2k 243 Ω ADJ RH137 BI OUTPUT–40V Operating Junction D UESCRIPTIO A UGWA WU WARBSOLUTEX I T I S , LTC and LT are registered trademarks of Linear Technology Corporation. WU UPACKAGE/ORDER I FOR ATIOBUR -I CIRCUITU U BOTTOM VIEW ADJ VOUT VIN CASE IS INPUT H PACKAGE 3-LEAD TO-39 METAL CAN VOUT CASE IS VIN ADJ K PACKAGE 2-LEAD TO-3 METAL CAN (STEEL) BOTTOM VIEW The RH137 negative adjustable regulator will deliver up to 1.5A output current over an output voltage range of –1.2V to –32V. Every effort has been made to make these devices easy to use and difficult to damage. Internal current and power limiting coupled with true thermal limiting prevents device damage due to overloads or shorts, even if the regulator is not fastened to a heat sink. Maximum reliability is attained with Linear Technology’s advanced processing techniques combined with a 100% burn-in in the thermal limit mode. This assures that all device protection circuits are working and eliminates field failures experienced with other regulators that receive only standard electrical testing. The wafer lots are processed to Linear Technology’s in- house Class S flow to yield circuits usable in stringent military applications.
TA = 25°C SUB- SUB- SYMBOL PARAMETER CONDITIONS NOTES MIN TYP MAX GROUP MIN TYP MAX GROUP UNITS VREF Reference Voltage VIN – VOUT = 5V, IOUT = 10mA –1.225 –1.275 1 V 3V VIN – VOUT 40V, –1.200 –1.300 1 –1.200 –1.300 2,3 V 10mA I OUT I MAX, P P MAX V OUT Line Regulation 3V VIN – VOUT 40V 2 0.02 1 0.05 2,3 %/ V V IN V OUT Load Regulation 10mA I OUT I MAX, VOUT 5V 2 25 1 50 2,3 mV I OUT 10mA I OUT I MAX, VOUT 5V 2 0.5 1 1 2,3 % Thermal Regulation 10ms Pulse 0.02 1 %/W Ripple Rejection V OUT = –10V, f = 120Hz, C ADJ = 0 60 dB VOUT = –10V, f = 120Hz, 3 66 66 dB CADJ = 10µF IADJ Adjust Pin Current 100 1 100 2,3 µA I ADJ Adjust Pin Current 10mA I OUT I MAX 5 1 5 2,3 µA Change 3V VIN – VOUT 40V 5 1 5 2,3 µA IMIN Minimum Load VIN – VOUT = 40V 5 1 5 2,3 mA Current VIN – VOUT 10V 3 1 3 2,3 mA Current Limit VIN – VOUT 15V H Package 0.5 1.5 1 0.5 2,3 A K Package 1.5 3.2 1 1.5 2,3 A VIN – VOUT = 40V H Package 0.15 0.5 1 A K Package 0.24 1.0 1 A V OUT Temperature Stability –55°C T J 125°C 3 0.6 % Temp V OUT Long Term Stability T A = 125°C 3 1 % Time en RMS Output Noise 10Hz f 10kHz 0.003 % θJC Thermal Resistance H Package 3 15 °C/W (Junction to Case) K Package 3 3 °C/W TABLE 1: ELECTRICAL CHARACTERISTICS (Preirradiation) (Note 1) –55°C T A 150°C 50KRAD(Si)20KRAD(Si)10KRAD(Si) 100KRAD(Si) 200KRAD(Si) SYMBOL PARAMETER CONDITIONS NOTES MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX UNITS IOUT = 10mA 10mA I OUT I MAX, P P MAX V IN V OUT Load Regulation 10mA I OUT I MAX, 2 25 25 25 25 25 mV I OUT VOUT 5V VOUT 5V TABLE 1A: ELECTRICAL CHARACTERISTICS (Postirradiation) (Note 4)
Information furnished by Linear Technology Corporation is believed to be accurate and reliable. However, no responsibility is assumed for its use. Linear Technology Corporation makes no represen- tation that the interconnection of its circuits as described herein will not infringe on existing patent rights. 50KRAD(Si)20KRAD(Si)10KRAD(Si) 100KRAD(Si) 200KRAD(Si) SYMBOL PARAMETER CONDITIONS NOTES MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX UNITS IADJ Adjust Pin Current 100 100 100 100 100 µA I ADJ Adjust Pin Current Change 10mA I OUT I MAX 55 5 55 µ A 3V VIN – VOUT= 40V 5 5 5 5 5 µA IMIN Minimum Load Current VIN – VOUT= 40V 5 5 5 5 5 mA VIN – VOUT 10V 3 3 3 3 3 mA TABLE 1A: ELECTRICAL CHARACTERISTICS (Postirradiation) (Note 4) Note 1: Unless otherwise specified, these specifications apply for VIN – VOUT= 5V; and IOUT = 0.1A for the H package (TO-39) and IOUT = 0.5A for the K package (TO-3) package. Although power dissipation is internally limited, these specifications are applicable for power dissipations of 2W for the TO-39 and 20W for the TO-3. I MAX is 0.2A for the TO-39 and 1.5A for the TO-3 package. Note 2: Regulation is measured at a constant junction temperature using pulse testing with a low duty cycle. Changes in output voltage due to heating effects are covered under the specification for thermal regulation. Note 3: Guaranteed by design, characterization or correlation to other tested parameters. Note 4: T J = 25°C unless otherwise noted . MIL-STD-883 TEST REQUIREMENTS SUBGROUP Final Electrical Test Requirements (Method 5004) 1*,2,3 Group A Test Requirements (Method 5005) 1,2,3 Group C and D End Point Electrical Parameters 1 (Method 5005) * PDA Applies to subgroup 1. See PDA Test Notes. PDA Test Notes The PDA is specified as 5% based on failures from group A, subgroup 1, tests after cooldown as the final electrical test in accordance with method 5004 of MIL-STD-883 Class B. The verified failures of group A, subgroup 1, after burn-in divided by the total number of devices submitted for burn- in in that lot shall be used to determine the percent for the lot. Linear Technology Corporation reserves the right to test to tighter limits than those given. TABLE 2: ELECTRICAL TEST REQUIRE E TS U W TOTAL DOSE BIAS CIRCUIT RH137 VIN 243Ω2k ADJ –15V RH137 TDBC OUTPUT CASE
Linear Technology Corporation 1630 McCarthy Blvd., Milpitas, CA 95035-7417 (408) 432-1900 l FAX: (408) 434-0507 l TELEX: 499-3977 LINEAR TECHNOLOGY CORPORA TION 1990 LT/HP 0896 500 REV A • PRINTED IN USA I.D. No. 66-10-0175 Rev. A 0896 TYPICAL PERFORMANCE CHARACTERISTICS UW Reference Voltage Current Limit Adjust Current Minimum Load Current Dropout Voltage Regulation TOTAL DOSE KRAD (Si) REFERENCE VOLTAGE (V) 1.28 1.27 1.26 1.25 1.24 1.23 1.22 10 100 1000 RH137 G01 10mA ≤ IOUT ≤ IMAX TOTAL DOSE KRAD (Si) CURRENT LIMIT (A) 3.0 2.5 2.0 1.5 1.0 0.5 –0.5 10 100 1000 RH137 G02 VIN – VOUT = 5V VIN – VOUT= 40V TOTAL DOSE KRAD (Si) ADJUST CURRENT (µA) 100 10 100 1000 RH137 G03 VIN – VOUT = 40V TOTAL DOSE KRAD (Si) MINIMUM LOAD CURRENT (mA) 3.0 2.5 2.0 1.5 1.0 0.5 10 100 1000 RH137 G04 VIN – VOUT = 10V TOTAL DOSE KRAD (Si) DROPOUT VOLTAGE (V) 3.0 2.5 2.0 1.5 1.0 0.5 10 100 1000 RH137 G05 (VIN – VOUT) = 10V TOTAL DOSE KRAD (Si) REGULATION (mV) 10 100 1000 RH137 G06 LOAD LINE