S80 ASHCROFT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

Thermocouple Temperature probes with mineral insulation, available with optional connectors. Data Sheet SPECIFICATIONS Insert Stem Diameter: 1∕8, 3∕16, 1∕4, 3 mm, 4.5 mm, 6 mm, 8 mm Stem Length: Minimum: 50 mm/2 in Maximum: 3 m/120 in Sensor Type & Range Thermocouples Type J -40 to 750 °C Type E -200 to 800 °C Type K -200 to 1000 °C Type N -200 to 1000 °C Type T -250 to 350 °C Wiring Configuration: Thermocouples Single or Dual KEY BENEFITS

  • Flexible designs for critical applications
  • Fast response times

DESCRIPTION

These probes are supplied as either single or dual sensors. The sensor(s) is (are) housed inside a flexible metal sheath. With or without extension lead wire, process connection on request. If fitted, the extension lead wire (with or without protective spring and/or electromagnetic shielding) can be provided with PVC, silicone, PTFE or fiberglass insulation. The soldering between the extension lead wire and the sheathed cable is enclosed in a sealed transition. TYPICAL USES Industrial probes for chemical, petrochemical and power plants For a wide range of process applications—vapors, gases, liquids and non-abrasive substances—provided that these are compatible with the sheath material Flexible configurations, heavy duty MgO Special designs for intrinsically safe and non-incendive applications Available with remote heads and flex armor (1) Absolute temperature in °C S80 Thermocouple Options Probe with extension lead wire Connector Compression Fitting Protection Spring on lead wire Round Pin OPTIONAL APPROVALS FM Intrinsically safe: Class I, Division 1, Groups A, B, C, D T4 for -55 °C ≤ Ta ≤ 80 °C T5 for -55 °C ≤ Ta ≤ 55 °C T6 for -55 °C ≤ Ta ≤ 40 °C FM Nonincedive: Class I, Division 2, Groups A, B, C, D T4 for -55 °C ≤ Ta ≤ 80 °C T5 for -55 °C ≤ Ta ≤ 55 °C T6 for -55 °C ≤ Ta ≤ 40 °C ATEX or IECEx: ATEX or IECEx II 1 G Ex ia IIC T6 Ga -50 °C to 60 °C II 2 G Ex ib IIC T6 Gb -50 °C to 60 °C II 2 G Ex e IIC T6 Gb -55 °C to 60 °C Thermocouples (IEC 60584-2) Type J Type K Type E Type N Type T Class 1 ±1.5 °C or ±0.0040*|t|(1) ±1.5 °C or ±0.0040*|t|(1) ±1.5 °C or ±0.0040*|t|(1) ±1.5 °C or ±0.0040*|t|(1) ±0.5 °C or ±0.0040*|t|(1) Class 2 ±2.5 °C or ±0.0075*|t|(1) ±2.5 °C or ±0.0075*|t|(1) ±2.5 °C or ±0.0075*|t|(1) ±2.5 °C or ±0.0040*|t|(1) ±1.0 °C or ±0.0075*|t|(1) Class 3 N/A ±2.5 °C or ±0.0040*|t|(1) ±2.5 °C or ±0.0150*|t|(1) ±2.5 °C or ±0.0150*|t|(1) ±1.0 °C or ±0.0150*|t|(1) Thermocouples (ANSI MC 96.1) Type J Type K Type E Type N Type T Standard ±2.2 °C or ±0.0075*|t|(1) ±2.2 °C or ±0.0075*|t|(1) ±1.7 °C or ±0.0050*|t|(1) ±2.2 °C or ±0.0040*|t|(1) ±1.0 °C or ±0.0075*|t|(1) Special ±1.1 °C or ±0.0040*|t|(1) ±1.1 °C or ±0.0040*|t|(1) ±1.0 °C or ±0.0075*|t|(1) ±1.1 °C or ±0.0040*|t|(1) ±0.5 °C or ±0.0040*|t|(1) S80 Thermocouple Temperature Probes of 5 All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Inconel®. For more information, see Ashcroft Brands & Trademarks

Thermocouple Temperature probes with mineral insulation, available with optional connectors. Data Sheet OPTIONAL APPROVALS FM Intrinsically Safe: Class I, Division 1, Groups A, B, C, D T4 for -55 °C ≤ Ta ≤ 80 °C T5 for -55 °C ≤ Ta ≤ 55 °C T6 for -55 °C ≤ Ta ≤ 40 °C FM Non-Incendive: Class I, Division 2, Groups A, B, C, D T4 for -55 °C ≤ Ta ≤ 80 °C T5 for -55 °C ≤ Ta ≤ 55 °C T6 for -55 °C ≤ Ta ≤ 40 °C ATEX or IECEx: ATEX or IECEx II 1 G Ex ia IIC T6 Ga -50 °C to 60 °C II 2 G Ex ib IIC T6 Gb -50 °C to 60 °C II 2 G Ex e IIC T6 Gb -55 °C to 60 °C II 2 G Ex d IIC T6 Gb -55 °C to 60 °C BUZH-AL Type E BUZH-AL Type D DIN B Type B SCCA-AL Type N SCCI-Stainless Steel Type G PR 7501 with display Type P E&H Display Housing Type H Polypropylene Type A Cast Iron Type Y OPTIONAL S80 HEADS S80 Thermocouple Temperature Probes of 5 All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Inconel®. For more information, see Ashcroft Brands & Trademarks

Thermocouple Temperature probes with mineral insulation, available with optional connectors. Data Sheet ORDERING CODE Example: S80 S R K N 2 1 3 7 2 Area Classification S - Standard S J - Intrinsic Safety - ia B - Intrinsic Safety - ib E - Increased Safety N - Non-Incendive Sheath Diameter R - 1⁄8˝ Ø3.18 mm R S - 3⁄16˝ Ø4.76 mm T - ¼˝ Ø6.35 mm 3 - 3 mm 4 - 4.5 mm 6 - 6 mm 8 - 8 mm Thermocouple Type E - E -Temperature range: -200 to 800 °C J - J -Temperature range: -40 to 750 °C K - K -Temperature range: -200 to 1000 °C K N - N -Temperature range: -200 to 1000 °C T - T -Temperature range: -250 to 350 °C Accuracy or Class N - ANSI MC 96.1: Standard N S - ANSI MC 96.1: Special 1 - IEC 60584-2: Class 1 2 - IEC 60584-2: Class 2 3 - EC 60584-2: Class 3 Junction 1 - Ungrounded 2 - Grounded 2 3 - Ungrounded, vibration-proof 4 - Ungrounded, vibration-proof Electrical Circuit 1 - Single 1 2 - Dual Sheath Material 1 - AISI 316 / 1.4401 3 - Inconel® 600 / 2.4816 3 Wire Termination A - Standard plain stripped leads (1½˝) B - Spade lugs #8 C - ¼˝ Push on connector D - With miniature female connector E - With miniature female and additional male connector F - With standard female connector G - With standard female and additional male connector 7 - Stripped 7 3 - With miniature male connector 4 - With miniature male and female connector 5 - With standard male connector 6 - With standard male and female connector Connector Strain Relief - - Non-applicable (no connector) 1 - Crimp - Braze adapter (for use with Flex Armor and no wire options) 2 - Grommet - for regular wire option, with no flex armor 2 3 - Bracket - for regular wire option, with no flex armor Cont. on next page S80 Thermocouple Temperature Probes of 5 All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Inconel®. For more information, see Ashcroft Brands & Trademarks

Thermocouple Temperature probes with mineral insulation, available with optional connectors. Data Sheet ORDERING CODE Example: (Continued ) B X X - M M C3 3 - 3P T LC=900 L=400 Remote Head Type - - Non-applicable (no remote head) G - SCCI Stainless steel N - SCCA Aluminum B - DIN B AluminumIN B Aluminum B D - BUZ Aluminum E - BUZH Aluminum P - PR 7501 (N/A with FM approval) Y - Cast iron (N/A with FM approval) A - Polypropylene (N/A with FM approval) H - E&H Housing (N/A with FM approval) Length Probe X - L=(min=50, max=10000) (add actual length in mm L=?? at the end of ordering code) X Length Cable X - Lc=(min=100, max=10000) (add actual length in mm LC=?? at the end of ordering code) X Flex Armor - - Without - 1 - With flex armor 2 - Flex armor with PVC jacket Lead Wire M - PVC M N - Silicon O - PTFE P - Fiberglass - - Without Lead Wire Options M - With protective spring on lead wire M N - Without protective spring on lead wire O - Electrically shielded, with protective spring P - Electrically shielded, without protective spring Q - With stainless steel braided cover, with protective spring R - With stainless steel braided cover, without protective spring - - Without Process Connection -- - Without connection C1 - Compression fitting ¼ NPT, AISI 316 C2 - Adjustable compression fitting with gland TFE ¼˝ AISI 316 C3 - Compression fitting ½ NPT, AISI 316 C3 C4 - Adjustable compression fitting with gland TFE ½˝ AISI 316 B1 - Non-adjustable compression fitting ¼ NPT, brass B2 - Adjustable compression fitting with gland TFE ¼˝ brass B3 - Non-adjustable compression fitting ½ NPT, brass B4 - Adjustable compression fitting with gland TFE ½˝ brass A1 - Compression fitting G ¼˝ AISI 316 A3 - Compression fitting G ½˝ AISI 316 Y1 - Adjustable spring loaded, double thread ½ NPT, AISI 316 3 3 Certifications - - None required - F - FM A - ATEX X - IECEx S - SIL 2 + ATEX I - INMETRO D - ATEX + IECEX 2 - SIL 2 P - EAC (Gost R) + Metrological Russia Calibration Report - - Without 3P - 3 points single 3P 5P - 5 points single 3D - 3 points dual 5D - 5 points dual Tagging - - Without T - Label in stainless steel with tag T S80 Thermocouple Temperature Probes of 5 All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Inconel®. For more information, see Ashcroft Brands & Trademarks Insertion length in mm Lead wire length in mm mm = inches x 25.4

Thermocouple Temperature probes with mineral insulation, available with optional connectors. Data Sheet DIMENSIONS in [ ] are millimeters For reference only, consult Ashcroft for specific dimensional drawings L 30 mm d HOW TO ORDER S80 TEMPERATURE PROBES: The ordering code is built by selecting the appropriate configuration for the various sections of the ordering code. The insert nominal length L is measured from top of the cable transition piece or center of threads to the tip of the probe. The lead wire length LC is measured for the base of the lead wire transition piece to the end of the lead wire jacket. The L length and the LC length are added to the end of the ordering code in millimeters. To convert inches to millimeters multiply by 25.4. mm = inches x 25.4 Custom configurations are available. d = Stem diameter LC = Length lead wire L = Insertion length S80 Thermocouple Temperature Probes of 5 All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Inconel®. For more information, see Ashcroft Brands & Trademarks * 50 mm with FM approval