RSI-10-000-A E-T-A | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

INTELLIGENT POWER DISTRIBUTION SYSTEMS RSI10 RSI10 The RSI10 Remote Signalling Interface ensures reliable and early detection of critical system conditions. It can communicate with all circuit protectors installed in the ControlPlex® Rack via internal BUS connection. When one of the circuit protectors is disconnec- ted from the related load due to an overcurrent etc., the RSI10 w ill externally indicate this status via a potential-free group signal, e.g. to a monitoring system. It is the perfect way to minimise downti- mes and reduce operational and maintenance costs. INTELLIGENT POWER DISTRIBUTION SYSTEMS RSI10 TYPICAL FEATURES YOUR BENEFITS

  • Rated voltage DC 20...75 V
  • Integrated BUS interface
  • External term inals, tw o plug-in type 3-pole screw term inals w ith mating connector
  • Early failure detection through external alarm ing
  • Extended potential-free fault signalling (overvoltage, low voltage, short circuit, overcurrent, excess temperature etc.)
  • Enhanced alarm indication on site by means of integral LED
  • Easy retrofitting without system downtimes
  • Conveniently accessible contact term inals on the front side
  • Technologically /f_it for the future: Designed to be compatible for fu- ture system extensions through the RCI11 rem ote control and m o- nitoring module TYPICAL APPLICATIONS COMPLIANCE Telecommunications and datacom, energy providers, industrial swit- ching and control systems, rail engineering, infrastructure WEB LINKS Further information, Installation Instruction, International approvals, Technical basics, REACH , RoHS , Contact global.e-t-a.com 1225

INTELLIGENT POWER DISTRIBUTION SYSTEMS RSI10 GENERAL INFORMATION FURTHER INFORMATION Installation Instruction https://www.e-t-a.com/datei/13849 TECHNICAL DATA (T u = +25 °C, U b = DC 48 V) ELECTRICAL DATA Rated voltage range DC 20...75 V (Power-D-Box ® CP - input voltage) Dielectric strength DC 100 V for 1 ms Power consumption I Typ. 25 mA at DC 48 V operating voltage Power consumption Typ. 1.2 W External connection Two plug-in type 3-pole screw terminals with mating connector LED for operating condition signallingMulticoloured (red, green, blue)

  • Status LEDs MECHANICAL DATA Mounting position Vertical, cooling Convection cooling Mass Approx. 60 g AUXILIARY CIRCUIT (ALARM CONTACTS) Contact Potential-free change-over contact Max. switching voltage DC 72 V Interrupting capacity 60 W / 62.5 VA AMBIENT CONDITIONS Ambient temperature -20...+60 °C (without condensation, cf. EN 60204-1) Storage temperature -20...+70 °C Damp heat Test according to IEC 60068-2-78, 3K6 climate class according to EN 60721 96 hours at 95 % relative humidity, 40 °C Vibration Test according to IEC 60068-2-6, test Fc 3 g Actuating area IP code (standard) IP20 (when rack is fully populated and SUB-D connectors are plugged in) Terminal area IP code (standard) IP00 ESD 4 kV / air 8 kV EMC requirements (EMC directive, CE logo) emitted interference EN 61000-6-3 EMC requirements (EMC directive, CE logo) resistance to disturbances EN 61000-6-2 FURTHER INFORMATION OPERATING CONDITIONS: LED STATUS INDICATION ESX300-S-3xx circuit protector opera- ting status Load output ESX300- S-3xx circuit protec- tor LED status RSI10 module Auxiliary contact RSI10 module Group signal "break con- tact” Operating condition RSI10 module No fault -> Device OFF Locked Green Open Normal operation Normal operation Connected Green Open Normal operation global.e-t-a.com 1225

INTELLIGENT POWER DISTRIBUTION SYSTEMS RSI10 Undervoltage fault with device in OFF con- dition (15 V < U < 37 V) Locked Green Closed Normal operation Undervoltage fault with device in OFF con- dition (U > 72V) Locked Green Closed Normal operation Overcurrent fault detected (I > In < 1.2 x In). The overcurrent must be detected for approx. 30 s before tripping is effected. Connected Green Open Normal operation Overcurrent fault or short circuit discon- nection Locked Green Closed Normal operation Error undervoltage (U > 15 V < 37 V)Connected Green Closed Normal operation Error overvoltage (72 V < U < 75 V)Connected Green Closed Normal operation Error: no voltage Locked O FF (green)1 Closed Normal operation1 Error excess temperature Locked Green Closed Normal operation - - Green Closed No ESX300-S circuit protector available Check if ESX300-S bus version is plugged in - - Red Closed Internal RSI10 error or internal bus error - - 5 sec blue Open One new circuit pro- tector ESX300-S was identified 1 In a redundant system w ith tw o supply voltage sources, the LED lights up green if only one voltage source fails, otherw ise the RSI10 m odule is de-energised. ORDERING NUMBER CODE R S I A

1 TYPE NUMBER

RSI Remote Signalling Interface

2 VERSION

10 Standard, pluggable (front plate, w ithout enclosure)

3 INTERNAL INTERFACES

0 With EL-BUS interface (standard)

4 VOLTAGE RANGE (SUPPLY)

0 DC 20...75 V

5 EXTERNAL INTERFACES

0 Potential-free group signal connection

6 EXTERNAL CONNECTION

A 2 x 3-pole, screw term inals, pluggable COMPLIANCE CE according to EMC directive (EN 61000-6-3 & EN 61000-3-2) global.e-t-a.com 1225

INTELLIGENT POWER DISTRIBUTION SYSTEMS RSI10 Compliance accord- ing to EN60950-1 / UL60950-1 DIMENSIONS DIMENSIONS ACCESSORIES OPTIONAL ACCESSORIES FROM CP Pow er-D-Box® for Con- trolPlex® Rack The Power-D-Box ® CP is a modular power distribution system. Depending on the respective application, the compact 2 HU enclosure can accommo- date these system components: ESX300-S, RSI10, RCI11 oder EAI300. User friendliness is of top priority in the event of a system extension with the sys- tem live w ithout causing dow ntim es. All sub-assem blies are hot-sw appable without affecting neighbouring components. Depending on the application, term ination can be placed both on the front or on the rear. M ajor applicati- on areas of the ControlPlex® Rack system are com m unication technolo- gy equipment both in the negative (DC -48 V or DC -60 V) and in the positive voltage range (DC 2 4 V, 48 V, 6 0 V). FURTHER PRODUCTS

RELATED PRODUCTS

ESX300-S minus The hot pluggable ESX300-S minus electronic circuit protector ensures re- liable overcurrent protection by means of electronic current limitation and load disconnection. It reliably prevents the destruction of electronic sub-as- semblies or load lines in power supply systems in a voltage range of DC -48 V and DC -6 0 V. Thanks to a selective load disconnection, a voltage dip is prevented in the event of a failure and other faultless devices in the circuit re- main working. The integral bus interface can transmit the recorded measuring values and status messages to the RCI11 control interface, where they can be used to automatically trigger actions or for data collection and monitoring. global.e-t-a.com 1225

INTELLIGENT POWER DISTRIBUTION SYSTEMS RSI10 ESX300-S plus The hot pluggable ESX300-S plus electronic circuit protector ensures reliable overcurrent protection by means of electronic current limitation and load dis- connection. It reliably prevents the destruction of electronic sub-assem blies or load lines in pow er supply system s in DC +2 4 V, DC +48 V and DC +6 0 V voltage ranges. Thanks to its selective load disconnection, a voltage dip is prevented in the event of a failure and fault-free devices can be further ope- rated. The integral bus interface can transmit the recorded measuring values and status messages to the RCI11 control interface, where they can be used to automatically trigger actions or for data collection and monitoring. RCI11 The RCI11 Remote Control Interface allows remote control and monitoring of the system and its connected loads, reducing maintenance costs and provi- ding maximum transparency. It helps integrate the ControlPlex® Rack sys- tem into the network surroundings and into the centralised corporate ma- nagement system. The RCI11 provides access to all installed ESX300-S cir- cuit protectors via the internal bus system and can enquire or store individual measuring data, status conditions and fault indications and forward them to the superordinate control unit or execute com m ands from the control unit for controlling purposes. The RCI11 Remote Control Interface can be extended during operation “Hot Plug & Play“. EAI300 Combined with the RCI11, the EAI300 External Alarm Interface allows record- ing of external sensor data and alarm signalling in the management system. It includes e.g. additional monitoring and indication of door contacts or tempe- rature sensors in the technical room . This provides high system transparency and fast intervention in the event of alarms. Thanks to programmable logical links, operating conditions of the ESX300-S can be linked to external encoder signals that enable automatic switching operations. Instead of the ESX300-S electronic circuit protector, the EAI300 can be easily plugged into an empty slot of the ControlPlex® Rack system without shutting down the connected loads. This allows connection of external signalling devices in the control ca- binets without requiring additional space. All information and data given on our products are accurate and reliable to the best of our knowledge, but E-T-A does not accept any responsibility for the use in applications which are not in accordance with the present specification. E-T-A reserves the right to change specifications at any time in the interest of technical improvement. Dimensions are subject to change without notice. Please enquire for the latest dimensional drawing with tolerances if required. All dimensions, data, pictures and descriptions are for information only and are not binding. Amendments, errors and omissions excepted. Ordering part numbers may differ from the device marking. global.e-t-a.com 1225