RHRP30100 INTERSIL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Features

  • Avalanche Energy Rated
  • Planar Construction

Applications

  • Switching Power Supplies
  • Power Switching Circuits
  • General Purpose Packaging JEDEC TO-220AC

Ordering Information

RHRP30100 TO-220AC RHR30100 NOTE: When ordering, use the entire part number. K A ANODE CATHODE CATHODE (FLANGE) Absolute Maximum Ratings TC = 25oC, Unless Otherwise Specified RHRP30100 UNITS (TC = 95oC) 30 A (Square Wave, 20kHz) 70 A (Halfwave, 1 Phase, 60Hz) 325 A Data Sheet January 2000 File Number 3940.2 1-888-INTERSIL or 321-724-7143| Copyright © Intersil Corporation 2000

VF = Instantaneous forward voltage (pw = 300µs, D = 2%). IR = Instantaneous reverse current. trr = Reverse recovery time (Figure 9), summation of ta + tb. ta = Time to reach peak reverse current (See Figure 9). tb = Time from peak IRM to projected zero crossing of IRM based on a straight line from peak IRM through 25% of IRM (See Figure 9). Q RR = Reverse recovery charge. R θJC = Thermal resistance junction to case. FIGURE 1. FORWARD CURRENT vs FORWARD VOLTAGE FIGURE 2. REVERSE CURRENT vs REVERSE VOLTAGE

All Intersil semiconductor products are manufactured, assembled and tested underISO9000 quality systems certification. from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries. FIGURE 8. trr TEST CIRCUIT FIGURE 9. t rr WAVEFORMS AND DEFINITIONS FIGURE 10. AVALANCHE ENERGY TEST CIRCUIT FIGURE 11. AVALANCHE CURRENT AND VOLTAGE

0.25 IRM