RM17UBE16_V01 SCHNEIDER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Jan 12, 2022 Product data sheet Characteristics RM17UBE16 Harmony, Modular 1-phase voltage control relay, 5 A, 1 CO, 20…80 V AC/DC Main Range of Product Harmony Control Relays Product or Component Type Voltage control relay Relay Type Voltage control relay Product Specific Application For single-phase and DC supply Relay name RM17UBE Relay monitored parameters Self-powered Overvoltage and undervoltage detection Time delay Adjustable 0.1...10 s, 0 + 10 % on crossing the threshold Switching capacity in VA 1250 VA Minimum switching current 10 mA 5 V DC Maximum switching current
5 A AC/DC
0…3.9 VA AC Measurement range 20...80 V voltage AC 50/60 Hz 20...80 V voltage DC Utilisation category AC-12 IEC 60947-5-1 AC-13 IEC 60947-5-1 AC-14 IEC 60947-5-1 AC-15 IEC 60947-5-1 DC-12 IEC 60947-5-1 DC-13 IEC 60947-5-1 DC-14 IEC 60947-5-1 Contacts type and composition
1 C/O
Reset time 1500 ms time delay Maximum switching voltage 250 V AC/DC [Us] Rated Supply Voltage 24...48 V AC/DC 50/60 Hz +/- 10 % Supply voltage limits 15…100 V AC/DC Maximum power consumption in W 1.6 W DC Immunity to microbreaks 20 ms Control circuit frequency 50...60 Hz +/- 10 % Output contacts 1 C/O Nominal output current 5 A Maximum measuring cycle 150 ms measurement cycle as true rms value Hysteresis 3 % fixed threshold setting Delay at power up 1000 Ms DC 500 ms AC Measurement accuracy +/- 10 % of the full scale value Repeat accuracy +/- 0.5 % input and measurement circuit +/- 1 % time delay Measurement error < 1 % over the whole range with voltage variation 0.2 %/°C with temperature variation Polarity Non reversible polarity on DC supply Quality labels CE
Overvoltage category III IEC 60664-1 Insulation resistance > 500 MOhm 500 V DC IEC 60255-5 > 500 MOhm 500 V DC IEC 60664-1 [Ui] rated insulation voltage 250 V IEC 60664-1
400 V IEC 60664-1
Operating position Any position without derating end Housing material Self-extinguishing plastic Local signalling For power ON LED (green) For relay ON LED (yellow) Mounting support 35 mm symmetrical DIN rail conforming to EN/IEC 60715 Electrical durability 100000 cycles Mechanical durability 30000000 cycles Operating rate <= 360 operations/hour full load Safety reliability data MTTFd = 502.2 years B10d = 470000 Width 0.69 in (17.5 mm) Net Weight 0.18 lb(US) (0.08 kg) Functionality Overvoltage and undervoltage detection Compatibility code RM17 Environment Electromagnetic compatibility Emission standard for industrial environments EN/IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 Immunity for industrial environments NF EN/IEC 61000-6-2 Standards EN/IEC 60255-6 Product Certifications C-tick GOST GL CSA UL Directives 73/23/EEC - low voltage directive 89/336/EEC - electromagnetic compatibility Ambient Air Temperature for Storage -40…158 °F (-40…70 °C) Ambient air temperature for operation -4…122 °F (-20…50 °C) Relative humidity 95 % 131 °F (55 °C) IEC 60068-2-30 Vibration resistance 0.35 mm 5…57.6 Hz)IEC 60068-2-6 1 gn 57.6…150 Hz)IEC 60255-21-1 Shock resistance 5 gn IEC 60068-2-27 IP degree of protection IP20 IEC 60529 terminals) IP30 IEC 60529 casing) Pollution degree 3 IEC 60664-1 Dielectric test voltage 2 KV AC 50 Hz, 1 min IEC 60255-5 2 kV AC 50 Hz, 1 min IEC 60664-1 Non-dissipating shock wave 4 KV IEC 60255-5
4 KV IEC 60664-1
Ordering and shipping details Category 22380 - RELAYS-MEASUREMENT (RM17-RM35) Discount Schedule CP2 GTIN 3389119405157 Nbr. of units in pkg. 1 Package weight(Lbs) 3.14 oz (89 g) Returnability No Country of origin ID
Unit Type of Package 1 PCE Package 1 Height 1.06 in (2.7 cm) Package 1 width 3.07 in (7.8 cm) Package 1 Length 3.78 in (9.6 cm) Unit Type of Package 2 S02 Number of Units in Package 2 48 Package 2 Weight 10.86 lb(US) (4.927 kg) Package 2 Height 5.91 in (15 cm) Package 2 width 11.81 in (30 cm) Package 2 Length 15.75 in (40 cm) Offer Sustainability Sustainable offer status Green Premium product California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov REACh Regulation REACh Declaration EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration Mercury free Yes RoHS exemption information Yes China RoHS Regulation China RoHS Declaration Environmental Disclosure Product Environmental Profile Circularity Profile End Of Life Information WEEE The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. Contractual warranty Warranty 18 months
Single-Phase and DC Voltage Control Relays Dimensions and Mounting
Single-Phase and DC Voltage Control Relays Wiring Diagram Application Scheme (1) To sensitive loads
Control of Overvoltage and Undervoltage in Window Mode Legend Tt Time delay after crossing of threshold Un Nominal supply voltage U Monitored supply voltage H Hysteresis U> Overvoltage threshold U< Undervoltage threshold 11-12, 11-14 Output relay connections Relay status: black color = energized.