Switching Power Supply S82K56 Switching Power Supply S82K DIN-Rail Mount Power Supply with a Wide Power Range of 3 to 240 W /C0068Universal input voltage range. /C0068All models are UL 508 listed. /C0068Class 2 approved on all models below 240 W, except dual-output types. /C0068Undervoltage indicators on all 90-W, 100-W and the 240-W “T” models have alarm and output indicators. /C0068PFC models meet EN61000-3-2 (limits for harmonic current emissions). /C0068Parallel operation capability (100 W and 240 W). /C0068Finger-safe terminal block with cover according to VDE0106/P100. /C0068Approvals: UL, CSA, VDE, and CE. /C00683-year warranty. /C0117/C0082

Ordering Information

/C0074SWITCHING POWER SUPPLIES Stock Note: Shaded models are normally stocked. Rated input lt Power ratings Output voltage Output t Function configuration Part numberp voltage g pg p current Output Undervoltage alarm PFC 100 to 240 VAC 3 W 5 V 0.6 A Single tt Indicator only No S82K-00305 12 V 0.25 A g output y S82K-00312 15 V 0.2 A S82K-00315 24 V 0.13 A S82K-00324 7.5 W 5 V 1.5 A S82K-00705 12 V 0.6 A S82K-00712 15 V 0.5 A S82K-00715 24 V 0.3 A S82K-00724 +12 V/–12 V 0.3 A/0.2 A Dual output S82K-00727 p S82K-00728 15 W 5 V 2.5 A Single tt S82K-01505 12 V 1.2 A g output S82K-01512 24 V 0.6 A S82K-01524 (This table continues on the next page.)

57Switching Power Supply S82K Ordering Information Table – continued from previous page Rated input lt Power ratings Output voltage Output t Function configuration Part numberp voltage g pg p current Output Undervoltage alarm PFC 100 to 240 VAC 30 W 5 V 5.0 A Single tt Indicator only No S82K-03005 12 V 2.5 A g output y S82K-03012 24 V 1.3 A S82K-03024 50 W 24 V 2.1 A S82K-05024 120/240 VAC lt b l 90 W 24 V 3.75 A Indicator and tt S82K-P09024 selectable output Yes S82K-09024 100 W 24V 4.2 A No S82K-P10024 Yes S82K-10024 120/230 VAC lt b l

240 W 24 V 10 A No S82K-24024T

selectable None S82K-24024 100 to 230 VAC Yes S82K-P24024 /C0074MODEL NUMBER LEGEND S82K - 1 2 3 4 1. Power Factor Correction None: No P: Yes 2. Power Ratings 003: 3 W 007: 7.5 W 015: 15 W 030: 30 W 050: 50 W 090: 90 W 100: 100 W 240: 240 W 3. Output Voltage 05: +5 VDC 12: +12 VDC 15: +15 VDC 24: +24 VDC 27: Dual output +12/-12 VDC 28: Dual output +15/-15 VDC 4. Undervoltage alarm indicator/output <For 3- to 100-W models> None: Yes <For 240-W models> None:No T: Yes /C0074ACCESSORIES (SOLD SEPARATELY) Stock Note: Shaded models are normally stocked. Noise Filter Item Applicable power supply Part number Noise filter 3- to 50-W models S82Y-JF3-N 90-W and 100-W models S82Y-JF6-N DIN Rail Item Length Width Part number 1 m (3.28 ft) 7.3 mm (0.29 in) PFP-100N 1 m (3.28 ft) 16 mm (0.63 in) PFP-100N2

58 Switching Power Supply S82K

/C0074NON-PFC MODELS Item Single output Dual outputs Single output Power rating 3 W 7.5 W 7.5 W 15 W 30 W 50 W 90 W 100 W 240 W Efficiency (typical) 60% to 80% (Varies depending on specifications.) Input Voltage (See Note 1.) AC 100 to 240 V (85 to 264 V) 120 V (85 to 132 V)/

240 V (170 to 264 V)

120 V (85 to 132 V)/

230 V (170 to 253 V)

Selectable) DC 90 to 350 V (See Note 2.) Not possible Frequency 50/60 Hz (47 to 450 Hz) Current (See N3 ) 100-V input 0.15 A max. 0.25 A max. 0.45 A max. 0.9 A max. 1.3 A max. 2.5 A max. 5.5 A max. (See Note 3.) 200-V input max. 0.25 A max. 0.6 A max. 0.8 A max. 1.5 A max. 3.5 A max. Leakage current 100-V input 0.5 mA max. current (See Note 3.) 200-V input 1 mA max. Inrush current 100-V input 15 A max. 25 A max. current (See Note 3.) 200-V input 30 A max. 50 A max. Noise filter Yes Output (See Note 4.) Voltage adjustment range r10% (V.ADJ) Not pos- sible (See Note 5.) r10% (V.ADJ); –10% to 15% for S82K-03012/-03024/-05024 Ripple (See Note 3.) 2% (p-p) max. Input variation influence 0.5 % max. (at 85 to 264 VAC, 100% load) 0.5 % max. (at 85 to

132 VAC/

170 to 264 VAC input, 100% load) 0.5 % max. (at 85 to

132 VAC/170 to

253 VAC input,

100% load) Load variation influence 1.5% max. (0 to 100% load) +V: 1.5% max. -V: 3 % max. (0 to 100% load) 1.5% max. (0 to 100% load) 1.5% max. (10 to 100% load) Temperature variation influence (See Note 3.) 0.05%/qC max. Startup time 100 ms max. (up to 90% of output voltage at rated input and output) 200 ms max. 300 ms max. Hold time (See Note 3.) 20 ms min. (This table continues on the next page.) Note: 1. Use with DC voltage input is beyond the conditions of approval or conformance to applicable safety standards. 2. Use the 7.5-W single-output models under the load of 90% max. if the voltage range is between 90 and 110 VDC. 3. Defined with a 100% load and the rated input voltage (100 or 200 VAC). 4. The output specification is defined at the power supply output terminals. 5. The settings for the output voltage must be within the following range: +V: r1% of the rated value –V: r5% of the rated value

59Switching Power Supply S82K Specifications Table – continued from previous page Item Single output Dual outputs Single output Power rating 3 W 7.5 W 7.5 W 15 W 30 W 50 W 90 W 100 W 240 W Additional functions Overload protection 105% to 160% (105% to 250% for dual outputs model, 101% to 111% for 90-W model) of rated load current, automatic reset (See Note 6.) Overvoltage protection (See Note 7.) No S82K- 24024T model only Undervoltage alarm indicator (DC LOW indicator) Yes (color: red) S82K- 24024T model only Undervoltage alarm output (DC LOW output) No Yes S82K- 24024T model only Parallel operation Not possible Possible (2 units max.) Characteristics Ambient tt Operating See the derating curve in the Engineering Data section (no condensation or icing) temperature Storage –25qC to 65qC (-13qF to 149qF) with no condensation or icing Ambient hi d i t Operating 25% to 85% humidity Storage 25% to 90% Dielectric strength 3,000 VAC at 50/60 Hz for 1 min (between all inputs and outputs) 2,000 VAC at 50/60 Hz for 1 min (between all inputs and GR terminal) 1,000 VAC at 50/60 Hz for 1 min (between all outputs and GR terminal) Alarm current: 10 mA (3- to 7.5-W models) 20 mA (15- to 100-W models) 25 mA (240-W models) Insulation resistance 100 M: min. at 500 VDC (between all outputs and all inputs/GR terminal) Vibration resistance Malfunction: 10 to 55 Hz, 0.375-mm (0.15-mm for 240-W model) single amplitude for 2 hrs each in X, Y , and Z directions Shock resistance Malfunction: 300 m/s2, 3 times each in rX, rY, and rZ directions Screw tightening torque 0.74 N /C0083 m max. (See Note 8.) Output indicator Yes (green) Electromagnetic interference (See Note 3.) Conforms to FCC class B Conforms to FCC class A (This table continues on the next page.) Note: 1. Use with DC voltage input is beyond the conditions of approval or conformance to applicable safety standards. 2. Use the 7.5-W single-output models under the load of 90% max. if the voltage range is between 90 and 110 VDC. 3. Defined with a 100% load and the rated input voltage (100 or 200 VAC). 4. The output specification is defined at the power supply output terminals. 5. The settings for the output voltage must be within the following range: +V: r1% of the rated value –V: r5% of the rated value 6. When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the protection function will operate at a current of 95% to 160% of the rated load current. When using the 90-W model under the ambient temperature over 25qC, the protection function may operate at a current of 92% to 111% of the rated load current. 7. Circuit-breaker type. To reset, turn the input power supply OFF, then after 1 min has elapsed, turn the input power supply ON again. 8. Do not press down on the terminal block with a force exceeding 75 N while tightening the terminals. 9. To ensure the emission ratings, a noise filter should be used on the output lines at the closest point. (3- to 50-W models: S82Y-JF3-N, 90-W and 100-W models: S82Y-JF6-N) 10. To ensure the Emission Enclosure rating, a ferrite ring core should be used on all cables (for S82K-P24024). 11. To meet Class 2 requirement with 100-W model, either a fuse or circuit breaker that is UL listed or CSA certified, and rated at 4.2 A max. should be used in the output of the power supply. Only then can the power supply output be considered as meeting Class 2.

60 Switching Power Supply S82K

Specifications Table – continued from previous page Item Single output Dual outputs Single output Power rating 3 W 7.5 W 7.5 W 15 W 30 W 50 W 90 W 100 W 240 W Characteristics (continued) EMC (See Note 9.) 3-W to 100-W models (EMI): EN50081-1 Emission Enclosure: EN55022 class B (equivalent to EN55011 class B) Emission AC Mains: EN55022 class B (equivalent to EN55011 class B) Emission Output Ports: EN55022 class A (with a recommended optional filter) (See Note 9.) 240-W models (EMI): EN50081-2 Emission Enclosure: EN55011 class A (See Note 10.) Emission AC Mains: EN55011 class A (See Note 10.) Harmonic Current: EN61000-3-2 (only for S82K-P24024) Common to all models (EMS): EN50082-2 Immunity ESD: EN61000-4-2: 4-kV contact discharge (level 2) 8-kV air discharge (level 3) Immunity Burst: EN61000-4-4: 2-kV power-line (level 3) 2-kV output line (level 4) Immunity Surge: EN61000-4-5: between 2-kV lines (except for 240-W models) between 4-kV line and FG (except for 240-W models) Approved standards UL508 (Listing)/1950; Class 2 Power Supply, CE; CSA C22.2 No.14/No.950; EN50178 (VDE0160), EN60950 (Conforms to VDE0106/P100) * 100-W model must have a fuse in the output to be Class 2. (See Note 11.) UL508 (Listing)/1012; CE; CSA C22.2 No.14, CSA E.B. 1402C; EN50178 (VDE0160), EN60950 (Conforms to VDE106/P100) Weight 150 g max. 260 g max. 380 g max. 400 g max. 600 g max. 1,800 g max. Note: 1. Use with DC voltage input is beyond the conditions of approval or conformance to applicable safety standards. 2. Use the 7.5-W single-output models under the load of 90% max. if the voltage range is between 90 and 110 VDC. 3. Defined with a 100% load and the rated input voltage (100 or 200 VAC). 4. The output specification is defined at the power supply output terminals. 5. The settings for the output voltage must be within the following range: +V: r1% of the rated value –V: r5% of the rated value 6. When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the protection function will operate at a current of 95% to 160% of the rated load current. When using the 90-W model under the ambient temperature over 25qC, the protection function may operate at a current of 92% to 111% of the rated load current. 7. Circuit-breaker type. To reset, turn the input power supply OFF, then after 1 min has elapsed, turn the input power supply ON again. 8. Do not press down on the terminal block with a force exceeding 75 N while tightening the terminals. 9. To ensure the emission ratings, a noise filter should be used on the output lines at the closest point. (3- to 50-W models: S82Y-JF3-N, 90-W and 100-W models: S82Y-JF6-N) 10. To ensure the Emission Enclosure rating, a ferrite ring core should be used on all cables (for S82K-P24024). 11. To meet Class 2 requirement with 100-W model, either a fuse or circuit breaker that is UL listed or CSA certified, and rated at 4.2 A max. should be used in the output of the power supply. Only then can the power supply output be considered as meeting Class 2.

61Switching Power Supply S82K /C0074PFC MODELS (S82K-P/C0106/C0106/C010624) Notes below this table apply to this page only. Item Single output Power Rating 90 W 100 W 240 W Efficiency (typical) 60% to 80% (Varies depending on specifications.) Input Voltage 120 V (85 to 132 VAC)/240 V (170 to 264 VAC) Selectable 100 to 230 V (85 to 253 VAC) Frequency 50/60 Hz (47 to 63 Hz) Current (S N t 1 ) 100-V input 2.5 A max. 4 A max. (See Note 1.) 200-V input 1.0 A max. 2 A max. Power factor 100-V input --- 0.95 min. 200-V input 0.7 min. 0.95 min. Leakage current (S N t 1 ) 100-V input 0.5 mA max.g (See Note 1.) 200-V input 1 mA max. Inrush current (S N t 1 ) 100-V input 25 A max. (See Note 1.) 200-V input 50 A max. Noise filter Yes Output (See Note 2.) Voltage adjustment range r10% (V.ADJ) Ripple (See Note 1.) 2% (p-p) max. Input variation influence 0.5% max. (at 85 to 132 VAC/170 to 264 VAC input, 100% load) 0.5% max. (at 85 to 253 VAC input, 100% load) Load variation influence 1.5% max. (0 to 100% load) 1.5% max. (10 to 100% load) Temperature variation 0.05%/qC max. Start up time 200 ms max. 1,000 ms max. Hold time (See Note 1.) 20 ms min. Additional function Overload protection 101% to 111% of rated load current, inverted L drop, automatic reset (See Note 3.) 105% to 160% of rated load current, inverted L drop, automatic reset Overvoltage protection No Under voltage alarm indicator Yes (color: red) No Under voltage alarm output Yes No Parallel operation Impossible Possible (2 units max.) (See Note 4.) (PFC specifications table continues on the next page.) Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC) 2. The output specification is defined at the power supply output terminals. 3. When the ambient temperature exceeds 25 qC, the protection function may operate at a current of 92% to 111% of the rated load current. 4. Parallel operation is set with the Parallel/Single Operation Selector Switch.

62 Switching Power Supply S82K

Specifications Table PFC Models (S82K-P/C0106/C0106/C010624) – continued from previous page Item Single output Power Rating 90 W 100 W 240 W Characteristics Ambient temperature Operating See the derating curve in the Engineering Data section (no condensation or icing)p Storage –25qC to 65qC (no condensation or icing) Ambient humidity Operating 25% to 85%y Storage 25% to 90% Dielectric strength 3,000 VAC at 50/60 Hz for 1 min. (between all inputs and outputs) 2,000 VAC at 50/60 Hz for 1 min. (between all inputs and GR terminal) 1,000 VAC at 50/60 Hz for 1 min. (between all outputs and GR terminal) Alarm current: 20 mA (90- and 100-W models) 25 mA (240-W models) Insulation resistance 100 M: min. at 500 VDC (between all outputs and all inputs/GR terminal) Vibration resistance Malfunction:10 to 55 Hz, 0.375-mm single amplitude for 2 hrs each in X, Y , and Z directions Malfunction:10 to 55 Hz, 0.15-mm single amplitude for 2 hrs each in X, Y , and Z directions Shock resistance Malfunction:150 m/s2, 3 times each in rX, rY, and rZ directions Malfunction:300 m/s2, 3 times each in rX, rY, and rZ directions Screw tightening torque 0.74 N /C0083 m max. (See Note 2.) Output indicator Yes (Green) Electromagnetic interference (See Note 1.) Conforms to FCC class A EMC (See Notes 3, 4.) 90-, 100-W Models (EMI): EN50081-1 Harmonic Current: EN61000-3-2 (200 VAC input only) Emission Enclosure: EN55022 class B Emission AC Mains: EN55022 class B Emission Output Ports: EN55022 class A (with a recommended optional filter) (See Note 3.) 240-W Model (EMI): EN50081-2 Harmonic Current: EN61000-3-2 Emission Enclosure: EN55011 class A (See Note 4.) Emission AC Mains: EN55011 class A Common to All Models (EMS): EN50082-2 Immunity ESD: EN61000-4-2: 4-kV contact discharge (level 2) 8-kV air discharge (level 3) Immunity Burst: EN61000-4-4: 2-kV power-line (level 3) 2-kV output line (level 4) Immunity Surge: EN61000-4-5: between 2-kV lines (except for 240-W models) between 4-kV line and FG (except for 240-W models) Approved standards UL508 (Listing)/1950 Class 2 (UL1310)/Class 2 (CSA C22.2 No. 950) (See Note 5.) CSA C22.2 No. 14/No. 950, EN50178 (VDE160), EN60950 Conforms to VDE0106/P100 UL508 (Listing)/1012 CSA C22.2 No. 14/E.B. 1402C, EN50178 (VDE160), EN60950, Conforms to VDE0106/P100 Weight 1,000 g max. 2,200 g max. (The notes below apply to this page only.) Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC) 2. Do not press down on the terminal block with a force exceeding 75 N while tightening the terminals. 3. To ensure the Emission Enclosure ratings, a noise filter should be used on the output lines at the closest point. (90- and 10 0-W models: S82Y-JF6-N) 4. To ensure the Emission Enclosure rating, a ferrite ring core should be used on all cables. 5. To meet Class-2 requirements with the 100-W model, either a fuse or circuit breaker that is UL listed or CSA certified, and r ated at 4.2 A max. should be used in the output of the power supply. Only then can the power supply output be considered as meet- ing Class 2.

63Switching Power Supply S82K /C0074REFERENCE VALUE Item Value Definition Reliability (MTBF) 135,000 hrs min. MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent a life of the product. Life expectancy 8 yrs. min. The life expectancy indicates average operating hours under the ambient temperature of 40qC and a load rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. Engineering Data /C0074DERATING CURVE Load (%) Ambient temperature (qC) Load (%) Ambient temperature (qC) Load (%) Ambient temperature (qC) Installation A Installation A Installation B S82K-03005 Installation A S82K-P10024: 85-VAC input 100-W Models with PFC S82K-P10024: 85-VAC input Installation B 65 65 Note: When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the load rate will become 90% or less. Parallel-Unit Operation 100-W Models without PFC Installation A Installation B Single-Unit Operation Parallel-Unit Operation 240-W Model Parallel-Unit Operation Note: 100-VAC input: 85 to 132 VAC Load (%) Ambient temperature (qC) S82K-P24024: 100-VAC input (See Note.) Load (%) Ambient temperature (qC) Single-Unit Operation S82K-P24024: 100-VAC input (See Note.) Installation A Installation A 90-W Models Load (%) Ambient temperature (qC) S82K-P09024: 85-VAC input Installation A Installation B 240-W Model Single-Unit Operation Note: 100-VAC input: 85 to 132 VAC

64 Switching Power Supply S82K

(A) Standard (Vertical) Installation (B) Horizontal Installation TopTop Note: Horizontal installation is not permitted for 240-W models. Mounting Position The derating curve can be ensured for these two kinds of installations. /C0074OVERLOAD PROTECTION The Power Supply is provided with an overload protection function that protects the load and the power supply from possible dam age by overcurrent. When the output current rises above a set value (refer to the table below), the protection function is triggered, decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared . Single output Dual outputs Single output 3 W 7.5 W 7.5 W 15 W 30 W 50 W 90 W 100 W 240 W Set value 105% to 160% of rated load current (See Note 1.) 105% to 250% of rated load current 105% to 160% of rated load current 101% to 111% of rated load current (See Notes 2 and 3.) 105% to 160% of rated load current (See Note 3.) Operation Inverted L drop type, automatic reset Inverted L drop/intermittent operation type, automatic reset Inverted L drop type, automatic reset Note: 1. When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the overload protection function will operate at currents from 95% to 160% of the rated load current. 2. When using the 90-W model at an ambient temperature exceeding 25 qC, the overload protection function will operate at currents from 92% to 111% of the rated load current. 3. When using the 100-W model with PFC in parallel operation, the overload protection function will operate at currents from 3.78 to 4.2 A. Output voltage (V) Output current (%) Intermittent operation Note: Do not short-circuit the output terminals of the S82K or use the S82K with excessive output current for a long time, other wise the internal circuitry of the S82K may be deteriorated or damaged. 500 100 Output voltage (V) Output current (%) Rated voltage 3-/7.5-/15-/90-/100-/240-W Models 30-/50-W Models Rated voltage When Using Dual Output (+/–) Models The +V output detects the total output power (+V output and -V output) to trigger the short-circuit protection against overcurr ent. This protection varies depending on the -V output state. The -V output independently triggers the short-circuit protection.

65Switching Power Supply S82K /C0074OVERVOLTAGE PROTECTION (S82K-24024T ONLY) The Power Supply is provided with an overvoltage protection function that protects the load and the Power Supply from possible damage by overvoltage. When the output voltage rises above a set value, the protection function is triggered, shutting off the output voltage. If this occurs, reset the Power Supply by turning it off for 1 minute min. and then turning it on again. Output voltage (V) Overvoltage protection operating 10% –10% Rated output voltage Variable range /C0074INRUSH CURRENT, STARTUP TIME, HOLD TIME Input ON AC input voltage AC input current Output voltage Inrush current on input application Startup time: 100 to 1000 ms max. depending on the model. Hold time (20 ms min.) 90% 96.5% Input OFF

66 Switching Power Supply S82K

/C0074UNDERVOLTAGE ALARM INDICATOR AND OUTPUT FUNCTION (ALL MODELS EXCEPT S82K-24024/P24024) If the output voltage at the output terminal drops to 75% to 90% of the rated voltage, the red indicator of the S82K (DC LOW indicator) will be lit. In the case of the 90-W, 100-W and S82K-24024T, a voltage drop alarm will be output via the relay available in the mode ls (DC LOW output). This function detects the voltage at the output terminal of the Power Supply. To check the precise output voltage, measure the voltage at the terminal of the load. Indicator Voltage Operation of 90-W, 100-W, S82K-24024T’s output (DC LOW output) (See Note 2.) Green: DC ON Red: DC LOW If the voltage at the output terminal is more than 82% of the rated voltage and operation is normal, the green indicator will be lit and the red indicator will not be lit. Green: DC ON Red: DC LOW (See Note 1.) If the voltage at the output terminal drops to below 82% of the rated voltage, the red indicator will be lit. (See Note 3.) Green: DC ON Red: DC LOW If the voltage at the output terminal is 0 V, both the green and red indicators will not be lit. Note: 1. The more the voltage at the output terminal drops, the darker both the green and red indicators will be. 2. The relay contacts have a capacity of 0.1 A at 24 VDC. 3. The red indicator will actually first light at a voltage between 75% and 90% of the rated voltage. /C0074BLOCK DIAGRAMS S82K-003/C0106/C0106 (3 W) S82K-007/C0106/C0106 (7.5 W, Single Output) Fuse (1 A) Noise filter Inrush current protection circuit Rectifier Drive control circuit Photocoupler AC (L) AC (N) Rectifier – V + V Undervoltage alarm indicator Overload alarm circuit Detector S82K-007/C0106/C0106 (7.5 W, Dual Outputs) Fuse (1 A) Noise filter Inrush current protection circuit Rectifier Drive control circuit Photocoupler AC (L) AC (N) Rectifier – V + V Rectifier Undervoltage alarm indicator 3-terminal REG Overload alarm circuit Detector

67Switching Power Supply S82K Fuse (3 A) Noise filter Inrush current protection circuit Rectifier Drive control circuit Photocoupler AC (L) AC (N) Rectifier – V + V Undervoltage alarm indicator Overload alarm circuit Detector S82K-015/C0106/C0106 (15 W) S82K-030/C0106/C0106 (30 W) S82K-05024 (50 W) S82K-09024 (90 W) S82K-10024 (100 W) Fuse (5 A) Noise filter Inrush current protection circuit Rectifier Drive control circuit Photocoupler AC (L) AC (N) Rectifier – V + V Overload alarm circuit Detector 100 or 200 V Selectable terminals (See Note.) Note: Use the short bar to short-circuit terminals 7 and 8 to select 100 to 120 VAC and remove the short bar to select 200 to 240 VAC. DC LOW Undervoltage alarm indicator/output S82K-P09024 (90 W) S82K-P10024 (100 W) Fuse (5 A) Noise filter Rectifier Drive control circuit Photocoupler AC (L) AC (N) Rectifier – V + V Undervoltage alarm indicator Overload alarm circuit Detector 100 or 200 V Selectable terminals (See Note.) Note: Use the short bar to short-circuit terminals 7 and 8 to select 100 to 120 VAC and remove the short bar to select 200 to 240 VAC. Inrush current protection circuit Harmonic current emission control (200-V input only)

68 Switching Power Supply S82K

S82K-24024/C0106 (240 W) – V + V Fuse (5 A) Noise filter Inrush current protection circuit Drive control circuit DC OUTPUT Overvoltage protection circuitry (See Note 1.) Photocoupler INPUT AC (L) AC (N) Overload alarm circuit Rectifying and smoothing circuit Overvoltage alarm circuit DetectorGR Rectifier DC LOW Undervoltage alarm indicator/output (See Note 1.)Note: 1. The overvoltage protection circuitry and undervoltage alarm indicator/output are available in the S82K-24024T only. 2. Use the short bar to short-circuit terminals 7 and 8 to select 100 to 120 VAC and remove the short bar to select 200 to 230 VAC. 100 or 200 V Selectable terminals (See Note 2.) S82K-P24024 (240 W) – V + V Fuse (8 A) Noise filter Inrush current protection circuit Drive control circuit DC OUTPUT INPUT AC (L) AC (N) Overload alarm circuit Rectifying and smoothing circuit Detector GR Rectifier Harmonic current emission control Smoothing Photocoupler

69Switching Power Supply S82K Dimensions Unit: mm (inch) 37.5 /C0074S82K-003/C0106/C0106(3 W) S82K-007/C0106/C0106(7.5 W) M3.5 with square washer Mounting Holes Attached Mounting Bracket M4 or 4.5-dia. hole Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. Mounting Brackets (Supplied with the Power Supply) Two, 4.5 dia. 35 25 Used when not mounting the Power Supply directly on the DIN rail. L (See Note.) 4.6 (sliding 7 max.) (2.95) 37.5 (1.48) 9.8 8.3 65 (2.56) 3545 58.1 /C0074S82K-015/C0106/C0106 (15 W) Mounting Holes Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. Two, M4 or 4.5-dia. mounting holes (2.36) L (See Note.) (2.95) 58.1 4.6 (sliding 7 max.) M3.5 with square washer (1.77) 9.8 8.3 91 (3.58) 5 7.5

70 Switching Power Supply S82K

/C0074S82K-030/C0106/C0106(30 W) S82K-05024 (50 W) (sliding 7 max.) M3.5 with square washer Four, M4 or 4.5-dia. mounting holes (2.36) 80 (3.15) L (See Note.) Four, 4.5 dia. Mounting Holes Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. 91 (3.58) 90 (3.54) 58.1 (2.95) 60 45 35.2 7.5

71Switching Power Supply S82K Unit: mm (inch) /C0074S82K-/C010609024 (90 W) S82K-/C010610024 (100 W) (2.36) 135 (5.31)L (See Note.) Four, M4 or 4.5-dia. mounting holes 58.175 (2.95) (sliding 7 max.) M3.5 with square washer Short bar M3.5 terminal screw 145 (5.71) 135 Four, 4.5 dia. 91 (3.58) 35.2 7.5 Mounting Holes Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. 8.39.8

72 Switching Power Supply S82K

112.8 (4.44) /C0074S82K-/C010624024/C0106(240 W) M3.5 with square washer Short barM3.5 terminal screwMounting Holes Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. Four, M4 or 4.5-dia. mounting holes 130 (5.12) Four, 4.5 dia. 100 (3.94) 115 (4.53)4 (sliding 8 max.) 9.8 8.3 7.8 27.5 270 (10.63) 115 (4.53) 4.2138 (5.43) 280 (11.02) 270 L (See Note.)

73Switching Power Supply S82K Unit: mm (inch) /C0074ACCESSORIES Noise Filter (Order Separately) 16 max. A B Two, 4.8 dia. (Mounting holes) D 6.5 Six, M46.5C 16 max. Nameplate 47 S82Y-JF3-N for 3- to 50-W models S82Y-JF6-N for 90- and 100-W Models Model A B C D DIN Rail Mounting Track (Order Separately) 4.5 15 25 25 25 25 10 10 1,000 (500) (See Note.) 7.3 35 27 4.5 15 25 25 25 25 15 10 10 1,000 35 27 24 29.2 1 1.5 PFP-100N2 15 (5) (See Note.) Note: The values shown in parentheses are for the PFP-50N. 12, 25 x 4.5 oblong PFP-100N/PFP-50N

74 Switching Power Supply S82K

/C0074S82K-015/C0106/C0106 /C0074S82K-030/C0106/C0106/ S82K-05024 /C0074S82K-/C010609024/ S82K-/C010610024 /C0074S82K-003/C0106/C0106/ S82K-007/C0106/C0106 (Single Output) /C0074S82K-007/C0106/C0106 (Dual outputs) 23 4 Bottom view (Only for S82K-P10024)

75Switching Power Supply S82K 1. DC Output Terminals: Connect the load lines to these terminals. 2. Input Terminals: Connect the input lines to these terminals. 3. Ground Terminal (GR): Connect a ground line to this terminal. 4. Input Voltage Selector Terminals: Selects a 100-V or 200-V input voltage. 5. Output Indicator (DC ON): Lights while a Direct Current (DC) output is ON. 6. Output Voltage Adjuster(V.ADJ): It is possible to increase or decrease the output voltage. 7. Undervoltage Alarm Indicator (DC LOW): Other than S82K-24024 and S82K-P24024 models. 8. Undervoltage Alarm Output (DC LOW): S82K-/C010609024/-/C010610024/-24024T models only. 9. Parallel/Single Operation Selector: Set to “PARALLEL” or “P” for parallel operation. /C0074S82K-/C010624024/C0106 23 4 Bottom view 675 1

76 Switching Power Supply S82K

Be sure to connect the grounding line. Not doing so may result in electric shock. Do not attempt to disassemble the Power Supply or touch its internal parts while power is being supplied. Doing so may result in electric shock. Do not touch the terminals of the Power Supply within one minute after power has been turned OFF. Doing so may result in electric shock due to a residual voltage. Do not touch the Power Supply Unit while power is being supplied or immediately after power has been turned OFF. Doing so may result in a skin burn due to high temperature of the Power Supply. WARNING /C0074MOUNTING To improve and maintain the reliability of the Power Supply over a long period of time, consider the heat dissipation. The Power Supply is designed to dissipate heat by means of natural air-flow. Mount the Power Supply so that air flow takes place around the Power Supply. Air When mounting two or more Power Supplies side-by-side, allow at least 20 mm (0.79 in) spacing between them, as shown in the following illustration. Forced-air cooling is recommended. 20 mm min. To mount the Power Supply on a DIN rail, hook portion (A) of the Power Supply to the rail and press the Power Supply toward direction (B). (A) (B) /C0074REMOVAL To remove the Power Supply, pull down portion (C) with a flat-blade screwdriver and pull out the Power Supply. (C) 30 mm min. Track stopper When tightening the terminals, do not tighten the terminal block to a torque greater than 75 N. /C0074SELECTION OF 100 TO 120 VAC OR 200 TO 240 VAC INPUT VOLTAGE (S82K-/C010609024/-/C010610024/-24024/-24024T) Select a 120 V or 240 V input by shorting or opening the Input Voltage Selector Terminals, as shown in the following diagram. The default setting is 240 V. 100-V to 120-V Input 200-V to 240-V Input Note: Use the short bar to short-circuit terminals 7 and 8. Note: Remove the short bar. 867 867

77Switching Power Supply S82K INPUT INPUT /C0074GENERATING OUTPUT VOLTAGE (r) An output of r can be generated by using two Power Supplies (as shown below) because the Power Supply produces a floating output. When connecting the Power Supplies in series with an operation amplifier, connect diodes to the output terminals as shown by the dotted lines in the figure. No diodes are required with S82K 90-/100-/240-W models. /C0074WIRING To prevent incorrect wiring of the input/output terminals, pay attention to their polarities. /C0074BATTERY CHARGING With S82K-/C010609024/-/C010610024/-24024T models, a reduction in lifetime due to over discharge of the battery can be prevented using the DC LOW output. (Discharge can be interrupted at 0.75 to 0.9 u 24 V.) /C0074SERIES OPERATION S82K 90-W/100-W/240-W models can be operated in series. It must be noted that the + output of the 7.5-W dual output model cannot be connected in series to its – output. 90-W/100-W/240-W Models INPUT INPUT INPUT INPUT /C0074PARALLEL OPERATION S82K 100-W/240-W models can be operated in parallel. Perform parallel operation with power supplies satisfying the same specifications. INPUT INPUT 100-W and 240-W Models Load Note: When operating the S82K-P10024 or 240-W model in parallel operation, set the switch to “PARALLEL.” Refer to the derating curve for the rated current under this operation. INPUT INPUT Load 3-, 7.5-, 15-, 30-, 50- and 90-W Models /C0074PARALLEL OPERATION PRECAUTIONS x The length and thickness of each wire connected to the load must be the same so there is no difference in voltage drop value between the load and the output terminals of each Power Supply. x Adjust the output voltage of each Power Supply so there will be no difference in output voltage between each Power Supply. x If the S82K-P10024 or 240-W Power Supply is used in single operation under the parallel operation setting, the overcurrent protection will be actuated at an output of 90% to 95% (in current) and will not allow a 100% output. x If the S82K-P10024 or 240-W Power Supplies are used in parallel operation under the single operation setting, one of them will operate at 110% output, causing severe heat der- ating and shortening the service life.

78 Switching Power Supply S82K

The minimum output current of the S82K-00727 and S82K-00728 is restricted by the output voltage and control method. Note: All the outputs of the S82K-00727 and S82K-00728 are controlled by the +V output. If the +V output cur- rent falls to 10% or less of the rated output, the –V output voltage may drop. Operating and Storage Environments To avoid deterioration of the operating characteristics or malfunction, do NOT use or store the Unit in locations subject to the following conditions: x Direct sunlight. x Ambient operating temperatures outside the range indi- cated by the derating curve. x Ambient operating humidity outside the range of 25% to 85%. x Condensation as the result of severe changes in temperature. x Ambient storage temperatures outside the range of –25qC to 65qC. x Corrosive or flammable gases. x Dust (especially iron dust) or salts. x Shock or vibration. x Exposure to water, oil, or chemicals.

79Switching Power Supply S82K /g50/g48/g53/g50/g49/g3/g50/g49/g16/g47/g44/g49/g40 /g42/g79/g82/g69/g68/g79/g3/g16/g3/g75/g87/g87/g83/g29/g18/g18/g90/g90/g90/g17/g82/g80/g85/g82/g81/g17/g70/g82/g80 /g56/g54/g36/g3/g16/g3/g75/g87/g87/g83/g29/g18/g18/g90/g90/g90/g17/g82/g80/g85/g82/g81/g17/g70/g82/g80/g18/g82/g72/g76 /g38/g68/g81/g68/g71/g68/g3/g16/g3/g75/g87/g87/g83/g29/g18/g18/g90/g90/g90/g17/g82/g80/g85/g82/g81/g17/g70/g68 /g36/g47/g47/g3/g39/g44/g48/g40/g49/g54/g44/g50/g49/g54/g3/g54/g43/g50/g58/g49/g3/g36/g53/g40/g3/g44/g49/g3/g48/g44/g47/g47/g44/g48/g40/g55/g40/g53/g54/g17/g3/g55/g82/g3/g70/g82/g81/g89/g72/g85/g87/g3/g80/g76/g79/g79/g76/g80/g72/g87/g72/g85/g86/g3/g76/g81/g87/g82/g3/g76/g81/g70/g75/g72/g86/g15/g3/g71/g76/g89/g76/g71/g72/g3/g69/g92/g3/g21/g24/g17/g23 Cat No. GC PS6 2/03 Specifications subject to change without notice Printed in USA /g50/g48/g53/g50/g49/g3/g38/g36/g49/g36/g39/g36/g15/g3/g44/g49/g38/g17 /g27/g27/g24/g3/g48/g76/g79/g81/g72/g85/g3/g36/g89/g72/g81/g88/g72 /g55/g82/g85/g82/g81/g87/g82/g15/g3/g50/g81/g87/g68/g85/g76/g82/g3/g48/g20/g37/g3/g24/g57/g27 /g23/g20/g25/g16/g21/g27/g25/g16/g25/g23/g25/g24 /g50/g48/g53/g50/g49/g3/g40/g47/g40/g38/g55/g53/g50/g49/g44/g38/g54/g3/g47/g47/g38 /g50/g81/g72/g3/g38/g82/g80/g80/g72/g85/g70/g72/g3/g39/g85/g76/g89/g72 /g54/g70/g75/g68/g88/g80/g69/g88/g85/g74/g15/g3/g44/g47/g3/g25/g19/g20/g26/g22 /g27/g23/g26/g16/g27/g23/g22/g16/g26/g28/g19/g19 /g41/g82/g85/g3/g56/g54/g3/g87/g72/g70/g75/g81/g76/g70/g68/g79/g3/g86/g88/g83/g83/g82/g85/g87/g3/g82/g85/g3/g82/g87/g75/g72/g85/g3/g76/g81/g84/g88/g76/g85/g76/g72/g86/g29 /g27/g19/g19/g16/g24/g24/g25/g16/g25/g26/g25/g25