PathTrak™ RPM3000 Monitoring Module for PathTrak Return Monitoring System Key Features • Quickly and easily integrates with current PathTrak systems, including HCU400/1500, HSM-1000 and RPM1000/2000 via field-installable firmware and PathTrak server, client and W ebView server software upgrades
- Measures transient noise as short as 1 µs
- Optimized QAM and spectrum analyzer on every port
- 500 kHz to 85 MHz frequency range—compatible with DOCSIS® V3.0
- 50 dB dynamic range
- Wide variety of resolution bandwidth (RBW) and video bandwidth (VBW) filters QAM/QPSK level, MER, and constellation measurements on individual carriers
- Carrier-to-Composite Noise—in-service ingress under the carrier on QPSK or QAM carriers WEBSITE : www.jdsu.com/test The RPM3000 module is an eight-port, high-speed return path quadrature amplitude modulation (QAM) and spectrum analyzer optimized for the QAM and ingress analysis and monitoring functions of the PathTrak Performance Monitoring System. Each of the eight ports is an independent and isolated test port. The RPM3000 module switches automatically between the eight ports and individually measures both QAM and spectrum performance on each. The mea- surement settings and functions of the RPM3000 consist of all typical spectrum analyzer settings such as resolution bandwidth, video bandwidth, dwell time, span, marker control, maximum hold, minimum hold, peak search, and zero span. The RPM3000 provides flexibility to adjust these parameters in monitoring plans, or provide interactive analysis according to individual preferences. Fast Scanning—Catches the Most Transient Noise and Ingress The RPM3000 consists of a single QAM/spectrum analyzer measurement receiver with eight individual input ports that are switched into the receiver. The overall measurement speed across ports is optimized through use of an integral high- speed switch, unique measurement algorithms, digital receiver technology, and dual digital signal processing (DSP) hardware architecture. In addition, the RPM3000 is designed with a detector for measuring very fast transient noise, ingress, and bursty signals. The RPM3000 can reliably detect and measure bursts of noise as short as 1 µs. COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS
Applications
- Scans 50% faster than RPM2000
- Provides DOCSIS-compliant measurements for live troubleshoot- ing and node certification reports
- Provides Web-based access to live and historical measurements on every node
- Offers highly customizable monitoring plans on every node
- Measurements accessible through the JDSU NetComplete Service Assurance Solutions and through third-party or in-house operation support systems (OSS) with open data formats
TOLL FREE : 1 866 228 3762 FAX : +1 317 614 8314 Test & Measurement Regional Sales LA TIN AMERICA TEL : +55 11 5503 3800 FAX : +55 11 5505 1598 ASIA PACIFIC TEL : +852 2892 0990 FAX : +852 2892 0770 EMEA TEL : +49 7121 86 2222 FAX : +49 7121 86 1222 www.jdsu.com/test RPM3000 MODULE Flexible Measurement Plans to Adapt to User Preferences Users have ultimate flexibility in programming the RPM3000 for real- time troubleshooting and monitoring. The measurement parameters of individual ports can vary, which allows the user to program each of the eight ports on a single RPM3000 with a different measurement plan. In addition, within an individual port, the measurement parameters can be varied by frequency allowing different spans of the return spectrum to be scanned with different resolutions, or certain spans of the spectrum to be skipped altogether. Expands and Scales with No Degradation in Performance As part of the PathTrak Performance Monitoring System, the RPM3000 monitoring modules are virtual memory extension (VME)-based cards that mount into a modular headend controller unit (HCU) control chassis (HCU400 or HCU1500). Thus, a monitoring system can be designed to serve the existing number of test points today, and then can be expanded easily by adding additional RPM3000 modules. Furthermore, because each RPM3000 module is an independent QAM and spectrum analyzer receiver, adding modules to accommodate more test points does not adversely affect the overall system speed or performance. Specifications (Preliminary) Frequency range 500 kHz to 85 MHz Total measurement range –50 to 60 dBmV Operational temperature range & accuracy ±2 dB @ room temperature; ±3 dB drift, 0 to 50°C Spur free dynamic range 50 dB typical with 0 dBmV input 1 Resolution bandwidths Standard: 30, 300, 1000 DOCSIS bandwidths 160, 320, 640, 1280, 2560, and 5120 kHz Video bandwidths Programmable to 10, 30, 100, 300, 1000 kHz Attenuator 0 to 50 dB in 1 dB steps Level accuracy ±2 dB on signal pulses >10µs; ±4 dB on signal pulses >1µs Minimum noise burst measurable <1µs Dwell time Programmable from 1 µs to 100 ms Monitoring mode 250 max points frequency resolution, scan rate depends on measurement settings, typically 8 to 16 scans per second for every port Interactive Spectrum Analyzer mode 500 points frequency resolution, up to 6 full spectrum scans per second with 20µs dwell time Interactive Monitoring View mode Up to 250 points frequency resolution, up to 6 full spectrum scans per second with 20µs dwell time Interactive QAM Analyzer mode 16 QAM and quadrature phase shift keying (QPSK) demodulation, level, message error rate (MER) and constellation, live strip chart over time Recommended input level of active signals 0 to +50 dBmV (over range indicator to prevent invalid measurement results)
Ordering Information
RPM3000F 8-port monitoring module with F connectors RPM3000BNC 8-port monitoring module with BNC connectors Chassis Options HCU400—1010-00-0435 Holds up to 4 RPM cards (can have any combination of RPM1000/2000/3000 cards) HCU1500—1010-00-0433 Holds up to 15 RPM cards (can have any combination of RPM1000/2000/3000 cards) Headend Stealth Modem HSM-1000—1010-00-0427 Enables remote viewing of live spectrum with SDA and DSAM field meters (requires PathTrak Field View Option installed on SDA and/or DSAM field meters) 1Minimum from 5 to 85 MHz with 0 dBmV input is 46 dBc; from 500 kHz to 5 MHz is 45 dBc 16 QAM constellation and CTC. bmp