RMH1C185 BELDEN | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
Product: RMH1C185 RailTuff™ Medium wall single core cable EN 50264-3-1 1800V MM 1 Core 185 mm² Str TC, XLPO Ins, XLPO Jacket Product Description RailTuff™ Medium wall single core cable EN 50264-3-1 1800V MM 1 Core 185 mm² Stranded Tinned Copper, XLPO Insulation, XLPO Sheathed Cable Technical Specifications Product Overview Suitable Applications: For use in electric appliances as well as internal wiring of control panels in rail vehicles as fixed wiring, or wiring where limited flexing in operation is encountered. Typical uses are lighting circuits powered by accumulators, equipment control and monitoring circuit, auxiliary and electric heating circuits. Construction Details Conductor Element No. of Elements Stranding Stranding Class Material Conductor(s) 1 846x0.50 mm Class 5 TC - Tinned Copper Insulation Element Material Nom. Thickness Nom. Insulation Diameter Color Code Conductor(s) XLP, XLPO, XLPE 2.4 mm (0.094 in) 23.6 mm (0.929 in) White XLP, XLPO, XLPE Black Outer Jacket Material Nom. Thickness XLP, XLPO, XLPE 1.2 mm (0.047 in) Overall Cable Diameter (Nominal): 26.5 ± 0.80 mm
Electrical Characteristics
Max. Conductor DCR 0.108 Ohm/km (0.0329 Ohm/1000ft) Table Notes: Dielectric strength on core in water for 1 hour (kVac): 10, D.C. stability at 4.5kVdc in 3% NaCl solution at (85±2)°C for 240h : No breakdown Voltage Voltage Rating Breakdown Voltage 1800/3000V 6.5kVac/5min Mechanical Characteristics Temperature Operating -40°C to +90°C Bend Radius Stationary Min. Installation Min. 133 mm (5.24 in) 106 mm (4.17 in) Bulk Cable Weight: 1936.0 kg/km (1300.9 lbs/1000ft)
Flammability / Reaction to Fire: IEC 60332-1-2, IEC 60332-3-24 ISO/IEC Compliance: IEC 60228, IEC 61034-2 - Smoke Density Min Transmittance = 70 CENELEC Compliance: EN 50264-3-1EN 45545-2 European Halogen Free Standards: IEC 60754-1 - Halogen Amount = HCI+HBr ≤ 0.5%, IEC 60754-2 - Halogen Acid Gas Amount - Max. Conductivity = 10 µS/mm, IEC 60754-2 - Halogen Acid Gas Amount - Min. pH = 4.3 Other Standard Compliance(s): TJ/CL 313 Product Notes Notes: EMEA PN: RMH1C185; History Update and Revision: Revision Number: 0.21 Revision Date: 11-27-2023 © 2024 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.