S4E450-AU03-02 EBMPAPST | Alldatasheet
Document overview
- Manufacturer or author: MK_4183 / 2013-02-14
- PDF pages: 5
Technical content
sickled blades (S series) with guard grille for short nozzle S4E450-AU03-02 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 · D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership · Headquarters Mulfingen County court Stuttgart · HRA 590344 General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen County court Stuttgart · HRB 590142 Nominal data Type S4E450-AU03-02 Motor M4E094-EA Phase 1~ 1~ Nominal voltage VAC 230 230 Frequency Hz 50 60 Type of data definition ml ml Valid for approval / standard CE CE Speed min-1 1300 1490 Power input W 350 425 Current draw A 1.55 1.87 Motor capacitor µF 8 8 Capacitor voltage VDB 450 450 Max. back pressure Pa 120 50 Min. ambient temperature °C -40 -40 Max. ambient temperature °C 55 45 Starting current A 6.0 5.5 ml = Max. load · me = Max. efficiency · fa = Running at free air · cs = Customer specs · cu = Customer unit Subject to alterations Data according to ErP directive Installation category A Efficiency category Static Variable speed drive No Specific ratio* 1.00 * Specific ratio = 1 + pfs / 100 000 Pa Actual Request 2013 Request 2015 Overall efficiency ηes 32.9 26.6 30.6 Efficiency grade N 42.3 36 40 Power input Pe kW 0.33 Air flow qv m³/h 3920 Pressure increase pfs Pa 100 Speed n min-1 1325 Data established at point of optimum efficiency Item no. 12733-5-9980 · Revision 77504 · Release 2012-11-08 · Page 1 / 5
sickled blades (S series) with guard grille for short nozzle S4E450-AU03-02 Technical features Mass 7.3 kg Size 450 mm Surface of rotor Coated in black Material of terminal box ABS plastic Material of blades Press-fitted, coated sheet steel blank, sprayed with PP plastic Material of guard grille Steel, coated in black plastic (RAL9005) Number of blades 5 Direction of air flow "A" Direction of rotation Clockwise, seen on rotor Type of protection IP 54 Insulation class "F" Humidity class F4-1 Max. permissible ambient motor temp. (transp./ storage) +80 °C Min. permissible ambient motor temp. (transp./storage) -40 °C Mounting position Shaft horizontal or rotor on bottom; rotor on top on request Condensate discharge holes Rotor-side Operation mode S1 Motor bearing Ball bearing Touch current acc. IEC 60990 (measuring network Fig. 4, TN system) <= 3.5 mA Electrical leads Via terminal box, integrated capacitor connected via terminal box Motor protection Thermal overload protector (TOP) wired internally Protection class I (if protective earth is connected by customer) Product conforming to standard EN 60034-1 (2004); CE Approval CCC; GOST Item no. 12733-5-9980 · Revision 77504 · Release 2012-11-08 · Page 2 / 5
sickled blades (S series) with guard grille for short nozzle S4E450-AU03-02 Product drawing
1 Direction of air flow "A"
2 Tightening torque 0.8±0.15 Nm 3 Cable diameter: min. 6 mm, max. 12 mm, tightening torque: 2 ± 0.15 Nm Connection screen L = U1 = blue Z brown N = U2 = black PE green/yellow Item no. 12733-5-9980 · Revision 77504 · Release 2012-11-08 · Page 3 / 5
sickled blades (S series) with guard grille for short nozzle S4E450-AU03-02 Charts: Air flow 50 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 220 210 200 190 180 170 160 150 140 130 120 110 100 pfs_E[IN H2O] 0,85 0,8 0,75 0,7 0,65 0,6 0,55 0,5 0,45 0,4 0,35 0,3 0,25 0,2 0,15 0,1 0,05 p f s[Pa]1 Measurement: LU-71958 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. Measured values U V 230 230 230 230 f Hz n min-1 1380 1355 1340 1300 Pe W 272 299 321 350 I A 1.20 1.31 1.40 1.55 LwAin dB(A) qv m3/h 5770 5175 4410 3350 pfs Pa 120 U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · LwAin = Sound power level inlet side · qv = Air flow · pfs = Pressure increase Item no. 12733-5-9980 · Revision 77504 · Release 2012-11-08 · Page 4 / 5
sickled blades (S series) with guard grille for short nozzle S4E450-AU03-02 Charts: Air flow 60 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 16015515014514013513012512011511010510095908580757065605550454035302520151050 pfs_E[IN H2O] p f s[Pa] Measurement: LU-71963 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. Measured values U V 230 230 f Hz n min-1 1545 1490 Pe W 396 425 I A 1.74 1.87 LwAin dB(A) qv m3/h 6525 5695 pfs Pa U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · LwAin = Sound power level inlet side · qv = Air flow · pfs = Pressure increase Item no. 12733-5-9980 · Revision 77504 · Release 2012-11-08 · Page 5 / 5