DESCRIPTION
Ashcroft® S50 temperature sensor assemblies provide accurate temperature measurements. Each temperature sensor assembly consists of a spring-loaded temperature sensor, magnesium oxide (MgO), insulated insert, connection head and lag extension. The assembly may also include an optional terminal block and/or transmitters. Thermocouple assemblies are manufactured to IEC 60584-2 or ANSI MC 96.1 and RTDs assemblies are manufactured to IEC 60751. TYPICAL USES Industrial process, petrochemical, oil and gas applications Process temperature measurements for oil, gas and power generation systems Process control, monitoring asset protection General purpose or hazardous area Available with DIN mounting plate or spring loaded fitting designs SPECIFICATIONS Ashcroft Series: S50 Sheath Diameter: 1⁄8˝, 3⁄16˝, ¼˝, 3 mm, 4.5 mm, 6 mm, 8 mm Stem Length: Minimum: 50 mm/2 in Maximum: 3 m/120 in Sensor Type & Measuring Range RTDs Platinum 385 Pt 100 -200 to 600 °C Pt 1000 -40 to 600 °C Thermocouples Type J -40 to 750 °C Type E -200 to 800 °C Type K -200 to 1000 °C Type N -200 to 1000 °C Type T -250 to 350 °C Wiring Configuration: RTDs - single or dual
2 Wire
3 Wire
4 Wire
Thermocouples - single or dual Accuracy Class RTDs - (IEC 60751) KEY BENEFITS
- Industrial process applications.
- Designs for hazardous locations. Thermocouples (IEC 60584-2) Type J Type K Type E Type N Type T Class 1 ±1.5 °C or ±0.0040*|t|(1) ±1.5 °C or ±0.0040*|t|(1) ±1.5 °C or ±0.0040*|t|(1) ±1.5 °C or ±0.0040*|t|(1) ±0.5 °C or ±0.0040*|t|(1) Class 2 ±2.5 °C or ±0.0075*|t|(1) ±2.5 °C or ±0.0075*|t|(1) ±2.5 °C or ±0.0075*|t|(1) ±2.5 °C or ±0.0040*|t|(1) ±1.0 °C or ±0.0075*|t|(1) Class 3 N/A ±2.5 °C or ±0.0040*|t|(1) ±2.5 °C or ±0.0150*|t|(1) ±2.5 °C or ±0.0150*|t|(1) ±1.0 °C or ±0.0150*|t|(1) (1) Absolute temperature in °C Thermocouples (ANSI MC 96.1) Type J Type K Type E Type N Type T Standard ±2.2 °C or ±0.0075*|t|(1) ±2.2 °C or ±0.0075*|t|(1) ±1.7 °C or ±0.0050*|t|(1) ±2.2 °C or ±0.0040*|t|(1) ±1.0 °C or ±0.0075*|t|(1) Special ±1.1 °C or ±0.0040*|t|(1) ±1.1 °C or ±0.0040*|t|(1) ±1.0 °C or ±0.0075*|t|(1) ±1.1 °C or ±0.0040*|t|(1) ±0.5 °C or ±0.0040*|t|(1) SSCA Head of 7 Data Sheet S50 Industrial RTDs & Thermocouples with NPT Connections Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Inconel®. For more information, see Ashcroft Brands & Trademarks
FM Explosion Proof: Class I, Division 1, Groups A, B, C, D T4 for -40 °C ≤ Ta ≤ 80 °C T6 for -40 °C ≤ Ta ≤ 60 °C FM Intrinsically Safe: Class I, Division 1, Groups A, B, C, D T4 for -55 °C ≤ Ta ≤ 80 °C T5 for -55 °C ≤ Ta ≤ 55 °C T6 for -55 °C ≤ Ta ≤ 40 °C FM Non-Incendive: Class I, Division 2, Groups A, B, C, D T4 for -55 °C ≤ Ta ≤ 80 °C T5 for -55 °C ≤ Ta ≤ 55 °C T6 for -55 °C ≤ Ta ≤ 40 °C ATEX or IECEx: ATEX or IECEx II 1 G Ex ia IIC T6 Ga -50 °C to 60 °C II 2 G Ex ib IIC T6 Gb -50 °C to 60 °C II 2 G Ex e IIC T6 Gb -55 °C to 60 °C II 2 G Ex d IIC T6 Gb -55 °C to 60 °C BUZH-AL Type E BUZH-AL Type D DIN B Type B SCCA-AL Type N SCCI-Stainless Steel Type G Type F Ex d-AL Type S Ex d-Stainless Steel PR 7501 with display Type P E&H Display Housing Type H Polypropylene Type A Cast Iron Type Y OPTIONAL S50 HEADS of 7 Data Sheet S50 Industrial RTDs & Thermocouples with NPT Connections Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Inconel®. For more information, see Ashcroft Brands & Trademarks
next pageS50 RTD ORDERING CODE Example: S50 1 T 1 A A B A D 2 Area Classification 1 - Standard - General purpose 1 2 - Explosion proof (must order head type F or S) 3 - Intrinsic Safety - ia B - Intrinsic Safety - ib E - Increased Safety N - Non-Incendive Sheath Diameter R - 1∕8˝ Ø3.18 mm S - 3∕16˝ Ø4.76 mm T - 1/4˝ Ø6.35 mm T 3 - 3 mm 4 - 4.5 mm 6 - 6 mm 8 - 8 mm RTD Type 1 - Pt 100 Platinum 385 temperature coefficient 1 3 - Pt 1000 Platinum 385 temperature coefficient Accuracy or Class (IEC 60751) A - Class A A B - Class B C - 1/2 DIN D - Class AA - 1/3 DIN RTD Element/Range A - -50 to 400 °C A B - -200 to 600 °C D - Vibration-proof Electrical Circuit A - Single 2-wire B - Single 3-wire B C - Single 4-wire D - Dual 2-wire E - Dual 3-wire F - Dual 4-wire Sheath Material A - 316 Stainless steel - AISI 316/1.4404 Head Type F - Ex d Aluminum S - Ex d Stainless steel G - SCCI Stainless steel N - SCCA Aluminum B - DIN B Aluminum D - BUZ Aluminum D E - BUZH Aluminum P - PR 7501 (N/A with FM approval) Y - Cast iron (N/A with FM approval) A - Polypropylene (N/A with FM approval) H - E&H Housing (N/A with FM approval) Instrument Connection - ½ Conduit Connection 2 - 1/2 NPT 2 N - ¾ NPT M - M20 x 1.5 A - Adapter M20 x 1.5 P - Pg 16 Instrument Connection - ¾ Conduit Connection 3 - 1/2 NPT 4 - ¾ NPT 5 - M20 x 1.5 of 7 Data Sheet S50 Industrial RTDs & Thermocouples with NPT Connections Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Inconel®. For more information, see Ashcroft Brands & Trademarks S50 Industrial RTDs
S50 RDT ORDERING CODE Example: (Cont'd) - X N-H9 R3 - - 3P T N=60 LN=400 Head Conduit Gland - - Without - P - Polyamide PA, for unarmored cable L - Nickel plated brass, for unarmored cable M - Nickel plated brass, single seal for braided cable N - Nickel plated brass, double seal for braided cable S - Stainless steel, for unarmored cable T - Stainless steel, single seal for braided cable U - Stainless steel, double seal for braided cable Inset Nominal Length X - LN=_(min=50, max=100000). Add actual nominal length in mm at end of ordering code LN=?? X Lag Extension and Length Lag length (add actual length N=?? At the end of code in mm) For DIN Mounting Plate 0--- - Without lag extension, without plug 0-4- - Without lag extension, with plug lag length (add actual length N=?? At the end of code in mm) B-H6 - Nipple AISI 316, N=40 M-H7 - Nipple AISI 316, N=100 (4˝) N-H9 - Nipple AISI 316, N= non std N-H9 U-J7 - Nipple-Union-Nipple AISI 316, N=120 N-J9 - Nipple-Union-Nipple AISI 316, N= not std For Spring-loaded Mounting (N/A with FM approval) N-S1 - Spring-loaded Nipple AISI 316 M-S4 - Spring-loaded Nipple-Union-Nipple 4˝ AISI 316, N=100 R-S6 - Spring-loaded Nipple-Union-Nipple 6˝ AISI 316, N=153 N-S9 - Spring-loaded Nipple-Union-Nipple AISI 316, N= not std Process Connection R3 - Thread 1/2 NPT R3 C3 - Compression fitting 1/2 NPT, AISI 316 A3 - Compression fitting G, AISI 316 (N/A with FM approval) -- - Without connection Electrical Connection For DIN Mounting Plate - - With DIN terminal block - 1 - With transmitter 3 - Without terminal block, with flying leads For Spring-loaded Mounting (N/A with FM approval) B - With terminal block T - With transmitter F - Without terminal block, with flying leads Certifications - - None required - F - FM A - ATEX X - IECEx S - SIL 2 + ATEX I - INMETRO D - ATEX + IECEX 2 - SIL 2 P - EAC (Gost R) + Metrological Russia Calibration Report -- - Without 3P - 3 points single 3P 5P - 5 points single 3D - 3 points dual 5D - 5 points dual Tagging - - Without T - Label in stainless steel with tag T Consult factory for additional configurations. Nominal length in mm Lag length in mm mm = inches x 25.4 of 7 Data Sheet S50 Industrial RTDs & Thermocouples with NPT Connections Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Inconel®. For more information, see Ashcroft Brands & Trademarks S50 Industrial RTDs
next pageS50 TC ORDERING CODE Example: S50 S T K N 1 1 3 D 2 Area Classification S - Standard - General purpose S D - Explosion proof (must order head type F or S) J - Intrinsic Safety - ia B - Intrinsic Safety - ib E - Increased Safety N - Non-Incendive Sheath Diameter R - 1∕8˝ Ø3.18 mm S - 3∕16˝ Ø4.76 mm T - 1/4˝ Ø6.35 mm T 3 - 3 mm 4 - 4.5 mm 6 - 6 mm 8 - 8 mm Thermocouple Type E - Temperature range: -200 to 800 °C J - Temperature range: -40 to 750 °C K - Temperature range: -200 to 1000 °C K N - Temperature range: -200 to 1000 °C T - Temperature range: -250 to 350 °C Accuracy or Class N - ANSI MC 96.1: Standard limits N S - ANSI MC 96.1: Special limits 1 - IEC 60584-2: Class 1 2 - IEC 60584-2: Class 2 3 - IEC 60584-2: Class 3 Junction 1 - Ungrounded 1 2 - Grounded 3 - Ungrounded, vibration-proof 4 - Grounded, vibration-proof Electrical Circuit 1 - Single 1 2 - Dual Sheath Material 1 - AISI 316 / 1.4401 3 - Inconel® 600/ 2.4816 3 Head Type F - Ex d Aluminum S - Ex d Stainless steel G - SCCI Stainless steel N - SCCA Aluminum B - DIN B Aluminum D - BUZ Aluminum D E - BUZH Aluminum P - PR 7501 (N/A with FM approval) Y - Cast iron (N/A with FM approval) A - Polypropylene (N/A with FM approval) H - E&H Housing (N/A with FM approval) Instrument Connection ½ NPT Conduit Connection 2 - 1/2 NPT 2 N - ¾ NPT M - M20 x 1.5 A - Adapter M20 x 1.5 P - Pg 16 Instrument Connection ¾ NPT Conduit Connection 3 - 1/2 NPT 4 - ¾ NPT 5 - M20 x 1.5 of 7 Data Sheet S50 Industrial RTDs & Thermocouples with NPT Connections Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Inconel®. For more information, see Ashcroft Brands & Trademarks S50 Thermocouples
S50 TC ORDERING CODE Example: (Cont'd ) - X N-H9 R3 - - 3P T N=60 LN=400 Head Conduit Gland - - Without - P - Polyamide PA, for unarmored cable L - Nickel plated brass, for unarmored cable M - Nickel plated brass, single seal for braided cable N - Nickel plated brass, double seal for braided cable S - Stainless steel, for unarmored cable T - Stainless steel, single seal for braided cable U - Stainless steel, double seal for braided cable Inset Nominal Length X - LN=_(min=50, max=100000) (add actual length LN=?? At the end of ordering code in mm) X Lag Extension and Length Lag length (add actual length N=?? At the end of code in mm) For DIN Mounting Plate 0--- - Without lag extension, without plug (select 0 lag length above ) 0-4- - Without lag extension, with plug B-H6 - Nipple AISI 316, N=40 M-H7 - Nipple AISI 316, N=100 (4˝) N-H9 - Nipple AISI 316, N= non std N-H9 U-J7 - Nipple-Union-Nipple AISI 316, N=120 N-J9 - Nipple-Union-Nipple AISI 316, N= not std For Spring-loaded Mounting (N/A with FM approval) N-S1 - Spring-loaded Nipple AISI 316 M-S4 - Spring-loaded Nipple-Union-Nipple 4˝ AISI 316, N=100 R-S6 - Spring-loaded Nipple-Union-Nipple 6˝ AISI 316, N=153 N-S9 - Spring-loaded Nipple-Union-Nipple AISI 316, N= not std Process Connection R3 - Thread 1/2 NPT R3 C3 - Compression fitting 1/2 NPT, AISI 316 A3 - Compression fitting G, AISI 316 (N/A with FM approval) -- - Without connection Electrical Connection For DIN Mounting Plate - - With DIN terminal block 1 - With transmitter 3 - Without terminal block, with flying leads For Spring-loaded Mounting (N/A with FM approval) B - With terminal block T - With transmitter F - Without terminal block, with flying leads Certifications - - None - F - FM 2 - SIL 2 A - ATEX S - SIL 2 + ATEX I - INMETRO X - IECEx D - ATEX + IECEX P - EAC (Gost R) + Metrological Russia Calibration Report -- - Without 3P - 3 points single 3P 5P - 5 points single 3D - 3 points dual 5D - 5 points dual Tagging - - Without T - Label in stainless steel with tag T Consult factory for additional configurations. Nominal length in mm Lag length in mm mm = inches x 25.4 of 7 Data Sheet S50 Industrial RTDs & Thermocouples with NPT Connections Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Inconel®. For more information, see Ashcroft Brands & Trademarks S50 Thermocouples
DIMENSIONS in [ ] are millimeters For reference only, consult Ashcroft for specific dimensional drawings. NN LL LNLN dd NN LL LNLN dd HOW TO ORDER S50 TEMPERATURE PROBES: The ordering code is built by selecting the appropriate configuration for the various sections. The insert nominal length LN is measured from base of the head to the tip of the probe. The lag extension length N is measured from the base of the head to the center of the threads on the lag extension. LN can be calculated by adding the lag extension length N to the probe insertion length L. The N length and the LN length are added to the end of the ordering code in millimeters. To convert inches to millimeters multiply by 25.4. mm = inches x 25.4 d = Stem diameter N = Lag extension length L = Insertion length LN = Insert nominal length LN = N + L DIN Mounting Plate Design Spring-loaded Mounting Design of 7 Data Sheet S50 Industrial RTDs & Thermocouples with NPT Connections Data Sheet All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: Inconel®. For more information, see Ashcroft Brands & Trademarks