RSD1_V01 BANNER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 21
Technical content
Datasheet sections
- 1 Product Description
- 1.1 Models
- 1.2 Overview
- 1.3 Features and Indicators
- 1.3.1 Display
- 1.3.2 RSD1 Buttons
- 2 Installation
- 2.1 Mounting Instructions
- 2.2 Wiring Diagrams
- 2.3 Connection Options
- 2.3.1 Connecting the RSD1 to a Sensor
- 2.3.2 Connecting the RSD1 to a Control System
- 3 Programming a Sensor with the RSD1
- 3.1 RSD1 Menu (MENU)
- 3.2 Sensor Configuration Menu (CONFIG)
- 3.2.1 Import
- 3.2.2 Name
- 3.2.3 Export
- 3.2.4 Delete
- 3.2.5 Detail
- 3.3 Input Menu (RSD1 IN)
- 3.3.1 Input Active
- 3.3.2 Input Type
- 3.3.3 Input Switch
- 3.4 Display Menu (DISPLAY)
- 3.4.1 View
- 3.4.2 Sleep
- 3.5 Lock, Unlock, and OpLock Menu (LOCK)
- 3.5.1 Unlock
- 3.5.2 Lock
- 3.5.3 OpLock
- 3.6 Information Menu (INFO)
- 3.6.1 Diags
- 3.7 Reset Menu (RESET)
- 3.8 End Menu (END)
- 3.9 Factory Default Settings
- 3.10 Remote Input
- 4 Specifications
- 4.1 Dimensions
- 5 Display Menu Full Map
- 6 Accessories
- 6.1 Brackets
- 6.2 Cordsets
- 7 Troubleshooting
- 7.1 Errors
- 8 Contact Us
199621 Rev. A
27 August 2018
© Banner Engineering Corp. All rights reserved 199621
1 Product Description
- Allows for configuration of remote sensor heads
- Easy to set up and use with a 2-line, 8-character display
- Ability to display live distance measurement
- Ability to save up to 6 unique configurations
- Not required for continuous operation of configured sensor(s)
1.1 Models
1.2 Overview
1.3 Features and Indicators
Figure 1. RSD1 Display Features indication of the connected sensor status.
1.3.1 Display
Figure 2. RSD1 Display in Run Mode measurements of the connected sensor.
1.3.2 RSD1 Buttons
Press Down and Up to:
- Navigate the menu systems
- Change programming settings When navigating the menu systems, the menu items loop. Press Down and Up to change setting values. Press and hold the buttons to cycle through numeric values. After changing a setting value, the value slowly flashes until the change is saved using the Enter button. Enter Button Press Enter to:
- Confirm selection
- Save changes In the RSD1 Menu, a check mark in the lower right corner of the display indicates that pressing Enter accesses a submenu. Press Enter to save changes. New values flash rapidly, and the sensor returns to the parent menu. Escape Button Press and hold Escape for 4 seconds to:
- Access the RSD1 Menu while in Run mode Press Escape to:
- Leave the current menu and return to the parent menu Important: Pressing Escape discards any unsaved programming changes. In the RSD1 Menu, a return arrow in the upper left corner of the display indicates that pressing Escape returns to the parent menu. Press and hold Escape for 2 seconds to return to Run mode from the RSD1 Menu. RSD1 Remote Display
2 Installation
2.1 Mounting Instructions
- Hook the DIN rail clip on the bottom of the RSD1 over the edge of the DIN rail (1). 2. Push the RSD1 up on the DIN rail (1). 3. Pivot the RSD1 onto the DIN rail, pressing until it snaps into place (2). Remove from a DIN Rail 1. Push the RSD1 up on the DIN rail (1). 2. Pivot the RSD1 away from the DIN rail and remove it (2).
2.2 Wiring Diagrams
The following wiring diagrams are examples of different RSD1 outputs. Wiring is dependent on the sensor connected to the RSD1. Dual Discrete shield 12–30 V dc D1_Out D2_Out Input Load NPN PNP * User-configurable PNP/NPN setting Load or Discrete Analog (Current) shield 12-30V dc D_Out A_Out Input Load * User-configurable PNP/NPN setting 4-20 mA NPN or PNP Discrete Analog (Voltage) shield 12-30V dc D_Out A_Out Input Load * User-configurable PNP/NPN setting NPN or PNP 0-10V Note: When connecting a 5-pin sensors to the RSD1, a double-ended 5-pin to 5-pin cordset is optional. When connecting a 4-pin sensor to the RSD1, a double-ended 4-pin to 5-pin adapter cordset is required.
2.3 Connection Options
When connecting the RSD1 to a sensor or control system, an adapter may be required depending on the sensor. For additional information on how to connect the RSD1, see the information below. Note: RSD1 pin-5 (gray wire) is used to communicate with an attached sensor. RSD1 Remote Display
2.3.1 Connecting the RSD1 to a Sensor
Connector Connection Options 5-Pin (5-Wire) When connecting the RSD1 to a sensor with a 5-pin connector, a double-ended 5-pin cordset can be used to extend the distance between the RSD1 and the sensor.
- See MQDEC3-5xxSS 4-Pin (4-Wire) When connecting the RSD1 to a sensor with a 4-pin connector, an adapter is required to connect RSD1 pin-5 to pin-2 of the sensor.
- See MQDC-45xxSS When connecting the RSD1 to a sensor with a 4-pin connector, a double-ended corset can be used in addition to the adapter to extend the distance between the RSD1 and the sensor.
- See MQDEC3-5xxSS
2.3.2 Connecting the RSD1 to a Control System
When connecting the RSD1 to a control system, there are many combinations of double-ended and flying leads that can be used to fit your application needs. See sensor specific literature for additional cordset options. Note: A 5-pin to 4-pin converter cable (MQDEC-54xxSS) may be required when connecting to an I/O block if pin-2 on the sensor is configured for remote input. RSD1 Remote Display
3 Programming a Sensor with the RSD1
For sensor programming information, reference the literature specific to the connected sensor. Figure 3. Access Menus Using the RSD1
3.1 RSD1 Menu (MENU)
To access the RSD1 Menu, press and hold the Escape button > 4 seconds while in Run Mode. Figure 4. RSD1 Menu Map See Display Menu Full Map on page 15 and the Menu sections of this manual for more information.
3.2 Sensor Configuration Menu (CONFIG)
configuration data is imported, the ability to export the configurations is available.
Figure 5. RSD1 Configuration Menu
3.2.1 Import
If the user configuration slot is empty, it is available to import from the remote sensor. configuration slot contains configuration data.
3.2.2 Name
The name of the selected configuration slot can be modified.
3.2.3 Export
If a sensor configuration has been imported, the user configuration data can be exported to a connected remote sensor.
3.2.4 Delete
A configuration slot can be cleared by deleting the user configuration data. slot name will be deleted as well to show that the configuration slot no longer contains user configuration data.
3.2.5 Detail
The specific details of the remote sensor that was used to import configuration data will be available to review.
3.3 Input Menu (RSD1 IN)
- Input polarity
- Remote input detection settings or or Go Back to Parent Menu Select Menu Item Press to Save Setting Press and Hold to Go Back to Run Mode Active Auto Hi(PNP) Low(NPN) Disable Sensor RSD1 Type No Yes Switch RSD in = Default value
Figure 6. RSD1 Input Menu Map
3.3.1 Input Active
The Active option sets the remote input polarity.
3.3.2 Input Type
The Type option sets the input type. programming information, reference the literature specific to the connected sensor. the attached sensor. For more information, see Remote Input on page 13.
3.3.3 Input Switch
The Switch option sets external remote input pulse acceptance.
No Does not allow external remote input pulses to modify remote input selection type.
3.4 Display Menu (DISPLAY)
- RSD1 display orientation
- RSD1 sleep mode settings or or Go Back to Parent Menu Select Menu Item Press to Save Setting Press and Hold to Go Back to Run Mode View Normal Invert Sleep Dis a ble 1 min 5 min 15 m i n 60 m i n RSD D i sp = Default value
Figure 7. Display Menu Map
3.4.1 View
not right-reading, invert the display for readability. The Down and Up buttons do not change when the display is inverted. Figure 8. RSD1 Normal Display Orientation Figure 9. RSD1 Inverted Display Orientation
3.4.2 Sleep
mode or menu, press any button. RSD1 sleep settings are independent of the sleep settings of a connected sensor.
3.5 Lock, Unlock, and OpLock Menu (LOCK)
or accidental programming changes. Unlock the RSD1 to allow programming changes. be made to an attached sensor. Figure 10. RSD1 Lock Menu Map
3.5.1 Unlock
The RSD1 display can be unlocked to allow programming changes.
3.5.2 Lock
The RSD1 display can be locked to prevent unauthorized or accidental programming changes.
3.5.3 OpLock
The RSD1 display can be locked while still allowing for the export of user configuration data using the OpLock feature.
3.6 Information Menu (INFO)
information. Select one of these options to view specific information for the connected sensor. This information is read-only.
3.6.1 Diags
3.7 Reset Menu (RESET)
the factory default settings. Figure 11. RSD1 Reset Menu Map
3.8 End Menu (END)
Select the END menu option to return the RSD1 to Run Mode.
3.9 Factory Default Settings
Locked, Unlocked or OpLock Unlocked
3.10 Remote Input
Use the remote input to program the RSD1 remotely. Activate remote input using the RSD1 buttons to navigate to the RSD1 Input Type menu option. For Active Low, connect the gray input wire to ground (0 V dc), with a remote switch connected between the wire and ground. To use the Active High function, configure the sensor for Active High using the buttons on the sensor, then connect the gray input wire to V+ (12 V dc to 30 V dc). Pulse the remote input according to the diagram and the instructions provided in this manual. The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds. Exit remote programming modes by holding the remote input low for > 2 seconds, or waiting for the automatic 60-second timeout, or by pressing and holding Escape for 2 seconds. The sensor returns to Run mode without saving any new settings. 15x Enter Export Mode Enter Selection Mode Export configuration slot 1 Disable remote input Set remote input to SRSD1 mode 0.04 seconds < T < 0.8 seconds Timing between Pulse groups > 1 second Pulse Timing (T) 2x Export configuration slot 2 3x Export configuration slot 3 4x Export configuration slot 4 5x Export configuration slot 5 6x Export configuration slot 6 Sensor Mode Set remote input to Sensor mode2x Run Mode RSD1 Remote Display
4 Specifications
Use only with suitable Class 2 power supply
12 V dc to 30 V dc:
- Max. load of 330 Ω for analog current (4 mA to 20 mA)
15 V dc to 30 V dc:
- Max. load of 500 Ω for analog current (4 mA to 20 mA) Power and Current Consumption Maximum Power Consumption: < 3.6 W (At 30 V dc, 119 mA) with 2 discrete outputs at 50 mA load each Power Consumption, Normal Run Mode with No Load: < 0.6 W (At 30 V dc, 19 mA) Supply Protection Circuitry Protected against reverse polarity and transient overvoltages Output Configuration Analog output: 4 to 20 mA or 0 to 10 V, depending on sensor Discrete output rating: Discrete NPN/PNP, depending on sensor Note: 2 ms output delay with white wire Output Ratings Discrete Output: 50 mA maximum (protected against continuous overload and short circuit) OFF-state leakage current–PNP: < 10 µA at 30 V OFF-state leakage current–NPN: < 200 µA at 30 V Output saturation voltage–PNP outputs: < 3 V at 50 mA Output saturation voltage–NPN outputs: < 2 V at 50 mA Analog current output: 330 kΩ max. at 24 V; max. load resistance = [(Vcc-4.5)/0.02 Ω] Analog voltage output: 2.5 kΩ min. load resistance Connection Integral 150 mm (6 in) PVC cable with 5-pin M12/Euro-style quick disconnect Construction Housing: Polycarbonate Environmental Rating IEC IP65 Operating Temperature Storage Temperature Vibration and Mechanical Shock All models meet MIL-STD-202G, Method 201A requirements. Also meets IEC 60947-5-2. Vibration: 10 Hz to 60 Hz maximum, 0.06 inch (1.52 mm) double amplitude, 10G maximum acceleration per IEC 60947-5-2. MIL-STD-202G, Method 213B, Condition I (100G 6x along X, Y and Z axes, 18 shocks), with sensor operating. Also meets IEC 947-5-2 requirements: 30G 11 ms duration, half sine wave. Certifications
4.1 Dimensions
78.0[3.07] 68.0[2.68] M12 X 1 - 6H M12 X 1 - 6g 37.4[1.47] 38.9[1.53] 28.0[1.10] All measurements are listed in millimeters [inches], unless noted otherwise. RSD1 Remote Display
5 Display Menu Full Map
Figure 12. RSD1 Full Menu Map
6 Accessories
6.1 Brackets
DIN-35-.. 35 mm DIN Rail Model Length DIN-35-70 70 DIN-35-105 105 DIN-35-140 140 L = 70, 105 or 140 mm L 35 Hole center spacing: 35.1 Hole size: 25.4 x 5.3 All measurements are listed in millimeters, unless noted otherwise.
6.2 Cordsets
The following cordsets can be used to extend the distance between the sensor and RSD1. 5-Pin Male Threaded and 5-Pin Female Quick Disconnect M12/Euro-Style Cordset—Double Ended Model Length "L1" Style Pinout MQDEC3-503SS 0.31 m (1 ft) Female Straight/ Male Straight Male 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Grey MQDEC3-506SS 1.83 m (6 ft) MQDEC3-515SS 4.58 MQDEC3-530SS 9.20 M12 X 1.0 - 6 g 14.5 ø 5.9 14.5 “L1” 47.4 47.4 M12 X 1.0 - 6 H Female 3 2 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Grey The following cordsets can be used to connect the RSD1 to a 4-pin sensor. RSD1 Remote Display
4-Pin Female and 5-Pin Male Threaded M12/Euro-Style Cordset—Double Ended Model Length "L1" Style Pinout MQDC-4501SS 0.31 m (1 ft) Female Straight/ Male Straight Male 1 = Brown 2 = Not Used 3 = Blue 4 = Black 5 = White MQDC-4506SS 1.83 m (6 ft) M12 X 1.0 43.5 ± 0.5 “L1” ø 5.9 M12 X 1.0 ø 14.5 ø 14.5 40 ± 0.5 Female 3 4 1 = Brown 2 = White 3 = Blue 4 = Black The following cordsets can be used to connect the RSD1 to a control system using the white wire (pin-2) as remote input for Remote TEACH, Laser Off, Laser On. 4-Pin Male and 5-Pin Female Threaded M12/Euro-Style Cordsets—Double Ended Model Length "L1" Style Pinout MQDC-5401SS 0.31 m (1 ft) Female Straight/ Male Straight Male 1 4 2 3 1 = Brown 2 = White 3 = Blue 4 = Black MQDC-5406SS 1.83 m (6 ft) M12 X 1.0 43.5 ± 0.5 “L1” ø 5.9 M12 X 1.0 ø 14.5 ø 14.5 40 ± 0.5 Female 3 2 1 = Brown 2 = Not Used 3 = Blue 4 = Black 5 = White RSD1 Remote Display
7 Troubleshooting
7.1 Errors
Error Message Description Solution NoSensor Found... No sensor connected Connect a sensor Fail NoSensor No sensor connected Connect a sensor Fail NotMatch Sensor version mismatch–the sensor version and part number do not match the configuration being exported Use a different sensor or select a different export configuration Fail TryAgain Import or export failure Try the import/export again RSD1 Remote Display
8 Contact Us
Address: Banner Engineering Corporate
9714 Tenth Avenue North
Minneapolis, Minnesota 55441, USA Phone: +1 763 544 3164 Website: www.bannerengineering.com Europe Address: Banner Engineering EMEA Park Lane, Culliganlaan 2F, bus 3
1831 Diegem, Belgium
Phone: +32 (0)2 456 0780 Website: www.bannerengineering.com Email: mail@bannerengineering.com Turkey Address: Şerifali Mah. Münevver Sok. Ekomed Plaza No:10 Kat:4 Ümraniye / İstanbul, Türkiye Phone: +90 216 688 8282 Website: www.bannerengineering.com Email: turkey@bannerengineering.com.tr India Address: Banner Engineering India Pune Head Quarters Office No. 1001, 10th Floor Sai Capital, Opp. ICC Senapati Bapat Road Pune 411016, India Phone: +91 (0) 206 640 5624 Website: www.bannerengineering.com Email: salesindia@bannerengineering.com Mexico Address: Banner Engineering de Mexico Monterrey Head Office San Pedro Garza Garcia, Nuevo Leon, Mexico Phone: +52 81 8363 2714 or 01 800 BANNERE (toll free) Website: www.bannerengineering.com Email: mexico@bannerengineering.com Brazil Address: Banner do Brasil Rua Barão de Teffé nº 1000, sala 54 Campos Elíseos, Jundiaí - SP, CEP.: 13208-761, Brasil Phone: +55 11 2709 9880 Website: www.bannerengineering.com Email: brasil@bannerengineering.com China Address: Banner Engineering Shanghai Rep Office Xinlian Scientific Research Building Level 12, Building 2
1535 Hongmei Road, Shanghai 200233, China
Phone: +86 212 422 6888 Website: www.bannerengineering.com Email: sensors@bannerengineering.com.cn Japan Address: Banner Engineering Japan Cent-Urban Building 305 3-23-15 Nishi-Nakajima Yodogawa-Ku Osaka 532-0011, Japan Phone: +81 (0)6 6309 0411 Website: www.bannerengineering.com Email: mail@bannerengineering.co.jp RSD1 Remote Display
Address: Banner Engineering Taiwan 8F-2, No. 308 Section 1, Neihu Road Taipei 114, Taiwan Phone: +886 (0)2 8751 9966 Website: www.bannerengineering.com Email: info@bannerengineering.com.tw RSD1 Remote Display
9 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. RSD1 Remote Display