RARA manufactures load banks, ranging from small portable units for testing generators to multi-megawatt designs for larger applications. Regular load testing, along with correct battery maintenance, is the best way of ensuring the reliability of standby power systems. It is routine for all newly-installed generating sets to have a load test during the commissioning process in order to prove the performance of the set and all its ancillaries-cooling system, exhaust system, switchgear and protection schemes. + Custom designed for your particular system * Several stages of assembly depending on shipping needs - Many sizes and applications available a | ‘ : ; moa . xy j RRRPE Annan | Pitts sevey li GENERAL SPECIFICATIONS Model Rated Power eet Biggs ‘Approx. Weight Cooling Fan Source : : RLB-50V RLB-50H 50OKW 1KW 20kW 160 1 Phase RLB-100V 220 RLB-100H 100kW 1kW SOkW 220 ‘obiz RLB-200V RLB-200H 200kW kW 100kW 350 soe RLB-300V Optional RLB-300H 300kW kW 100kW 480 RLB-400V RUBYZ00E) 4O0kKW kW 200kW 530 RLB-500V RLB-500H SO0KW 5SkW 200kW 750 RLB-600V RLB-s00H 600kW 5SkW 300kW 960 RLB-800V 3 Phase RLB-800H 800kW kW 300kW 1350 380 RLB-1000V 60Hz RLB-1000H 1000KW kW SOOKW 1740 RLB-1500V soHz RUB" OOF 1500kW 5kW 500kW 2320 Optionat RLB-2000V RLB-20001 2000kW SkW 1000kW 2850 RLB-2500V RLB-2500H 2500kW SkW 1000kW 3580 RLB-3000V RLB-3000H 3000kW kW 1000kW 3970 2a Resistors And Resistive Applications Tel: 82-32-817-4325 Fax: 82-32-817-4329
Hf DIMENSIONS [mm] FOR INDOOR TYPES gs HOT AR EXAUST a5 = — 2} Ld comm ut 1 o iS ey FAN i w i G D ic) Dimensions [mm] -_ qi RLB-50V 600 800 1000 RLB-100V 800 1050 1200 RLB-200V 800 1050 1200 RLB-300V, 1000 1250 1650 RLB-400V 1000 1250 1650 RLB-500V 1650 1300 1800 RLB-600V 1650 1300 1800 RLB-800V 2200 1600 2350 RLB-1000V 2200 1600 2350 RLB-1500V 2200 1600 2350 RLB-2000V 2200 1600 2350 RLB-2500V 20" Container RLB-3000V 20" Container I DIMENSIONS [mm] FOR OUTDOOR TYPES —<—S = a i i fa i i ' Lal | “T ' i Hor AR | : | EXHAUST | (_ Low CABLE BY CUSTOMER Dimensions [mm] _ q RLB-50H 1000 600 700 RLB-100H 1200 1000 800 RLB-200H 1600 1000 950 RLB-300H 1850 1200 1200 RLB-400H 1850 1200 1200 RLB-500H 1900 1300 1700 RLB-600H 1900 1300 1700 RLB-800H 2000 1500 2000 RLB-1000H 2600 1500 2150 RLB-1500H 2800 1500 2150 RLB-2000H 3000 2200 2350 RLB-2500H 20" Container RLB-3000H 20" Container Website: www.raraohm.com E-mail: sg@raraohm.com p25
1100kW 924kW 1212A 689kW 1047A 231kW 606A 1000kW 840kW 1102A 627kW 953A 210kW 551A 800kW 672kW 882A ‘501kW 761A 168kW AAA 600kW 504kW 661A 376kW 571A 126kW 331A ‘500kW 420kW 551A 313kW AT6A 105kW 276A 200kW 168kW 220A 125kW 190A A2KW 110A 100kW 84kW 110A 63kW 96M 21kW 55A SOkW 42KW 55A 3tkW 4TA 10.5kW 27.5A 30kW 25.2kW 3A 19kW 298 6.3kW 16.54 10kW B.4KW A kW 1A 2.1kW 5.54 SkW 42kW 5.54 3kW 458 1.05kW 2.754 Wi ADDITIONAL INFORMATION 1. The V type is an indoor model. 2. The H type is both indoor and outdoor. 3. Options: Main switch, Digital meter, Air circuit breaker, Connection cable. 4. Applied voltage: 3 phase, 480V, 60Hz.(220V, 380V, 440V, 600V, 3.3KV, 6.6KV are also available) 5. Environmental Conditions: Ambient temperature lower than 40C; Altitude less than 1000m. 6. Basic accessories are as follows: “Step load on-off switch “Magnetic contactor “Control MCCBI1 phase, 220V, 60H) “Alarm signal - pilot lamp “Emergency stop button “Reset button -Fan failure protection “Over temperature protection *Cooling fan li ORDERING INFORMATION AND NOTES Model # Power V: Vertical = indoor Element Applied AT: AC,30 Tolerance Capacity H: Horizontal = outdoor Type Voltage AS: AC, 10 D: DC 26 | Resistors And Resistive Applications Tel: 82-32-817-4325 Fax: 82-32-817-4329