Condor D.C. Power Supplies, Inc./A subsidiary of SL Industries, Inc. 2311 Statham Parkway, Oxnard, CA 93033 • 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com/ SPECIFICATIONS: AC Input 90-132 and 180-264Vac, 50/60Hz single phase. Input Current 9/4.5A. Hold-Up Time 20mSec minimum from loss of AC input at full load, nominal line (115Vac). Output Power 350W with cover fan option (390W peak). Overload Protection Standard on all outputs; revovery automatic. Overvoltage Protection Standard on all outputs within ranges below: OUTPUT OVP SETTING V ADJ. RANGE 12V & 15V 18-22V 11.5-15.3V 24V & 28V 29-35V 22.0-30.0V Efficiency 74% minimum at full load; nominal input voltage. Turn-on Time Less than 1 second. Input Protection Internal AC fuse provided. Designed to blow only if a catastrophic failure occurs in the unit—fuse does not blow on overload or short circuit. Inrush Current 60A maximum. Temperature Coefficient 0.03%/ºC typical on all units. Environmental Designed for 0 to 50 °C operation at full rated output power; derate output current and total output power by 2.5% per °C above 50°C. See Environmental and Packaging Specifications (p. 11) for additional information. Power Fail A TTL signal goes low upon failure, 6mS min. before output drops 5%. Output Noise 0.5% RMS, 1% Pk-Pk, measured directly across output terminals. Transient Response Main output—500 µSec typical response time for return to within 0.5% of final value for a 50% load step change. Δ i/Δt<0.2A/µSec. Maximum voltage deviation is 3.5%. Remote Sense Standard on main output; will compensate for 0.5V of cabling losses. Voltage Adjustment Built-in potentiometers adjust outputs minimum of ±5%. Reverse Voltage Protection All outputs protected against inadvertent application of reverse voltage up to 1 times rated current of the reversed output. Leakage Current 100µA. EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements: EMI SPECIFICATIONS COMPLIANCE LEVEL Conducted Emissions EN55022 Class B; FCC Class B Static Discharge EN61000-4-2, 6 kV contact, 3 kV air RF Field Susceptibility EN61000-4-3, 3 V/meter Fast Transients/Bursts EN61000-4-4, 2 kV , 5 kHz Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Safety Approved to UL1950 (no D3 deviations), CSA22.2 No. 234L6, IEC950 and EN60950. Vibration Designed to meet requirements of MIL-STD 810E, Method 514.4 Category 1. This test consists of random vibration at 0.015g/Hz from 5 to 50Hz declining linearly to 0.15g2/Hz in each axis for one hour. Shock Designed to meet MIL-STD 810E, Method 516.4. Unpackaged units shall meet the bench handling requirements of Procedure VI for four drops per face. FEATURES:

  • Automatic line range selection
  • Fully regulated and floating outputs
  • Modular output configurations
  • FCC, CISPR22 Class B
  • "Smart Load" feature eliminates minimum load requirements
  • For medical version, see p. 116
  • 2-year warranty RSC350 RAINBOW SERIES SWITCHERS marked to LVD RAINBOW SERIES SWITCHERS

Condor D.C. Power Supplies, Inc./A subsidiary of SL Industries, Inc. 2311 Statham Parkway, Oxnard, CA 93033 • 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com/ RSC350 MECHANICAL SPECIFICATIONS: Output configurations: "A" auxiliary output adjusts from 4.7 to 5.3Vdc—available on Aux 2 only. "B" auxiliary output adjusts from 11.5 to 15.5Vdc. "C" same as "B" but factory set at 15Vdc. "D" auxiliary output adjusts from 23 to 29Vdc—available on Aux 1 & 3. RAINBOW SERIES SWITCHERS INPUT: TB1 TERMINAL BLOCK, #6-32 x 0.375" PIN 1) AC LINE PIN 2) AC NEUTRAL PIN 3) CHASSIS GROUND OUTPUT: TB2 TERMINAL BLOCK, #6-32 x 0.375 OUTPUT: BUSSBAR +V1 +5V @ 40A COMMON +5V RTN SIGNALS: J1 AMP P/N 640456-5 PIN 1) POWER GOOD PIN 2) POWER FAIL PIN 3) INHIBIT HI PIN 4) +SENSE PIN 5) -SENSE PIN 1) AUX #1 (RTN) PIN 2) AUX #1 (+) PIN 3) AUX #2 (RTN) PIN 4) AUX #2 (+) PIN 5) AUX #3 (RTN) PIN 6) AUX #3 (+) OUTPUT VOLTAGE ADJUST.: R39 OUT 1 V. ADJ.(AUX4) R25 OUT 2 V. ADJ.(AUX1) R6 OUT 3 V. ADJ.(AUX2) R6 OUT 4 V. ADJ.(AUX3) R31 POWER FAIL ADJ. FAN CONN: AMP P/N 640456-2 +12V 0-0.5 AMP X.XXX=0.010 [0.25mm] X.XX=0.030 [0.76mm]TOLERANCES: TB1 AUX 2 AUX 3 TB2 R25 V2 ADJR77 T2L N GND +5V COM PF ADJ R31 OPTIONAL FAN V1 ADJ R39 AIR 2.36 SCREW 2PL 8-32 MTG 4PL (THIS SURFACE) 0.120 [3.05mm] MAX. W/ OPTIONAL W/ OPTIONAL COVER R6 R6 PWR LIM. FACTORY SET AUX 1 FAN TYP AUX 4 R39 J1 PIN 1 [59.94mm] 3.65 [92.71mm] 8.500 [215.90mm] 9.50 [241.30mm] 8.000 [203.20mm] [12.70mm] 0.50 0.75 [19.05mm] 0.76 [19.30mm] 3.59 [91.19mm] 2.45 [62.23mm] 2.51 ± 0.05 63.75 ± 1.27mm COVER & FAN (SCREW PENETRATION) 1.500 [38.10mm] 0.50 [12.70mm] (2.45) [62.23mm] 10-32 0.660 [16.76mm] 1.11 [28.19mm] (1.77) [44.96mm] [83.82mm] 3.300 [19.56mm] 0.77 [127.00mm] 5.00 FLOW 0.89 [22.61mm] 4PL (ON BOTTOM) LOCATION ledoM niaM 1xuA 2xuA 3xuA BBB053CSRA 04@V5A 21@V21A 4@V21A 4@V21 BBD053CSRA 04@V5A 6@V42A 4@V21A 4@V21 CAD053CSRA 04@V5A 6@V42A 4@V5A 4@V51 DAB053CSRA 04@V5A 21@V21A 4@V5A 5.2@V42 BAB053CSRA 04@V5A 21@V21A 4@V5A 4@V21 BAB253CSRA 8@V42A 21@V21A 4@V5A 4@V21 DAB253CSRA 8@V42A 21@V21A 4@V5A 5.2@V42 BBB253CSRA 8@V42A 21@V21A 4@V21A 4@V21 CAD253CSRA 8@V42A 6@V42A 4@V5A 4@V51 BBD253CSRA 8@V42A 6@V42A 4@V21A 4@V21