S200R MINMAX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

+Vo Bipolar Push-Pull Inverter +Vin -Vin Com. -Vo Positive Regulator Negative Regulator LC Filter Single Output +Vo Bipolar Push-Pull Inverter +Vin -Vin -Vo Positive Regulator LC Filter Block Diagram Low NoiseI/O Isolation 500 VDC Low Cost Minmax's S200R Model 2W DC/DC's are specially designed to provide 40mA output ripple, continuous short circuit in a low-profile 24-pin DIP package. The series consists of 20 models with input voltages of 5V, 12V, 24V and 48VDC which offers regulated output voltages of 5V, 12V, 15V, {12V and {15VDC. The -25] to +71] operating temperature range makes it ideal for data communication equipments, mobile battery driven equipments, distributed power systems, telecommunication equipments, mixed analog/digital subsystems, automatic test instrumentation and industrial robot systems. y Internal SMD Construction y UL 94V-0 Package Material y Short Circuit Protection y Temperature Performance -25] to +71] y Output 5, 12, 15, {12 and {15VDC y Input 5, 12, 24 and 48VDC y 40mV P-P Ripple and Noise y MTBF > 800,000 Hours y 500VDC Isolation y Low Cost Key Features 2W, Low Cost DIP, Single & Dual Output DC/DC Converters S200R Series REV:0 2005/04MINMAX1

5180{66{15S220R 5180{83{12S219R 597013315S218R 597016512S217R 1010 4005 (43.2 ~ 52.8) S216R 61135{66{15S215R 61135{83{12S214R 6113513315S213R 6113516512S212R 1520 163 4005 (21.6 ~ 26.4) S211R 59280{66{15S210R 59280{83{12S209R 6226513315S208R 5629516512S207R 3040 330 4005 (10.8 ~ 13.2) S206R 51770{66{15S205R 53740{83{12S204R 5769013315S203R 5473016512S202R 8080 800 4005 (4.5 ~ 5.5) S201R % (Typ.)mA (Typ.)mA (Typ.)mA (Typ.)mAmAVDCVDC @Max. Load@No Load@Max. LoadMin.Max. EfficiencyReflected Ripple Current Input CurrentOutput CurrentOutput Voltage Input Voltage Model Number Model Selection Guide Free-Air ConvectionCooling %95---Humidity ]+125-40Storage Temperature ]+90-25CaseOperating Temperature ]+71-25AmbientOperating Temperature UnitMax.Min.ConditionsParameter Environmental Specifications Exceeding the absolute maximum ratings of the unit could cause damage. These are not continuous operating ratings. mW3,000---Internal Power Dissipation ]260---Lead Temperature (1.5mm from case for 10 Sec.) VDC55-0.748VDC Input Models VDC30-0.724VDC Input Models VDC15-0.712VDC Input Models VDC7.5-0.75VDC Input Models Input Surge Voltage ( 1000 mS ) UnitMax.Min.Parameter Notes : 1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 50% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. All DC/DC converters should be externally fused at the front end for protection. 5. Other input and output voltage may be available, please contact factory. 6. Specifications subject to change without notice. Absolute Maximum Ratings S200R Series 2MINMAXREV:0 2005/04

KHz---8040Switching Frequency pF150100---100KHz,1VIsolation Capacitance UnitMax.Typ.Min.ConditionsParameter General Specifications ContinuousOutput Short Circuit %/]{0.02{0.01---Temperature Coefficient mV P-P5040---Ripple & Noise (20MHz) %{0.5{0.2---Io=10% to 100%Load Regulation %{0.5{0.2---Vin=Min. to Max.Line Regulation %{3.0{1.0---Dual Output, Balanced LoadsOutput Voltage Balance %{4.0{2.0---Output Voltage Accuracy UnitMax.Typ.Min.ConditionsParameter Output Specifications Pi FilterInput Filter All Models Reverse Polarity Input Current 52.84843.248V Input Models 26.42421.624V Input Models 13.21210.812V Input Models VDC 5.554.55V Input ModelsInput Voltage Range UnitMax.Typ.Min.ModelParameter Input Specifications # For each output uF220220470470470Maximum Capacitive Load Unit{15V #{12V #15V12V5VModels by Vout Capacitive Load 135mA Slow - Blow Type350mA Slow - Blow Type700mA Slow - Blow Type1500mA Slow - Blow Type 48V Input Models24V Input Models12V Input Models5V Input Models Input Fuse Selection Guide S200R Series REV:0 2005/04MINMAX3

Derating Curve ( all other output )Derating Curve ( 5V output only ) ]Ambient Temperature Output Power (%) 100 -25 50 60 80 100 110 9070 400LFM 200LFM100LFM Natural convection ]Ambient Temperature Output Power (%) 100 -25 50 60 80 100 110 9070 400LFM 200LFM100LFM Natural convection Efficiency vs Output Load ( Dual Output )Efficiency vs Output Load ( Single Output ) Load Current (%) Efficiency (%) 10060402010 8020 Load Current (%) Efficiency (%) 10060402010 80 Efficiency vs Input Voltage ( Dual Output )Efficiency vs Input Voltage ( Single Output ) Efficiency (%) Input Voltage (V) NomLow High30 Efficiency (%) Input Voltage (V) NomLow High S200R Series 4MINMAXREV:0 2005/04

Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. Peak-to-Peak Output Noise Measurement Test Use a Cout 0.33uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. Design & Feature Considerations Maximum Capacitive Load The S200R series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 220uF maximum capacitive load for dual outputs and 470uF capacitive load for single outputs. The maximum capacitance can be found in the data sheet. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0[ at 100 KHz) capacitor of a 2.2uF for the 5V input devices, a 1.0uF for the 12V input devices and a 0.47uF for the 24V and 48V devices. Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 1.5uF capacitors at the output. Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90°C. The derating curves are determined from measurements obtained in an experimental apparatus. S200R Series REV:0 2005/04MINMAX5 +Out -Out +Vin -Vin DC / DC Converter Load Battery + Lin+ Cin To Oscilloscope Current Probe +Out -Out +Vin -Vin Dual Output DC / DC Converter Resistive Load Scope Copper Strip Cout Com. ScopeCout +Out -Out +Vin -Vin Single Output DC / DC Converter Resistive LoadScope Copper Strip Cout +Out -Out +Vin -Vin DC / DC Converter LoadDC Power Source Cin +Out -Out +Vin -Vin Load DC Power Source CoutCom. Dual Output DC / DC Converter +Out -Out +Vin -Vin Load DC Power Source Cout Single Output DC / DC Converter DUT Position of air velocity probe and thermocouple 50mm / 2in Air Flow 15mm / 0.6in

The S200R converter is encapsulated in a low thermal resistance molding compound that has excellent resistance/electrical characteristics over a wide temperature range or in high humidity environments. The encapsulant and unit case are both rated to UL 94V-0 flammability specifications. Leads are tin plated for improved solderability. NC: No Connection +Vin+Vin24 -VoutNC23 CommonNC22 Common-Vout15 +Vout+Vout14 UL94V-0:Flammability-Vin-Vin13 -Vin-Vin12 12.1g:Weight+Vout+Vout11 Common-Vout10 Non-Conductive Black Plastic:Case MaterialCommonNC3 -VoutNC2 1.25*0.80*0.40 inches+Vin+Vin1 31.8*20.3*10.2 mm:Case Size Dual OutputSingle OutputPin Physical CharacteristicsPin Connections {0.002{0.05Pin X.XXX{0.005X.XX{0.13 X.XX{0.01X.X{0.25 InchesMillimetersTolerance Dual Output Single Output 31.8 [1.25] 10.2 [0.40] 20.3 [0.80] 2.0 [0.08] Bottom 3.8 [0.15] Side 1 23 1 1 10 12 15 14 132324 22 0.50 [0.020] 2.54 [0.100] 15.22 [0.600] 2.5 [0.10] Connecting Pin Patterns Top View ( 2.54 mm / 0.1 inch grids ) Mechanical Dimensions S200R Series 8MINMAXREV:0 2005/04