S1333NH BELDEN | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
General Description:
18 AWG stranded (7x26) tinned copper conductors, polyolefin insulation, individual and overall Beldfoil®
shields (100% coverage), tinned copper drain wire, LSZH jacket. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 24 18 7x26 TC - Tinned Copper Total Number of Conductors: 48 Insulation Insulation Material: Insulation Material PO - Polyolefin Inner Shield Inner Shield Material: Inner Shield Trade Name Type Inner Shield Material Coverage (%) Beldfoil® Tape Aluminum Foil-Polyester Tape 100 Inner Shield Drain Wire AWG: AWG Stranding Conductor Material 20 7x28 TC - Tinned Copper Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Coverage (%) Beldfoil® Tape Aluminum Foil-Polyester Tape 100.000 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 18 7x26 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Haloarrest® FRPE - Flame Retardant Polyethylene Outer Jacket Ripcord: Yes Overall Cable Overall Nominal Diameter: 1.130 in. Pair Pair Color Code Chart: Number Color
1 Blue and Orange and Numbered 1
2 Blue and Orange and Numbered 2
3 Blue and Orange and Numbered 3
4 Blue and Orange and Numbered 4
5 Blue and Orange and Numbered 5
6 Blue and Orange and Numbered 6
7 Blue and Orange and Numbered 7
8 Blue and Orange and Numbered 8
9 Blue and Orange and Numbered 9
10 Blue and Orange and Numbered 10
11 Blue and Orange and Numbered 11
12 Blue and Orange and Numbered 12
13 Blue and Orange and Numbered 13
14 Blue and Orange and Numbered 14
15 Blue and Orange and Numbered 15
Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION S1333NH Multi-Conductor - DataBus® ISA/SP-50 FOUNDATION Fieldbus or PROFIBUS Cable
16 Blue and Orange and Numbered 16
17 Blue and Orange and Numbered 17
18 Blue and Orange and Numbered 18
19 Blue and Orange and Numbered 19
20 Blue and Orange and Numbered 20
21 Blue and Orange and Numbered 21
22 Blue and Orange and Numbered 22
23 Blue and Orange and Numbered 23
24 Blue and Orange and Numbered 24
Pair Lay Length & Direction: Lay Length (in.) Twists (twist/ft) 2.000 6.000 Mechanical Characteristics (Overall) Operating Temperature Range: -30°C To +90°C UL Temperature Rating: 90°C Max. Recommended Pulling Tension: 1377 lbs. Min. Bend Radius/Minor Axis: 11.300 in. Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM, ITC, PLTC CEC/C(UL) Specification: CM EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 11/07/2007 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 Vertical Tray Flame Test IEC Flame Test: 60332-3-24 (Category C) Suitability Suitability - Indoor: Yes Suitability - Outdoor: Yes Sunlight Resistance: Yes Oil Resistance: No Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Unaveraged Impedance: Freq. (MHz) Impedance (Ohm) 0.031 100.000 Nom. Inductance: Inductance (µH/ft) 0.190 Nom. Capacitance Conductor to Shield: Capacitance (pF/ft) 45.000 Nom. Mutual Capacitance: Capacitance (pF/ft) 24.000 Maximum Capacitance Unbalance: Page 2 of 3 09-11-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION S1333NH Multi-Conductor - DataBus® ISA/SP-50 FOUNDATION Fieldbus or PROFIBUS Cable
Capacitance (pF/ft) 1.200 Nominal Velocity of Propagation: VP (%) 66.000 Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/1000 ft) 5.860 Nominal Outer Shield DC Resistance: DCR @ 20°C (Ohm/1000 ft) 4.900 Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 7.500 Ohm/1000 ft Nom. Attenuation: Freq. (MHz) Attenuation (dB/100 ft.) 0.039 0.080 Max. Attenuation: Freq. (MHz) Attenuation (dB/100 ft.) 0.039 0.091 Max. Operating Voltage - UL: Voltage
300 V RMS
Max. Recommended Current: Description Current Per Conductor 5.2 Amps Other Electrical Characteristic 1: Max. Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft Other Electrical Characteristic 2: 31.25 KBits/sec Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc Revision Number: 0 Revision Date: 04-06-2011 © 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 3 of 3 09-11-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION S1333NH Multi-Conductor - DataBus® ISA/SP-50 FOUNDATION Fieldbus or PROFIBUS Cable