Technical content
- Low power loss, high efficiency
- For surface mounted applications RoHS
- Low forward voltage drop COMPLIANT
- Trench schottky technology
- Meet UL flammability classification 94V-0 Mechanical Data
- Case: JEDEC TO-277A molded plastic
- Polarity: As marked on the body
- Mounting position: Any
Applications
- For use in low voltage, high frequency inverters, polarity protection applications Maximum Ratings and Electrical Characteristics Rating at 25℃ ambient temperature unless otherwise specified. Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. Symbol Unit VRRM V IF(AV)1 IF(AV)2 IF=5.0A IF=7.5A IF=15.0A IF=5.0A IF=7.5A IF=15.0A uA mA RθJA ℃/W RθJM ℃/W TJ ℃ TSTG ℃ Notes: 1. Mounted on 30 mm x 30 mm pad areas aluminum PCB . 2. Free air, mounted on recommended copper pad area . 3. 300uS pulse width, 2%duty cycle. 4. The typical data above is for reference only . S15P45-13-00/99-00/01 Rev. 11, 18-May-2020 A V 210 Junction to Pad 4 Typical Thermal Resistance Junction to Ambient 75 Peak Forward Voltage (Note3) TA=25℃ TA=125℃ VF IR Junction Temperature Range -55 to+150 Storage Temperature Range -55 to+150 0.42 (TYP.) 0.51 (MAX.) Maximum DC Reverse Current @TJ=25℃ 1500 (MAX.) at Rated DC Blocking Voltage @TJ=125℃ 15 (TYP.) 50 (MAX.) 0.45 (TYP.) 0.49 (TYP.) 0.58 (MAX.) 0.31 (TYP.) 0.34 (TYP.) www.hygroup.com.tw Peak Forward Surge Current, 8.3mS Single Half Sine-Wave, Superimposed on Rated Load (JEDEC Method) 0.40 (TYP.) IFSM Note: Products with logo or are made by HY Electronic (Cayman) Limited. A 4.8 Maximum Average Forward Rectified Current S15P45 Reverse Voltage - 45Volts Forward Current - 15.0 Amperes Package Outline Dimensions in Inches (Millimeters) Pb Surface Mount Schottky Barrier Recitifiers Characteristics S15P45 Maximum Repetitive Peak Reverse Voltage 45 All d ata sheet.com
Rating and Characteristic Curves S15P45 The curve above is for reference only. S15P45-13-00/99-00/01 Rev. 11, 18-May-2020 FIG. 5 - Forward Power Loss Characteristics Average Power Loss(W) Average Forward Current (A) 0 2 4 6 8 10 12 14 16 18 D=1.0 D=0.1 D=0.3 D=0.2 D=0.5 D=0.8 Instantaneous Reverse Current (mA) Fig. 3 - Typical Reverse Characteristics 0.01 0.1 100 20 40 60 80 100 TJ=25°C TJ=75°C TJ=100°C TJ=125°C Percent of Rated Peak Reverse Voltage (%) 0.1 0 0.2 0.4 0.6 0.8 1 TJ=25°C TJ=75°C TJ=100°C TJ=125°C Pulse Width 300uS 2%Duty Cycle Fig. 4 - Typical Forward Characteristics Instantaneous Forward Current (A) Instantaneous Forward Voltage (V) 0 50 100 150 200 Fig. 1 - Forward Current Derating Curve Average Forward Current (A) Case Temperature (℃) In DC Mode 100 150 200 250 1 10 100 Peak Forward Surge Current (A) Number of Cycles at 60Hz Fig. 2 - Maximum Non-Repetitive Surge Current 8.3mS Single Half-Sine-Wave (JEDEC METOD) Wth Heatsink Wthout Heatsink All d ata sheet.com
ALL specifications and data are subject to be changed without notice to improve reliability function or design or other reasons. HY makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the co- tinuing production of any product. To the maximum extent permitted by applicable law, HY disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,consequential or incidental d- amages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merch- antability. Statements regarding the suitability of products for certain types of applications are based on HY’s knowledge of typical require- ments that are often placed on HY products in generic applications. Such statements are not binding statements about the suitabi- lity of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application.Parameters provided in datasheets and specific- ations may vary in different applications and performance may vary over time. All operating parameters, including typical paramet- ers, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify HY’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, HY products are not designed for use in medical, life-saving, or life-sustaining applicati- ons or for any other applications in which the failure of the HY product could result in personal injury or death. Customers using or selling HY products not expressly indicated for use in such applications do so at their own risk.Please contact authorized HY pers- onnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of HY. Product names and markings noted herein may be trademarks of their respective owners. Rev. 11, 18-May-2020 Disclaimer All d ata sheet.com