Description

RPS-30 is a 30W highly reliable green PCB type medical power supply with a high power density on the 3” by 2” footprint. It accepts 80~264VAC input and offers various output voltages between 3.3V and 48V. The working efficiency is up to 92% and the extremely low no load power consumption is down below 0.1W. RPS-30 is able to be used for ClassⅡ(no FG) system design. The extremely low leakage current is less than 80 A. In addition, it conforms to international medical regulations (2*MOPP) and EMC EN55011, perfectly fitting all kinds of BF rated “patient contact” medical system equipment.a ‧Suitable for BF application with appropriate system consideration ‧Cooling by free air convection ‧EMI class B for class Ⅱ configuration ‧No load power consumption<0.1W ‧Extremely low leakage current ‧Protections: Short circuit / Overload / Over voltage 30W Reliable Green Medical Power Supply μ File Name:RPS-30-SPEC 2017-10-23

I/P-O/P: 4KVAC VOLTAGE ADJ.RANGE RPS-30 series SPECIFICATION ORDER NO. DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max.) Note.3 OUTPUT VOLTAGE RANGE Note.5 FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INPUT ENVIRONMENT INRUSH CURRENT (Typ.) LEAKAGE CURRENT(max.) Note.6 SAFETY STANDARDS SAFETY & EMC (Note. 8) WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSION (L*W*H)OTHERS NOTE PACKING PROTECTION RPS-30-3.3 3.3V 80mVp-p LINE REGULATION LOAD REGULATION ±0.5% ±1.0% 80 ~ 264VAC 47 ~ 63Hz 80% 1A / 115VAC 0.5A / 230VAC WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃ 628.7Khrs min. -30 ~ +70 (Refer to "Derating Curve")℃ 20% ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH non-condensing℃ 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes 0.09Kg; 120pcs/11.8Kg/0.97CUFT OVERLOAD OVER VOLTAGE 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 0 ~ 6.6A 19.8W Protection type : Shut down o/p voltage, re-power on to recover SETUP, RISE TIME HOLD UP TIME (Typ.) 200ms, 30ms / 230VAC 200ms, 30ms / 115VAC at full load 30ms / 230VAC 16ms / 115VAC at full load СOLD STAR 30A/115VAC 60A/230VAC ISOLATION LEVEL Primary-Secondary: 2xMOPP 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 f & 47 f parallel capacitor. 4. Tolerance : includes set up tolerance, line regulation and load regulation. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. Touch current was measured from primary input to DC output. 8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) PEAK LOAD(10sec.) Note.2 21.8W 3.1~3.6V ±2.0% Touch current< 80 A/264VAC RPS-30-5 80mVp-p ±0.5% ±1.0% 82% 0 ~ 6.6A 30W 33W 4.7~5.5V ±2.0% RPS-30-7.5 7.5V 80mVp-p ±0.5% ±1.0% 84% 0 ~ 4.4A 30W 33W 7.12~8.3V ±2.0% RPS-30-12 12V 100mVp-p ±0.5% ±1.0% 88% 0 ~ 2.75A 11.4~13.2V ±2.0% RPS-30-15 15V 100mVp-p ±0.5% ±1.0% 89% 2.5A 0 ~ 2.2A 13.5~16.5V ±2.0% RPS-30-24 24V 150mVp-p ±0.5% ±1.0% 89.5% 1.25A 0 ~ 1.375A 22.8~27.6V ±1.0% RPS-30-48 48V 150mVp-p ±0.5% ±1.0% 92% 0.625A 0 ~ 0.687A 45.6~52.8V ±1.0% 30W 33W 30W 33W 30W 33W 30W 33W MIL-HDBK-217(25 )℃ Parameter Parameter ESD Standard Standard EN55011 (CISPR11) EN55011 (CISPR11) EN61000-3-2 EN61000-3-3 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 Test Level / Note Test Level / Note Class B Class B Class A ----- EMC IMMUNITY EMC EMISSION EN60601-1-2 100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods OPERATING ALTITUDE Note.7 4000 meters 30W Reliable Green Medical Power Supply IEC60601-1, TUV EN60601-1, UL ANSI / AAMI ES60601-1 (3.1 version), CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved; Design refer to EN60335-1 μ μ μ File Name:RPS-30-SPEC 2017-10-23 RF field susceptibility EFT bursts Surge susceptibility Conducted susceptibility Magnetic field immunity Voltage dip, interruption Conducted emission Radiated emission Harmonic current Voltage flicker Level 4, 15KV air ; Level 4, 8KV contact Level 4, 2KV/Line-Line Level 4, 30A/m Level 3, 10V Level 3, 2KV Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz )

fosc : 65KHz -30 0 2010 30 40 100 6050 70 AMBIENT TEMPERATURE ( )℃ INPUT VOLTAGE (V) 60Hz 80 115100 120 160140 200180 240220 264 LOAD (%) 100 LOAD (%) (HORIZONTAL) RPS-30 series CIRCUIT DETECTION O.L.P. EMI FILTER RECTIFIER & POWER SWITCHING FILTER RECTIFIERS +V -VI/P CONTROL O.V.P. RECTIFIERS FILTER 30W Reliable Green Medical Power Supply File Name:RPS-30-SPEC 2017-10-23

Mechanical Specification Case No. Unit:mm CN1 3.175 3.175 69.85 76.2 50.8 44.45 FS1 AC FUSE T2A/250V CN2 SVR1 LED HS2 243 max. AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. Assignment AC/N No Pin AC/L Mating Housing JST VHR JST SVH-21T-P1.1 or equivalent or equivalent Terminal DC Output Connector (CN2) : JST B2P-VH or equivalent Pin No. Assignment Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent 4-ψ3.2 Installation Manual Please refer to : http://www.meanwell.com/manual.html 30W Reliable Green Medical Power Supply Top View Side View File Name:RPS-30-SPEC 2017-10-23