S12-AH5-5VP21 STANDEX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

standexelectronics.comDatasheet Rev BCA Page 1 +1 970.879.9900 | sensorsales@standexelectronics.com S12-AH5-5VP21 Analog Hall Sensor  Analog hall, 2.5V offset  5.0 mV/G gain  5V input voltage  Stainless 12x1mm x 35mm housing  Free end PVC 22 AWG wires (1 foot length) Part Description: S 12 - AH 5 - 5 VP 21 Housing Sensor Type & Function Electrical Option Connection Type S = Stainless Steel, Thread Pitch M12x1, 35mm Long Analog Hall, 5mV/G 5V Input Voltage P21 = Free End PVC 22AWG Wires Analog Output Proportional to Field Strength, Gap or Height CUSTOMER FOCUSED ENGINEERING + MODULAR DESIGN HOUSING - Aluminum, stainless steel, plastic, threaded, flange mount, customer specific ELECTRICAL - Every sensor function available in various electrical options (NPN, PNP, TTL, etc.) CONNECTION - Deutsch, Amphenol, many other brands, free end wires, pigtails, any length Need a Custom Sensor Solution?... Send us your application specific requirements at sensorso.com Modify, update, or enhance any sensor with our modular features and functionality.

DESCRIPTION

  • The AH5 Analog Hall Sensor provides an analog output that changes in relation to the magnetic field strength perpendicular to the sensor's face. These sensors are polarity sensitive.
  • No field present provides a 2.5V output (offset voltage), this output changes by 5.0 mV per gauss (gain).
  • Other gain options available, contact our Sales Engineer to discuss your requirements
  • The Ratiometric version (-5V) has an output voltage proportional to the supply voltage. A regulated version (-RG) is available.
  • For resolving the height, position, and movement of external magnets, the amplitude of current traveling down a conductor, the magnitude of field present in an electro- coil, etc.

FEATURES

  • Low Cost, Potted and Sealed
  • Ratiometric or Regulated
  • Shock & Vibration Resistant
  • Solid State (Nothing to wear out!)
  • Infinite Resolution

standexelectronics.comDatasheet Rev BCA Page 2 +1 970.879.9900 | sensorsales@standexelectronics.com Environmental Specifications Corrosion Resistance 500 hours salt spray ASTM B-117 Installation Torque 23 Foot-Pounds Maximum Enclosure Nema 1,3,4,6,13 & IEC IP67 Vibration 10 G’s 2 to 2000 Hz Sinusodal Mechanical Shock 100 G’s, 11 mS Half-Sine S12-AH5-5VP21 Analog Hall Sensor Electrical Specifications Conditions Min Max Unit Temperature Range* Operating -40 +110 Deg C Supply Voltage, Vcc Over temperature +4.5 +5.5 Volts DC Supply Current Into Vcc Io = 0 +2 +10 mA Frequency Range 8x over sample 0 30 kHz Saturation Voltage High I out = 1 mA Typ .2 0.4 Volts Saturation Voltage Low I out = 1 mA, Vcc = 5 V 4.5 Typ 4.7 Volts ESD (Human Body Model) Nondestructive - 8000 Volts EMI (Human Body Model) 20k to 1 G Hz - 100 V / M * T max = 150°C is available, contact factory. Rev B Absolute Max Limits Min Max Unit Supply Voltage, Vcc -0.1 +8 Volts DC Voltage Applied to Output -0.1 +8 Volts Current Into Output - 10 mA Current Out of Output - 10 mA Load Dump, 40 mS - TBD Volts Magnetic Characteristics Min Typ Max Units Quiescent Vo (0 Gauss, Vcc=5, T=25°C) 2.4 2.5 2.6 Volts Change in Q-Vo Over Temp -.030 0 +.030 Volts Sensitivity at Vcc = 5, T = 25°C 4.5 5.0 5.5 mV/G Change in Sensitivity at T = 150°C -2.5 +2.5 +7.5 % Change in Sensitivity at T = -40°C -9 -1.3 +1 % We also offer analog output Hall Effect sensors with several different offset voltages and gains. PAH and PAM sensors are also available programmed to your application. Contact us or check our website to see other Analog Hall sensors. Note: Check our website or contact us to discuss all of our magnetic speed, count, and position detection sensors. South pole increases output voltage 5.0 mV/Gauss North pole decreases output voltage 5.0 mV/Gauss

standexelectronics.comDatasheet Rev BCA Page 3 +1 970.879.9900 | sensorsales@standexelectronics.com Please note: All technical specifications on this series datasheet refer to the standard product range. Modifications in the sense of technical progress are reserved. For general information only. For more specific information, please consult the product datasheet, available upon request. This series datasheet could contain technical inaccuracies or typographical errors. Changes are periodically made to the information herein. These change will be incorporated in future revisions. For deviating values, most current specifications and products please contact your nearest sales office. S12-AH5-5VP21 Analog Hall Sensor Handling Instructions DO NOT CONTACT FACE TO FACE CONTACT WITH OTHER MAGNETS MAY REDUCE THE MAXIMUM OPERATING GAP Date Code ‘YYM’ YY = YEAR, M = MONTH A JAN D APR H JUL L OCT B FEB E MAY J AUG M NOV C MAR G JUN K SEP N DEC 5V, 5V Operation SENSOR LOAD 4.5 TO 5.5V Vo u t 0-5V (Ea ch Cha nne l) GND Magnet Detecon S12-AH5 Connections Chart Red Vcc Green Analog Vout Black Ground P21-AH5 Marking CHARACTERISTIC-OPTION MARKED ON THIS SURFACE XX = ELECTRICAL OPTION DATE CODE, THIS SURFACE AH5-5V 06A