Switch Mode Power Supply (15/25/35/50/75/100/150/200/350-W Models) S8FS-C High Reliability at a Reasonable Cost. Reliable, Basic Power Supplies That Contribute to Stable Equipment Operation.

  • High Reliability: Enhanced abnormal overvoltage resistance and lightning surge resistance for stable operation even with an unstable input voltage.
  • Long Life: Japanese 105°C electrolytic capacitors are used to achieve stable quality and long life. A reliable 3-year warranty.*
  • Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC
  • Full Lineup: Models are available for the main output voltages and capacities used in FA applications.
  • Global Standards: Conforms to CE (all models), Approved for UL (all models) and CCC (15 to 150-W models).
  • Easy mounting to DIN Rails with Mounting Brackets. * Refer to Period and Terms of Warranty on page 39. Product Lineup Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information on page 2. Refer to Safety Precautions for All Power Supplies and Safety Precautions on page 36. Output voltage (VDC) Power rating

15 W 25 W 35 W 50 W 75 W 100 W 150 W 200 W 350 W

5 V Yes Yes Yes Yes Yes Yes Yes Yes Yes

12 V Yes Yes Yes Yes Yes Yes Yes Yes Yes

15 V Yes Yes Yes Yes Yes Yes Yes --- ---

24 V Yes Yes Yes Yes Yes Yes Yes Yes Yes

36 V --- --- --- --- --- Yes Yes Yes Yes

48 V --- --- --- Yes Yes Yes Yes Yes Yes

(1) (2) (3) (1) Power Rating (2) Output Voltage Code Power rating 015 15 W 025 25 W 035 35 W 050 50 W 075 75 W 100 100 W 150 150 W 200 200 W 350 350 W Code Output voltage (VDC) 05 5 V 12 12 V 15 15 V 24 24 V 36 36 V 48 48 V (3) Configuration Code Terminal Block Direction Blank Models with terminal block facing upward J Models with terminal block facing forward D Models with DIN rail

Ordering Information

Note: For details on normal stock models, contact your nearest OMRON representative. Note: You can use brackets that are sold separately to mount the Power Supplies to DIN Rail. Refer to Mounting Brackets (Order Separately) on page 29. *1. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC. *2. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 120 VAC, 200 to 240 VAC. Power rating Input voltage Output voltage (VDC) Output current Built-in fan Model with terminal block facing upward Model with terminal block facing forward Model wtih DIN rail 15 W 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC *1)

5 V 3 A

--- S8FS-C01505J S8FS-C01505D 12 V 1.3 A S8FS-C01512J S8FS-C01512D

15 V 1 A S8FS-C01515J S8FS-C01515D

24 V 0.7 A S8FS-C01524J S8FS-C01524D 25 W

5 V 5 A S8FS-C02505 S8FS-C02505J S8FS-C02505D

12 V 2.1 A S8FS-C02512 S8FS-C02512J S8FS-C02512D 15 V 1.7 A S8FS-C02515 S8FS-C02515J S8FS-C02515D 24 V 1.1 A S8FS-C02524 S8FS-C02524J S8FS-C02524D 35 W

5 V 7 A S8FS-C03505 S8FS-C03505J S8FS-C03505D

12 V 3 A S8FS-C03512 S8FS-C03512J S8FS-C03512D

15 V 2.4 A S8FS-C03515 S8FS-C03515J S8FS-C03515D 24 V 1.5 A S8FS-C03524 S8FS-C03524J S8FS-C03524D 50 W

5 V 10 A S8FS-C05005 S8FS-C05005J S8FS-C05005D

12 V 4.2 A S8FS-C05012 S8FS-C05012J S8FS-C05012D 15 V 3.4 A S8FS-C05015 S8FS-C05015J S8FS-C05015D 24 V 2.2 A S8FS-C05024 S8FS-C05024J S8FS-C05024D 48 V 1.1 A S8FS-C05048 S8FS-C05048J S8FS-C05048D 75 W

5 V 14 A S8FS-C07505 S8FS-C07505J S8FS-C07505D

12 V 6.2 A S8FS-C07512 S8FS-C07512J S8FS-C07512D

15 V 5 A S8FS-C07515 S8FS-C07515J S8FS-C07515D

24 V 3.2 A S8FS-C07524 S8FS-C07524J S8FS-C07524D 48 V 1.6 A S8FS-C07548 S8FS-C07548J S8FS-C07548D 100 W 100 to 120 VAC, 200 to 240 VAC (allowable range: 85 to 132 VAC, 176 to 264 VAC, or 248 to 373 VDC (Select with the switch.) *2)

5 V 20 A S8FS-C10005 S8FS-C10005J S8FS-C10005D

12 V 8.5 A S8FS-C10012 S8FS-C10012J S8FS-C10012D

15 V 7 A S8FS-C10015 S8FS-C10015J S8FS-C10015D

24 V 4.5 A S8FS-C10024 S8FS-C10024J S8FS-C10024D 36 V 2.8 A S8FS-C10036 S8FS-C10036J S8FS-C10036D 48 V 2.3 A S8FS-C10048 S8FS-C10048J S8FS-C10048D 150 W 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC, 180 to 264 VAC, or 254 to 373 VDC (Select with the switch.) *2)

5 V 26 A S8FS-C15005 S8FS-C15005J S8FS-C15005D

12 V 12.5 A S8FS-C15012 S8FS-C15012J S8FS-C15012D

15 V 10 A S8FS-C15015 S8FS-C15015J S8FS-C15015D

24 V 6.5 A S8FS-C15024 S8FS-C15024J S8FS-C15024D 36 V 4.3 A S8FS-C15036 S8FS-C15036J S8FS-C15036D 48 V 3.3 A S8FS-C15048 S8FS-C15048J S8FS-C15048D 200 W

5 V 40 A S8FS-C20005 S8FS-C20005J S8FS-C20005D

12 V 17 A S8FS-C20012 S8FS-C20012J S8FS-C20012D

24 V 8.8 A S8FS-C20024 S8FS-C20024J S8FS-C20024D 36 V 5.9 A S8FS-C20036 S8FS-C20036J S8FS-C20036D 48 V 4.43 A S8FS-C20048 S8FS-C20048J S8FS-C20048D 350 W

5 V 60 A

-C35005J S8FS-C35005D

12 V 29 A S8FS-C35012 S8FS-C35012J S8FS-C35012D

24 V 14.6 A S8FS-C35024 S8FS-C35024J S8FS-C35024D 36 V 9.7 A S8FS-C35036 S8FS-C35036J S8FS-C35036D 48 V 7.32 A S8FS-C35048 S8FS-C35048J S8FS-C35048D

Ratings, Characteristics, and Functions * Refer to Conditions on page 12. Power rating 15 W Item Output voltage (VDC) 5 V 12 V 15 V 24 V Efficiency * 115 VAC input 80% typ. 84% typ. 84% typ. 85% typ. 230 VAC input 82% typ. 85% typ. 86% typ. 87% typ. Input Voltage range * Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 0.3 A typ. 230 VAC input 0.19 A typ. Power factor --- Leakage current 115 VAC input 0.05 mA 0.05 mA 0.05 mA 0.05 mA 230 VAC input 0.10 mA 0.10 mA 0.10 mA 0.10 mA Inrush current * (for a cold start at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 3 A 1.3 A 1 A 0.7 A Voltage adjustment range * −10% to 10% (with V. ADJ) Ripple & Noise voltage * 100 to 240 VAC input 30 mVp-p max. 30 mVp-p max. 40 mVp-p max. 30 mVp-p max. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperature vari- ation influence 100 to 240 VAC input 0.03%/°C max. Startup time * 115 VAC input 490 ms typ. 500 ms typ. 470 ms typ. 480 ms typ. 230 VAC input 470 ms typ. 480 ms typ. 450 ms typ. 460 ms typ. Hold time * 115 VAC input 14 ms typ. 16 ms typ. 18 ms typ. 15 ms typ. 230 VAC input 83 ms typ. 87 ms typ. 92 ms typ. 79 ms typ. Addi- tional func- tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula- tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Envi- ronment Ambient operating temperature −20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on page 17.) (with no condensation or icing) Storage temperature −40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Reliabil- ity MTBF 135,000 hrs min. Life expectancy * 10 years min. Con- struc- tion Dimensions (W×H×D) Refer to Dimensions on page 23. Weight 150 g max. Cooling fan No Degree of protection --- Stan- dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved Standards UL : cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 RCM (EN61000-6-4) Marine Standards No SEMI No

  • Refer to Conditions on page 12. Power rating 25 W Item Output voltage (VDC) 5 V 12 V 15 V 24 V Efficiency * 115 VAC input 80% typ. 84% typ. 85% typ. 86% typ. 230 VAC input 82% typ. 86% typ. 88% typ. 88% typ. Input Voltage range * Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 0.49 A typ. 230 VAC input 0.3 A typ. Power factor --- Leakage current 115 VAC input 0.10 mA 0.10 mA 0.10 mA 0.10 mA 230 VAC input 0.20 mA 0.20 mA 0.20 mA 0.20 mA Inrush current * (for a cold start at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 5 A 2.1 A 1.7 A 1.1 A Voltage adjustment range * −10% to 10% (with V. ADJ) Ripple & Noise voltage * 100 to 240 VAC input 20 mVp-p max. 20 mVp-p max. 30 mVp-p max. 40 mVp-p max. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperature vari- ation influence 100 to 240 VAC input 0.03%/°C max. Startup time * 115 VAC input 390 ms typ. 340 ms typ. 400 ms typ. 360 ms typ. 230 VAC input 360 ms typ. 350 ms typ. 400 ms typ. 360 ms typ. Hold time * 115 VAC input 17 ms typ. 22 ms typ. 23 ms typ. 21 ms typ. 230 VAC input 103 ms typ. 113 ms typ. 117 ms typ. 112 ms typ. Addi- tional func- tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula- tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Envi- ronment Ambient operating temperature −20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on page 17.) (with no condensation or icing) Storage temperature −40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Reliabil- ity MTBF 135,000 hrs min. Life expectancy * 10 years min. Con- struc- tion Dimensions (W×H×D) Refer to Dimensions on pages 20 and 23. Weight 250 g max. Cooling fan No Degree of protection --- Stan- dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved Standards UL : cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 RCM (EN61000-6-4) Marine Standards No SEMI No
  • Refer to Conditions on page 12. Power rating 35 W Item Output voltage (VDC) 5 V 12 V 15 V 24 V Efficiency * 115 VAC input 81% typ. 83% typ. 84% typ. 87% typ. 230 VAC input 81% typ. 84% typ. 84% typ. 87% typ. Input Voltage range * Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 0.66 A typ. 230 VAC input 0.41 A typ. Power factor --- Leakage current 115 VAC input 0.15 mA 0.15 mA 0.15 mA 0.15 mA 230 VAC input 0.30 mA 0.25 mA 0.25 mA 0.25 mA Inrush current * (for a cold start at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 7 A 3 A 2.4 A 1.5 A Voltage adjustment range * −10% to 10% (with V. ADJ) Ripple & Noise voltage * 100 to 240 VAC input 80 mVp-p max. 90 mVp-p max. 90 mVp-p max. 80 mVp-p max. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperature vari- ation influence 100 to 240 VAC input 0.03%/°C max. Startup time * 115 VAC input 750 ms typ. 750 ms typ. 760 ms typ. 770 ms typ. 230 VAC input 700 ms typ. 690 ms typ. 710 ms typ. 720 ms typ. Hold time * 115 VAC input 13 ms typ. 14 ms typ. 14 ms typ. 15 ms typ. 230 VAC input 74 ms typ. 75 ms typ. 75 ms typ. 79 ms typ. Addi- tional func- tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula- tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Envi- ronment Ambient operating temperature −20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on page 17.) (with no condensation or icing) Storage temperature −40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Reliabil- ity MTBF 135,000 hrs min. Life expectancy * 10 years min. Con- struc- tion Dimensions (W×H×D) Refer to Dimensions on pages 20 and 23. Weight 250 g max. Cooling fan No Degree of protection --- Stan- dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved Standards UL : cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 RCM (EN61000-6-4) Marine Standards No SEMI No
  • Refer to Conditions on page 12. Power rating 50 W Item Output voltage (VDC) 5 V 12 V 15 V 24 V 48 V Input Voltage range * Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 0.97 A typ. 230 VAC input 0.59 A typ. Power factor --- Leakage current Inrush current * (for a cold start at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 10 A 4.2 A 3.4 A 2.2 A 1.1 A Voltage adjustment range * −10% to 10% (with V. ADJ) Ripple & Noise voltage * 100 to 240 VAC Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperature vari- ation influence 100 to 240 VAC input 0.03%/°C max. Addi- tional func- tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula- tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Envi- ronment Ambient operating temperature −20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on page 17.) (with no condensation or icing) Storage temperature −40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Reliabil- ity MTBF 135,000 hrs min. Life expectancy * 10 years min. Con- struc- tion Dimensions (W×H×D) Refer to Dimensions on pages 20 and 24. Weight 300 g max. Cooling fan No Degree of protection --- Stan- dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved Standards UL : cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 RCM (EN61000-6-4) Marine Standards No SEMI No
  • Refer to Conditions on page 12. Power rating 75 W Item Output voltage (VDC) 5 V 12 V 15 V 24 V 48 V Efficiency * Input Voltage range * Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 1.4 A typ. 230 VAC input 0.83 A typ. Power factor --- Leakage current Inrush current * (for a cold start at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 14 A 6.2 A 5 A 3.2 A 1.6 A Voltage adjustment range * −10% to 10% (with V. ADJ) Ripple & Noise voltage * 100 to 240 VAC Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperature vari- ation influence 100 to 240 VAC input 0.03%/°C max. Startup time * Hold time * Addi- tional func- tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula- tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Envi- ronment Ambient operating temperature −20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on page 17.) (with no condensation or icing) Storage temperature −40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Reliabil- ity MTBF 135,000 hrs min. Life expectancy * 10 years min. Con- struc- tion Dimensions (W×H×D) Refer to Dimensions on pages 21 and 24. Weight 350 g max. Cooling fan No Degree of protection --- Stan- dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved Standards UL : cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 RCM (EN61000-6-4) Marine Standards No SEMI No
  • Refer to Conditions on page 12. Power rating 100 W Item Output voltage (VDC) 5 V 12 V 15 V 24 V 36 V 48 V Efficiency * Input Voltage range * Single phase 85 to 132 VAC, 176 to 264 VAC, 248 to 373 VDC Select with the switch. (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 2 A typ. 230 VAC input 1.1 A typ. Power factor --- Leakage current Inrush current * (for a cold start at 25°) 115 VAC input 32 A typ. 230 VAC input 32 A typ. Output Rated Output Current 20 A 8.5 A 7 A 4.5 A 2.8 A 2.3 A Voltage adjustment range * −10% to 10% (with V. ADJ) Ripple & Noise voltage * 100 to 120 VAC/200 to 240 VAC input 70 mVp-p max. 100 mVp-p max. 70 mVp-p max. 120 mVp-p max. 90 mVp-p max. 120 mVp-p max. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperature vari- ation influence 100 to 120 VAC/200 to 240 VAC input 0.03%/°C max. Startup time * Hold time * Addi- tional func- tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula- tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Envi- ronment Ambient operating temperature −20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on page 17.) (with no condensation or icing) Storage temperature −40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Reliabil- ity MTBF 135,000 hrs min. Life expectancy * 10 years min. Con- struc- tion Dimensions (W×H×D) Refer to Dimensions on pages 21 and 24. Weight 400 g max. Cooling fan No Degree of protection --- Stan- dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved Standards UL : cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 RCM (EN61000-6-4) Marine Standards No SEMI No
  • Refer to Conditions on page 12. Power rating 150 W Item Output voltage (VDC) 5 V 12 V 15 V 24 V 36 V 48 V Efficiency * Input Voltage range * Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373 VDC Select with the switch. (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 2.8 A typ. 230 VAC input 1.6 A typ. Power factor --- Leakage current Inrush current * (for a cold start at 25°) 115 VAC input 32 A typ. 230 VAC input 32 A typ. Output Rated Output Current 26 A 12.5 A 10 A 6.5 A 4.3 A 3.3 A Voltage adjustment range * −10% to 10% (with V. ADJ) Ripple & Noise voltage * 100 to 120 VAC/200 to 240 VAC input 50 mVp-p max. 90 mVp-p max. 110 mVp-p max. 100 mVp-p max. 200 mVp-p max. 120 mVp-p max. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperature vari- ation influence 100 to 120 VAC/200 to 240 VAC input 0.03%/°C max. Startup time * Hold time * Addi- tional func- tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula- tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Envi- ronment Ambient operating temperature −20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on page 17.) (with no condensation or icing) Storage temperature −40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Reliabil- ity MTBF 135,000 hrs min. Life expectancy * 10 years min. Con- struc- tion Dimensions (W×H×D) Refer to Dimensions on pages 21 and 24. Weight 500 g max. Cooling fan No Degree of protection --- Stan- dards Harmonic current emissions Conforms to EN 61000-3-2, GB17625.1 EMI Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved Standards UL : cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 CCC: GB4943 Conformed Standards EN: EN 62368-1 OVC II Pol2 RCM (EN61000-6-4) Marine Standards No SEMI No
  • Refer to Conditions on page 12. Power rating 200 W Item Output voltage (VDC) 5 V 12 V 24 V 36 V 48 V Efficiency * Input Voltage range * Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373 VDC Select with the switch. (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 4 A typ. 230 VAC input 2.3 A typ. Power factor --- Leakage current Inrush current * (for a cold start at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 40 A 17 A 8.8 A 5.9 A 4.43 A Voltage adjustment range * −10% to 10% (with V. ADJ) Ripple & Noise voltage * 100 to 120 VAC/200 Input variation influence * 0.5% max. Load variation influence * 1.0% max. Temperature vari- ation influence 100 to 120 VAC/200 to 240 VAC input 0.03%/°C max. Startup time * Hold time * Addi- tional func- tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula- tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Envi- ronment Ambient operating temperature −20 to 50°C (Derating is required according to the temperature. Refer to Derating Curves on page 17.) (with no condensation or icing) Storage temperature −40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Reliabil- ity MTBF 135,000 hrs min. Life expectancy * 10 years min. Con- struc- tion Dimensions (W×H×D) Refer to Dimensions on pages 22 and 25. Weight 700 g max. Cooling fan No Degree of protection --- Stan- dards Harmonic current emissions --- EMI Conducted Emis- sions Conforms to EN 61204-3 Class A, EN 55011 Class A Radiated Emis- sions Conforms to EN 61204-3 Class A, EN 55011 Class A EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved Standards UL : cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 Conformed Standards EN: EN 62368-1 OVC II Pol2 RCM (EN61000-6-4) Marine Standards No SEMI No
  • Refer to Conditions on page 12. Power rating 350 W Item Output voltage (VDC) 5 V 12 V 24 V 36 V 48 V Efficiency * Input Voltage range * Single phase 90 to 132 VAC , Single phase 180 to 264 VAC , 254 to 373 VDC Select with the switch. (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.) Frequency * 50 /60 Hz (47 to 450 Hz) Current * 115 VAC input 6.4 A typ. 230 VAC input 3.5 A typ. Power factor --- Leakage current Inrush current * (for a cold start at 25°) 115 VAC input 16 A typ. 230 VAC input 32 A typ. Output Rated Output Current 60 A 29 A 14.6 A 9.7 A 7.32 A Voltage adjustment range * −10% to 10% (with V. ADJ) Ripple & Noise voltage * 100 to 120 VAC/200 to Input variation influence * 0.5% max. Load variation influence * 2.0% max. 1.0% max. Temperature vari- ation influence 100 to 120 VAC/200 to 240 VAC input 0.03%/°C max. Startup time * Hold time * Addi- tional func- tions Overload protection Yes, automatic reset Overvoltage protection * Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection Yes, power shut off (shut off the input voltage and turn on the input again) (Overheat protection when the cooling fan is in an abnormal condition) Series operation Yes (For up to 2 Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) Insula- tion Withstand voltage 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Insulation resistance 100 MΩ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Envi- ronment Ambient operating temperature −20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on page 17.) (with no condensation or icing) Storage temperature −40 to 85°C (with no condensation or icing) Ambient operating humidity 20% to 90% (Storage humidity: 10% to 95%) Vibration resistance 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in ±X, ±Y, ±Z directions Reliabil- ity MTBF 135,000 hrs min. Life expectancy * 10 years min. Con- struc- tion Dimensions (W×H×D) Refer to Dimensions on pages 22 and 25. Weight 800 g max. Cooling fan Yes (ON/OFF control according to internal temperature) Degree of protection --- Stan- dards Harmonic current emissions --- EMI Conducted Emissions Conforms to EN 61204-3 Class A, EN 55011 Class A Radiated Emissions Conforms to EN 61204-3 Class A, EN 55011 Class A EMS Conforms to EN 61204-3 high severity levels Safety Standards Approved Standards UL : cURus UL 62368-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No62368-1 Conformed Standards EN: EN 62368-1 OVC II Pol2 RCM (EN61000-6-4) Marine Standards No SEMI No

Inrush Current, Startup Time, and Output Hold Time Note: Twice the normal input current will flow for a redundant system. Sufficiently check the fusing characteristics of fuses and the operating characteristics of breakers and select fuses and breakers so that external fuses will not burn out or breakers will not operate due to inrush current. Ripple Noise Voltage The specified standard for the ripple voltage noise was measured with the following measurement circuit. Efficiency The value is given for the rated output voltage and rated output current. Input Voltage range Although some inverters give 50/60 Hz as the output frequency, do not use an inverter output as the power source for the Power Supply. Doing so may result in smoking or burning due to internal temperature increases in the Power Supply. If you connect a UPS to the input, do not connect one with a square wave output. Frequency Current The value is given for the rated output voltage and rated output current. Inrush current (for a cold start at 25°C) The value is given for a cold start at 25°C. Refer to following for details. Output Voltage adjustment range If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by 10% or more over the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged. Ripple & Noise voltage The value is given for the rated output voltage and rated output current. The value is for an ambient operating temperature of 25°C. Input variation influence This is the maximum variation in the output voltage when the input voltage is gradually changed within the allowable input voltage range at the rated output voltage and rated output current. Load variation influence This is the value when the output current is changed from 0 A to the rated output current while the input voltage is within the allowable input voltage. Startup time The value is given for the rated output voltage and rated output current. The value is given for a cold start at 25°C. Refer to following for details. Hold time The value is given for the rated output voltage and rated output current. Refer to following for details. Additional functions Overvoltage protection Refer to Overvoltage Protection on page 19 for information on resetting the input power. Reliability Life expectancy Refer to Recommended Replacement Periods and Periodic Replacement for Preventive Maintenance on page 39 for details. Startup time Hold time AC input voltage AC input current Output voltage Inrush current on input application 90% 96.5% Input ON Input OFF S8FS-C Oscilloscope frequency band: 20 MHz Twisted to 12 turns. Load C1: 47 μF C2: 0.1 μF Coaxial cable

Fuse: 3.15 A AC (L) Input AC (N) Rectifier Smoothing circuit S8FS-C015 (15 W) AC (L) Input AC (N) Fuse

25 W: 4 A

35 W: 3.15 A

50 W: 4 A

75 W: 5 A

S8FS-C025 (25 W) S8FS-C035 (35 W) S8FS-C050 (50 W) S8FS-C075 (75 W) Input voltage selector switch 100 to 120 VAC/ 200 to 240 VAC switching Input Fuse: 5 A Voltage detection Overvoltage detection Drive control circuit DC output Rectifier/ smoothing circuit Photocoupler Overcurrent detection Noise filter Inrush current protection Rectifier/ smoothing circuit +VAC (L) AC (N) S8FS-C10012 (100 W) S8FS-C10015 (100 W) S8FS-C10024 (100 W) S8FS-C10036 (100 W) S8FS-C10048 (100 W)

Fuse: 5 A Voltage detection Overvoltage detection Drive control circuit DC output Rectifier/ smoothing circuit Photocoupler Overcurrent detection Noise filter Inrush current protection Rectifier/ smoothing circuit +VAC (L) AC (N) Input voltage selector switch 100 to 120 VAC/ 200 to 240 VAC switching S8FS-C10005 (100 W) S8FS-C150 (150 W) Input Fuse: 8 A Voltage detection Overvoltage detection Drive control circuit DC output Rectifier/ smoothing circuit Photocoupler Overcurrent detection Noise filter Inrush current protection Rectifier/ smoothing circuit +VAC (L) AC (N) Input voltage selector switch 100 to 120 VAC/ 200 to 240 VAC switching S8FS-C200 (200 W)

Fuse: 10 A Voltage detection Overvoltage detection Drive control circuit DC output Rectifier/ smoothing circuit Photocoupler Overcurrent detection Noise filter Inrush current protection Rectifier/ smoothing circuit +VAC (L) AC (N) Input voltage selector switch 100 to 120 VAC/ 200 to 240 VAC switching S8FS-C35024 (350 W) Overheating detection Fan Input Fuse: 10 A Voltage detection Overvoltage detection Drive control circuit DC output Rectifier/ smoothing circuit Photocoupler Overcurrent detection Noise filter Inrush current protection Rectifier/ smoothing circuit +VAC (L) AC (N) Rectifier/ smoothing circuit Input voltage selector switch 100 to 120 VAC/ 200 to 240 VAC switching S8FS-C35005 (350 W) S8FS-C35012 (350 W) S8FS-C35036 (350 W) S8FS-C35048 (350 W)

Construction and Nomenclature Nomenclature *1. The fuse is located on the (L) side. It is not user replaceable. For a DC power input, connect the positive voltage to the L terminal. *2. This is the protective earth terminal specified in the safety standards. Always ground this terminal. *3. The 100-W, 150-W, 200-W, and 350-W models only. *4. Refer to Input Voltage Selector Switch in Safety Precautions on page 36. 15-W Models 25-W, 35-W, 50-W, and 75-W Models 100-W and 150-W Models 200-W and 350-W Models No. Name Function 1 Input terminals (L), (N) Connect the input lines to these terminals. *1 2 Protective Earth Terminal (PE) Connect the ground line to this terminal. *2 3 DC output terminals ( −V), (+V) Connect the load lines to these terminals. 4 Output indicator (DC ON: Green) Lit while the DC output is ON. 5 Output voltage adjuster (V. ADJ) Use to adjust the output voltage. 6 Input voltage selector switch Used to switch the input voltage. *3, *4 S8FS-C100/box1/box1 S8FS-C150/box1/box1 S8FS-C200/box1/box1 S8FS-C350/box1/box1 3 2 S8FS-C025/box1/box1/box1 S8FS-C035/box1/box1/box1 S8FS-C050/box1/box1/box1 S8FS-C075/box1/box1/box1 S8FS-C025/box1/box1 S8FS-C035/box1/box1 S8FS-C050/box1/box1 S8FS-C075/box1/box1 S8FS-C100/box1/box1/box1 S8FS-C150/box1/box1/box1 S8FS-C200/box1/box1/box1 S8FS-C350/box1/box1/box1 3 2 3 2 3 2 3 2 S8FS-C015/box1/box1/box1 3 2 1 3 2

Derating for Ambient Temperatures Note: The internal parts may occasionally deteriorate or be damaged. Use the standard mounting method only. Do not use the Power Supply in the area outside the derating curve. Power rating (1) (2) (1) (1) (3) (4) (5) (7) (1) 12 V (1) (1) (2) (1) (6)

15 V --- ---

(1) (2) (3) (4) (5) (6) (7) −30 −20 −10 0 10 20 30 40 50 60 70 80 110 100 Ambient temperature (°C) Load ratio (%) −30 −20 −10 0 10 20 30 40 50 60 70 80 110 100 Ambient temperature (°C) Load ratio (%) −30 −20 −10 0 10 20 30 40 50 60 70 80 110 100 Ambient temperature (°C) Load ratio (%) −30 −20 −10 0 10 20 30 40 50 60 70 80 110 100 Ambient temperature (°C) Load ratio (%) −30 −20 −10 0 10 20 30 40 50 60 70 80 110 100 Ambient temperature (°C) Load ratio (%) −30 −20 −10 0 10 20 30 40 50 60 70 80 110 100 Ambient temperature (°C) Load ratio (%) −30 −20 −10 0 10 20 30 40 50 60 70 80 110 100 Ambient temperature (°C) Load ratio (%)

Derating for Input Voltages Note: The internal parts may occasionally deteriorate or be damaged. Use the standard mounting method only. Do not use the Power Supply in the area outside the derating curve. Power rating (9) (10) (11) (12) 12 V (8) (9) (10) (11) (12) (13) (14) (15) 85 115 145 175 205 235 265 110 100 Input voltage (Vac) Load ratio (%) 85 95 105 115 125 135 110 100 Load ratio (%) Input voltage (Vac) 175 185 195 205 215 225 235 245 255 265 110 100 Load ratio (%) Input voltage (Vac) 90 100 110 120 130 140 110 100 Load ratio (%) Input voltage (Vac) 180 190 200 210 220 230 240 250 260 270 110 100 Load ratio (%) Input voltage (Vac) 90 100 110 120 130 140 110 100 Input voltage (Vac) Load ratio (%) 180 190 200 210 220 230 240 250 260 270 110 100 Load ratio (%) Input voltage (Vac) 180 190 200 210 220 230 240 250 260 270 110 100 Load ratio (%) Input voltage (Vac)

The load and the Power Supply are automatically protected from short-circuit currents and overcurrent damage by this function. Overload protection is activated if the output current rises above 105% of the rated current. When the output current returns within the rated range, the overload protection is automatically cleared. The values shown in the above diagrams are for reference only. Note: 1. If the Power Supply has been short-circuited or supplied with an overcurrent longer than 10 seconds, the internal parts of the Power Supply may occasionally deteriorate or be damaged. 2. Internal parts may possibly deteriorate or be damaged if the Power Supply is used for applications with frequent inrush current or overloading at the load end. Do not use the Power Supply for such applications. Overvoltage Protection Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the Power Supply fails. When an excessive voltage that is 115% of the rated voltage or more is output, the output voltage is shut OFF, preventing damage to the load due to overvoltage. Reset the input power by turning it OFF for at least three minutes and then turning it back ON again. The values shown in the above diagrams are for reference only. Note: Do not turn ON the power again until the cause of the overvoltage has been removed. Overheat Protection (S8FS-C350 Only) If the internal temperature rises excessively as a result of fan failure or any other reason, the overheat protection circuit will operate to protect internal elements. Reset the input power by turning it OFF for at least three minutes and then turning it back ON again. Intermittent operation Output current (%) 0 10050 Output voltage (V) Overvoltage protection operating Variable rangeRated output voltage +10% −10% 0 V +30% (approx.)Output voltage (V)

Dimensions (Unit: mm) Power Supplies Models with Terminal Block Facing Upward 3.59.5 8.16 20.5 6.5 3.5 40.5 82±1 2817.5 99±1 88.5±0.5 40±0.5 55±0.5 87±0.5 74±0.5 3.5 dia. Side: Two, M3 (Depth: 3 mm max.) Bottom: Two, M3 (Depth: 5 mm max.) Five, M3.5 35±1 3.5 dia. S8FS-C025 (25 W) Panel mounting hole dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Bottom mounting Side mounting Two, M3 88.5±0.5 40±0.5 Two, 3.5 dia. 55±0.5 Two, M3 87±0.5 74±0.5 Two, 3.5 dia. 3.59.5 8.16 20.5 6.5 3.5 45.5 97±1 18.5 99±1 89±0.5 55±0.5 87±0.5 74±0.5 3.5 dia. 4.5 Side: Two, M3 (Depth: 3 mm max.) Bottom: Two, M3 (Depth: 5 mm max.) 3.5 dia. 36±1 Five, M3.5 55.5±0.5 S8FS-C035 (35 W) Panel mounting hole dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Bottom mounting Side mounting Two, M3 89±0.5 55.5±0.5 Two, 3.5 dia. 55±0.5 Two, M3 87±0.5 74±0.5 Two, 3.5 dia. Bottom: Two, M3 (Depth: 5 mm max.) 3.5 dia. Side: Three, M3 (Depth: 6 mm max.) 3.5 dia. Five, M3.5 3.5 9.5 8.16 4.5 6.5 5.25 85.5±0.5 97±1 33±0.5 129±1 122.5±0.5 38±1 13±0.5 18±0.5 3.5 28.5 77±0.532 28.5 120±0.5 S8FS-C050 (50 W) Panel mounting hole dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Bottom mounting Side mounting Two, M3 122.5±0.5 85.5±0.5 Two, 3.5 dia. 33±0.5 Three, M3 120±0.5 13±0.5 77±0.5 Three, 3.5 dia. 18±0.5 9±0.5

Bottom: Two, M3 (Depth: 5 mm max.) 3.5 dia. Side: Three, M3 (Depth: 6 mm max.) 3.5 dia. Seven, M3.5 3.59.5 8.16 4.5 6.5 5.5 84.5±0.5 97±1 159±1 152.5±0.5 38±1 13±0.518±0.5 3.5 10.5 28.5 78±0.5 28.5 150±0.5 117±0.5 S8FS-C075 (75 W) S8FS-C100 (100 W) Panel mounting hole dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Bottom mounting Side mounting Two, M3 152.5±0.5 84.5±0.5 Two, 3.5 dia. 78±0.5 Three, M3 150±0.5 13±0.5 117±0.5 Three, 3.5 dia. 18±0.5 9.5±0.5 Note: The figure shows a 100-W Power Supply. A 75-W Power Supply has 5 terminals. S8FS-C150 (150 W) Panel mounting hole dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Bottom mounting Side mounting Two, M3 192.5±0.5 85.5±0.5 Four, 3.5 dia. 120±0.5 80±0.5 Three, M3 190±0.5 13±0.5 157±0.5 Three, 3.5 dia. 18±0.5 8.5±0.5 Bottom: Four, M3 (Depth: 5 mm max.) 3.5 dia. Side: Three, M3 (Depth: 6 mm max.) Seven, M3.5 9.5 8.16 4.5 6.5 5.25 7.5 85.5±0.5 80±0.5 199±1 192.5±0.5 120±0.5 38±1 13±0.5 18±0.5 3.5 28.5 19.528.5 190±0.5 157±0.5 3.5 97±1 3.5 dia.

Bottom: Four, M4 (Depth: 5 mm max.) Side: Four, M4 (Depth: 6 mm max.) 9.5 8.16 50±0.5 112.5±1 150±0.5 50±1 25±0.5 (12.5) 32.5 212±1 32.5 Nine, M3.5 150±0.5 S8FS-C200 (200 W) Panel mounting hole dimensions Using the screw holes in the Power Supply Bottom mounting Side mounting Four, 4.5 dia. 150±0.5 50±0.5 Four, 4.5 dia. 150±0.5 25±0.5 Bottom: Four, M4 (Depth: 5 mm max.) Side: Four, M4 (Depth: 6 mm max.) 9.5 8.16 34.1 50±0.5 112.5±1 150±0.5 50±1 25±0.5 (12.5) 32.5 41.5 212±1 150±0.532.5 Nine, M3.5 (1.2) S8FS-C350 (350 W) Panel mounting hole dimensions Using the screw holes in the Power Supply Bottom mounting Side mounting Four, 4.5 dia. 150±0.5 50±0.5 Four, 4.5 dia. 150±0.5 25±0.5

Models with Terminal Block Facing Forward 51±1 28±1 78±1 25.4 55±0.5 66.5±0.5 12.5 8.75 7.62 Bottom: Two, M3 (Depth: 4 mm max.) 14 max. Side: Two, M3 (Depth: 3 mm max.) Five, M3 S8FS-C015J (15 W) Panel mounting hole dimensions Using the screw holes in the Power Supply Bottom mounting Side mounting Two, 3.5 dia. 55±0.5 Two, 3.5 dia. 66.5±0.5 Bottom: Two, M3 (Depth: 5 mm max.) 82±1 40±0.5 40.5 35±1 17.5 55±0.5 87±0.5 74±0.5188.2 9.5 99±1 20.5 6.5 3.5 (12) 3.5 Side: Two, M3 (Depth: 3 mm max.) Five, M3.5 3.5 dia. 3.5 dia. 88.5 ±0.5 S8FS-C025J (25 W) Panel mounting hole dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Bottom mounting Side mounting Two, M3 88.5±0.5 40±0.5 Two, 3.5 dia. 55±0.5 Two, M3 87±0.5 74±0.5 Two, 3.5 dia. Bottom: Two, M3 (Depth: 5 mm max.) 97±1 55.5±0.5 45.5 36±1 18.5 55±0.5 87±0.5 74±0.5188.2 9.5 99±1 20.5 4.5 6.5 3.5 3.5 Side: Two, M3 (Depth: 3 mm max.) Five, M3.5 3.5 dia. 3.5 dia. (12) 89±0.5 S8FS-C035J (35 W) Panel mounting hole dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Bottom mounting Side mounting Two, M3 89±0.5 55.5±0.5 Two, 3.5 dia. 55±0.5 Two, M3 87±0.5 74±0.5 Two, 3.5 dia.

Side: Three, M3 (Depth: 6 mm max.) Bottom: Two, M3 (Depth: 5 mm max.) Five, M3.5 3.5 dia. 3.5 dia. (12) 97±1 85.5±0.5 38±1 13±0.5 28.5 33±0.5 120±0.5 77±0.532 28.5 8.2 9.5 122.5±0.5 129±1 4.5 6.5 5.25 3.5 3.5 18±0.5 S8FS-C050J (50 W) Panel mounting hole dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Bottom mounting Side mounting Two, M3 122.5±0.5 85.5±0.5 Two, 3.5 dia. 33±0.5 Three, M3 120±0.5 13±0.5 77±0.5 Three, 3.5 dia. 18±0.5 9±0.5 Side: Three, M3 (Depth: 6 mm max.) Bottom: Two, M3 (Depth: 5 mm max.) Seven, M3.5 3.5 dia. 3.5 dia. (12) 97±1 84.5±0.5 38±1 13±0.5 28.5 150±0.5 117±0.522 28.5 8.2 9.5 152.5±0.5 159±1 4.5 6.5 5.5 3.5 3.5 78±0.5 10.5 18±0.5 S8FS-C075J (75 W) S8FS-C100J (100 W) Panel mounting hole dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Bottom mounting Side mounting Two, M3 152.5±0.5 84.5±0.5 Two, 3.5 dia. 78±0.5 Three, M3 150±0.5 13±0.5 117±0.5 Three, 3.5 dia. 18±0.5 9.5±0.5 Note: The figure shows a 100-W Power Supply. A 75-W Power Supply has 5 terminals. Side: Three, M3 (Depth: 6 mm max.) Bottom: Four, M3 (Depth: 5 mm max.) Seven, M3.5 3.5 dia. (12) 97±1 85.5±0.5 80±0.5 38±1 13±0.5 28.5 190±0.5 157±0.522 28.5 19.5 8.2 9.5 192.5±0.5 120±0.5 199±1 4.5 6.5 5.25 7.5 3.5 3.5 18±0.5 3.5 dia. S8FS-C150J (150 W) Panel mounting hole dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Bottom mounting Side mounting Two, M3 192.5±0.5 85.5±0.5 Four, 3.5 dia. 120±0.5 80±0.5 Three, M3 190±0.5 13±0.5 157±0.5 Three, 3.5 dia. 18±0.5 8.5±0.5

112.5±1 50±0.5 50±1 150±0.5 150±0.5 212±1 32.5 32.5 Side: Four, M4 (Depth: 6 mm max.) Bottom: Four, M4 (Depth: 5 mm max.) Nine, M3.5 25±0.5 (12) (12.5) 8.2 9.5 S8FS-C200J (200 W) Panel mounting hole dimensions Using the screw holes in the Power Supply Bottom mounting Side mounting Four, 4.5 dia. 150±0.5 50±0.5 Four, 4.5 dia. 150±0.5 25±0.5 112.5±1 50±0.5 34.1 41.5 50±1 150±0.5 150±0.5 212±1 32.5 32.5 Side: Four, M4 (Depth: 6 mm max.) Bottom: Four, M4 (Depth: 5 mm max.) Nine, M3.5 25±0.5 (12) (12.5) (1.2) 8.2 9.5 S8FS-C350J (350 W) Panel mounting hole dimensions Using the screw holes in the Power Supply Bottom mounting Side mounting Four, 4.5 dia. 150±0.5 50±0.5 Four, 4.5 dia. 150±0.5 25±0.5

97.4 (12.15) 29.2 28.7 5 max. 4.5 7.6 6.3 25.5 25.5 S8FS-C015D (15 W) S8FS-C025D (25 W) 117.5 (12.1) 36.2 35.2 5 max. 112.5 49.5 32.5 75.5 3.5 9.5 8.2 37.2 35.2 5 max. 5.5 112.5 47.5 49.5 85.5 117.5(12.3) S8FS-C035D (35 W)

S8FS-C050D (50 W) 5147.7(12.1) 39.2 35.2 5 max. 4.5 48.5 48.5 85.5 112.5 9.5 8.2 36.7 5 max. 3.9 49.1 47.9 98.5 165.5 39.2 (12.1) 9.5 8.2 177.7 S8FS-C075D (75 W) S8FS-C100D (100 W) Note: The figure shows a 100-W Power Supply. A 75-W Power Supply has 5 terminals. S8FS-C150D (150 W) 47.9 49.1 5.1 98.5 (12.1) 36.7 5 max.165.5 39.2 9.5 8.2 217.7 5

S8FS-C200D (200 W) 210.5 (12) 49.2 5 max. 51.2 230.7 5 9.5 8.2 4.5 56.25 56.25 94.75 S8FS-C350D (350 W) 210.5 49.2 5 max. 51.2 4.5 (12) 230.7 5 9.5 8.2 56.25 56.25 94.75

Mounting Brackets (Order Separately) Power rating Mounting direction Model 15 W DIN Rail S82Y-FSC015DIN

25 W S82Y-FSC025DIN

25 W S82Y-FSC025DIN-S

35 W S82Y-FSC035DIN-S

50 W S82Y-FSC050DIN-S

150 W S82Y-FSC150DIN-S

Bottom-mounting with L-brackets S82Y-FSC350B (4 brackets) 350 W Two, 3.5 dia. 5 max. 4.5 (Sliding: 7.2 max.) (13) 5 25.5 25.5 53±1 28.7±1 29.2 96.7 94±1 S82Y-FSC015DIN Mounting Method Accessories (2 locations) Be sure to use the accessory screws. Mounting screw tightening torque: 0.48 to

0.59 N·m for M3 screws

Two, 3.5 dia. 5 max. 3.5 (Sliding: 6.2 max.) (12) 5 35.2±1 36.2 49.5 32.5 117.7 112.5±1 78.5±1 S82Y-FSC025DIN Accessories (2 locations) Be sure to use the accessory screws. Mounting screw tightening torque: 0.48 to

4.5 (Sliding: 7.2 max.) 5.5 (Sliding: 8.2 max.) 3.5 dia. (35W) 3.5 dia. (50W) 5 max. 50W 50W 35W 50W 35W 35W (12) (12) 5 35.2±1 37.2 39.2 117.7 147.7 112.5±1 49.5 47.5 48.5 48.5 85.5±1 S82Y-FSC050DIN Accessories (2 locations) Be sure to use the accessory screws. Mounting screw tightening torque: 0.48 to 0.59 N·m for M3 screws Mounting Method 3.9 (Sliding: 6.6 max.) 5.1 (Sliding: 7.8 max.) 5 max. Four, 3.5 dia. 150W 150W 150W 75W/100W 75W/100W 75W/100W (12) (12) 5 36.7±1 39.2 177.7 217.7 165.5±1 47.9 49.1 49.1 98.5±1 47.9 S82Y-FSC150DIN Mounting Method Accessories (4 locations) Be sure to use the accessory screws. Mounting screw tightening torque: 0.48 to 0.59 N·m for M3 screws 200W/350W Four, 4.5 dia. 5 max. 4.5 (Sliding: 7.2 max.) (12) 5 49.2±1 51.2 230.7 210.5±1 56.25 94.75±1 56.25 S82Y-FSC350DIN Mounting Method Accessories (4 locations) Be sure to use the accessory screws. Mounting screw tightening torque: 1.08 to 1.32 N·m for M4 screws

Two, 3.5 dia. 4.5 (Sliding: 7.2 max.) 53±1 38.75 25.5 25.5 (13) 43.2±1 87.2 79.5±1 47.2 S82Y-FSC015DIN-S Mounting Method Accessories (2 locations) Be sure to use the accessory screws. Mounting screw tightening torque: 0.48 to 0.59 N·m for M3 screws Two, 3.5 dia. 3.5 (Sliding: 6.2 max.) 78.5±1 49.5 32.5 45.75 (12) 49.7±1 108.2 98±1 60.2 S82Y-FSC025DIN-S Mounting Method Accessories (2 locations) Be sure to use the accessory screws. Mounting screw tightening torque: 0.48 to Two, 3.5 dia. 5.5 (Sliding: 8.2 max.) 85.5±1 49.5 47.5 46.75 (12) 49.7±1 108.2 98±1 60.2 S82Y-FSC035DIN-S Mounting Method Accessories (2 locations) Be sure to use the accessory screws. Mounting screw tightening torque: 0.48 to 0.59 N·m for M3 screws

Two, 3.5 dia. 4.5 (Sliding: 7.2 max.) 85.5±1 48.5 48.5 48.75 (12) 49.7±1 138.2 98±1 80.2 S82Y-FSC050DIN-S Mounting Method Accessories (2 locations) Be sure to use the accessory screws. Mounting screw tightening torque: 0.48 to 0.59 N·m for M3 screws Four, 3.5 dia. 3.9 (Sliding: 6.6 max.) 98.5±1 47.9 49.1 48.75 75W/100W (12) 51.2±1 168.2 88.7 151±1 S82Y-FSC100DIN-S Mounting Method Accessories (4 locations) Be sure to use the accessory screws. Mounting screw tightening torque: 0.48 to 0.59 N·m for M3 screws Four, 3.5 dia. 5.1 (Sliding: 7.8 max.) 98.5±1 47.9 48.75 (12) 51.2±1 208.2 108.7 151±1 49.1 S82Y-FSC150DIN-S Mounting Method Accessories (4 locations) Be sure to use the accessory screws. Mounting screw tightening torque: 0.48 to 0.59 N·m for M3 screws

Four, M4 4.5 dia. 150±0.5 135±0.5 (R2.2) 11.25 4.4 16.25 15±1 12.5 19.5±1 6.5 18.05±1 135 145 150 S82Y-FSC350B (Four Brackets) Mounting Method Accessories (4 locations) Be sure to use the accessory screws. Mounting screw tightening torque: 1.08 to 1.32 N·m for M4 screws Note: The mounting bracket is available in 200-W and 350-W models. The figure shows a 350-W Power Supply. Panel mounting hole dimensions

For Users of S8JC DIN Rail-mounting Power Supplies If you are using a DIN Rail-mounting S8JC-series Power Supply, you can use a DIN Rail-mounting S8FS-C-series Power Supply or replace it with an S8FS-C-series Power Supply with a Forward-facing Terminal Block and a DIN Rail Mounting Bracket. Table of Corresponding S8JC Power Supplies and S8FS-C@J Power Supplies with DIN Rail Mounting Brackets *1. To mount an S8FS-series Power Supply that is not a DIN Rail-mounting model to a DIN Rail, purchase a DIN Rail-mounting Bracket separately from the Power Supply. *2. Consult with your OMRON representative if you use a 15-W or 35-W S8JC-Z Power Supply with a 48-V output voltage. Power rating S8JC-Z *2 S8JC-ZS S8FS-C Power Supply DIN Rail-mounting Bracket *1 15 W S8JC-Z01505CD S8JC-ZS01505CD-AC2  S8FS-C01505J + S82Y-FSC015DINS8JC-Z01512CD S8JC-ZS01512CD-AC2  S8FS-C01512J S8JC-Z01524CD S8JC-ZS01524CD-AC2  S8FS-C01524J 35 W S8JC-Z03505CD S8JC-ZS03505CD-AC2  S8FS-C03505J + S82Y-FSC050DINS8JC-Z03512CD S8JC-ZS03512CD-AC2  S8FS-C03512J S8JC-Z03524CD S8JC-ZS03524CD-AC2  S8FS-C03524J 50 W S8JC-Z05005CD S8JC-ZS05005CD-AC2  S8FS-C05005J + S82Y-FSC050DIN S8JC-Z05012CD S8JC-ZS05012CD-AC2  S8FS-C05012J S8JC-Z05024CD S8JC-ZS05024CD-AC2  S8FS-C05024J S8JC-Z05048CD ---  S8FS-C05048J 100 W S8JC-Z10005CD S8JC-ZS10005CD-AC2  S8FS-C10005J + S82Y-FSC150DIN S8JC-Z10012CD S8JC-ZS10012CD-AC2  S8FS-C10012J S8JC-Z10024CD S8JC-ZS10024CD-AC2  S8FS-C10024J S8JC-Z10048CD ---  S8FS-C10048J 150 W S8JC-Z15005CD S8JC-ZS15005CD-AC2  S8FS-C15005J + S82Y-FSC150DIN S8JC-Z15012CD S8JC-ZS15012CD-AC2  S8FS-C15012J S8JC-Z15024CD S8JC-ZS15024CD-AC2  S8FS-C15024J S8JC-Z15048CD ---  S8FS-C15048J 350 W S8JC-Z35005CD S8JC-ZS35005CD-AC2  S8FS-C35005J + S82Y-FSC350DINS8JC-Z35012CD S8JC-ZS35012CD-AC2  S8FS-C35012J S8JC-Z35024CD S8JC-ZS35024CD-AC2  S8FS-C35024J

DIN Rail (Order Separately) Note: All units are in millimeters unless otherwise indicated. Note: 1. If there is a possibility that the Power Supply will be subject to vibration or shock, use a steel DIN Rail. Otherwise, metallic filings may result from aluminum abrasion. 2. If there is a possibility of the Power Supply sliding sideways, place an End Plate (PFP-M) on each end of the Power Supply. Terminal Cover (Order Separately) Terminal block direction Power rating Applicable models Terminal Cover model number Models with terminal block facing upward 25-W S8FS-C025 @@ S82Y-FSC-C5 35-W S8FS-C035 @@ 50-W S8FS-C050 @@ 75-W S8FS-C075 @@ 100-W S8FS-C100 @@ S82Y-FSC-C7 150-W S8FS-C150 @@ 200-W S8FS-C200 @@ S82Y-FSC-C9 350-W S8FS-C350 @@ Models with terminal block facing forward 15-W S8FS-C015 @@J/D S82Y-FSC-C5MF 25-W S8FS-C025 @@J/D S82Y-FSC-C5F 35-W S8FS-C035 @@J/D 50-W S8FS-C050 @@J/D 75-W S8FS-C075 @@J/D 100-W S8FS-C100 @@J/D S82Y-FSC-C7F 150-W S8FS-C150 @@J/D 200-W S8FS-C200 @@J/D S82Y-FSC-C9F 350-W S8FS-C350 @@J/D Mounting Rail (Material: Aluminum) 4.5 15 25 25 10 10 1,000 (500)* 25 25 15 (5)* 35±0.3 7.3±0.15 27±0.15 * Value in parentheses are for PFP-50N. Model PFP-100N PFP-50N Mounting Rail (Material: Aluminum) 4.5 15 25 25 10 10 1,000 25 25 15 1 1.5 29.224 27 35±0.3 Model PFP-100N2 1.3 4.8 35.5 35.5 1.8 1.8 M4 spring washer 6.2 11.5 M4 × 8 panhead screw End Plate Model PFP-M

Refer to Safety Precautions for All Power Supplies. Warning Indications Meaning of Product Safety Symbols Minor electric shock, fire, or Product failure may occasionally occur. Do not disassemble, modify, or repair the Product or touch the interior of the Product. Minor burns may occasionally occur. Do not touch the Product while power is being supplied or immediately after power is turned OFF. Fire may occasionally occur. Tighten terminal screws to the specified torque. S8FS-C015@@J: 4.25 to 5.13 lb-in (0.48 to 0.58 N·m) Other than S8FS-C015@@J: 6.55 to 7.78 lb-in (0.74 to 0.88 N·m) Minor injury due to electric shock may occasionally occur. Do not touch the terminals while power is being supplied. Minor electric shock, fire, or Product failure may occasionally occur. Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter the Product. Ambient Operating and Storage Environments

  • Store the Power Supply at a temperature of −40 to 85°C and a humidity of 10% to 95%.
  • The internal parts may occasionally deteriorate or be damaged. Use the standard mounting method only. Do not use the Power Supply outside the derating range.
  • Use the Power Supply at a humidity of 20% to 90%.
  • Do not use the Power Supply in locations subject to direct sunlight.
  • Do not use the Power Supply in locations where liquids, foreign matter, or corrosive gases may enter the interior of the Power Supplies. Installation Environment
  • Do not use the Power Supply in locations subject to shocks or vibrations. Install the Power Supply away from contactors and other parts and devices that are sources of vibration.
  • Install the Power Supply well away from any sources of strong, high-frequency noise and surge. Input Voltage Selector Switch
  • For 100-W or higher models, the input voltage is factory-set to 200 to 240 V. To use an input voltage of 100 to 120 VAC, change the input voltage selector switch to the 100 to 120 VAC setting. To use a DC input, set the input voltage selector switch to the 200 to 240 VAC setting.
  • Minor electric shock may occasionally occur. Do not operate the input voltage selector switch while power is being supplied. Mounting
  • Take adequate measures to ensure proper heat dissipation to increase the long-term reliability of the Power Supply.
  • For models other than the S8FS-C350, be sure to allow convection in the atmosphere around devices when mounting. Do not use the Power Supply in locations where the ambient temperature exceeds the range of the derating curve.
  • For the S8FS-C350: Forced air cooling with a fan is used. Do not allow the ventilation holes to be blocked. The effectiveness of cooling would be reduced.
  • The internal parts may occasionally deteriorate or be damaged. Use the standard mounting method only. Do not use the Power Supply outside the derating range.
  • If you mount the Power Supply by using the screw holes provided on the chassis, the screws should preferably not penetrate beyond the exterior by more than 3 mm inside the Power Supply. If you use screws that are longer than this, make sure that they do not penetrate beyond the depth given in the dimensional diagram. Use the following tightening torque. 0.48 to 0.59 N·m for M3 screws 1.08 to 1.32 N·m for M4 screws
  • When cutting out holes for mounting, make sure that cuttings do not enter the interior of the Power Supplies.
  • The internal parts may occasionally deteriorate or be damaged due to adverse heat radiation. Do not loosen the screws on the Power Supplies. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction or undesirable effect on product performance. Indicates the possibility of electric shock under specific conditions. Indicates the possibility of injuries by high temperature under specific conditions. Indicates the possibility of injuries, such as electric shock by disassembling the device, prohibiting disassembly. Indicates the instructions of unspecified general action. CAUTION Precautions for Safe Use

The standard mounting pattern is shown below. Mounting Pattern A The above figure shows a model with the terminal block facing upward. Mounting Pattern B The above figure shows a model with the terminal block facing upward. Mounting Pattern C *2 The above figure shows a model with the terminal block facing forward. Mounting Pattern D *2 To mount the Power Supply to a DIN Rail, hook portion (A) of the Power Supply onto the DIN Rail and press the Power Supply in direction (B) until you hear it lock into place. Make sure that the catch on the Mounting Bracket is engaged with the DIN Rail. To dismount the Power Supply, pull down portion (C) with a flat-blade screwdriver and pull out the Power Supply. *1. Air flow *2. For mounting patterns C and D, a separately sold Mounting Bracket is used to mount the Power Supplies to DIN Rail. Refer to Mounting Brackets (Order Separately) on page 29 for the separately sold Mounting Brackets. Wiring

  • Connect the ground completely. A protective earthing terminal stipulated in safety standards is used. Electric shock or malfunction may occur if the ground is not connected completely.
  • Minor fire may possibly occur. Ensure that input and output terminals are wired correctly.
  • Do not apply more than 75 N force to the terminal block when tightening it.
  • Be sure to remove the sheet covering the Power Supply for machining before power-ON so that it does not interfere with heat dissipation.
  • Use the following material for the wires to be connected to the S8FS-C to prevent smoking or ignition caused by abnormal loads. Recommended Wire Gauges Note: The current capacity for the output terminals on the S8FS- C025 to S8FS-C350 is 25 A for each terminal. Make sure to use multiple terminals together if the current flow is higher than the current capacity for each terminal. Overload Protection
  • If the Power Supply has been short-circuited or supplied with an overcurrent longer than 10 seconds, the internal parts of the Power Supply may occasionally deteriorate or be damaged.
  • Internal parts may possibly deteriorate or be damaged if the Power Supply is used for applications with frequent inrush current or overloading at the load end. Do not use the Power Supply for such applications. 20 mm min. *1 75 mm min.*1 20 mm min. *1 75 mm min.*1 20 mm min. *1 *1 75 mm min. 20 mm min. 20 mm min. 75 mm min.*1 (B) (A) Rail stopper (C) Terminals Model Recommended Wire Gauges Input S8FS-C015 AWG14 to 22 S8FS-C025 to S8FS-C100 AWG12 to 20 S8FS-C150 or S8FS-C200 AWG12 to 16 S8FS-C350 AWG12 Output S8FS-C015 AWG14 to 18 S8FS-C02512 to S8FS-C02524 AWG12 to 20S8FS-C03515 to S8FS-C03524 S8FS-C05024 to S8FS-C05048 S8FS-C02505 or S8FS-C03512 AWG12 to 16 S8FS-C05012 to S8FS-C05015 S8FS-C07515 to S8FS-C07548 S8FS-C10024 to S8FS-C10048 S8FS-C15036 to S8FS-C15048 S8FS-C03505 or S8FS-C05005 AWG12 S8FS-C07505 to S8FS-C07512 S8FS-C10005 to S8FS-C10015 S8FS-C15005 to S8FS-C15024 S8FS-C200 or S8FS-C350 Protective earth terminal S8FS-C015 AWG14 S8FS-C025 to S8FS-C350 AWG12 to 14

Output Voltage Adjuster (V. ADJ)

  • The output voltage adjuster (V. ADJ) may possibly be damaged if it is turned with unnecessary force. Do not turn the adjuster with excessive force.
  • After completing output voltage adjustment, be sure that the output capacity or output current does not exceed the rated output capacity or rated output current. Series Operation Two Power Supplies can be connected in series. Note: 1. If the load is short-circuited, a reverse voltage will be generated inside the Power Supply. If this occurs the Power Supply may possibly deteriorate or be damaged. Always connect a diode as shown in the figure. Select a diode having the following ratings. 2. Although Power Supplies having different specifications can be connected in series, the current flowing through the load must not exceed the smaller rated output current. Making Positive/Negative Outputs
  • The outputs are floating outputs (i.e., the primary circuits and secondary circuits are separated). You can therefore make positive and negative outputs by using two Power Supplies. You can make positive and negative outputs with any of the models. If positive and negative outputs are used, connect Power Supplies of the same model as shown in the following figure. (Combinations with different output capacities or output voltages can be made. However, use the lower of the two maximum rated output currents as the current to the loads.)
  • Depending on the model, internal circuits may be damaged due to startup failure when the power is turned ON if loads such as a servomotor or operational amplifier operate in series. Therefore, connect bypass diodes (D 1, D2) as shown in the following figure.
  • Select a diode having the following ratings. Parallel Operation Parallel operation is not possible. Backup Operation Backup operation is possible if you use two Power Supplies of the same model. Connect diodes as shown in the following figure for backup operation. Select a diode having the following ratings.
  • The output voltages of Power Supplies A and B output must be set higher only by a value equivalent to the drop in forward voltages F) of diodes D1 and D2.
  • Power loss occurs equivalent to the Power Supply output current OUT) times the diode forward voltage (VF), and heat is generated. The diode must be cooled to ensure that its temperature is kept at or below the value indicated in the diode catalog.
  • There will be a power loss caused by load power and diodes. Be sure that this total power loss does not exceed the rated output power (rated output voltage times rated output current) of each Power Supply. In Case There Is No Output Voltage There is a possibility that functions such as overcurrent protection, over-voltage protection or overheating protection are functioning. The internal protection circuit may operate if a large amount of surge voltage such as a lightening surge occurs while turning ON the Power Supply. In case there is no output voltage, please check the following points before contacting us:
  • Checking overload protection status: Check whether the load is in overload status or is short-circuited. Remove wires to load when checking.
  • Checking overvoltage or internal protection: Turn the power supply OFF once, and leave it OFF for at least 3 minutes. Then turn it ON again to see if this clears the condition.
  • Check overheating protection (350-W model): Switch off the input power supply and switch back on after allowing sufficient time for cooling. Charging Batteries If you connect a battery at the load, install overcurrent control and overvoltage protection circuits. Type Schottky Barrier diode Dielectric strength (VRRM) Twice the rated output voltage or above Forward current (IF) Twice the rated output current or above Type Schottky Barrier diode Dielectric strength (VRRM) Twice the rated output voltage or above Forward current (IF) Twice the rated output current or above Correct AC (L) AC (N) AC (L) AC (N) INPUT +V +V 0 V INPUT LoadLoad INPUT INPUT LoadLoad Load Type Schottky Barrier diode Dielectric strength (VRRM) Twice the rated output voltage or above Forward current (IF) Twice the rated output current or above AC (L) AC (N) AC (L) AC (N) Incorrect Parallel Operation A B Load

Period and Terms of Warranty Warranty Period The Power Supply warranty is valid for a period of three years from the date of shipment from the factory. Terms of Warranty The warranty is valid only for the following operating conditions. 1. Average ambient operating temperature of the Power Supply: 40°C max. 2. Average load rate: 80% max. 3. Mounting method: Standard mounting * The maximum ratings must be within the derating curve. If the Power Supply fails for reasons attributable to OMRON within the above warranty period, OMRON will repair or replace the faulty part of the Power Supply at the place of purchase or the place where the Power Supply delivered without charge. This warranty does not cover the following types of failures. Recommended Replacement Periods and Periodic Replacement for Preventive Maintenance The recommended replacement period for preventive maintenance is greatly influenced by the application environment of the Power Supply. As a guideline, the recommended replacement period is 7 to 10 years.* To prevent failures and accidents that can be caused by using a Power Supply beyond its service life, we recommend that you replace the Power Supply as early as possible within the recommended replacement period. However, bear in mind that the recommended replacement period is for reference only and does not guarantee the life of the Power Supply. Many electronic components are used in the Power Supply and the Power Supply depends on the correct operation of these components to achieve the original Power Supply functions and performance. However, the influence of the ambient temperature on aluminum electrolytic capacitors is large, and the service life is reduced by half for each 10°C rise in temperature (Arrhenius law). When the capacity reduction life of the electrolytic capacitor is reached, Power Supply failures or accidents may occur. We therefore recommend that you replace the Power Supply periodically to minimize Power Supply failures and accidents in advance. * The recommended replacement period applies under the following conditions: rated input voltage, load rate of 50% max., ambient temperature of 40°C max., and the standard mounting method. (The fan is excluded for models with fans.) This product model is designed with a service life of 10 years minimum under the above conditions. (1) Failures that result from handling or operation of the Powe r Supply under conditions or in environments that are not given in this document and not given in any other specifications exchanged between OMRON and the customer (2) Failures that originate in causes other than the delivered product itself (3) Failures caused by disassembly, modification, or repair of the Power Supply by anyone other than OMRON (4) Failures caused by applications or uses for which the Power Supply was not originally intended (5) Failures caused by factors that could not be anticipated with the scientific or technical knowledge available when the Power Supply was shipped (6) Failures caused by other caus es for which OMRON is not responsible, such as natural disasters and other acts of God This warranty is limited to the individual product that was delivered and does not cover any secondary, subsequent, or related damages.

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.

Authorized Distributor: Kyoto, JAPAN Contact : www.ia.omron.com Regional Headquarters OMRON ASIA PACIFIC PTE. LTD. 438B Alexandra Road, #08-01/02 Alexandra Technopark, Singapore 119968 Tel: (65) 6835-3011 Fax: (65) 6835-3011 OMRON ELECTRONICS LLC

2895 Greenspoint Parkway, Suite 200

Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900 Fax: (1) 847-843-7787 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower,

200 Yin Cheng Zhong Road,

PuDong New Area, Shanghai, 200120, China Tel: (86) 21-6023-0333 Fax: (86) 21-5037-2388 OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31) 2356-81-300 Fax: (31) 2356-81-388 Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company Cat. No. T062-E1-07 1123 (0915) ©OMRON Corporation 2015-2023 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_3_3