S4558 AUK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Features

  • Power consumption as small as about 50mW (typ.)
  • Built-in output short-circuit protecting circuit.
  • Internal phase consumption type.
  • No latch-up
  • Wide same phase mode and differential voltage ranges
  • High gain. low noise

Applications

  • Active filters
  • Audio amplifiers
  • VCOs
  • Other electronic circuits

Ordering Information

Type NO. Marking Package Code S4558 S4558 SOP-8 O u t l i n e D i m e n s i o n s u n i t : mm SSeemmiiccoonndduuccttoorr Block Diagram

Characteristic Symbol Ratings Unit Supply voltage V CC 36 or ±18 V Differential input voltage V IND 30 V Input voltage V IN ±15 V Power Dissipation P D 300 mW Operating temperature Topr -45 ~ +85 °C Storage temperature Tstg -55 ~ +150 °C

Electrical Characteristics

(Unless otherwise specified. VCC = +15V , VEE=-15V and Ta = 25 °C) Characteristic Symbol Test Co ndition Min. Typ. Max. Unit Input offset voltage V IOS Rg ≤ 10 ㏀ - 0.5 6 mV Input offset current I IOS - - 5 200 nA Input bias current I IB - - 60 500 nA Input common mode Voltage Range VICR - ±12 ±14 - V RL≥ 10 ㏀ ±12 ±14 - V Maximum Output Voltage V OM Large signal Voltage Gain G V Vout=±10V, RL≥ 2 ㏀ 86 100 - dB Common mode rejection ratio CMRR Rg ≤ 10 ㏀ 70 90 - dB Power supply rejection ratio PSRR Rg ≤ 10 ㏀ - 30 150 uV/V Slew Rate SR GV=1, RL≥ 2 ㏀ - 1.0 - V/us Supply Current I CC - - 4.0 6.0 mA Equivalent input noise voltage VNI RIAA, RS=1 ㏀, f=30 ㎐~30 ㎑ - 2.5 - uVrms Source Current I SOURCE - 27 - - mA Sink Current I SINK - 27 - - mA

Electrical Characteristic Curves Fig. 6 V NI - f Fig. 1 GV - f Fig. 2 VOP-P - f Fig. 5 VOP-P - RL Fig. 4 VOM - VCC, VEE Fig. 3 IIB - Ta

These AUK products are intended for usage in general electronic equipments(Office and communication equipment, measuring equipment, domestic electrification, etc.). Please make sure that you consult with us before you use these AUK products in equipm- ents which require high quality and/or reliabi lity, and in equipments which could have major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic signal, combustion central, all types of safety device, etc.). AUK cannot accept liability to any damage which may occur in case these AUK products were used in the mentioned equipments without prior consultation with AUK.