S78DL15 KODENSHI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Features

  • Low Quiescent Current Consumption (250uA Typ.)
  • Maximum Output Current (150mA Max.)
  • Less Input/Output V oltage Difference (600mV Max @IO=100mA.)

Ordering Information

T y p e N O . M a r k i n g P a c k a g e C o d e S 7 8 D L 1 5 S 7 8 D L 1 5 T O - 9 2 O u t l i n e D i m e n s i o n s u n i t : mm SSeemmiiccoonndduuccttoorr ■Block Diagram 4.40~ 4.80 1 2 3 4.40~ 4.80 0.50 Max. 13.50~ 14.50 3.40~ 3.60 0.45 Max. 1.27 Typ. 1.27 Typ. ■ Pin Connection 1. Output 2. Ground 3. Input

M a x i m u m r a t i n g s Ta=25 Characteristic Symbol Ratings Unit Operating Input V oltage V IN 16 V Power Dissipation PD 625 mW Junction Temperature T j 150 °C Operating Temperature Range T OPR -40~+85 °C Storage Temperature Range T stg -55~150 °C

Electrical Characteristics

(Electric Characteristic at VIN=VO+1.0V , IOUT=100uA, Tj =25°C, unless otherwise specified) Characteristic Symbol Test Condition Min. Typ. Max. Unit Output V oltage V O V IN=2.5V , IOUT=100uA 1.44 1.50 1.56 V Line Regulation ΔVO(Δ VI) VIN=2.5V~10V , IOUT=100uA - 1 5 mV Load Regulation ΔVO(Δ IO) VIN=2.5V , IOUT=1~150mA - 15 28 mV IOUT=50mA - 450 500 Dropout V oltage V DROP IOUT=100mA - 500 600 mV Ripple Rejection Ratio RR f=120Hz, I OUT=100uA - 75 - dB VIN=2.5V , IOUT=100uA - 250 400 uA VIN=2.5V , IOUT=50mA - 1.5 3.0 mA Quiescent Current I QC VIN=2.5V , IOUT=100mA - 3.5 5.0 mA ■Test circuit

Electrical Characteristics Curves Dropout V oltage VDROP [V] Output Current IO [mA] 50 25 750 150125100 1.0 0.6 0.8 0.4 0.2 VI=2.5V Fig.1 IO vs. VDROP Fig.2 VI vs. IQC Input V oltage VI [V] 8 4 106 12 Quiescent Current IQC [mA] IO=0mA IO=50mA IO=100mA Fig.3 PD vs Ta Ambient Temperature Ta [˚C] 100 50 1000 600 75 150 800 200 400 Power dissipation PD [mW] 125 100 Relative Output V oltage [%] 200 150 250 100 400350300 Output Current IO [mA] Fig.4 IO vs. VO

The AUK Corp. products are intended for the use as components in general electronic equipment (Office and co mmunication equipment, m easuring equipment, home appliance, etc.). Please make sure that you consult with us before you use these AUK Corp. products in equipments which require high quality and / or reliability, and in equipments which could have major impact to the welfare of human life(atomic energy control, airplane, spaceship, transportation, combustion control, all types of safety device, etc.). AUK Corp. cannot accept liability to any damage which may occur in case these AUK Corp. products were used in the mentioned equipments without prior consultation with AUK Corp.. Specifications mentioned in this publication are subject to change without notice.