GaAs Push Pull, 40 – 1000MHz, 22dB min. Gain @ 1000MHz, 270mA max. @ 24VDC

FEATURES

40 – 1000MHz 22dB min. Gain @ 1000MHz 270mA max. @ 24VDC

  • Excellent linearity
  • Superior return loss performance
  • Extremely low distortion
  • Optimal reliability
  • Extremely low noise
  • Unconditionally stable under all terminations APPLICATION
  • 40 to 1000 MHz CATV amplifier systems

DESCRIPTION

  • Hybrid Push Pull amplifier module employing GaAs dice LIMITING VALUES In accordance with the Absolute Maximum Rating System (IEC 60134) SYMBOL PARAMETER MIN. MAX. UNIT Vi RF input voltage (single tone) - 75 dBmV Vov DC supply over-voltage (5 minutes) - 30 V Tstg storage temperature - 40 + 100 °C Tmb operating mounting base temperature - 30 + 100 °C CHARACTERISTICS Table 1: S-Parameter, Noise Figure, DC Current; VB = 24V; Tmb = 30°C; ZS = ZL = 75 Ω SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT f = 50 MHz 21.0 21.5 22.0 dB Gp power gain f = 1000 MHz 22.0 23.5 dB SL slope 1) f = 40 to 1000 MHz 0.5 2.0 dB FL flatness of frequency response f = 40 to 1000 MHz - ±0.4 dB f = 40 to 160 MHz 20.0 - dB S11 input return loss f = 160 to 1000 MHz 18.0 - dB f = 40 to 160 MHz 20.0 - dB S22 output return loss f = 160 to 870 MHz 18.0 - dB f = 870 to 1000 MHz 15.0 - dB F noise figure f = 50 to 1000 MHz - 2.5 3.5 dB Itot total current consumption (DC) 260.0 270.0 mA Notes: 1) The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency. Page 1 of 4 2005 April 06 Document Revision Level A

GaAs Push Pull, 40 – 1000MHz, 22dB min. Gain @ 1000MHz, 270mA max. @ 24VDC CHARACTERISTICS Table 2: Distortion data 40 – 870 MHz; VB = 24V; Tmb = 30°C; ZS = ZL = 75 Ω SYMBOL CONDITIONS MIN. TYP. MAX. UNIT CTB 132 ch. flat; Vo = 40 dBmV 1) - - 66 - 64 dBc XMOD 132 ch. flat; Vo = 40 dBmV 1) - - 59 - 57 dBc CSO 132 ch. flat; Vo = 40 dBmV 1) - - 66 - 64 dBc Notes: 1) 132 channels, NTSC frequency raster: 55.25 MHz to 865.25 MHz, +40 dBmV flat output level. Composite Second Order (CSO) The CSO parameter (both sum and difference products) is defined by the NCTA. Composite Triple Beat (CTB) The CTB parameter is defined by the NCTA. Cross Modulation (XMOD) Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the carrier being tested. Page 2 of 4 2005 April 06 Document Revision Level A

GaAs Push Pull, 40 – 1000MHz, 22dB min. Gain @ 1000MHz, 270mA max. @ 24VDC 123 4 5 6 7 89 INPUT GND GND +VB GND GND OUTPUT Pinning: min max A4 4,4 B1 3,4 C1 9,9 D 7,85 8,15 E 12,45 12,75 F3 7,9 G 3,95 4,2 H3 ,8 I2 5,2 K4 ,0 L2 7,0 M1 1,1 N5 ,4 O 0,23 0,27 P 0,42 0,48 Q 2,24 2,84 R 2,04 3,04 S 2,29 2,79 T 4,83 5,33 U 4,83 5,33 nominal 44,6 ±0 ,2 13,6 ±0 ,2 20,4 ±0 ,5 8 ±0 ,15 12,6 ±0 ,15 38,1 ±0 ,2 4 ±0 ,2 25,4 ±0 ,2 4 +0,2 / -0,05 UNC6-32 4,2 ±0 ,2 27,2 ±0 ,2 11,6 ±0 ,5 5,8 ±0 ,4 0,25 ±0 ,02 0,45 ±0 ,03 2,54 ±0 ,3 2,54 ±0 ,5 2,54 ±0 ,25 5,08 ±0 ,25 5,08 ±0 ,25 44,8 13,8 20,9 38,3 4,2 25,6 4,4 27,4 12,1 6,2 All Dimensions in mm: European Projection Notes: 51 0mm0 scale 123 5 7 89 R O Q M 51 0mm0 scale B N L F A D H øG T S PJ U I E C K Page 3 of 4 2005 April 06 Document Revision Level A

GaAs Push Pull, 40 – 1000MHz, 22dB min. Gain @ 1000MHz, 270mA max. @ 24VDC DEFINITIONS Data Sheet Status Objective Product Specification This data sheet contains target or goal specifications for product development. Preliminary Product Specification This data sheet contains preliminary data; supplementary data may be published later. Product Specification This data sheet contains final product specifications. Limiting values Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 60134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability.

Application information

Where application information is given, it is advisory and does not form part of the specification. Premier Devices reserves the right to make changes without further notice to any products herein. Premier Devices makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose, nor does Premier Devices assume any liability arising out of the application or use of an y product or circuit, and specifically discl aims any and a ll l iability, includi ng without limitation consequential or incidental damages. “Ty pical” parameters which ma y be p rovided in Premier D evices datashee ts and/or specifications c an and do var y in diffe rent applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer´s technical exper ts. Premier Devices d oes not convey any license under its patent rights nor the rights of others. Premie r D evices pr oducts are no t designe d, intended, or authorized fo r u se as components in sy stems intended for surgical implant into t he body, or othe r applications intended to support or sustain life, or for any other application in which the failure of the Premier Devices product could create a situation where personal injury or death may occur. Should Buy er purch ase or use Premier Devices pr oducts for an y such unintended or unauthorized ap plication, Buy er shall indemnify and hold Pr emier Devices and its officers , employees, subsidiaries, affiliates, and distributors harmle ss against all cl aims, costs, damages, and e xpenses, and re asonable attorne y fees arising out of, directly or indirectly, and claim of personal injur y or death associated with such unintended or unauthorized use, even if such claim alleges that Premier Devices was negligent regarding the design or manufacture of the part. © Premier Devices Germany GmbH 2004 How to contact us: Premier Devices Germany GmbH Loeffelholzstrasse 20, D-90441 Nuernberg, Germany Phone: +49 (0) 911 9411 233, FAX: +49 (0) 911 9411 198, Email: sales.germany@premierdevices.com, Internet: http://www.premierdevices.de/ Page 4 of 4 2005 April 06 Document Revision Level A