RES-90 COOPER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Features

  • Designed without multiple links for easy fuse link replacement.
  • These fuses are generally sized at the amp rating of non-inductive circuits and 300% for motor circuits. Recommended fuse blocks Part Number Description H250 Series 250V, 30A & 60A 1-, 2- and 3-pole open fuse blocks H600 Series 600V, 30A & 60A 1-, 2 and 3-pole open fuse blocks For details, see data sheet # 1112 for the H250 Series and data sheet # 1113 for the H600 Series.

REN (250V) & RES (600V) Renewable Class H Fuses www.bussmann.com Dimensions - in Replacement 250V REN & 600V RES fuse links 250V LKN Fuse link catalog numbers (amps) LKN-1 LKN-10 LKN-60 LKN-200 LKN-1-1/2 LKN-12 LKN-70 LKN-225 LKN-2 LKN-15 LKN-75 LKN-250 LKN-3 LKN-20 LKN-80 LKN-300 LKN-4 LKN-25 LKN-90 LKN-350 LKN-5 LKN-30 LKN-100 LKN-400 LKN-6 LKN-35 LKN-110 LKN-450 LKN-7 LKN-40 LKN-125 LKN-500 LKN-8 LKN-45 LKN-150 LKN-600 LKN-9 LKN-50 LKN-175 -— 250V LKN Fuse link carton quantity and weight Catalog Number Carton Qty Weight Lbs (kg)* LKN 1–30 20 0.05 (0.02) LKN 35–60 20 0.20 (0.09) LKN 70–100 10 0.20 (0.09) LKN 110–200 5 0.25 (0.11) LKN 225–400 5 0.55 (0.25) LKN 450–600 2 0.32 (0.15) *Weight per carton. 600V LKS Fuse link catalog numbers (amps) LKS-1 LKS-10 LKS-50 LKS-200 LKS-2 LKS-12 LKS-60 LKS-225 LKS-2-1/2 LKS-15 LKS-70 LKS-250 LKS-3 LKS-17-1/2 LKS-80 LKS-300 LKS-4 LKS-20 LKS-90 LKS-350 LKS-5 LKS-25 LKS-100 LKS-400 LKS-6 LKS-30 LKS-110 LKS-450 LKS-7 LKS-35 LKS-125 LKS-500 LKS-8 LKS-40 LKS-150 LKS-600 LKS-9 LKS-45 LKS-175 — 600V RES Fuse link carton quantity and weight Catalog Number Carton Qty Weight Lbs (kg)* LKS 1–30 20 0.05 (0.02) LKS 35–60 20 0.02 (0.09) LKS 65–100 10 0.02 (0.09) LKS 110–200 5 0.25 (0.11) LKS 225–400 5 0.55 (0.25) LKS 450–600 2 0.32 (0.15) *Weight per carton. 1A to 30A 0.56" 35A to 60A 0.81" 1.06"5.5" 35A to 60A1A to 30A 0.81"5" 250V REN 600V RES

REN (250V) & RES (600V) Renewable Class H Fuses Technical Data 1028 Effective March 2014 www.bussmann.com Time-current characteristic curves – average melt 250V REN (LKN Fuse links)

REN (250V) & RES (600V) Renewable Class H Fuses Technical Data 1028 Effective March 2014 Time-current characteristic curves – average melt 600V RES (LKS Fuse links) www.bussmann.com

REN (250V) & RES (600V) Renewable Class H Fuses Technical Data 1028 Effective March 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners. Eaton’s Bussmann Business 1 14 Old State Road Ellisville, MO 63021 United States www.bussmann.com © 2014 Eaton All Rights Reserved Publication No. 1028 — BU-SB14109 March 2014 The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.