RMS-25MHW MINI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

Frequency Mixer RMS-25MHW+ Typical Performance Curves Conversion Loss @ IF=30MHz 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 0 347 694 1041 1388 1735 2082 2429 2776 3123 3470 RF Frequency (MHz) Conversion Loss (dB) LO = +10dBm LO = +13dBm LO = +16dBm Conversion Loss vs. IF @ RF=10.1MHz 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 0 367 734 1101 1468 1835 2202 2569 2936 3303 3670 IF Frequency (MHz) Conversion Loss (dB) LO = +13dBm Conversion Loss vs. IF @ RF=2500.1001MHz 7.0 7.2 7.4 7.6 7.8 8.0 8.2 8.4 8.6 8.8 9.0 0 249 498 747 996 1245 1494 1743 1992 2241 2490 IF Frequency (MHz) Conversion Loss (dB) LO = +13dBm IP3 Input 0 347 694 1041 1388 1735 2082 2429 2776 3123 3470 RF Frequency (MHz) IP3 Input (dBm) LO = +10dBm LO = +13dBm LO = +16dBm Compression @ RF IN=+9dBm 0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 0 347 694 1041 1388 1735 2082 2429 2776 3123 3470 RF Frequency (MHz) Compression (dB) LO = +10dBm LO = +13dBm LO = +16dBm Conversion Loss vs. IF @ RF=1250.1MHz 7.0 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 8.0 0 124 248 372 496 620 744 868 992 1116 1240 IF Frequency (MHz) Conversion Loss (dB) LO = +13dBm REV. X2 RMS-25MHW+ 101028 Page 1 of 3

Frequency Mixer RMS-25MHW+ Typical Performance Curves LO-RF Isolation 0 350 700 1050 1400 1750 2100 2450 2800 3150 3500 LO Frequency (MHz) LO-RF Isolation (dB) LO = +10dBm LO = +13dBm LO = +16dBm LO-IF Isolation 0 350 700 1050 1400 1750 2100 2450 2800 3150 3500 LO Frequency (MHz) LO-IF Isolation (dB) LO = +10dBm LO = +13dBm LO = +16dBm RF-IF Isolation 0 347 694 1041 1388 1735 2082 2429 2776 3123 3470 RF Frequency (MHz) RF-IF Isolation (dB) LO = +10dBm LO = +13dBm LO = +16dBm RF VSWR 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 0 347 694 1041 1388 1735 2082 2429 2776 3123 3470 RF Frequency (MHz) RF VSWR LO = +10dBm LO = +13dBm LO = +16dBm IF VSWR 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 0 249 498 747 996 1245 1494 1743 1992 2241 2490 IF Frequency (MHz) IF VSWR LO = +10dBm LO = +13dBm LO = +16dBm LO VSWR 1.0 1.3 1.6 1.9 2.2 2.5 2.8 3.1 3.4 3.7 4.0 110 448 786 1124 1462 1800 2137 2475 2813 3151 3489 LO Frequency (MHz) LO VSWR LO = +10dBm LO = +13dBm LO = +16dBm REV. X2 RMS-25MHW+ 101028 Page 2 of 3

Frequency Mixer RMS-25MHW+ Harmonics Tables (-dBm) 0 - - 2 12 13 25 17 35 27 34 22 44 1 - 40 +0 33 15 37 20 35 25 43 45 35 2 69 62 57 60 53 61 51 59 50 62 52 55 3 >90 72 56 68 58 69 60 65 74 63 64 >77 RF CAL 0 1 2 3 4 5 6 7 8 9 10 (-dBm) 0 - - 12 23 25 36 30 53 40 58 41 53 1 - 33 +0 32 14 38 22 39 27 50 47 47 2 49 40 48 45 42 54 40 53 42 57 53 53 3 87 44 37 44 42 51 61 54 47 49 49 60 4 >90 51 50 54 57 59 57 59 57 69 59 75 5 >90 55 59 73 51 64 50 58 57 57 62 55 6 >90 70 68 74 71 74 79 69 77 74 70 72 7 >90 78 75 80 70 68 76 68 76 73 75 79 8 >90 >87 >87 >87 86 >87 78 >87 77 >87 78 85 9 >90 >87 >87 >87 82 86 81 77 84 77 84 74 10 >90 >87 >87 >87 >87 >87 >87 85 >87 83 >87 82 RF CAL 0 1 2 3 4 5 6 7 8 9 10 Notes: 1. All Harmonics are in (dBc) relative to IF OUTPUT. 2. + entry denotes harmonics are in (dBc) above IF OUTPUT. 3. RF Cal represent the Harmonics level of the RF input signal to the mixer. Test conditions: RF IN: 1250.1 MHz; 4.00 dBm. LO IN: 1280.1 MHz; +13.00 dBm IF OUT: 30 MHz; -3.46 dBm Test conditions: RF IN: 1250.1 MHz; -6.00 dBm. LO IN: 1280.1 MHz; +13.00 dBm IF OUT: 30 MHz; -13.41 dBm LO HARMONICS ORDER (-dBc) (-dBc) RF HARMONICS ORDERRF HARMONICS ORDER REV. X2 RMS-25MHW+ 101028 Page 3 of 3