RM22UA33MT_V01 SCHNEIDER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Jan 13, 2022 Product data sheet Characteristics RM22UA33MT Harmony, Modular 1-phase voltage control relay, 8 A, 2 CO, 15…500 V AC, 380…415 V AC Main Range of Product Harmony Control Relays Product or Component Type Voltage control relay Relay Type Voltage control relay Phase 1 phase Supply circuit type DC Relay name RM22UA Relay monitored parameters Overvoltage or undervoltage detection Undervoltage and overvoltage in window mode Time delay type Adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt Switching capacity in VA 2000 VA Measurement range 15...500 V voltage AC/DC 50/60 Hz Contacts type and composition

2 C/O

Reset time 1500 ms at maximum voltage Maximum switching voltage 250 V AC Minimum switching current 10 mA 5 V DC Maximum switching current 8 A AC [Us] Rated Supply Voltage 380...415 V AC 50/60 Hz Supply voltage limits 323…456.5 V AC Power consumption in VA 8 VA AC Supply voltage frequency 40...70 Hz +/- 10 % Resistance across terminals 150 KOhm E2-M terminals

300 KOhm E1-M terminals

Nominal output current 8 A Hysteresis 3 % fixed full scale for window mode 5…50 % adjustable threshold setting overvoltage or undervoltage detection Run-up delay at power-up 600 ms Maximum measuring cycle 100 ms measurement cycle as true rms value Repeat accuracy +/- 0.5 % input and measurement circuit +/- 2 % time delay Measurement error < 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation Response time <= 500 ms Overvoltage category III IEC 60664-1 Insulation resistance > 100 MOhm 500 V DC IEC 60255-27 Insulation Between supply and measurement Mounting position Any position end end

Housing material Self-extinguishing plastic Status LED Relay ON LED Yellow) Power ON LED Green) Mounting support 35 mm DIN rail conforming to EN/IEC 60715 Electrical durability 100000 cycles Mechanical durability 10000000 cycles Utilisation category AC-15 IEC 60947-5-1 DC-13 IEC 60947-5-1 AC-1 IEC 60947-4-1 DC-1 IEC 60947-4-1 Safety reliability data MTTFd = 308.2 years B10d = 290000 Contacts material Cadmium free Width 0.89 in (22.5 mm) Net Weight 0.24 lb(US) (0.11 kg) Environment Immunity to microbreaks 10 ms Electromagnetic compatibility Immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 Immunity for industrial environments EN/IEC 61000-6-2 Emission standard for industrial environments EN/IEC 61000-6-4 Electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 Electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 Electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 Electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 Surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 Surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 Conducted and radiated emissionsclass B group 1 CISPR 11 Conducted and radiated emissionsclass B CISPR 22 Emission standard for residential, commercial and light-industrial environments except radiated emission) EN/IEC 61000-6-3 Standards EN/IEC 60255-1 Product Certifications RCM GL CCC CSA UL EAC CE Ambient Air Temperature for Storage -40…158 °F (-40…70 °C) Ambient air temperature for operation -4…122 °F (-20…50 °C) 60 Hz Relative humidity 93…97 % 77…131 °F (25…55 °C) IEC 60068-2-30 Vibration resistance 0.075 mm 10…58.1 Hz) not in operation IEC 60068-2-6 1 gn 10…58.1 Hz) not in operation IEC 60068-2-6 0.035 mm 58.1…150 Hz) in operation IEC 60068-2-6 0.5 gn 58.1…150 Hz) in operation IEC 60068-2-6 Shock resistance 15 gn 11 ms) not in operation IEC 60068-2-27 5 gn 11 ms) in operation IEC 60068-2-27 IP degree of protection IP20 IEC 60529 terminals) IP40 IEC 60529 housing) IP50 IEC 60529 front panel) Pollution degree 3 IEC 60664-1 Dielectric test voltage 2.5 kV AC 50 Hz, 1 min IEC 60255-27 Ordering and shipping details Category 22380 - RELAYS-MEASUREMENT (RM17-RM35) Discount Schedule CP2 GTIN 3606480792267 Nbr. of units in pkg. 1 Package weight(Lbs) 4.23 oz (120 g)

Unit Type of Package 1 PCE Package 1 Height 1.02 in (2.6 cm) Package 1 width 3.23 in (8.2 cm) Package 1 Length 3.74 in (9.5 cm) Unit Type of Package 2 S02 Number of Units in Package 2 40 Package 2 Weight 11.45 lb(US) (5.194 kg) Package 2 Height 5.91 in (15 cm) Package 2 width 11.81 in (30 cm) Package 2 Length 15.75 in (40 cm) Unit Type of Package 3 P06 Number of Units in Package 3 640 Package 3 Weight 204.10 lb(US) (92.58 kg) Package 3 Height 19.69 in (50 cm) Package 3 width 31.50 in (80 cm) Package 3 Length 23.62 in (60 cm) Offer Sustainability Sustainable offer status Green Premium product California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov REACh Regulation REACh Declaration EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS Declaration Environmental Disclosure Product Environmental Profile Circularity Profile End Of Life Information WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.

A1,A2 : Supply voltage E1,E2,E3,M : Voltages to be measured 11-14,12 : 1st C/O contact of output relay 21-24,22 : 2nd C/O contact of output relay

Without memory ("No Memory" mode) With memory ("Memory" mode) Overvoltage Control Without memory ("No Memory" mode) With memory ("Memory" mode) Legend Tt Time delay after crossing of threshold Un Nominal supply voltage U Monitored supply voltage H Hysteresis U> Overvoltage threshold U< Undervoltage threshold 11-12/11-14, 21-22/21-24 Output relay connections Relay status: black color = energized. NOTE: In "Memory" mode, the relay opens when crossing of the threshold is detected and then stays in that position. The power supply voltage must be switched off to reset the product.