Harmony, Modular 3-phase voltage control relay,
8 A, 2 CO, 200…240 V AC
Product availability : Stock - Normally stocked in distribution facility Price* : 142.72 USD Main Range of product Harmony Control Relays Product or Component Type 3-phase control relay Relay Type Control relay Phase 3 phase Relay name RM22TR Relay monitored parameters Phase sequence Phase failure detection Overvoltage and undervoltage detection Time delay type Adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt Switching capacity in VA 2000 VA Measurement range 200...240 V voltage AC Contacts type and composition 2 C/O Complementary Reset time 1500 ms at maximum voltage Maximum switching voltage 250 V AC Minimum switching current 10 mA 5 V DC Maximum switching current 8 A AC [Us] Rated Supply Voltage 200...240 V AC Supply voltage limits 160…288 V AC Operating limits - 20 % + 20 % Un Power consumption in VA 10 VA 240 V AC 60 Hz Voltage detection threshold < 100 V AC Supply voltage frequency 50...60 Hz +/- 10 % Output contacts 2 C/O Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications * Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price. Sep 13, 2021
Setting accuracy of the switching threshold +/- 10 % of the full scale Switching threshold drift <= 0.05 % per degree centigrade depending permissible ambient air temperature <= 1 % within the supply voltage range Setting accuracy of time delay 10 P Time delay drift <= 0.05 % per degree centigrade depending permissible ambient air temperature <= 1 % within the supply voltage range Hysteresis 2 % fixed selectable Run-up delay at power-up 650 ms Maximum measuring cycle 150 ms measurement cycle as true rms value Threshold adjustment voltage 2...20 % of Un selected Voltage range 200...240 V phase to phase Repeat accuracy +/- 0.5 % for input and measurement circuit +/- 3 % time delay Measurement error < 1 % over the whole range with voltage variation < 0.05 %/°C with temperature variation Response time <= 300 ms Overvoltage category III conforming to IEC 60664-1 III conforming to UL 508 Insulation resistance > 100 MOhm at 500 V DC conforming to IEC 60255-27 Mounting position Any position Housing material Self-extinguishing plastic Status LED LED (yellow)relay ON LED (green)power ON Mounting support 35 mm DIN rail conforming to EN/IEC 60715 Electrical durability 100000 cycles Mechanical durability 10000000 cycles Utilisation category AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1 Safety reliability data MTTFd = 388.1 years B10d = 350000 Contacts material Cadmium free Width 0.89 in (22.5 mm) Product Weight 0.20 lb(US) (0.09 kg) Environment Immunity to microbreaks 10 ms Electromagnetic compatibility Immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1 Immunity for industrial environments conforming to EN/IEC 61000-6-2 Emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 Emission standard for industrial environments conforming to EN/IEC 61000-6-4 Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4 Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5 Conducted and radiated emissions class B group 1 conforming to CISPR 11 Conducted and radiated emissions class B conforming to CISPR 22
Product Certifications CSA CCC EAC RCM CE GL UL Ambient Air Temperature for Storage -40…158 °F (-40…70 °C) Ambient air temperature for operation -4…122 °F (-20…50 °C) 60 Hz Relative humidity 93…97 % 77…131 °F (25…55 °C) IEC 60068-2-30 Vibration resistance 0.075 mm 10…58.1 Hz) not in operation IEC 60068-2-6 1 gn 10…58.1 Hz) not in operation IEC 60068-2-6 0.035 mm 58.1…150 Hz) in operation IEC 60068-2-6 0.5 gn 58.1…150 Hz) in operation IEC 60068-2-6 Shock resistance 15 gn 11 ms) not in operation IEC 60068-2-27 5 gn 11 ms) in operation IEC 60068-2-27 IP degree of protection IP20 (terminals) conforming to IEC 60529 IP40 IEC 60529 housing) IP50 (front panel) conforming to IEC 60529 Pollution degree 3 conforming to IEC 60664-1 3 conforming to UL 508 Dielectric test voltage 2.5 kV AC 50 Hz, 1 min IEC 60255-27 Ordering and shipping details Category 22380 - RELAYS-MEASUREMENT (RM17-RM35) Discount Schedule CP2 GTIN 3606480792182 Nbr. of units in pkg. 1 Package weight(Lbs) 3.56 oz (101 g) Returnability Yes Country of origin ID Packing Units Unit Type of Package 1 PCE Package 1 Height 3.23 in (8.2 cm) Package 1 width 3.74 in (9.5 cm) Package 1 Length 1.02 in (2.6 cm) Unit Type of Package 2 S02 Number of Units in Package 2 40 Package 2 Weight 9.91 lb(US) (4.495 kg) Package 2 Height 5.91 in (15 cm) Package 2 width 11.81 in (30 cm) Package 2 Length 15.75 in (40 cm) Unit Type of Package 3 PAL Number of Units in Package 3 640 Package 3 Weight 189.99 lb(US) (86.18 kg) Package 3 Height 19.69 in (50 cm) Package 3 width 23.62 in (60 cm) Package 3 Length 31.50 in (80 cm) Offer Sustainability Sustainable offer status Green Premium product California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
REACh Regulation REACh Declaration EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS declaration Environmental Disclosure Product Environmental Profile Circularity Profile End of Life Information
3-Phase Voltage Control Relay Wiring Diagram L1,L2,L3 : Supply to be monitored 11-14,12 : 1st C/O contact of output relay 21-24,22 : 2nd C/O contact of output relay
Phase Failure Detection (U measured < 0.7 x nominal supply voltage) Control of Overvoltage and Undervoltage Legend Un Nominal supply voltage R Output relay Tt Overvoltage and undervoltage threshold delay (adjustable on front panel from 0.3 to 30 s) H Hysteresis U> Overvoltage threshold U< Undervoltage threshold L1, L2, L3 Phases of the supply voltage monitored 11-12, 11-14 R1 output relay connections Relay status: black color = energized.