© 2016 Littelfuse Protection Relays & Controls Time Delay Relays Dedicated - Recycle www.littelfuse.com/rs Rev: 1-A-061016 RS SERIES

Description

The RS Series is a solid-state, encapsulated, recycling timer designed for tough industrial environments. It is used by many testing labs as a life cycle tester; by others as a cycle controller. The RS Series has separate DIP switch adjustments for the on delay and the off delay. These make accurate adjustment possible the first time, every time. Time delays of 0.1 seconds to 1023 hours are available in 4 ranges. Operation (Recycling - ON Time First) Upon application of input voltage, the output energizes and the T1 ON time begins. At the end of the ON time, the output de-energizes and the T2 OFF time begins. At the end of the OFF time, the output energizes and the cycle repeats as long as input voltage is applied. Reset: Removing input voltage resets the output and time delays, and returns the sequence to the ON time. Operation (Recycling - OFF Time First) Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the output energizes and the T1 ON time begins. At the end of the ON time, the output de-energizes and the cycle repeats as long as input voltage is applied. Reset: Removing input voltage resets the output and time delays, and returns the sequence to the OFF time. Features & Benefits FEATURES BENEFITS Microcontroller based Repeat Accuracy + / -0.1%, Setting accuracy + / - 2% 1A steady, 10A inrush solid-state output Provides 100 million operations in typical conditions T otally solid state and encapsulated No moving parts to arc and wear out over time and encapsulated to protect against shock, vibration, and humidity ON and OFF time delay settings Independent adjustment provides greater timing flexibility DIP switch adjustment Provides first time setting accuracy Wiring Diagram L1 N/L2 V = Voltage L = Load

Ordering Information

DELAY T1 ON TIME T2 OFF TIME MODEL INPUT VOLTAGE FIRST DELAY T1 ON TIME T2 OFF TIME RS1A11 12VDC On time 0.1 - 102.3s in 0.1s increments 0.1 - 102.3s in 0.1s increments RS4A22 120VAC On time 0.1 - 102.3m in 0.1m increments 0.1 - 102.3m in 0.1m increments RS2B44 24VAC Off time 1 - 1023h in 1h increments 1 - 1023h in 1h increments RS4A24 120VAC On time 0.1 - 102.3m in 0.1m increments 1 - 1023h in 1h increments RS4A11 120VAC On time 0.1 - 102.3s in 0.1s increments 0.1 - 102.3s in 0.1s increments RS4A33 120VAC On time 1 - 1023m in 1m increments 1 - 1023m in 1m increments RS4A12 120VAC On time 0.1 - 102.3s in 0.1s increments 0.1 - 102.3m in 0.1m increments RS4B12 120VAC Off time 0.1 - 102.3s in 0.1s increments 0.1 - 102.3m in 0.1m increments RS4A13 120VAC On time 0.1 - 102.3s in 0.1s increments 1 - 1023m in 1m increments RS6A13 230VAC On time 0.1 - 102.3s in 0.1s increments 1 - 1023m in 1m increments If you don’t find the part you need, call us for a custom product 800-843-8848

© 2016 Littelfuse Protection Relays & Controls Time Delay Relays Dedicated - Recycle www.littelfuse.com/rs Rev: 1-A-061016 RS SERIES Accessories P1023-6 Mounting bracket The 90° orientation of mounting slots makes installation/removal of modules quick and easy. P1015-64 (AWG 14/16) Female Quick Connect These 0.25 in. (6.35 mm) female terminals are constructed with an insulator barrel to provide strain relief. P1015-18 Quick Connect to Screw Adapter Screw adapter terminal designed for use with all modules with 0.25 in. (6.35 mm) male quick connect terminals. C103PM (AL) DIN Rail 35 mm aluminum DIN rail available in a 36 in. (91 .4 cm) length. P1023-20 DIN Rail Adapter Allows module to be mounted on a 35 mm DIN type rail with two #10 screws. Adjustment Switch Operation Adjustment Switch Operation Function Diagrams RECYCLING (ON FIRST) V = Voltage NO = Normally Open Contact NC = Normally Closed Contact TD1, TD2 = Time Delay R = Reset RECYCLE (OFF TIME FIRST) V = Voltage NO = Normally Open Contact NC = Normally Closed Contact TD1, TD2 = Time Delay R = Reset Specifications Time Delay Range* 0.1 - 102.3s in 0.1s increments 0.1 - 102.3m in 0.1m increments 1 - 1023m in 1m increments 1 - 1023h in 1h increments Repeat Accuracy ±0.1% or 20ms, whichever is greater Setting Accuracy ≤ ±2% or 20ms, whichever is greater Reset Time ≤ 150ms Time Delay vs Temp. & Voltage ≤ ± 2% Input Voltage 12, or 24VDC; 24, 120, or 230VAC Tolerance ±20% AC Line Frequency/DC Ripple 50/60 Hz / ≤ ±10% Power Consumption AC ≤ 2VA; DC ≤ 1W Output Type Solid state Maximum Load Current 1A steady state, 10A inrush at 60°C OFF State Leakage Current AC ≅ 5mA @ 230VAC; DC ≅ 1mA Voltage Drop AC ≅ 2.5V @ 1A; DC ≅ 1V @ 1A Protection Circuitry Encapsulated Dielectric Breakdown ≥ 2000V RMS terminals to mounting surface Insulation Resistance ≥ 100 MΩ Polarity DC units are reverse polarity protected Mechanical Mounting Surface mount with one #10 (M5 x 0.8) screw Dimensions H 76.7 mm (3”); W 50.8 mm (2”); D 38.1 mm (1.5”) Termination 0.25 in. (6.35 mm) male quick connect terminals Environmental Operating/Storage Temperature -40° to 75°C / -40° to 85°C Humidity 95% relative, non-condensing Weight ≅ 3.9 oz (111 g) *For CE approved applications, power must be removed from the unit when a switch position is changed. V = Voltage NO = Normally Open Contact NC = Normally Closed Contact TD1, TD2 = Time Delay R = Reset