MW 60W Reliable Triple Output Medical Grade R P T- 6 0 series el “1 st a HL ANSI/AAMI ES60601-1 EN60601-1 EN60950-1 IEC60601-1 = UL60950-1 i Features Hf Applications * 4"x2" compact size * Oral irrigator * Medical safety approved (2 x MOPP) according to * Hemodialysis machine ANSI/AAMI ES60601-1 and IEC/EN60601-1 * Medical computer monitors * Suitable for BF application with appropriate system consideration + Sleep apnea devices * Cooling by free air convection + EMI class B for class I configuration * Extremely low leakage current * Protections: Short circuit / Overload / Over voltage * 3 years warranty I Description RPT-60 is a 60W highly reliable green PCB type medical power supply with a high power density on the 4” by 2” footprint. It accepts 90~264VAC input and offers dual output voltages . RPT-60 is able to be used for Class I (with FG) system design. The extremely low leakage current is less than 150A. In addition, it conforms to international medical regulations (2*MOPP) and EMC EN55011. i Model Encoding RPT-60, A on es ee ‘Output voltage Rated wattage Series name
60W Reliable Triple Output Medical Grade R P T- 6 0 series el SPECIFICATION OUTPUT NUWBER cH [RaTeocurrenT [4a 2A [5A 4A [2k fsa 4A [5A 0A [CURRENTRANGE __(05-44A [04-298 |01~085A |05~44A oureur aonvep[Btnve _[Bimiew [eon 90~264VAC 127 ~370VDC 47-6342 INPUT 1.AAN15VAC_0.7A/230VAC paorecron -20~ +65°C (Refer to "Derating Curve") 20 ~ 90% RH non-condensing CANSA C222 No SOUT -Eon apyoved-TWVENSOO sprred Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP. Conducted emission EN55011 (CISPR11) SAFETY 8 EN60601-1-2 EMC IMMUNITY OTHERS 101.6°50.8*29mm or 4"* 2" "1.14" inch - 1. All parameters NOT specially mentioned are measured at 230V/AC input, rated load and 25°C of ambient temperature. 2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 3. Ripple & noise are measured at 20MHz of bandwith by using a 12" twisted pair-wire terminated with a 0.1 xf & 474 parallel capacitor. 4, Tolerance : includes set up tolerance, line regulation and load regulation. 5. Touch current was measured from primary input to DC output. NOTE 6. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating attitude higher than 2000m(6500K). 7. Length of set up time is measured at cold frst start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. Heat Sink HS1,HS2 can not be shorted. 9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it sil meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” {as available on http:/www.meanwell.com)
60W Reliable Triple Output Medical Grade R P T- 6 0 series ee) SPECIFICATION OUTPUT NUWBER cH [RaTeocurRenT [3A [tA sa fA AA [CURRENTRANGE [05-385 _[01-1A [01-0854 a5 : oureur [RIPPLE & NOISE (max) nate €OnV-p Gini ‘(Nn 90~264VAC 127 ~370VDC 47-6342 INPUT 1.AAN15VAC _0.7A/230VAC pnoTecnon -20 ~ +65°C (Refer to "Derating Curve") 20 ~ 90% RH non-condensing 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes 2000 els Conducted emission EN55011 (CISPR11) SAFETY ewe EN61000-5-3 = EMC IMMUNITY OTHERS DIMENSION _(L'W'H) _| 101.650.8'20mm or 4"*2"¥1.14" inch - 1. All parameters NOT specially mentioned are measured at 230V/AC input, rated load and 25°C of ambient temperature. 2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 3. Ripple & noise are measured at 20MHz of bandwith by using a 12" twisted pair-wire terminated with a 0.1 xf & 474 parallel capacitor. 4, Tolerance : includes set up tolerance, line regulation and load regulation. 5. Touch current was measured from primary input to DC output. NOTE 6. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating attitude higher than 2000m(6500K). 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. Heat Sink HS1,HS2 can not be shorted. 9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a.360mm"360mm metal plate with 1mm of thickness. The final equipment must be re-confirmied that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” {as available on http:/www.meanwell.com)
MEAN WELL] 60W Reliable Triple Output Medical Grade R P T- 6 0 series el @ Block Diagram C | RecTiFieRs fosc: 100KHz & vs FILTER C ) RECTIFIERS t @ we FILTER EMI RECTIFIERS POWER | 2 C [RECTIFIERS . wt wo pureR ff SWITCHING T= =) gig ©» 9 com OLP | contro. | syye—f owe @ Derating Curve 100 ft) ' —>) ee panne nnn nnn nena nnn n nnn nnn nny = 1 = «0 ' o ' és i ro} 1 iar) ' 20 0 10 20 30 40 50 60 65 70 (HORIZONTAL) AMBIENT TEMPERATURE (‘C)
1 Output Derating VS Input Voltage
+ 0 9 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz
60W Reliable Triple Output Medical Grade R P T- 6 0 series
1 Mechanical Specification
101.6 Unit:mm
fa 95.25 3.175 ie ] Qo) + = iP c 1 gM 2 NS | ! a| = 4 3 oo A oe LOR 4-033 Side View AC Input Connector (CN1) : JST B3P-VH or equivalent PinNo. | Assignment | Mating Housing Terminal \\ ACIN JST VHR | JST SVH-21T-P1.1 2 |_NoPin | or equivalent or equivalent :
3 ACI/L
DC Output Connector (CN2) : JST B6P-VH or equivalent [ PinNo. | Assignment | Mating Housing Terminal 34 JSTVHR JST SVH-217-P1.1 5 or equivalent or equivalent + : Grounding Required A\\, 1.H81,H82 cannot be shorted. 2.M1 is safety ground. For better EMC performance, Please secure an electrical connection between M1,M2 and chassis grounding. ft Installation Manual Please refer to :http://www.meanwell.com/manual.html