Features
- 2400-2483.5 MHz ISM band operation
- Support 1 and 2 Mbps air data rate
- Programmable output power (-5dBm to +20dBm)
- Low power consumption
- Variable payload length from 1 to 32bytes
- Automatic packet processing
- 6 data pipes for 1:6 star networks
- 4-pin SPI interface with maximum 8 MHz clock rate
- DIP-10pin and SMD-10pin Package
Applications
- Wireless PC peripherals
- Wireless mice and keyboards
- Wireless gamepads
- Wireless audio
- VOIP and wireless headsets Block Diagram RFM73P-S2
- Remote controls
- Consumer electronics
- Home automation
- Toys
- Personal health and entertainment
RFM73P-S2 V2.0 Table of Contents Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
1 General Description
RFM73P-S2 is a GFSK transceiver module operating in the world wide ISM frequency band at 2400 - 2483.5 MHz. Burst mode transmission and up to 2Mbps air data rate make them suitable for applications requiring ultra l ow p ower consumption.The embedded packet processing engines enable their full operation with a very simple MCU as a radio system.Auto re-transmission and auto acknowledge give reliable link without any MCU interference. RFM73P-S2 operates in TDD mode, either as a transmitter or as a receiver. The RF channel frequency determines the center of the channel used by RFM73P-S2. The frequency is set by the RF_CH register in register bank 0 acc ording to t he following formula: F0= 2400 + RF_CH (MHz). The resolution of the RF channel frequency is 1MHz. A transmitter and a receiver must be programmed with the same RF channel frequency to be able to communicate with each other. The output power of RFM73P-S2 is set by the RF_PWR bits in the RF_SETUP register. Demodulation is done with embedded data slicer and bit recovery logic. The air data rate can be programmed to 1Mbps or 2Mbps by RF_DR register. A transmitter and a receiver must be programmed with the same setting. In the following chapters, all registers are in register bank 0 except with explicit claim. Figure 1 RFM73P-S2 Chip Block Diagram RFM73P-S2 V2.0 Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
2 Abbreviations
ARC Auto Retransmission Count ARD Auto Retransmission Delay CD Carrier Detection CE Chip Enable CRC Cyclic Redundancy Check CSN Chip Select Not DPL Dynamic Payload Length FIFO First-In-First-Out GFSK Gaussian Frequency Shift Keying GHz Gigahertz LNA Low Noise Amplifier IRQ Interrupt Request ISM Industrial-Scientific-Medical LSB Least Significant Bit MAX_RT Maximum Retransmit Mbps Megabit per second MCU Microcontroller Unit MHz Megahertz MISO Master In Slave Out MOSI Master Out Slave In MSB Most Significant Bit PA Power Amplifier PID Packet Identity Bits PLD Payload PRX Primary RX PTX Primary TX PWD_DWN Power Down PWD_UP Power Up RF_CH Radio Frequency Channel RSSI Received Signal Strength Indicator RX Receive RX_DR Receive Data Ready SCK SPI Clock SPI Serial Peripheral Interface TDD Time Division Duplex TX Transmit TX_DS Transmit Data Sent RFM73P-S2 V2.0 Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
3 Pin Information
Figure 2 RFM73P-S2 pin assignments (top view) Name Pin Function Description GND Ground Ground (0 V) VDD Power Power Supply (3.3V to 4.2V DC) CE Digital Input Chip Enable Activates RX or TX mode CSN Digital Input SPI Chip Select, Active low SCK Digital Input SPI Clock MOSI Digital Input SPI Slave Data Input MISO Digital Output SPI Slave Data Output with tri-state option IRQ Digital Output Maskable interrupt pin, Active low TREN Digital Input 1=TX Active 0=RX Active PAEN Digital Input 1=Chip is Active 0=chip is Shut- down Note: 1、When module in the transmit mode, TREN = 1 and PAEN = 1. 2、When module in the receive mode, TREN = 0 and PAEN = 1. 3、When module in the sleep mode, TREN = 0 and PAEN = 0.The PA IC will close, then the sleep current will be very low. Table 1 RFM73P-S2 pin functions RFM73P-S2 V2.0 Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
4 State Control
4.1 State Control Diagram
- Pin signal: VDD, CE
- SPI register: PWR_UP, PRIM_RX, EN_AA, NO_ACK, ARC, ARD
- System information: Time out, ACK received, ARD elapsed, ARC_CNT, TX FIFO empty, ACK pa cket transmitted, Packet received RFM73P-S2 has built-in state machines that control t he state transition between different modes. When auto acknowledge feature is disabled, state transition will be fully controlled by MCU. VDD>=3.3 V Power Down PWR_UP=1 PWR_UP=0 Standby-I Time out or ACK received CE=1 ARD elapsed and ARC_CNT<ARC CE=0 CE=0 TX FIFO empty RX TX Standby-II TX FIFO EN_AA=1 NO_ACK=0 Figure 3 PTX (PRIM_RX=0) state control diagram RFM73P-S2 V2.0 Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
VDD>=3.3 V Power Down PWR_UP=1 PWR_UP=0 Standby-I CE=1 CE=0 CE=0 ACK packet transmitted RX TX Packet received EN_AA=1 NO_ACK=0 Figure 4 PRX (PRIM_RX=1) state control diagram
4.2 Power Down Mode
In power down mode RFM73P-S2 is in sleep mode with minimal current consumption. SPI interface is still active in this mode, and all register values are a vailable by SPI. Power down mode is entered by setting the PWR_UP bit in the CONFIG register to low.
4.3 Standby-I Mode
By setting the PWR_UP bit in the CONFIG register to 1 and de-asserting CE to 0, the device enters standby-I mode. Standby-I mode is used to minimize average current consumption while maintaining short start-up time. In this mode, part of the crystal oscillator is a ctive. This is also the mode which the RFM73P-S2 returns to from TX or RX mode when CE is set low.
4.4 Standby-II Mode
In standby-II mode more clock buffers are active than in standby-I mode and much more current is u sed. Standby-II occurs when CE is held high on a PTX device with empty TX FIFO. If a new packet is uploaded to the TX FIFO in this mode, the device will automatically enter TX mode and t he packet is transmitted.
4.5 TX Mode
- PTX device (PRIM_RX=0) The TX mode is an active mode where the PTX device transmits a packet. To enter this mode from power down mode, the PTX device must have the PWR_UP bit set high, PRIM_RX bit set low, a payload in the TX FIFO, and a high pulse on the CE for more than 10µ s. RFM73P-S2 V2.0 Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
The PTX device stays in TX mode until it finishes transmitting the current packet. If CE = 0 it returns to standby-I mode. If CE = 1, the next action is determined by the status of the TX FIFO. If the TX FIFO is not empty the PTX device remains in TX mode, transmitting the next packet. If the TX FIFO is empty the PTX device goes into standby-II mode. If the auto retransmit is enabled (EN_AA=1) and auto acknowledge is required (NO_ACK=0), the PTX device will enter TX mode from standby-I mode when ARD elapsed and number of retried is le ss than ARC.
- PRX device (PRIM_RX=1) The PRX device will enter TX mode from RX mode only when EN_AA=1 and NO_ACK=0 in received packet to transmit acknowledge packet with pending payload in TX FIFO.
4.6 RX Mode
- PRX device (PRIM_RX=1) The RX mode is an a ctive mode where the RFM73P-S2 radio is c onfigured to be a receiver. To enter this mode from standby-I mode, the PRX device must have the PWR_UP bit set high, PRIM_RX bit set high and the CE pin
5 Packet Processing
set high. Or PRX device can enter this mode from TX mode after transmitting an acknowledge packet when EN_AA=1 and NO_ACK=0 in received packet. In this mode the receiver demodulates the signals from the RF c hannel, constantly presenting the demodulated data to the packet processing engine. The packet processing engine continuously searches for a valid packet. If a valid packet is found (by a matching address and a valid CRC) the payload of the packet is presented in a vacant slot in the RX FIFO. If the RX FIFO is full, the received packet is discarded. The PRX device remains in RX mode until the MCU configures it to standby-I mode or power down mode. In RX mode a carrier detection (CD) signal is available. The CD is set to high when a RF signal is detected inside the receiving frequency channel. The internal CD signal is filtered before presented to CD register. The RF signal must be present for at least 128 µ s before the CD is set high.
- PTX device (PRIM_RX=0) The PTX device will enter RX mode from TX mode only when EN_AA=1 and NO_ACK=0 to receive acknowledge packet.
5.1 Packet Format
The packet format has a preamble, address, packet control, payload and CRC field. Preamble 1 byte Address 3~5 byte Packet Control 9/0 bit Payload 0~32 byte CRC 2/1 byte Payload Length 6 bit PID 2 bit NO_ACK 1 bit Figure 5 Packet Format RFM73P-S2 V2.0 Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
5.1.1 Preamble
The preamble is a bit sequence used to detect 0 and 1 levels in the receiver. The preamble is one byte long and is either 01010101 or 10101010. If the first bit in the address is 1 the preamble is automatically set to 10101010 and if the first bit is 0 the preamble is automatically set to 01010101. This is done to ensure there are enough transitions in the preamble to stabilize the receiver.
5.1.2 Address
This is the address for the receiver. An address ensures that the packet is detected by the target receiver. The address field can be configured to be 3, 4, or 5 bytes long by the AW register. The PRX device can open up to six data pipes to support up to six PTX devices with unique addresses. All six PTX device addresses are searched simultaneously. In PRX side, the data pipes are enabled with the bits in the EN_RXADDR register. By default only data pipe 0 and 1 are enabled. Each data pipe address is configured in the RX_ADDR_PX registers. Each pipe can have up to 5 bytes configurable address. Data pipe 0 has a unique 5 byte address. Data pipes 1-5 share the 4 most significant address bytes. The LSB byte must be unique for all 6 pipes. To ensure that the ACK packet from the PRX is transmitted to the correct PTX, the PRX takes the data pipe address where it received the packet and uses it as the TX address when transmitting the ACK packet. On the PRX the RX_ADDR_Pn, defined as the pipe address, must be unique. On the PTX the TX_ADDR must be the same as the RX_ADDR_P0 on the PTX, and as the pipe address for the designated pipe on the PRX. No other data pipe can receive data until a complete packet is received by a data pipe that has detected its address. When multiple PTX devices are transmitting to a PRX, the ARD can be u sed to skew the auto retransmission so that they only block each other once.
5.1.3 Packet ontrol
When Dynamic Payload Length function is enabled, the packet control field contains a 6 bit payload length field, a 2 bit PID (Packet Identity) field and, a 1 bit NO_ACK flag.
- Payload length The payload length field is only used if the Dynamic Payload Length function is enabled.
- PID The 2 bit PID field is used to detect whether the received packet is new or retransmitted. PID prevents the PRX device from presenting the same payload more than once to the MCU. The PID field is incremented at the TX side for each new packet received through the SPI. The PID and CRC fields are used by t he PRX device to determine whether a packet is old or new. When several data packets are lost on the link, the PID fields may become equal to the last received PID. If a packet has the same PID as the previous packet, RFM73P-S2 compares the CRC sums from both packets. If the CRC sums are also equal, the last received packet is considered a copy of the previously received packet and discarded.
- NO_ACK The NO_ACK flag is o nly used when the auto acknowledgement feature is used. Setting the flag high, tells the receiver that the packet is not to be auto acknowledged. The PTX can set the NO_ACK flag bit in the Packet Control Field with the command: W_TX_PAYLOAD_NOACK.However, the function must first be enabled in the FEATURE register bysetting the EN_DYN_ACK bit. When you use this option, RFM73P-S2 V2.0 Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com the PTX goes directly to standby-I mode after transmitting the packet and the PRX does not transmit an ACK packet when it receives the packet.
5.1.4 Payload
The payload is the user defined content of the packet. It can be 0 to 32 bytes wide, and it is transmitted on-air as it is uploaded (unmodified) to the device. The R FM73P-S2 provides two alternatives for handling payload lengths, static and dynamic payload length. The static payload length of each of six data pipes can be individually set. The default alternative is static payload length. With static payload length all packets between a transmitter and a receiver have the same length. Static payload length is set by the RX_PW_Px registers. The payload len gth on the transmitter side is set by the number of bytes clocked into t he TX_FIFO and must equal the value in the RX_PW_Px register on the receiver side. Each pipe has its own payload length. Dynamic Payload Length (DPL) is an alternative to static payload length. DPL enables the transmitter to send packets with variable payload length to the receiver. This means for a system with different payload lengths it is not necessary to scale the packet length to the longest payload. With DPL feature the RFM73P-S2 can decode the payload length of the received packet automatically instead of u sing the RX_PW_Px registers. The MCU can read the length of the received payload by using the command: R_RX_PL_WID. In order to enable DPL the EN_DPL bit in the FEATURE register must be set. In RX mode the D YNPD register has to be set. A PTX that transmits to a PRX with DPL enabled must have the DPL_P0 bit in DYNPD set.
5.1.5 CRC
The CRC is the error detection mechanism in the packet. The number of bytes in the CRC is set by the CRCO bit in the CONFIG register. It may be either 1 or 2 bytes and is calculated over the ad dress, Packet Control Field, and Payload. The polynomial for 1 byte CRC is X8 + X2 + X + 1. Initial value is 0xFF. The polynomial for 2 byte CRC is X16 + X12 + X5 + 1. Initial value is 0xFFFF. No packet is accepted by receiver side if the CRC fails.
5.2 Packet Handling
RFM73P-S2 uses burst mode for payload transmission and receive. The transmitter fetches payload from TX FIFO, automatically assembles it i nto packet and transmits the packet in a very short burst period with 1Mbps or 2Mbps air data rate. After transmission, if the PTX packet has the NO_ACK flag set, RFM73P-S2 sets TX_DS and gives an active low interrupt IRQ to MCU. If the PTX is ACK packet, the PTX needs receive ACK from the PRX and then asserts the TX_DS IRQ. The receiver automatically validates and disassembles received packet, if there is a valid packet within the new payload, it will write the payload into RX FIFO, set RX_DR and give an active low interrupt IRQ to MCU. When auto acknowledge is enabled (EN_AA=1), the PTX device will automatically wait for acknowledge packet after transmission, and re-transmit original packet with the d elay of ARD until an acknowledge packet is received or the number of re-transmission exceeds a threshold ARC. If the later one h appens, RFM73P-S2 will set MAX_RT and give an active low interrupt RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com IRQ to MCU. Two packet loss counters (ARC_CNT and PLOS_CNT) are incremented each time a packet is l ost. The ARC_CNT counts the nu mber of retransmissions for the current transaction. The PLOS_CNT counts the total n umber of retransmissions since the last channel change. ARC_CNT is reset by initiating a new transaction. PLOS_CNT is reset by writing to the RF_CH register. It is possible to use the information in the OBSERVE_TX register to make an overall assessment of the channel quality. The PTX device will retransmit if its RX FIFO is full but received ACK frame has payload. As an alternative for PTX device to auto retransmit it is possible to manually set the RFM73P-S2 to retransmit a packet a number of times. This is done by t he REUSE_TX_PL command. When a uto acknowledge is enabled, the PRX device will automatically check the NO_ACK field in received packet, and if NO_ACK=0, it will automatically send an acknowledge packet to PTX device. If EN_ACK_PAY is set, and the a cknowledge packet can also include pending payload in TX FIFO.
6 Data and Control Interface
6.1 TX/RX FIFO
The data FIFOs are used to store payload that is to be transmitted (TX FIFO) or payload that is received and ready to be clocked out (RX FIFO). The FIFO is accessible in both PTX mode and PRX mode. There are three levels 32 bytes FIFO for both TX and RX, supporting both acknowledge mode or no acknowledge mode with up to six pipes.
- TX three levels, 32 byte FIFO
- RX three levels, 32 byte FIFO Both FIFOs have a controller and are accessible through the SPI by u sing dedicated SPI commands. A TX FIFO in PRX can store payload for ACK packets to three different PTX devices. If the TX FIFO contains more than one payload to a pipe, payloads are handled using the first in first out principle. The TX FIFO in a PRX is blocked if all pending payloads are addressed to pipes where the link to the PTX is lost. In this case, the MCU can flush the TX FIFO by using the FLUSH_TX command. The RX FIFO in PRX may contain payload from up to three different PTX devices. A TX FIFO in PTX can have up to three payloads stored. The TX FIFO can be written to by three commands, W_TX_PAYLOAD and W_TX_PAYLOAD_NO_ACK in PTX mode and W_ACK_PAYLOAD in PRX mode. All three commands give access to the TX_PLD register. The RX FIFO can be read by the command R_RX_PAYLOAD in both PTX and PRX mode. This command gives access to the RX_PLD register. The payload in TX FIFO in a PTX is NOT removed if the MAX_RT IRQ is asserted. In the FIFO_STATUS register it is possible to read if the TX and RX FIFO are full or empty. The TX_REUSE bit is also available in the FIFO_STATUS register. TX_REUSE is set by the SPI command REUSE_TX_PL, and is reset by the SPI command: W_TX_PAYLOAD or FLUSH TX.
6.2 Interrupt
In RFM73P-S2 there is an active low interrupt (IRQ) pin, which is activated when TX_DS IRQ, RX_DR IRQ or MAX_RT IRQ are set high by the state machine in the STATUS register. The IRQ pin resets when MCU writes '1' to the IRQ source bit in the STATUS register. The IRQ mask in the CONFIG RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com register is used to select the IRQ sources that are allowed to assert the IRQ pin. By setting one of the MASK bits high, the corresponding IRQ source is disabled. By default all IRQ sources are enabled. The 3 bit pipe information in the STATUS register is updated during the IRQ pin high to low transition. If the STATUS register is read during an IRQ pin high to low transition, the pipe information is unreliable.
6.3 SPI Interface
6.3.1 SPI Command
The SPI commands are shown in Table 2. Every new command must be started by a high to low transition on CSN. In parallel to the SPI command word applied on t he MOSI pin, the STATUS register is shifted serially out on the MISO pin. The serial shifting SPI commands is in the following format:
- <Command word: MSB bit to LSB bit (one byte)>
- <Data bytes: LSB byte to MSB byte, MSB bit in each byte first> for all registers at bank 0 a nd register 9 to register 14 at bank 1
- <Data bytes: MSB byte to LSB byte, MSB bit in each byte first> for register 0 to register 8 at bank 1 Command name Command word (binary) # Data bytes Operation R_REGISTER 000A AAAA 1 to 5 LSB byte first Read command and status registers. AAAAA = 5 bit Register Map Address W_REGISTER 001A AAAA 1 to 5 LSB byte first Write command and status registers. AAAAA = 5 bit Register Map Address Executable in power down or standby modes only. R_RX_PAYLOAD 0110 0001 1 to 32 LSB byte first Read RX-payload: 1 – 32 bytes. A read operation always starts at byte 0. Payload is deleted from FIFO after it is read. Used in RX mode. W_TX_PAYLOAD 1010 0000 1 to 32 LSB byte first Write TX-payload: 1 – 32 bytes. A write operation always starts at byte 0 used in TX payload. FLUSH_TX 1110 0001 0 Flush TX FIFO, used in TX mode FLUSH_RX 1110 0010 Flush RX FIFO, used in RX mode Should not be executed during transmission of acknowledge, that is, acknowledge package will not be completed. REUSE_TX_PL 1110 0011 Used for a PTX device Reuse last transmitted payload. Packets are repeatedly retransmitted as long as CE is high. TX payload reuse is active until W_TX_PAYLOAD or FLUSH TX is executed. TX payload reuse must not be activated or deactivated during package transmission RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com ACTIVATE 0101 0000 This write command followed by data 0x73 activates the following features:
- R_RX_PL_WID
- W_ACK_PAYLOAD
- W_TX_PAYLOAD_NOACK A new ACTIVATE command with the same data deactivates them again. This is executable in power down or stand by modes only. The R_RX_PL_WID, W_ACK_PAYLOAD, and W_TX_PAYLOAD_NOACK features registers are initially in a deactivated state; a write has no effect, a read only results in zeros on MISO. To activate these registers, use the ACTIVATE command followed by data 0x73. Then they can be accessed as any other register. Use the same command and data to deactivate the registers again. This write command followed by data 0x53 toggles the register bank, and the current register bank number can be read out from REG7 [7] R_RX_PL_WID 0110 0000 Read RX-payload width for the top R_RX_PAYLOAD in the RX FIFO. W_ACK_PAYLOAD 1010 1PPP 1 to 32 LSB byte first Used in RX mode. Write Payload to be transmitted together with ACK packet on PIPE PPP. (PPP valid in the range from 000 to 101). Maximum three ACK packet payloads can be pending. Payloads with same PPP are handled using first in - first out principle. Write payload: 1– 32 bytes. A write operation always starts at byte 0. W_TX_PAYLOAD_NO ACK 1011 0000 1 to 32 LSB byte first Used in TX mode. Disables AUTOACK on this specific packet. NOP 1111 1111 0 No Operation. Might be used to read the STATUS register Table 2 SPI command
6.3.2 SPI Timing
Write to SPI register: MOSI x C7 C6 C5 C4 C3 C2 C1 C0 x D7 D6 D5 D4 D3 D2 D1 D0 x MISO HI-Z S7 S6 S5 S4 S3 S2 S1 S0 0 0 0 0 0 0 0 0 Hi-Z Read from SPI register: MOSI x C7 C6 C5 C4 C3 C2 C1 C0 x MISO x S7 S6 S5 S4 S3 S2 S1 S0 D7 D6 D5 D4 D3 D2 D1 D0 x Figure 6 SPI timing RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com Cn: SPI command bit Sn: STATUS register bit Dn: Data Bit (LSB byte to MSB byte, MSB bit in each byte first) Note: The SPI timing is for bank 0 and register 9 to 14 at bank 1. For register 0 to 8 at bank 1, the byte order is inversed that the MSB byte is R/W before LSB byte. Figure 7 SPI NOP timing diagram Symbol Parameters Min Max Units Tdc Data to SCK Setup 10 ns Tdh SCK to Data Hold 2 ns Tcsd CSN to Data Valid 38 ns Tcd SCK to Data Valid 55 ns Tcl SCK Low Time 40 ns Tch SCK High Time 40 ns Fsck SCK Frequency 0 8 MHz Tr,Tf SCK Rise and Fall 100 ns Tcc CSN to SCK Setup 2 ns Tcch SCK to CSN Hold 2 ns Tcwh CSN Inactive time 50 ns Tcdz CSN to Output High Z 38 ns Table 3 SPI timing parameter RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
7 Register Map
There are two register banks, which can be toggled by SPI command “ACTIVATE” followed with 0x53 byte, and bank status can be read from Bank0_REG7 [7].
7.1 Register Bank 0
(Hex) Mnemonic Bit Reset Value Type
Description
00 CONFIG Configuration Register
Reserved 7 0 R/W Only '0' allowed MASK_RX_DR 6 0 R/W Mask interrupt caused by RX_DR 1: Interrupt not reflected on the IRQ pin 0: Reflect RX_DR as active low interrupt on the IRQ pin MASK_TX_DS 5 0 R/W Mask interrupt caused by TX_DS 1: Interrupt not reflected on the IRQ pin 0: Reflect TX_DS as active low interrupt on the IRQ pin MASK_MAX_RT 4 0 R/W Mask interrupt caused by MAX_RT 1: Interrupt not reflected on the IRQ pin 0: Reflect MAX_RT as active low interrupt on the IRQ pin EN_CRC 3 1 R/W Enable CRC. Forced high if one of the bits in the EN_AA is high CRCO 2 0 R/W CRC encoding scheme '0' - 1 byte '1' - 2 bytes PWR_UP 1 0 R/W 1: POWER UP, 0:POWER DOWN PRIM_RX 0 0 R/W RX/TX control, 1: PRX, 0: PTX
01 EN_AA
Enable „Auto Acknowledgment‟ Function Reserved 7:6 00 R/W Only '00' allowed ENAA_P5 5 1 R/W Enable auto acknowledgement data pipe 5 ENAA_P4 4 1 R/W Enable auto acknowledgement data pipe 4 ENAA_P3 3 1 R/W Enable auto acknowledgement data pipe 3 ENAA_P2 2 1 R/W Enable auto acknowledgement data pipe 2 ENAA_P1 1 1 R/W Enable auto acknowledgement data pipe 1 ENAA_P0 0 1 R/W Enable auto acknowledgement data pipe 0
02 EN_RXADDR Enabled RX Addresses
Reserved 7:6 00 R/W Only '00' allowed ERX_P5 5 0 R/W Enable data pipe 5. ERX_P4 4 0 R/W Enable data pipe 4. ERX_P3 3 0 R/W Enable data pipe 3. ERX_P2 2 0 R/W Enable data pipe 2. ERX_P1 1 1 R/W Enable data pipe 1. ERX_P0 0 1 R/W Enable data pipe 0. RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
03 SETUP_AW Setup of Address Widths
(common for all data pipes) Reserved 7:2 000000 R/W Only '000000' allowed AW 1:0 11 R/W RX/TX Address field width '00' - Illegal '01' - 3 bytes '10' - 4 bytes '11' - 5 bytes LSB bytes are used if address width is below 5 bytes
04 SETUP_RETR Setup of Automatic Retransmission
ARD 7:4 0000 R/W Auto Retransmission Delay „0000‟ – Wait 250 us „0001‟ – Wait 500 us „0010‟ – Wait 750 us …….. „1111‟ – Wait 4000 us (Delay defined from end of transmission to start of next transmission) ARC 3:0 0011 R/W Auto Retransmission Count „0000‟ –Re-Transmit disabled „0001‟ – Up to 1 Re-Transmission on fail of AA „1111‟ – Up to 15 Re-Transmission on fail of AA
05 RF_CH RF Channel
Reserved 7 0 R/W Only '0' allowed RF_CH 6:0 0000010 R/W Sets the frequency channel
06 RF_SETUP RF Setup Register
RF_DR_LOW 5 0 R/W Set Air Data Rate.See RF_DR_HIGH for encoding PLL_LOCK 4 0 Force PLL lock single .Only used in test RF_DR_HIGH 3 1 R/W Set Air Data Rate Encoding : RF_DR_LOW, RF_DR_HIGH 0„0 – 1Mbps 0„1 – 2Mbps(default) 1,0 – 250Kbps 1,1 – 2Mbps RF_PWR[1:0] 2:1 R/W Set RF output power in TX mode RF_PWR[1:0] '00' – -10 dBm '01' – -5 dBm '10' – 0 dBm '11' – 5 dBm LNA_HCURR R/W Setup LNA gain 0:Low gain(20dB down) 1:High gain STATUS Status Register (In parallel to the SPI command word applied on the MOSI pin, the STATUS register is shifted serially out on the MISO pin) RBANK R Register bank selection states. Switch register bank is done by SPI command “ACTIVATE” followed by 0x53 0: Register bank 0 RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com 1: Register bank 1 RX_DR 6 0 R/W Data Ready RX FIFO interrupt Asserted when new data arrives RX FIFO Write 1 to clear bit. TX_DS 5 0 R/W Data Sent TX FIFO interrupt Asserted when packet transmitted on TX. If AUTO_ACK is activated, this bit is set high only when ACK is received. Write 1 to clear bit. MAX_RT R/W Maximum number of TX retransmits interrupt Write 1 to clear bit. If MAX_RT is asserted it must be cleared to enable further communication. RX_P_NO 3:1 111 R Data pipe number for the payload available for reading from RX_FIFO 000-101: Data Pipe Number 110: Not used 111: RX FIFO Empty TX_FULL 0 0 R TX FIFO full flag. 1: TX FIFO full 0: Available locations in TX FIFO
08 OBSERVE_TX Transmit observe register
PLOS_CNT 7:4 0000 R Count lost packets. The counter is overflow protected to 15, and discontinues at max until reset. The counter is reset by writing to RF_CH. ARC_CNT 3:0 0000 R Count retransmitted packets. The counter is reset when transmission of a new packet starts. 09 CD Reserved 7:1 000000 R CD 0 0 R Carrier Detect 0A RX_ADDR_P0 39:0 0xE7E7E 7E7E7 R/W Receive address data pipe 0. 5 Bytes maximum length. (LSB byte is written first. Write the number of bytes defined by SETUP_AW) 0B RX_ADDR_P1 39:0 0xC2C2C 2C2C2 R/W Receive address data pipe 1. 5 Bytes maximum length. (LSB byte is written first. Write the number of bytes defined by SETUP_AW) 0C RX_ADDR_P2 7:0 0xC3 R/W Receive address data pipe 2. Only LSB MSB bytes is equal to RX_ADDR_P1[39:8] 0D RX_ADDR_P3 7:0 0xC4 R/W Receive address data pipe 3. Only LSB MSB bytes is equal to RX_ADDR_P1[39:8] 0E RX_ADDR_P4 7:0 0xC5 R/W Receive address data pipe 4. Only LSB. MSB bytes is equal to RX_ADDR_P1[39:8] 0F RX_ADDR_P5 7:0 0xC6 R/W Receive address data pipe 5. Only LSB. MSB bytes is equal to RX_ADDR_P1[39:8] TX_ADDR 39:0 0xE7E7E 7E7E7 R/W Transmit address. Used for a PTX device only. (LSB byte is written first) Set RX_ADDR_P0 equal to this address to handle automatic acknowledge if this is a PTX device RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
11 RX_PW_P0
Reserved 7:6 00 R/W Only '00' allowed RX_PW_P0 5:0 000000 R/W Number of bytes in RX payload in data pipe 0 (1 to 32 bytes). 0: not used 1 = 1 byte 32 = 32 bytes
12 RX_PW_P1
Reserved 7:6 00 R/W Only '00' allowed RX_PW_P1 5:0 000000 R/W Number of bytes in RX payload in data pipe 1 (1 to 32 bytes). 0: not used 1 = 1 byte 32 = 32 bytes
13 RX_PW_P2
Reserved 7:6 00 R/W Only '00' allowed RX_PW_P2 5:0 000000 R/W Number of bytes in RX payload in data pipe 2 (1 to 32 bytes). 0: not used 1 = 1 byte 32 = 32 bytes
14 RX_PW_P3
Reserved 7:6 00 R/W Only '00' allowed RX_PW_P3 5:0 000000 R/W Number of bytes in RX payload in data pipe 3 (1 to 32 bytes). 0: not used 1 = 1 byte 32 = 32 bytes
15 RX_PW_P4
Reserved 7:6 00 R/W Only '00' allowed RX_PW_P4 5:0 000000 R/W Number of bytes in RX payload in data pipe 4 (1 to 32 bytes). 0: not used 1 = 1 byte 32 = 32 bytes
16 RX_PW_P5
Reserved 7:6 00 R/W Only '00' allowed RX_PW_P5 5:0 000000 R/W Number of bytes in RX payload in data pipe 5 (1 to 32 bytes). 0: not used 1 = 1 byte 32 = 32 bytes
17 FIFO_STATUS FIFO Status Register
Reserved 7 0 R/W Only '0' allowed TX_REUSE 6 0 R Reuse last transmitted data packet if set high. RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com The packet is repeatedly retransmitted as long as CE is high. TX_REUSE is set by the SPI command REUSE_TX_PL, and is reset by the SPI command W_TX_PAYLOAD or FLUSH TX TX_FULL 5 0 R TX FIFO full flag 1: TX FIFO full; 0: Available locations in TX FIFO TX_EMPTY R TX FIFO empty flag. 1: TX FIFO empty 0: Data in TX FIFO Reserved 3:2 00 R/W Only '00' allowed RX_FULL R RX FIFO full flag 1: RX FIFO full 0: Available locations in RX FIFO RX_EMPTY R RX FIFO empty flag 1: RX FIFO empty 0: Data in RX FIFO N/A ACK_PLD 255:0 X W Written by separate SPI command ACK packet payload to data pipe number PPP given in SPI command Used in RX mode only Maximum three ACK packet payloads can be pending. Payloads with same PPP are handled first in first out. N/A TX_PLD 255:0 X W Written by separate SPI command TX data pay-load register 1 - 32 bytes. This register is implemented as a FIFO with three levels. Used in TX mode only N/A RX_PLD 255:0 X R Read by separate SPI command RX data payload register. 1 - 32 bytes. This register is implemented as a FIFO with three levels. All RX channels share the same FIFO. 1C DYNPD Enable dynamic payload length Reserved 7:6 0 R/W Only „00‟ allowed DPL_P5 5 0 R/W Enable dynamic payload length data pipe 5. (Requires EN_DPL and ENAA_P5) DPL_P4 4 0 R/W Enable dynamic payload length data pipe 4. (Requires EN_DPL and ENAA_P4) DPL_P3 3 0 R/W Enable dynamic payload length data pipe 3. (Requires EN_DPL and ENAA_P3) DPL_P2 2 0 R/W Enable dynamic payload length data pipe 2. (Requires EN_DPL and ENAA_P2) DPL_P1 1 0 R/W Enable dynamic payload length data pipe 1. (Requires EN_DPL and ENAA_P1) DPL_P0 0 0 R/W Enable dynamic payload length data pipe 0. (Requires EN_DPL and ENAA_P0) 1D FEATURE R/W Feature Register Reserved 7:3 0 R/W Only „00000‟ allowed EN_DPL 2 0 R/W Enables Dynamic Payload Length EN_ACK_PAY 1 0 R/W Enables Payload with ACK EN_DYN_ACK 0 0 R/W Enables the W_TX_PAYLOAD_NOACK command Note: Don’t write reserved registers and registers at other addresses in register bank 0 Table 4 Register Bank 0 RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
7.2 Register Bank 1
(Hex) Mnemonic Bit Reset Value Type 00 31:0 0 W Must write with 0x404B01E2 01 31:0 0 W Must write with 0xC04B0000 02 31:0 0 W Must write with 0xD0FC8C02 31:0 03001200 W Must write with 0x99003941 31:0 W Must write with 0xD996821B(High Power) For single carrier mode:0xD99E8621 W RF output power in TX mode: 0:Low power(-30dB down) 1:High power 31:0 W Must write with 0x24067FA6(Disable RSSI) RSSI_TH 29:26 W RSSI Threshold for CD detect 0: -97 dBm, 2 dB/step, 15: -67 dBm RSSI_EN W RSSI measurement: 0:Enable 1:Disable 06 31:0 0 W Reserved 07 31:0 0 W Reserved RBANK R Register bank selection states. Switch register bank is done by SPI command “ACTIVATE” followed by 0x53 0: Register bank 0 1: Register bank 1 Chip ID 31:0 R BEKEN Chip ID: 0x00000063(RFM73P-S2) 09 0 Reserved 0A 0 Reserved 0B 0 Reserved 0C 31:0 0 Please initialize with 0x00731200 0D NEW_FEATURE 31:0 0 Please initialize with 0x0080B446 0E RAMP 87:0 NA W Ramp curve Please write with 0xFFFFFEF7CF208104082041 Note: Don’t write reserved registers and no definition registers in register bank 1 Table 5 Register Bank 1 RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
8 Electrical Specifications
Name Parameter (Condition) Min Typi cal Max Unit Comm ent Operating Condition VDD Voltage 3.3 3.6 4.2 V TEMP Temperature -40 +27 +85 ºC Digital input Pin VIH High level 0.7VDD 5.25 V VIL Low level VSS 0.3VDD V Digital output Pin VOH High level (IOH=-0.25mA) VDD- 0.3 VDD V VOL Low level(IOL=0.25mA) 0 0.3 V Normal condition IVDD Power Down current 3 uA IVDD Standby-I current 50 uA IVDD Standby-II current 400 uA Normal RF condition FOP Operating frequency 2400 2527 MHz FXTAL Crystal frequency 16 MHz RFSK Air data rate 1 2 Mbps Transmitter PRF Output power -20 20 22 dBm PBW Modulation 20 dB bandwidth(2Mbps) 2.5 MHz PBW Modulation 20 dB bandwidth (1Mbps) 1.3 MHz PRF1 Out of band emission 2 MHz -20 dBm PRF2 Out of band emission 4 MHz -40 dBm IVDD Current at + 20 dBm output power 180 200 mA Receiver IVDD Current (2Mbps) 21 30 mA IVDD Current (1Mbps) 20 30 mA Max Input 1 E-3 BER 10 dBm RXSENS 1 E-3 BER sensitivity (2Mbps) -85 dBm RXSENS 1 E-3 BER sensitivity (1Mbps) -88 dBm C/ICO Co-channel C/I (2Mbps) 4 dB C/I1ST ACS C/I 2MHz (2Mbps) -5 dB C/I2ND ACS C/I 4MHz (2Mbps) -20 dB C/I3RD ACS C/I 6MHz (2Mbps) -25 dB C/ICO Co-channel C/I (1Mbps) 4 dB C/I1ST ACS C/I 1MHz (1Mbps) 4 dB C/I2ND ACS C/I 2MHz (1Mbps) -18 dB C/I3RD ACS C/I 3MHz (1Mbps) -19 dB Table 6 Electrical Specifications RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
9 Typical Application Schematic
Figure 8 RFM73P-S2 typical application schematic RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com Figure 9 RFM73P-S2 SMD PACKAGE RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
11 Solder Information
Solder Method: Not supported reflow soldering, recommend to use hand solder . The Selection of Soldering tools The Selection of Soldering Materials According to both our soldering experiment and customers ’ feedback, we don’t find that it results in obvious effect on soldering and products ’ fuctions by using open soldering pens(i.e. common soldering pens without closed-loop temperature control). However, considering the requirements of lead -free soldering and its productivity improvement, we suggest that you should use thermostatic soldering pen with closed-loop temperature control and select appropriate solder t ip. Please kindly note that big solder tips, according to the feedback from customers, obviously bring about low efficiency of soldering and increase the possibility of short - circuit. ——Sn96.5%/Ag3.0%/Cu0.5% ——Sn96.5%/Ag3.5% The wireless modules we provide are green products in complete accordance with the lead -free requirement; therefore, we suggest you should use environment -friendly lead -free soldering tin. We recommend two alloyed soldering tins as below to match the no - clean rosin(core and additive rosin): ——Sn96.5%/Ag3.0%/Cu0.5% ——Sn96.5%/Ag3.5% RFM73P-S2 V2.0
Tel: +86-755-82973805 Fax: +86-755-82973550 E -mail: sales@hoperf.com http://www.hoperf.com
12 Contact Information
HOPE MICROELECTRONICS CO.,LTD Add: 2 /F, Building 3, Pingshan Private Enterprise Science and Technology Park, Lishan Road, XiLi Town, Nanshan District, Shenzhen, Guangdong, China Tel: 86-755-82973805 Fax: 86-755-82973550 Email: sales@hoperf.com Website: http://www.hoperf.com http://www.hoperf.cn This document may contain preliminary information and is subject to change by Hope Microelectronics without notice. Hope Microelectronics assumes no responsibility or liability for any use of the information contained herein. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Hope Microelectronics or third parties. The products described in this document are not intended for use in implantation or other direct life support applications where malfunction may result in the direct physical harm or injury to persons. NO WARRANTIES OF ANY KIND, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MECHANTABILITY OR FITNESS FOR A ARTICULAR PURPOSE, ARE OFFERED IN THIS DOCUMENT. ©2006, HOPE MICROELECTRONICS CO.,LTD. All rights reserved. RFM73P-S2 V2.0