65W Single Output Medical Type RPS-65 series /c45/c51/c46/c51/c82/c80/c83 /c54/c53 /c79/c117/c116/c112/c117/c116/c32/c119/c97/c116/c116/c97/c103/c101 /c79/c117/c116/c112/c117/c116/c32/c118/c111/c108/c116/c97/c103/c101 /c69/c78/c32/c54/c48/c54/c48/c49/c45/c49 /c73/c69/c67/c32/c54/c48/c54/c48/c49/c45/c49 /c56 /c45 /c83/c101/c114/c105/c101/c115/c32/c110/c97/c109/c101 File Name: -SPEC 2015-11-04RPS 65- /c65/c112/c112/c108/c105/c99/c97/c116/c105/c111/c110/c115Features /UNI2027Oral irrigator Hemodialysis machine/UNI2027 Medical monitors/UNI2027 Sleep apnea devices/UNI2027
Description
/c32/c32/c32/c32/c77/c111/c100/c101/c108/c32/c69/c110/c99/c111/c100/c105/c110/c103 /UNI20273"×2" miniature size Universal AC input / Full range/UNI2027 Class (without FG) installations/UNI2027Ⅱ Medical safety approved/UNI2027 (2 x MOPP between primary to secondary) Suitable for BF application with appropriate system consideration/UNI2027 Low leakage current <100 A/UNI2027 μ No load power consumption<0.1W/UNI2027 High efficiency up to 91%/UNI2027 For 1U applications/UNI2027 Protections: Short circuit / Overload / Over voltage/UNI2027 Cooling by free air convection/UNI2027 -30~70 wide range of operating temperature/UNI2027℃ /UNI2027/c79/c112/c101/c114/c97/c116/c105/c110/c103/c32/c97/c108/c116/c105/c116/c117/c100/c101/c32/c117/c112/c32/c116/c111/c32/c52/c48/c48/c48/c32/c109/c101/c116/c101/c114/c115/c40/c78/c111/c116/c101/c32/c54/c46/c41 LED indicator for power on/UNI2027 3 years warranty/UNI2027 RPS-65 is a 65W highly reliable green PCB type medical power supply with a high power density on the 3” by 2” footprint. It accepts 80~264VAC input and offers various output voltages between 3.3V and 48V. The working efficiency is up to 91% and the extremely low no load power consumption is down below 0.1W. RPS-65 is able to be used for Class (no FG) system design. The extremely low leakage current is lessⅡ than 100 A. In addition, it conforms to international medical regulations (2*MOPP) and EMC EN55011,μ perfectly fitting all kinds of BF rated “patient contact” medical system equipment. y
VOLTAGE TOLERANCE Note.3 I/P-O/P: 4KVAC VOLTAGE ADJ.RANGE SPECIFICATION ORDER NO. DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max.) Note.2 OUTPUT VOLTAGE RANGE Note.4 FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INPUT ENVIRONMENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT Note.5 SAFETY STANDARDS SAFETY & EMC (Note. 6) WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSIONOTHERS NOTE PACKING PROTECTION RPS 65 3 3-- . 3.3V 80mVp-p LINE REGULATION LOAD REGULATION ±0.5% ±2.0% 80 ~ 264VAC 47 ~ 63Hz 80% 1.5A / 115VAC 1A / 230VAC WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃ 959.1Khrs min. -30 ~ +70 (Refer to "Derating Curve")℃ 20% ~ 90% RH non-condensing 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes 0.11Kg; 120pcs/14.2Kg/0.97CUFT Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2 medical level, criteria A OVERLOAD OVER VOLTAGE 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 10A 0 ~ 11A 33W Protection type : Shut down o/p voltage, re-power on to recover ANSI/AAMI ES60601-1 TUV EN60601-1 EС60601-1 approved,, I Compliance to EN55011(CISPR11) class B, EN61000-3-2,3 SETUP, RISE TIME HOLD UP TIME (Typ.) 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load 30ms / 230VAC 12ms / 115VAC at full load EMC IMMUNITY EMC EMISSION ISOLATION LEVEL Primary-Secondary: 2xMOPP PEAK LOAD(10sec.) 36 3W. 2.9~3.6V ±2.0% Touch current< 100 A/264VAC RPS 65-- 5 80mVp-p ±0.5% ±2.0% 84% 10A 0 ~ 11A 50W 55W 47 55.~.V ±2.0% RPS 65-- . 75 7.5V 80mVp-p ±0.5% ±2.0% 85% 0 ~ 8.8A 60W 66W 7.12~8.3V ±2.0% RPS 65-- 12 12V 120mVp-p ±0.5% ±2.0% 88% 0 ~ 5.96A 11.4~13.2V ±2.0% RPS 65-- 15 15V 150mVp-p ±0.5% ±1.0% 89% 5.42A 0 ~ 4.77A 13.5~16.5V ±1.0% RPS 65-- 24 24V 240mVp-p ±0.5% ±1.0% 90% 2.71A 0 ~ 2.98A 22.8~27.6V ±1.0% RPS 65-- 48 48V 300mVp-p ±0.5% ±1.0% 91% 1.36A 0 ~ 1.49A 45.6~52.8V ±1.0% 4.34A 65W 71.5W 65.1W 71.6W 65W 71.5W 65.3W 71.5W 65W Single Output Medical Type RPS-65 series СOLD STAR 30A/115VAC 50A/230VAC File Name: -SPEC 2015-11-04RPS 65- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃ 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. Touch current was measured from primary input to DC output. /c84/c104/c101/c32/c97/c109/c98/c105/c101/c110/c116/c32/c116/c101/c109/c112/c101/c114/c97/c116/c117/c114/c101/c32/c100/c101/c114/c97/c116/c105/c110/c103/c32/c111/c102/c32/c53 /c47/c49/c48/c48/c48/c109/c32/c105/c115/c32/c110/c101/c101/c100/c101/c100/c32/c102/c111/c114/c32/c111/c112/c101/c114/c97/c116/c105/c110/c103/c32/c97/c108/c116/c105/c116/c117/c100/c101/c32/c103/c114/c101/c97/c116/c101/c114/c32/c116/c104/c97/c110/c32/c50/c48/c48/c48/c109/c32/c40/c54/c53/c48/c48/c102/c116/c41/c46℃ 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) MIL-HDBK-217(25 )℃
Derating Curve Static Characteristics CIRCUIT DETECTION O.L.P. EMI FILTER RECTIFIER & POWER SWITCHING FILTER RECTIFIERS +V -VI/P CONTROL O.V.P. fosc : 65KHz RECTIFIERS FILTER -30 0 20 10 30 40 100 6050 70 INPUT VOLTAGE (V) 60Hz 80 115100 120 160 140 200 180 240 220 264 LOAD (%) 100 AMBIENT TEMPERATURE ( )℃ LOAD (%) (HORIZONTAL) 65W Single Output Medical Type RPS-65 series Block Diagram File Name: -SPEC 2015-11-04RPS 65-
Mechanical Specification Case No. Unit:mm AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. Assignment AC/N No Pin AC/L Mating Housing JST VHR JST SVH-21T-P1.1 or equivalent or equivalent Terminal DC Output Connector (CN2) : JST B2P-VH or equivalent Pin No. Assignment Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent Installation Manual Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html 65W Single Output Medical Type RPS-65 series LED 3 max. CN1 3.175 3.175 69.85 76.2 50.8 44.45 CN2 FS1 AC FUSE T2A/250V 4- 3.2ψ SVR1HS1 HS100 3- V 4- V File Name: -SPEC 2015-11-04RPS 65-