Harmony, Modular 1-phase current control relay,
8 A, 2 CO, 24…240 V AC/DC
Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 103.27 USD Main Range of product Harmony Control Relays Product or Component Type Current control relay Relay Type Current control relay Relay name RM22JA Relay monitored parameters Overcurrent detection Time delay type Without Switching capacity in VA 2000 VA Measurement range 4...40 mA E1-M terminals 20...200 mA E2-M terminals 100...1000 mA E3-M terminals 4 mA...1 A current AC/DC 50/60 Hz Contacts type and composition 2 C/O Complementary Reset time 1500 ms at maximum voltage Maximum switching voltage 250 V AC Minimum switching current 10 mA 5 V DC Maximum switching current 8 A AC [Us] Rated Supply Voltage 24...240 V AC/DC 50/60 Hz +/- 10 % Supply voltage limits 20.4…264 V AC/DC Operating limits - 15 % + 10 % Un Power consumption in VA 3.5 VA AC Maximum power consumption in W 1.5 W DC Supply voltage frequency 50...60 Hz +/- 10 % Resistance across terminals 2.5 Ohm E1-M terminals
0.5 Ohm E2-M terminals
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications * Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price. Sep 13, 2021
0.1 Ohm E3-M terminals
Nominal output current 8 A Internal input resistance 0.1 Ohm
2.5 Ohm
0.5 Ohm
Setting accuracy of the switching threshold +/- 10 % of the full scale Switching threshold drift <= 0.05 % per degree centigrade depending permissible ambient air temperature <= 1 % within the supply voltage range Setting accuracy of time delay 10 P Time delay drift <= 0.05 % per degree centigrade depending permissible ambient air temperature <= 1 % within the supply voltage range Hysteresis 5…50 % adjustable threshold setting Run-up delay at power-up 0.3 s Maximum measuring cycle 100 ms measurement cycle as true rms value Repeat accuracy +/- 0.5 % for input and measurement circuit +/- 0.2 % time delay Measurement error < 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation Response time <= 500 ms Threshold setting 10...100 % Overvoltage category III conforming to IEC 60664-1 III conforming to UL 508 Insulation resistance > 100 MOhm at 500 V DC conforming to IEC 60255-27 Insulation Between supply and measurement Mounting position Any position Housing material Self-extinguishing plastic Status LED LED (yellow)relay ON LED (green)power ON Mounting support 35 mm DIN rail conforming to EN/IEC 60715 Electrical durability 100000 cycles Mechanical durability 10000000 cycles Utilisation category AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1 Safety reliability data MTTFd = 296.8 years B10d = 270000 Contacts material Cadmium free Width 0.89 in (22.5 mm) Product Weight 0.24 lb(US) (0.11 kg) Environment Immunity to microbreaks 50 ms Electromagnetic compatibility Immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1 Immunity for industrial environments conforming to EN/IEC 61000-6-2 Emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 Emission standard for industrial environments conforming to EN/IEC 61000-6-4 Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4 Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5 Conducted and radiated emissions class B group 1 conforming to CISPR 11 Conducted and radiated emissions class B conforming to CISPR 22 Standards EN/IEC 60255-1 Product Certifications EAC CSA CE RCM CCC UL GL Ambient Air Temperature for Storage -40…158 °F (-40…70 °C) Ambient air temperature for operation -4…122 °F (-20…50 °C) 60 Hz Relative humidity 93…97 % 77…131 °F (25…55 °C) IEC 60068-2-30 Vibration resistance 0.075 mm 10…58.1 Hz) not in operation IEC 60068-2-6 1 gn 10…58.1 Hz) not in operation IEC 60068-2-6 0.035 mm 58.1…150 Hz) in operation IEC 60068-2-6 0.5 gn 58.1…150 Hz) in operation IEC 60068-2-6 Shock resistance 15 gn 11 ms) not in operation IEC 60068-2-27 5 gn 11 ms) in operation IEC 60068-2-27 IP degree of protection IP20 (terminals) conforming to IEC 60529 IP40 IEC 60529 housing) IP50 (front panel) conforming to IEC 60529 Pollution degree 3 conforming to IEC 60664-1 3 conforming to UL 508 Dielectric test voltage 2.5 kV AC 50 Hz, 1 min IEC 60255-27 Ordering and shipping details Category 22380 - RELAYS-MEASUREMENT (RM17-RM35) Discount Schedule CP2 GTIN 3606480792281 Nbr. of units in pkg. 1 Package weight(Lbs) 4.27 oz (121 g) Returnability No Country of origin ID Packing Units Unit Type of Package 1 PCE Package 1 Height 3.23 in (8.2 cm) Package 1 width 3.74 in (9.5 cm) Package 1 Length 1.02 in (2.6 cm) Unit Type of Package 2 S02 Number of Units in Package 2 40 Package 2 Weight 11.67 lb(US) (5.295 kg) Package 2 Height 5.91 in (15 cm) Package 2 width 11.81 in (30 cm) Package 2 Length 15.75 in (40 cm) Unit Type of Package 3 PAL Number of Units in Package 3 640 Package 3 Weight 204.10 lb(US) (92.58 kg) Package 3 Height 19.69 in (50 cm) Package 3 width 23.62 in (60 cm) Package 3 Length 31.50 in (80 cm)
Sustainable offer status Green Premium product California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov REACh Regulation REACh Declaration EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS declaration Environmental Disclosure Product Environmental Profile Circularity Profile End of Life Information WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
A1,A2 : Supply voltage E1,E2,E3,M : Currents to be measured 11-14,12 : 1st C/O contact of output relay 21-24,22 : 2nd C/O contact of output relay
Without memory ("No Memory" mode) With memory ("Memory" mode) Overcurrent Detection Without memory ("No Memory" mode) With memory ("Memory" mode) Legend Ti Starting inhibition time delay Tt Time delay after crossing of threshold Un Supply voltage I Monitored current H Hysteresis I> Overcurrent threshold I< Undercurrent threshold 11-12/11-14, 21-22/21-24 Output relay connections Relay status: black color = energized. NOTE: In "Memory" mode, the relay opens when crossing of the threshold is detected and then stays in that position. The power supply voltage must be switched off to reset the product.