Standby Current: 0.04 A max. Alarm Current: 2.0 A max. Output Power: 0.040 A max. per output. Dimensions: 12” W x 4” H x 2” D (30.5 W x 10.2 H x 5.1 D cm) PDM-16 Point Drive Module Input Power: From SAN Module Standby Current: 0.002 A Alarm Current: 0.002 A

Ordering Information

SAN-16 Serial annunciator driver module, main driver with 16-outputs. SAN-# Serial annunciator driver module, specify number of outputs in 16-point increments (i.e., SAN-32, SAN-48, SAN-128). Includes mounting track and interconnect cables. Contact the Gamewell-FCI Technical Support for details. SAN-16-RC Serial annunciator driver with four-remote control inputs, eight (8) common outputs and 16-outputs. SAN-#-RC Serial annunciator driver with four- remote control inputs, eight (8) common outputs and a specifiable number of outputs in 16-point increments (i.e., SAN-32-RC, SAN-48-RC, SAN-128-RC). Includes mounting track and interconnect cables. Contact Gamewell-FCI Technical Support for details. PDM-16 Point driver module for field-expanding serial annunciator drivers, 16 outputs. SIM-232 Required serial interface module, mounts in

600 Series control 632, 654, and 658 to sup-

ply RS-232 ouputs. Note: This model is not required for use with the IF602 and IF610 Systems. GW70703 Programming cable (Programmed via a Windows ®-based SAN program). Found on the Gamewell-FCI website. Note: This program is only available to Gamewell-FCI authorized distributors.