S78DL33L_07 AUK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Features

  • Low Standby Current Consumption (500 ㎂ Typ.)
  • Maximum Output Current (180 ㎃ Max.)
  • Less I/O voltage Difference (250 ㎷ Max.)

Ordering Information

Type NO. Marking Package Code S78DL33L S78DL33L TO-92L O u t l i n e D i m e n s i o n s u n i t : mm SSeemmiiccoonndduuccttoorr PIN Connections 1. Output 2. GND 3. Input ■Functional Block Diagram

M a x i m u m r a t i n g s Ta=25°C Characteristic Symbol Ratings Unit Operating Input voltage V IN 16 V Power Dissipation P D 1 W Operating Temperature Range T OPR -40~+85 °C Junction Temperature T j 150 °C Storage Temperature Range T stg -55~150 °C Lead Temperature Time Tsol 260 (10 Sec) °C E l e c t r i c a l C h a r a c t e r i s t i c s (※ V IN=4.3V , IOUT=100uA, T j =25°C) Characteristic Symbol Test Condition Min. Typ. Max. Unit Output voltage V OUT V IN=4.3V, IOUT=100uA 3.168 3.3 3.432 V Voltage Regulation Δ VOUT(1) VIN=4.3V~10V, IOUT=100uA - 2 15 mV Load Regulation Δ VOUT(2) VIN=4.3V , IOUT=1~100mA - 7 28 mV IOUT=50mA - 110 230 Dropout Voltage V DROP IOUT=100mA - 150 300 mV Ripple Rejection Ratio RR f=100Hz, I OUT=100uA - 75 - dB VIN=4.3V , IOUT=100uA 200 400 uA VIN=4.3V , IOUT=50mA 0.9 1.8 mA Ground pin Current I GND VIN=4.3V , IOUT=100mA 2.1 4 mA ■Test circuit

Electrical Characteristic Curves Fi g. 2 |Vout - Vin| -I OUT Fig. 1. Vin - Vout Fig. 4. Input voltage – Ground pin Current Fig. 3. Pd - Ta

The AUK Corp. products are intended for the use as components in general electronic equipment (Office and co mmunication equipment, m easuring equipment, home appliance, etc.). Please make sure that you consult with us before you use these AUK Corp. products in equipments which require high quality and / or reliability, and in equipments which could have major impact to th e welfare of human life(atomi c energy control, airplane, spaceship, transportation, co mbustion control, all types of safety device, etc.). AUK Corp. cannot accept liability to any damage which may occur in case these AUK Corp. products were used in the mentioned equi pments without prior consultation with AUK Corp.. Specifications mentioned in this publication are subject to change without notice.