S32B-2011BA SICK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 9

Technical content

A B C D E F H I J K L M N O P Q R S T S32B-2011BA | S300 Mini SAFETY LASER SCANNERS Illustration may differ

Ordering information

Type Part no. S300 Mini Standard 270° 2 m 3 S32B-2011BA 1050932 Other models and accessories www.sick.com/S300_Mini Detailed technical data

Features

Sub product family S300 Mini Standard Application Indoor Protective field range 2 m Warning field range 8 m (at 15 % reflectivity) Distance measuring range 30 m Type of field set Triple field sets Number of field sets 1 Number of fields 3 Number of monitoring cases 1 Scanning angle 270° Resolution (can be configured) 30 mm, 40 mm, 50 mm, 70 mm Angular resolution 0.5° Response time 80 ms 1) Protective field supplement 100 mm Number of multiple samplings 2 ... 16, configurable Delay of automatic reset 2 s ... 60 s, configurable 1) Depending on basic response time and multiple sampling. Safety-related parameters Type Type 3 (IEC 61496) Safety integrity level SIL 2 (IEC 61508) Category Category 3 (EN ISO 13849)

2 SAFETY LASER SCANNERS | SICK Product data sheet | 2024-04-25 15:36:22

Subject to change without notice

S32B-2011BA | S300 Mini SAFETY LASER SCANNERS Performance level PL d (EN ISO 13849) PFHD (mean probability of a dangerous fail- ure per hour) 8.0 x 10-8 TM (mission time) 20 years (EN ISO 13849) Safe state in the event of a fault At least one OSSD is in the OFF state. Functions Restart interlock ✔ External device monitoring (EDM) ✔ Multiple sampling ✔ Contour as a reference ✔ Measured data output None Interfaces Connection type Cable, 250 mm, with male connector M12, 8-pin Universal I/Os 2 Inputs External device monitoring (EDM) 1 1) Reset/restart 1 1) Standby 1 1) Outputs Output signal switching devices (OSSDs) 2 Outputs for warning field 2 1) Reset required 1 1) Configuration method PC with CDS (Configuration and Diagnostic Software) Configuration and diagnostics interface RS-232 Transmission rate 38.4 kBaud 1) Availability depends on the configuration of the universal I/Os. Electrical data Protection class III (EN 50178, EN 60950) Supply voltage Vs 24 V DC (16.8 V DC ... 30 V DC) Power consumption ≤ 0.2 A 1) ≤ 1.35 A 2) 1) At 24 V DC without output load. 2) At 24 V DC including maximum output load. Mechanical data Dimensions (W x H x D) 102 mm x 116 mm x 105 mm Weight 0.8 kg, without connecting cables Housing material Aluminum die cast Housing color RAL 1021 (yellow), RAL 9005 (black) Optics cover material Polycarbonate Optics cover surface finish Outside with scratch-resistant coating 2024-04-25 15:36:22 | Product data sheet Subject to change without notice SAFETY LASER SCANNERS | SICK 3

A B C D E F H I J K L M N O P Q R S T S32B-2011BA | S300 Mini SAFETY LASER SCANNERS Ambient data Enclosure rating IP65 (EN 60529) Ambient operating temperature –10 °C ... +50 °C Storage temperature –25 °C ... +50 °C Vibration resistance IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3 Class 5M1 (IEC 60721-3-5) Shock resistance IEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3 Class 5M1 (IEC 60721-3-5) Continuous shock 50 m/s², 11 ms 100 m/s², 16 ms Other information Type of light Pulsed laser diode Wave length 905 nm Detectable remission factor 1.8 % ... > 1,000 %, reflectors Laser class 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1) Classifications ECLASS 5.0 27272705 ECLASS 5.1.4 27272705 ECLASS 6.0 27272705 ECLASS 6.2 27272705 ECLASS 7.0 27272705 ECLASS 8.0 27272705 ECLASS 8.1 27272705 ECLASS 9.0 27272705 ECLASS 10.0 27272705 ECLASS 11.0 27272705 ECLASS 12.0 27272705 ETIM 5.0 EC002550 ETIM 6.0 EC002550 ETIM 7.0 EC002550 ETIM 8.0 EC002550 UNSPSC 16.0901 39121528

4 SAFETY LASER SCANNERS | SICK Product data sheet | 2024-04-25 15:36:22

Subject to change without notice

S32B-2011BA | S300 Mini SAFETY LASER SCANNERS Dimensional drawing (Dimensions in mm (inch)) Laser scanner Ø 94 (3.70) 116 (4.57) 79.7 (3.14) 43.3 (1.70) 36.5 (1.44) 73 (2.87) 102 (4.02) Max. 200 (7.87) 104 (4.09) 54.5 (2.15) 36.4 (1.43) 23.8 (0.94) M5 x 7.5 (0.50) 10.5 250 (9.84) 43.3 (1.70) 2024-04-25 15:36:22 | Product data sheet Subject to change without notice SAFETY LASER SCANNERS | SICK 5

A B C D E F H I J K L M N O P Q R S T S32B-2011BA | S300 Mini SAFETY LASER SCANNERS Connection diagram S300 mini standard to UE10-3OS safety relay UE10-3OS B1 B3 Y1 13 33 23 41 B2 B4 Y2 14 34 24 42 +24 V FE 0 V E112608/00/2014-03-06 BN GN YE PK BU FE WH GY S300 Mini Standard H H = Housing S300 Mini Standard on UE10-3OS safety relay Operating mode: with restart interlock (universal I/O 1 must be configured as reset) and external device monitoring (universal I/O 2 must be configured as EDM)

6 SAFETY LASER SCANNERS | SICK Product data sheet | 2024-04-25 15:36:22

Subject to change without notice

S32B-2011BA | S300 Mini SAFETY LASER SCANNERS S300 Mini Standard with restart interlock and external device monitoring BN GN YE PK BU FE WH GY k2 k1 x x y y z z S300 Mini Standard E112600/00/2014-03-06 H K1 K2 H1 H = Housing +24 V FE 0 V S300 Mini Standard in conjunction with relays/contactors Operating mode: with restart interlock (universal I/O 1 must be configured as reset) and external device monitoring (universal I/O 2 must be configured as EDM) Comments 1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z path) is only possible with a single-channel control and by taking the risk analysis into account. Recommended accessories Other models and accessories www.sick.com/S300_Mini Brief description Type Part no. Mounting brackets and plates 1 piece, mounting bracket for rear mounting on wall or machine Mounting kit 1a 2034324 1 piece, mounting bracket for rear mounting on wall or machine with protection of op- tics hood Mounting kit 1b 2034325 1 piece, mounting bracket, adjustable lateral axis, only in conjunction with mounting kit 1a (2034324) or 1b (2034325) Mounting kit 2 2039302 2024-04-25 15:36:22 | Product data sheet Subject to change without notice SAFETY LASER SCANNERS | SICK 7

A B C D E F H I J K L M N O P Q R S T S32B-2011BA | S300 Mini SAFETY LASER SCANNERS Brief description Type Part no. 1 piece, mounting plate, adjustable longitudinal axis, only in conjunction with mount- ing kit 2 (2039302) Mounting kit 3 2039303 Plug connectors and cables

  • Connection type head A: Female connector, M12, 8-pin, straight
  • Connection type head B: Flying leads
  • Signal type: Sensor/actuator cable
  • Cable: 2.5 m, 7-wire, PUR, halogen-free
  • Description: Sensor/actuator cable, shielded
  • Connection systems: Flying leads DOL-127SG2M5E25KM0 2076540
  • Connection type head A: Male connector, M8, 4-pin, straight
  • Connection type head B: Male connector, USB-A, straight
  • Cable: 2 m, 4-wire, PVC
  • Description: Unshielded, Configuration cable with integrated RS-232 transducer on USB for connecting a sensor configuration connection (M8, 4-pin) to the USB inter- face of a PC DSL-8U04G02M025KM1 6034574
  • Connection type head A: Male connector, M8, 4-pin, straight
  • Connection type head B: Male connector, USB-A, straight
  • Cable: 10 m, 4-wire, PVC
  • Description: Unshielded, Configuration cable with integrated RS-232 transducer on USB for connecting a sensor configuration connection (M8, 4-pin) to the USB inter- face of a PC DSL-8U04G10M025KM1 6034575

8 SAFETY LASER SCANNERS | SICK Product data sheet | 2024-04-25 15:36:22

Subject to change without notice

SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com