RER220-43 EBMPAPST | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 13
Technical content
Product Data Sheet RER220-43/18/2TDMO
Product Data Sheet RER220-43/18/2TDMO 06/23/2015 page 2 of 13 RER220-43/18/2TDMO INDEX
Product Data Sheet RER220-43/18/2TDMO 06/23/2015 page 3 of 13
1 General
Fan type Blower without cha ssis with intake nozzle Rotational direction looking at rotor clockwise Airflow direction Air in axially, Air out radially Bearing system Ball bearing Mounting position any
2 Mechanics
2.1 General
Weight 0,89 kg Housing material Impeller material Plastic
2.2 Connections
Electrical connection Wires Length of lead wire L = 425 mm Tolerance +- 10,0 mm Length of tube S = 135 mm Tolerance +- 5 mm Wire gauge (AWG) 22 Insulation diameter 1,35 mm Colour Operation Wire 1 red + UB Wire 2 blue - GND Wire 3 violet CONTR Wire 4 white Tacho The auxilliaries shown on the schematic diagram (which are required for the intended use) are not part of our delivery. Lead wire 1 - 2: AWG22 Lead wire 3 - 4: AWG22 (Insulation diameter 1,35mm)
Product Data Sheet RER220-43/18/2TDMO 06/23/2015 page 4 of 13
3 Operating Data
3.1 Operating Data - Electrical Interface - Input
Features
PWM - Frequency 1 kHz - 10 kHz Typical: 2 kHz Inpute voltage range 0 V - 10 V Characteristics
Product Data Sheet RER220-43/18/2TDMO 06/23/2015 page 5 of 13 Schematics Input voltage divider: R1 = 47 kOhm R2 = 36 kOhm For protection: There is parallel to R2 a 5,1 V Z-Diode Speed control: By pulse-width modulation (PWM) 0 ... 100% with switching transistor in emitter circuit and collector resistance to 12 V Frequency = 2 kHz (1 - 10 kHz) Information to the curve PWM: 0% - <10% PWM: 0 1/min 10% PWM: 800 1/min (Fan on, comming from 0% PWM) 10% - 13% PWM: 800 1/min (corresponding to min. speed) 13% - 78% PWM: linear increasing curve 78% - 100% PWM: 3000 1/min (cor responding to max. speed) 10% - >8% PWM: linear decreasing curve (comming from 100% PWM) 8% PWM: 600 1/min or 0 1/min (Fan off, comming from 100% PWM) oder:
Product Data Sheet RER220-43/18/2TDMO 06/23/2015 page 6 of 13 Speed control: By analog voltage 0 - 10 V Information to the curve analog:
0 V - < 1,3 V: 0 1/min
1,3 V: 800 1/min (Fan on, comming from von 0 V) 1,3 V - 1,6 V: 800 1/min (corresponding to min. speed) 1,6 V - 9,4 V: linear increasing curve 9,4 V - 10 V: 3000 1/min (corresponding to max. speed) 1,3 V - > 1,0 V: linear decreasing curve (comming from 10 V) 1,0 V: 600 1/min or 0 1/min (Fan off, comming from 10 V) All values are measured in the housing! Fan doesn't have a sensor break detection!
Product Data Sheet RER220-43/18/2TDMO 06/23/2015 page 7 of 13
3.2 Electrical Operating Data
conditions: Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal; warm-up time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area should not be any solid obstruction within 0,5 m. Measurement setup: Measured between two steel plates Steel plate: 225 mm x 225 mm Intake nozzle: D: 155 mm; R: 25 mm Distance between bottom and top plate: 90 mm Overlapping impeller / nozzle: 2 mm ∆p = 0: corresp. to free ai r flow (see section 3.5) I: corresp. to arithm. mean current value Name Condition U Contr. 0001 U Contr.: 10 V Features Condition Symbol Values Voltage range ∆p = 0 U 36,0 V 72,0 V Nominal voltage ∆p = 0 U N 48,0 V Power consumption ∆p = 0 U Contr. 0001 P 102,9 W 109,4 W 107,3 W Current consumption ∆p = 0 U Contr.0001 I 2.860 mA 2.280 mA 1.490 mA Speed ∆p = 0 U Contr. 0001 n 2.970 1/min 3.000 1/min 3.000 1/min Tolerance +- 7,5 % +- 5,0 % +- 5,0 % Starting current consumption 3.000 mA max. allowed input voltage ripple (within the specified voltage range) +- 3 % max. allowed input voltage ripple (within the specified voltage range) >= 50 Hz Name Condition U Contr. 0002 U Contr.: 5 V Features Condition Symbol Values Voltage range ∆p = 0 U 36,0 V 72,0 V Nominal voltage ∆p = 0 U N 48,0 V Power consumption ∆p = 0 U Contr. 0002 P 21,9 W 24,9 W 23,8 W Current consumption ∆p = 0 U Contr. 0002 I 610 mA 520 mA 330 mA Speed ∆p = 0 U Contr. 0002 n 1.770 1/min 1.800 1/min 1.800 1/min Tolerance +- 7,5 % +- 5,0 % +- 5,0 % The data at 5V are no FK features and need not be tested.
3.3 Operating Data - Electrical Interface -Output
Product Data Sheet RER220-43/18/2TDMO 06/23/2015 page 8 of 13 Tacho type /2 (Open collector) Features Note Values Tacho operating voltage (UBS) <= 60 V Tacho signal Low I sink: 2 mA <= 0,4 V Tacho signal High I source: 0 mA <= 60 V Maximum sink current <= 20 mA External resistor External resistor Ra from UBS to US required. All voltages measured to GND. Tacho frequency (3 x n) / 60 150 Hz Tacho isolated from motor No Slew rate => 0,5 V/us Please note: At zero speed the tacho signal is at a static HIGH. It will be also HIGH when the fan is still spinning, but the speed control signal is set to zero speed already. The tacho signal is only activated after the start-up is completed. Alarm type None
3.4 Electrical Features
Electronic function Speed-Controlled Reversed polarity protection P-CH FET Max. residual current at Un IF <= 5 mA Locked rotor protection Auto restart Locked rotor current at Un approx. 3.000 mA Clock signal t3/t4 at locked rotor Typical: 7,8 s / 10 s
Product Data Sheet RER220-43/18/2TDMO 06/23/2015 page 9 of 13 Locked rotor signal t5 50s: After 2 failed start-ups there is an extended timeout of 50 s.
3.5 Data according ErP directive
Installation / Efficency category A / static Speed control integrated Specific ratio 1,00394 Target overall efficiency 2015 42,3 % Overall efficiency 54,0 % Efficiency grade 62 Power input 132,6 W Speed 2.970 1/min All values measured in optimum energy efficiency point. Productiondatecode is printed on the fan label.
3.6 Aerodynamic
conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; In the intake and outlet area should not be any solid obstruction within 0,5 m. The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions. Measurement setup: Measured between two steel plates Steel plate: 225 mm x 225 mm Intake nozzle: D: 155 mm; R: 25 mm Distance between bottom and top plate: 90 mm Overlapping impeller / nozzle: 2 mm a.) Operation condition: 3.000 1/min at free air flow U Contr. 10 V Max. free-air flow (∆p = 0 / = max.) 1.063,0 m3/h Max. static pressure (∆p = max. / =0) 525 Pa
Product Data Sheet RER220-43/18/2TDMO 06/23/2015 page 10 of 13
Product Data Sheet RER220-43/18/2TDMO 06/23/2015 page 11 of 13
4 Environment
4.1 General
Min. permitted ambient temperature TU min. -20 °C Max. permitted ambient temperature TU max. 55 °C Min. permitted storage temperature TL min. -40 °C Max. permitted storage temperature TL max. 80 °C
4.2 Climatic requirements *)
Humidity requirements humid heat, c onstant; according to DIN EN 60068-2- 78, 14 days Water exposure None Dust requirements None Salt fog requirements None *) Permittet application area: The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided. Pollution degree 1 (according DIN EN 60664-1) There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.
Product Data Sheet RER220-43/18/2TDMO 06/23/2015 page 12 of 13
5 Safety
5.1 Electrical Safety
DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25°C. No arcing or breakdown is allowed! All connections together to ground. 1000 VAC / 1 Min. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. 1000 VAC / 1 Sec. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25°C measured with U=500 VDC for 1 min. RI > 10 MOhm clearance / creepage distance 1,0 mm / 1,5 mm Protection class I
5.2 Approval Tests
CE EC Declaration of Conformity No EAC Eurasian Conformity Yes UL Underwriters Laboratories Yes / UL507, Electric Fans VDE Association for Electrical, Electronic and Information Technologies Yes / Approval acc. to EN 60950 (VDE 0805) - Information technology equipment CSA Canadian Standards Association Yes / CSA audited by UL according to C22.2 No. 113 Fans and Ventilators CCC China Compulsory Certification No
6 Reliability
6.1 General
Life expectancy L10 at TU = 40 °C 65.000 h Life expectancy L10 at TU max. 45.000 h