Features
- Built-in output short-circuit protection circuit.
- Internal phase correction.
- No latch-up
- Wide same phase mode and differential voltage ranges
- High gain. low noise
Applications
- Active filters
- Audio amplifiers
- VCOs
- Other electronic circuits
Ordering Information
Type NO. Marking Package Code S4560 S4560 SOP-8 O u t l i n e D i m e n s i o n s u n i t : mm SSeemmiiccoonndduuccttoorr Block Diagram
A b s o l u t e m a x i m u m r a t i n g s Ta = 25 °C Characteristic Symbol Ratings Unit Supply voltage V CC ±18 V Differential input voltage V ID ±30 V Input voltage V IC -Vcc~Vcc V Power Dissipation P D* 550 mW Operating temperature Topr -40 ~ +85 °C Storage temperature Tstg -55 ~ +125 °C * Refer to Pd characteristics diagram. The values for the S4560 are those when it is mounted on a glass epoxy
Electrical Characteristics
(Unless otherwise specified. VCC = +15V , VEE=-15V and Ta = 25 °C) Characteristic Symbol Test Co ndition Min. Typ. Max. Unit Input offset voltage V IOS Rg ≤ 10 ㏀ - 0.5 6 mV Input offset current I IOS - - 5 200 nA Input bias current I IB - - 50 500 nA Input common mode Voltage Range VICR - ±12 ±14 - V RL≥ 10 ㏀ ±12 ±14 - V Maximum Output Voltage V OM Large signal Voltage Gain G V Vout=±10V, RL≥ 2 ㏀ 86 100 - dB Common mode rejection ratio CMRR Rg ≤ 10 ㏀ 70 90 - dB Power supply rejection ratio PSRR Rg ≤ 10 ㏀ - 30 150 uV/V Slew Rate SR GV=1, RL≥ 2 ㏀ - 4.0 - V/us Input conversion noise voltage Vn - - - 2.2 uV Gain band width product GBW f=10kHz - 10 - MHz
Electrical Characteristic Curves Fig. 4 V ICR - VCC / VEE Fig. 3 IIB - Ta Fig. 1 GV – f Fig. 2 VOP-P – f Fig. 6 IIB - VCC Fig. 5 IQ - VCC / V EE (Vcc/VEE=±15V ,RL=2 ㏀,Ta=25℃) (Vcc/V EE=±15V ,Ta=25℃) (Vcc/VEE=±15V) (Ta=25℃) (Ta=25℃) (Ta=25℃) / ±
These AUK products are intended for usage in general electronic equipments(Office and communication equipment, measuring equipment, domestic electrification, etc.). Please make sure that you consult with us before you use these AUK products in equipm- ents which require high quality and/or reliabi lity, and in equipments which could have major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic signal, combustion central, all types of safety device, etc.). AUK cannot accept liability to any damage which may occur in case these AUK products were used in the mentioned equipments without prior consultation with AUK.