Self-Contained, AC-Operated Sensors

  • Featuring EZ-BEAM ® technology, the specially designed optics and electronics provide reliable sensing without the need for adjustments
  • 30 mm plastic threaded barrel sensor in opposed, retroreflective, or fixed-field sensing modes
  • Completely epoxy-encapsulated to provide superior durability, even in harsh sensing environments rated to IP69K
  • Innovative dual-indicator system takes the guesswork out of sensor performance monitoring
  • 20 V ac to 250 V ac (3-wire hookup); SPST solid-state switch output, maximum load 300 mA WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Sensing Mode Model1 Output Range LED OPPOSED S303E — 60 m (196.8 ft) Infrared, 950 nmS30AW3R LO S30RW3R DO P POLAR RETRO S30AW3LP LO 6 m (19.7 ft) Visible red, 680 nmS30RW3LP DO FIXED-FIELD S30AW3FF200 LO 200 mm (7.9 in) cutoff Infrared, 880 nm S30RW3FF200 DO S30AW3FF400 LO 400 mm (15.7 in) cutoff S30RW3FF400 DO S30AW3FF600 LO 600 mm (23.6 in) cutoff S30RW3FF600 DO Fixed-Field Mode Overview S30 Sensor self-contained fixed-field sensors are small, powerful, infrared diffuse mode sensors with far-limit cutoff (a type of background suppression). Their high excess gain and fixed-field technology allow detection of objects of low reflectivity, while ignoring background surfaces. The cutoff distance is fixed. Backgrounds and background objects must always be placed beyond the cutoff distance. 1 Standard 2 m (6.5 ft) cable models are listed.
  • 9 m (30 ft) cable: add suffix "W/30" (for example, S303E W/30).
  • 4-pin Micro-style QD models: add suffix "Q1" (for example, S303EQ1). A model with a QD connector requires a mating cable. S30 Sensors AC-Voltage Series Original Document 121519 Rev. A

30 December 2015

Supply Voltage and Current 20 av V to 250 V ac (50 Hz to 60 Hz) Average current: 20 mA Peak current: 200 mA at 20 V ac 500 mA at 120 V ac 750 mA at 250 V ac Supply Protection Circuitry Protected against transient voltages Output Configuration SPST solid-state ac switch; three-wire hookup; light operate or dark operate, depending on model Light Operate: Output conducts when sensor sees its own (or the emitter’s) modulated light Dark Operate: Output conducts when the sensor sees dark Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to http:// www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 Output Rating 300 mA maximum (continuous) Fixed-Field models: derate 5 mA/°C above +50° C (+122° F) Inrush capability: 1 amp for 20 ms, non-repetitive OFF-state leakage current: < 100 mA ON-state saturation voltage: 3 V at 300 mA ac; 2 V at 15 mA ac Output Protection Circuitry Protected against false pulse on power-up Output Response Time Opposed mode: 16 ms ON, 8 ms OFF Other models: 16 ms ON and OFF NOTE: 100 ms delay on power-up; outputs do not conduct during this time. Repeatability Opposed mode: 2 ms Other models: 4 ms Repeatability and response are independent of signal strength Indicators Two LEDs (Green and Yellow) Green ON steady: power to sensor is ON Yellow ON steady: sensor sees light Yellow flashing: excess gain marginal (1 to 1.5 times) in light condition Construction PBT polyester housing; polycarbonate (opposed-mode) or acrylic lens Environmental Rating Leakproof design rated NEMA 6P, DIN 40050 (IEC IP69K) Connections 2 m (6.5 ft) attached cable, or 4-pin Micro-style quick-disconnect fitting Operating Conditions Temperature: − 40 °C to +70 °C ( − 40 °F to +158 °F) Humidity: 90% at +50 °C maximum relative humidity (non- condensing) Vibration and Mechanical Shock All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 Hz to 60 Hz, max., double amplitude 0.06 inch acceleration 10G). Method 213B conditions H&I. (Shock: 75G with unit operating; 100G for non-operation) Certifications Performance Curves Table 1: Opposed Mode Sensors Beam Pattern Excess Gain 0250 mm500 mm750 mm 250 mm500 mm 750 mm 010"20"30" 10"20" 30" DISTANCE S30 SeriesOpposed Mode 100 1000 EXCESS GAIN DISTANCE S30 Series Opposed Mode S30 Sensors AC-Voltage Series 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 121519 Rev. A

Table 2: Polarized Retro Mode Sensors2 Beam Pattern Excess Gain 050 mm100 mm150 mm 50 mm100 mm 150 mm 02"4"6" 2"4" DISTANCE S30 SeriesPolarized Retro with BRT-3 Reflector 100 1000 EXCESS GAIN DISTANCE S30 Series Polarized Retro with BRT-3 Reflector Table 3: Fixed-Field Mode Sensors Excess Gain3 Fixed-Field — 200 mm Fixed-Field — 400 mm Fixed-Field — 600 mm 100 EXCESS GAIN DISTANCE

1000 S30 Series

Fixed-field modewith 200 mm farlimit cutoff Ø 16 mm spot size at 35 mm focus Ø 20 mm spot size at 200 mm cutoff Using 18% gray test card: cutoff distance will be 95% of value shown. Using 6% black test card: cutoff distance will be 90% of value shown. 100 EXCESS GAIN DISTANCE Fixed-field modewith 400 mm farlimit cutoff Ø 17 mm spot size at 35 mm focus Ø 25 mm spot size at 400 mm cutoff Using 18% gray test card: cutoff distance will be 90% of value shown. Using 6% black test card: cutoff distance will be 85% of value shown. 100 EXCESS GAIN DISTANCE Fixed-field modewith 600 mm farlimit cutoff Ø 17 mm spot size at 35 mm focus Ø 30 mm spot size at 600 mm cutoff Using 18% gray test card: cutoff distance will be 85% of value shown. Using 6% black test card: cutoff distance will be 75% of value shown. 2 Performance based on use of a model BRT-3 retroreflector (3-inch diameter). Actual sensing range may be more or less than specified, depending on the efficiency and reflective area of the retroreflector used. 3 Performance based on use of a 90% reflectance white test card. Focus and spot sizes are typical. S30 Sensors AC-Voltage Series P/N 121519 Rev. A www.bannerengineering.com - Tel: +1-763-544-3164 5

Yellow LEDOutput Indicator Green LEDPower Indicator 2 m (6.5') Cable Jam Nuts(2 Provided) M30 x 1.5Thread QD Models Wiring Diagrams Cabled Emitters bn bu 20-250V ac QD Emitters (4-pin Micro-Style) 20-250V ac No connection rd/wh rd/bk rd gn All Other Cabled Models bn bu bk 20-250V ac Load All Other QD Models (4-pin Micro-Style) 20-250V ac No Connection Load rd/wh rd rd/bk gn Cordsets All measurements are listed in millimeters (inches), unless noted otherwise. 4-Pin Micro-Style Cordsets Model Length Style Dimensions Pinout (Female) MQAC-406 1.83 m (6 ft) Straight 42 Typ. ø 14.51/2-20 UNF-28 1 = Red/Black 2 = Red/White 3 = Red 4 = Green MQAC-415 4.57 m (15 ft) MQAC-430 9.14 m (30 ft) MQAC-406RA 1.83 m (6 ft) Right-Angle

32 Typ

28 Typ

ø 14.5 1/2-20 UNF-28 MQAC-415RA 4.57 m (15 ft) MQAC-430RA 9.14 m (30 ft) S30 Sensors AC-Voltage Series 6 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 121519 Rev. A

Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. S30 Sensors AC-Voltage Series www.bannerengineering.com - Tel: +1-763-544-3164