SETUP, RISE TIME EFFICIENCY (Typ.)INPUT INRUSH CURRENT (Typ.) SAFETY STANDARDS WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSIONOTHERS NOTE PACKING OVERLOAD OVER VOLTAGE DC CURRENT (Typ.) 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed Compliance to EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B -40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 no derating with external base plate, TX class compliance℃℃ ℃ 5 ~ 95% RH non-condensing -40 ~ +85 , 5 ~ 95% RH non-condensing℃ 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373 218.2K hrs min. MIL-HDBK-217F (25 )℃ 191*86*40mm (L*W*H) 0.94Kg; 12pcs/12.3Kg/0.73CUFT File Name:RSD-200-SPEC 2017-08-17 200W Railway Single Output DC-DC Converter ■/c32/c70/c101/c97/c116/c117/c114/c101/c115/c32/c58 RSD-200 series RIPPLE & NOISE (max.) Note.2 VOLTAGE TOLERANCE Note.3 WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃SAFETY & EMC (Note 4) ENVIRONMENT PROTECTION /c49/c46/c32/c65/c108/c108/c32/c112/c97/c114/c97/c109/c101/c116/c101/c114/c115/c32/c78/c79/c84/c32/c115/c112/c101/c99/c105/c97/c108/c108/c121/c32/c109/c101/c110/c116/c105/c111/c110/c101/c100/c32/c97/c114/c101/c32/c109/c101/c97/c115/c117/c114/c101/c100/c32/c97/c116/c32/c50/c52/c44/c52/c56/c44/c49/c49/c48/c86/c68/c67/c32/c105/c110/c112/c117/c116/c44/c32/c114/c97/c116/c101/c100/c32/c108/c111/c97/c100/c32/c97/c110/c100/c32/c50/c53 /c32/c111/c102/c32/c97/c109/c98/c105/c101/c110/c116/c32/c116/c101/c109/c112/c101/c114/c97/c116/c117/c114/c101/c46℃ /c50/c46/c32/c82/c105/c112/c112/c108/c101/c32/c38/c32/c110/c111/c105/c115/c101/c32/c97/c114/c101/c32/c109/c101/c97/c115/c117/c114/c101/c100/c32/c97/c116/c32/c50/c48/c77/c72/c122/c32/c111/c102/c32/c98/c97/c110/c100/c119/c105/c100/c116/c104/c32/c98/c121/c32/c117/c115/c105/c110/c103/c32/c97/c32/c49/c50/c34/c32/c116/c119/c105/c115/c116/c101/c100/c32/c112/c97/c105/c114/c45/c119/c105/c114/c101/c32/c116/c101/c114/c109/c105/c110/c97/c116/c101/c100/c32/c119/c105/c116/c104/c32/c97/c32/c48/c46/c49/c117/c102/c32/c38/c32/c52/c55/c117/c102/c32/c112/c97/c114/c97/c108/c108/c101/c108/c32/c99/c97/c112/c97/c99/c105/c116/c111/c114/c46 /c51/c46/c32/c84/c111/c108/c101/c114/c97/c110/c99/c101/c32/c58/c32/c105/c110/c99/c108/c117/c100/c101/c115/c32/c115/c101/c116/c32/c117/c112/c32/c116/c111/c108/c101/c114/c97/c110/c99/c101/c44/c32/c108/c105/c110/c101/c32/c114/c101/c103/c117/c108/c97/c116/c105/c111/c110/c32/c97/c110/c100/c32/c108/c111/c97/c100/c32/c114/c101/c103/c117/c108/c97/c116/c105/c111/c110/c46 /c52/c46/c32 /c32/c84/c104/c101/c32/c112/c111/c119/c101/c114/c32/c115/c117/c112/c112/c108/c121/c32/c105/c115/c32/c99/c111/c110/c115/c105/c100/c101/c114/c101/c100/c32/c97/c32/c99/c111/c109/c112/c111/c110/c101/c110/c116/c32/c119/c104/c105/c99/c104/c32/c119/c105/c108/c108/c32/c98/c101/c32/c105/c110/c115/c116/c97/c108/c108/c101/c100/c32/c105/c110/c116/c111/c32/c97/c32/c102/c105/c110/c97/c108/c32/c101/c113/c117/c105/c112/c109/c101/c110/c116/c46/c32/c65/c108/c108/c32/c116/c104/c101/c32/c69/c77/c67/c32/c116/c101/c115/c116/c115/c32/c97/c114/c101/c32/c98/c101/c101/c110/c32/c101/c120/c101/c99/c117/c116/c101/c100/c32/c98/c121/c32/c109/c111/c117/c110/c116/c105/c110/c103/c32/c116/c104/c101/c32/c117/c110/c105/c116/c32/c111/c110/c32 /c32/c32/c97/c32 /c109/c109/c42 /c109/c109/c32/c109/c101/c116/c97/c108/c32/c112/c108/c97/c116/c101/c32/c119/c105/c116/c104/c32/c49/c109/c109/c32/c111/c102/c32/c116/c104/c105/c99/c107/c110/c101/c115/c115/c46/c32/c84/c104/c101/c32/c102/c105/c110/c97/c108/c32/c101/c113/c117/c105/c112/c109/c101/c110/c116/c32/c109/c117/c115/c116/c32/c98/c101/c32/c114/c101/c45/c99/c111/c110/c102/c105/c114/c109/c101/c100/c32/c116/c104/c97/c116/c32/c105/c116/c32/c115/c116/c105/c108/c108/c32/c109/c101/c101/c116/c115/c32/c69/c77/c67/c32/c100/c105/c114/c101/c99/c116/c105/c118/c101/c115/c46/c51/c54/c48 /c51/c54/c48 /c32/c70/c111/c114/c32/c103/c117/c105/c100/c97/c110/c99/c101/c32/c111/c110/c32/c104/c111/c119/c32/c116/c111/c32 /c32/c32/c32/c32/c112/c101/c114/c102/c111/c114/c109/c32/c116/c104/c101/c115/c101/c32/c69/c77/c67/c32/c116/c101/c115/c116/c115/c44/c32/c112/c108/c101/c97/c115/c101/c32/c114/c101/c102/c101/c114/c32/c116/c111/c32/c147/c69/c77/c73/c32/c116/c101/c115/c116/c105/c110/c103/c32/c111/c102/c32/c99/c111/c109/c112/c111/c110/c101/c110/c116/c32/c112/c111/c119/c101/c114/c32/c115/c117/c112/c112/c108/c105/c101/c115/c46/c148/c32/c40/c97/c115/c32/c97/c118/c97/c105/c108/c97/c98/c108/c101/c32/c111/c110/c32/c104/c116/c116/c112/c58/c47/c47/c119/c119/c119/c46/c109/c101/c97/c110/c119/c101/c108/c108/c46/c99/c111/c109/c41 /c53/c46/c32/c83/c116/c114/c111/c110/c103/c108/c121/c32/c114/c101/c99/c111/c109/c109/c101/c110/c100/c101/c100/c32/c116/c104/c97/c116/c32/c101/c120/c116/c101/c114/c110/c97/c108/c32/c111/c117/c116/c112/c117/c116/c32/c99/c97/c112/c97/c99/c105/c116/c97/c110/c99/c101/c32/c115/c104/c111/c117/c108/c100/c32/c110/c111/c116/c32/c101/c120/c99/c101/c101/c100/c32/c53/c48/c48/c48/c117/c70/c46/c32 /c58(/c79/c110/c108/c121/c32/c102/c111/c114/c32/c82/c83/c68/c45/c50/c48/c48/c45/c49/c50/c41 12V 24V 12V 24V 12V 24V 120mVp-p 150mVp-p 120mVp-p 150mVp-p 120mVp-p 150mVp-p 800ms, 50ms at full load 9.6A/24V 9.6A/24V 45A/48VDC 4.8A/48V 4.8A/48V 45A/110VDC 2.1A/110V 2.1A/110V 45A/24VDC /UNI2027/c67/c111/c109/c112/c108/c105/c97/c110/c99/c101/c32/c116/c111/c32/c69/c78/c53/c48/c49/c53/c53/c32/c97/c110/c100/c32/c69/c78/c52/c53/c53/c52/c53/c45/c50/c32/c114/c97/c105/c108/c119/c97/c121/c32/c115/c116/c97/c110/c100/c97/c114/c100 /UNI2027/c50/c58/c49/c32/c119/c105/c100/c101/c32/c105/c110/c112/c117/c116/c32/c114/c97/c110/c103/c101 /UNI2027/c80/c114/c111/c116/c101/c99/c116/c105/c111/c110/c115/c58/c32/c83/c104/c111/c114/c116/c32/c99/c105/c114/c99/c117/c105/c116/c32/c47/c32/c79/c118/c101/c114/c108/c111/c97/c100/c32/c47/c32/c79/c118/c101/c114/c32/c118/c111/c108/c116/c97/c103/c101/c32/c47/c32/c79/c118/c101/c114/c32/c116/c101/c109/c112/c101/c114/c97/c116/c117/c114/c101/c32 /c32/c32/c32/c32/c32/c47/c32/c73/c110/c112/c117/c116/c32/c114/c101/c118/c101/c114/c115/c101/c32/c112/c111/c108/c97/c114/c105/c116/c121 /UNI2027/c52/c48/c48/c48/c86/c68/c67/c32/c73/c47/c79/c32/c105/c115/c111/c108/c97/c116/c105/c111/c110/c32 /UNI2027/c67/c111/c111/c108/c105/c110/c103/c32/c98/c121/c32/c102/c114/c101/c101/c32/c97/c105/c114/c32/c99/c111/c110/c118/c101/c99/c116/c105/c111/c110 /UNI2027/c72/c97/c108/c102/c32/c101/c110/c99/c97/c112/c115/c117/c108/c97/c116/c101/c100 /UNI2027/c66/c117/c105/c108/c116/c45/c105/c110/c32/c99/c111/c110/c115/c116/c97/c110/c116/c32/c99/c117/c114/c114/c101/c110/c116/c32/c108/c105/c109/c105/c116/c105/c110/c103/c32/c99/c105/c114/c99/c117/c105/c116 /UNI2027/c49/c85/c32/c108/c111/c119/c32/c112/c114/c111/c102/c105/c108/c101/c32/c52/c48/c109/c109 /UNI2027/c65/c108/c108/c32/c117/c115/c105/c110/c103/c32/c49/c48/c53 /c32/c108/c111/c110/c103/c32/c108/c105/c102/c101/c32/c101/c108/c101/c99/c116/c114/c111/c108/c121/c116/c105/c99/c32/c99/c97/c112/c97/c99/c105/c116/c111/c114/c115℃ /UNI2027/c76/c69/c68/c32/c105/c110/c100/c105/c99/c97/c116/c111/c114/c32/c102/c111/c114/c32/c112/c111/c119/c101/c114/c32/c111/c110 /UNI2027/c49/c48/c48/c37/c32/c102/c117/c108/c108/c32/c108/c111/c97/c100/c32/c98/c117/c114/c110/c45/c105/c110/c32/c116/c101/c115/c116 /UNI2027/c51/c32/c121/c101/c97/c114/c115/c32/c119/c97/c114/c114/c97/c110/c116/c121 OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down 48V 48V 48V 4.2A 4.2A 4.2A 0 ~ 4.2A 0 ~ 4.2A 0 ~ 4.2A 201.6W 201.6W 201.6W 180mVp-p 180mVp-p 180mVp-p ±2.0% ±2.0% ±2.0% ±0.5% ±0.5% ±0.5% ±1.0% ±1.0% ±1.0% 89% 9.6A/24V 91% 91% 4.8A/48V 2.1A/110V HOLD UP TIME (Typ.) B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load ; D-type comply with S2 level @ full load EMC IMMUNITY EMC EMISSION VOLTAGE RANGE 16.8 ~ 31.2VDC 14.4 ~ 33.6VDC 33.6 ~ 62.4VDC 28.8 ~ 67.2VDC 67.2 ~ 143VDC 57.6 ~ 154VDC CONTINUOUS 1 SEC. IEC60950-1(LVD) Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A RAILWAY STANDARD EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC ; EN45545-2 for fire protection RSD-200B-24RSD-200B-12 RSD-200C-24 RSD-200C-12 RSD-200D-24RSD-200D-12RSD-200B-48 RSD-200C-48 RSD-200D-48 Protection type : Shut down o/p voltage, re-power on to recover
Mechanical Specification Case No.203A Unit:mm fosc : 130KHzBlock Diagram CIRCUIT DETECTIONO.L.P. O.T.P. O.V.P. EMI FILTER POWER SWITCHING FILTER RECTIFIERS +V -VI/P FG CONTROL PWM FG Input Terminal Pin No. Assignment : Output Terminal Pin No. Assignment : Pin No. Pin No. 1 1 2 2 Assignment Assignment DC INPUT V+ DC OUTPUT -V DC INPUT V- DC OUTPUT +V Input Fuse There are one or two fuses connected in series to the positive input line, which are used to protect against abnormal surge. Fu se specifications of each model are shown as below. Type B C D Fuse Type Time-Lag Time-Lag Time-Lag Reference and Rating 2*Conquer UDA-A, 10A, 250V Conquer UDA-A, 10A, 250V Conquer UDA-A, 5A, 250V 200W Railway Single Output DC-DC Converter RSD-200 series File Name:RSD-200-SPEC 2017-08-17 9.5 8.2 I/P 4-R2.1 LED 4183 191 7213 2-R2.1 28 O/P 4183 15max.10max.
14.013.1 12 13 14 15 16 17 Turn On Turn Off 57.354.1 50 55 60 65 70 Turn On Turn Off 27.925.9 25 27 29 31 33 35 Turn On Turn Off 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms Input Reverse Polarity Protection Input Range and Transient Ability Input Under-Voltage Protection Inrush Current There is a MOSFET connected in series to the negative input line. If the input polarity is connected reversely, the MOSFET opens and there will be no output to protect the unit. The series has a wide range input capability. Within 30% of rated input voltage, it can be executed at full-load operation and o perate properly; with 40% of rated input± ± voltage, it can withstand that for 1 second. If input voltage drops below Vimin, the internal control IC shuts down and there is no output voltage. It recovers automaticall y when input voltage reaches above Vimin, please refer to the cruve below. Inrush current is suppressed by a resistor during the initial start-up, and then the resistor is bypassed by a MOSFET to reduce power consumption after accomplishing the start-up. TIME TIME TIME TIME TIME TIME LOAD LOAD LOAD LOAD LOAD LOAD Vin Vin Vin Vo Vo Vo 200W Railway Single Output DC-DC Converter RSD-200 series File Name:RSD-200-SPEC 2017-08-17 Hold-up Time Output Voltage Adjustment D type is in compliance with S2 level, while B and C types are in compliance with S1 level at full load output condition. To ful fil the requirements of S2 level, B and C This function is optional, which the standard product does not have it. If you do need the function, please contact MW for deta ils. types require de-rating their output load to 70%, please refer to the curve diagrams below. RSD-200B-12 RSD-200B-24 RSD-200C-12 RSD-200B-24 RSD-200C-24 RSD-200C-24 RSD-200B-48 RSD-200D-24 RSD-200C-48
70% 75% 80% 85% 90% 95% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 143Vdc 110Vdc 67.2Vdc 70% 75% 80% 85% 90% 95% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 143Vdc 110Vdc 67.2Vdc 70% 75% 80% 85% 90% 95% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 143Vdc 110Vdc 67.2Vdc 55% 60% 65% 70% 75% 80% 85% 90% 95% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 62.4Vdc 48Vdc 33.6Vdc 70% 75% 80% 85% 90% 95% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 62.4Vdc 48Vdc 33.6Vdc 70% 75% 80% 85% 90% 95% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 62.4Vdc 48Vdc 33.6Vdc 70% 75% 80% 85% 90% 95% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 31.2Vdc 24Vdc 16.8Vdc 70% 75% 80% 85% 90% 95% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 31.2Vdc 24Vdc 16.8Vdc RSD-200B-12 RSD-200C-12 RSD-200D-12 RSD-200B-24 RSD-200C-24 RSD-200D-24 RSD-200B-48 RSD-200C-48 RSD-200D-48 70% 75% 80% 85% 90% 95% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 31.2Vdc 24Vdc 16.8VdcEFFICIENCY EFFICIENCY EFFICIENCY EFFICIENCY EFFICIENCY EFFICIENCY EFFICIENCY EFFICIENCY EFFICIENCY LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD Efficiency vs Load & Vin Curve The efficiency vs load & Vin curves of each model are shown as below. 200W Railway Single Output DC-DC Converter RSD-200 series File Name:RSD-200-SPEC 2017-08-17 Parallel and Series Connection A.Operation in Parallel Since RSD-200 series don't have built-in parallel circuit, it can only use external circuits to achieve the redundant operation but not increase the current rating. 1.Add a diode at the positive-output of each power supply (as shown as below), the current rating of the diode should be larger than the maximum output current rating and attached to a suitable heat sink. This is only for redundant use (increase the reliability of the system) and users have to check suitability of the circuit by themselves. I/P I/P PS2 INE PS1 I/P I/P RLD1 B.Operation in Series RSD-200 can be operated in series. Here are the methods of doing it: 1.Positive and negative terminals are connected as shown as below. According to the connection, you can get the positive and neg ative output voltages for your loads. supplier if you have this kind of application. -V-I/P I/P I/P PS2 I/P E IN PS1 RL RL COM
Over Temperature Protection LED Indicator The converter shuts off to protect itself when the output voltage drawn exceeds 115~135% of its output rating. It must be repow ered on to recover. The converter shuts off to protect itself when the built-in temperature sensor mounted on the main power transformer senses a h igh temperature. The output recovers Equipped with a built-in LED indicator, the converter provides an easy way for users to check its condition through the LED ind icator. Green : normal operation; No signal: no power or failure. automatically if the temperature drops below the limit. 2.Increase the output voltage (current does not change). Because RSD-200 series have no reverse blocking diode in the unit, you should add an external blocking diode to prevent the damage of every unit while starting up. The voltage rating of the external diode should be larger than V1+V2 (as shown as below). -I/P +I/P PS2 2V I/P - E IN PS1 I/P V D 2 V1+V2 LR Overload Protection If the output draw up to 105~135% of its output power rating, the converter will go into overload protection which is constant current mode. After the faulty condition is removed, it will recover automatically. Please refer to the diagram below for the detail operation characteristic. Please no te that it's not suitable to operate within the overload region continuously, or it may cause to over temperature and reduce the life of the power supply unit or even dama ge it. 0 50 100 150 100 Vo(%) Io(%) Derating Curve AMBIENT TEMPERATURE ( )℃ LOAD (%) 100 100 -40 20 30 40 50 55 60 70 (HORIZONTAL) Overload region 200W Railway Single Output DC-DC Converter RSD-200 series File Name:RSD-200-SPEC 2017-08-17 a.Single unit operation de-rating output current when ambient temperature is between 55-70 , please refer to the de-rating curve as below.℃ If the unit has no iron plate mounted on its bottom, the maximum ambient temperature for the unit will be 55 as operating under full load condition. It requires℃
AMBIENT TEMPERATURE ( )℃ LOAD (%) 100 100 -40 20 30 40 50 60 70 (HORIZONTAL) b.Operate with additional iron plate the bottom. The size of the suggested iron plate is shown as below. In order for optimal thermal performance, the iron plate mus t have an even & smooth surface and RSD-200 series must be firmly mounted at the center of the iron plate. If it is necessary to fulfil the requirements of EN50155 TX level that operate the unit fully-loaded at 70 , RSD-200 series must be installed onto an iron plate on℃ Suitable installation methods are shown as below. Since RSD-200 is a semi-potted model, its thermal performances for the follow ing installation methods are similar and share the same derating curve. The load vs ambient temperature curve is shown as below. Unit:mm M4*4 360 360 iron plate 200W Railway Single Output DC-DC Converter RSD-200 series File Name:RSD-200-SPEC 2017-08-17 Suitable installation methods are shown as below. Since RSD-200 is a semi-potted model, its thermal performances for the follow ing installation methods are similar and share the same derating curve.
200W Railway Single Output DC-DC Converter RSD-200 series File Name:RSD-200-SPEC 2017-08-17 Immunity to Environmental Conditions Test method Cooling Test Dry Heat Test Damp Heat Test, Cyclic Vibration Test Increased Vibration Test Shock Test Low Temperature Storage Test Salt Mist Test Standard EN 50155 section 12.2.3 (Column 2, Class TX) EN 60068-2-1 Temperature: -40 ℃ Dwell Time: 2 hrs/cycle Temperature: 25 ~55℃℃ Humidity: 90%~100% RH Duration: 48 hrs Temperature: 19 ℃ Humidity: 65% Duration: 10 mins Temperature: 19 ℃ Humidity: 65% Duration: 5 hrs Temperature: 21 3±℃ Humidity: 65 5%± Duration: 30ms*18 Temperature: -40 ℃ Dwell Time: 16 hrs Temperature: 35 2℃± ℃ Duration: 96 hrs Temperature: 70 / 85℃ ℃ Duration: 6 hrs / 10min EN 50155 section 12.2.5 EN 60068-2-30 EN 50155 section 12.2.11 EN 61373 EN 50155 section 12.2.11 EN 61373 EN 50155 section 12.2.11 EN 61373 EN 50155 section 12.2.3 (Column 2, Class TX) EN 60068-2-1 EN 50155 section 12.2.10 (Class ST4) EN 50155 section 12.2.4 (Column 2, Class TX) EN 50155 section 12.2.4 (Column 3, Class TX & Column 4, Class TX) EN 60068-2-2 Test conditions Status No damage PASS PASS PASS PASS PASS PASS PASS EN45545-2 Fire Test Conditions Items Test Items R22 R24 R25 R26 Oxygen index test Smoke density test Smoke toxicity test Oxygen index test Glow-wire test Vertical flame test Standard EN 45545-2:2013 EN ISO 4589-2:1996 EN 45545-2:2013 EN ISO 5659-2:2006 EN 45545-2:2013 NF X70-100:2006 EN 45545-2:2013 EN ISO 4589-2:1996 EN 45545-2:2013 EN 60695-2-11:2000 EN 45545-2:2013 EN 60695-11:2003 Hazard Level PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS HL1 HL2 HL3