70 Watt Open Frame Switching Power Supply with PFC REL70 series

WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458

70 Watts Output Power

1, 2, 3, and 4 Outputs Active Power Factor Correction 2.5VDC to 48VDC Outputs Model Number Output #1 Output #2 Output #3 Output #4 SINGLE OUTPUT REL70-1001 2.5V/14A REL70-1002 3.3V/14A REL70-1003 5V/14A REL70-1004 12V/5.8A REL70-1005 15V/4.7A REL70-1006 24V/2.9A REL70-1007 28V/2.5A REL70-1008 48V/1.5A DUAL OUTPUT REL70-2001 3.3V/6A 5V/5A REL70-2002 5V/6A 12V/4A REL70-2003 5V/6A 24V/2A REL70-2004 12V/3A -12V/3A REL70-2005 15V/3A -15V/2A TRIPLE OUTPUT REL70-3001 5V/6A 12V/2A -12V/2A REL70-3002 5V/6A 15V/2A -15V/2A QUAD OUTPUT REL70-4001 3.3V/6A 5V/5A 12V/2A -12V/2A REL70-4002 5V/6A 3.3V/5A 12V/2A -12V/2A REL70-4003 5V/6A 3.3V/5A 15V/2A -15V/2A REL70-4004 5V/6A -5V/5A 12V/2A -12V/2A REL70-4005 5V/6A -5V/5A 15V/2A -15V/2A REL70-4006 5V/6A 24V/2A 12V/2A -12V/2A REL70-4007 5V/6A 24V/2A 15V/2A -15V/2A Medical Versions Available Contact Factory

WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 INPUT SPECIFICATIONS Input Voltage, Full Range: 85-264 VAC Active PFC >0.95@115VAC Input Frequency 47-63Hz. Inrush Current 30A @ 115VAC, typ 4 40A @ 230VAC, typ 4 Leakage Current <300uA @ 240VAC OUTPUT SPECIFICATIONS Output Power 50W, Conv/70W Forced Air Minimum Load Requirement 10% Max Current (A, Peak) See Model Selection Chart 7 Initial Accuracy +/-1%, typ Voltage Adjust ± 8%, typ Load Regulation ± 1%, typ Cross Regulation +/-5% Line Regulation ± 0.5%, typ Temperature Coefficient ± 0.02%/°C Ripple/Noise 100mV Pk-Pk, typ Overvoltage Protection 110-150%, Type 2 & 3 Remote Sense (Singles Only) 250mV compensation Hold Up/Start Up Times 16mS/4Sec, typ Short Circuit Protection Continuous 4 Current Limit 110-160% typ, Auto Recovery GENERAL SPECIFICATIONS Input-Output Isolation 3000VAC 5 Output-Ground Isolation 500VAC Input-Ground Isolation 1500VAC Efficiency (@ Full Load) 78%, typ (or See Chart/Curve) Safety UL60950/EN60950 Approved EMC EN55022/B, EN61000-3-2,3/A ENVIRONMENTAL SPECIFICATIONS Oper. Temperature 0 to +60 °C 4 Relative Humidity 10-95%, Description 4 Storage Temperature -40 to +85 °C 4 MTBF 100KHrs MIL-Std 217F Shock & Vibration To MIL-Std 810E PHYSICAL SPECIFICATIONS Dimensions 4.5”x2.5”x1.22” Material Flammability to UL94V-0 Construction Open Frame Weight 0.6lb SPECIFICATION NOTES 1) All specifications typical @ 25°C, Nominal Line & Load, unless otherwise noted. 2) O/P noise measured directly at pins/terminals with 0.1uFbypass, pk-pk @ 20MHz bandwidth. 3) Ripple and Noise dependant upon output voltage as specified per particular model. 4) These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed or implied. 5) Isolation for up to 1 minute duration. 6) No termination necessary with control pin to maintain constant “ON” operation (if applicable to this model) 7) Max load (peak) specified for 10mS max, 20% duty cycle, minimum load on all outputs A Blue Number means see respective Specification All specifications are typical at nominal input, full load, and 25DegC unless otherwise noted

WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 MECHANICAL DIMENSIONS THERMAL PERFORMANCE 1 – Optimum2 – Good3 – Good4 - Fair RECOMMENDED AIR FLOW DIRECTION OPEN FRAME MULTIPLE OUTPUT MODEL SINGLE OUTPUT MODEL 1.22 (30.9) 1 .128 DIA 1.00 (25.4) (4 PLACES) MTG HOLE O O O O O O (+) (+)8 (+) (-) (+) O O (-) (-) (-) GND INPUT AC N L AC INPUT GND L N MAX .80 (20.3) 2.20 (55.9) 2.50 (63.5) 4.50 (114.3) SENSE(+)2 (-) 6( +) (-) (-) P.F. RTN P.F. SIG OUTPUT 1 SENSE 1( +) OUTPUT 1 1( -) (+)P .F. SIG P.F. RTN 6( +) 7( -) (+) (+)2 (-) (+) (-) 1( -) OUTPUT 2 OUTPUT 1 OUTPUT 1 OUTPUT 4 OUTPUT 3 OUTPUT 3 OUTPUT 2 OUTPUT 4 V1 ADJUST V1 ADJUST CHASSIS & COVER 4.20 (106.7) MTG HOLE (2 PLACES) 4-40 1.48 (37.6) .68 (17.2) 2.20 (55.9) 2.62 (66.5) MTG HOLE (4 PLACES-BASE) 4-40 4.79 (121.6) 4.20 (106.7) ALL DIMENSIONS IN INCHES (MM) 01 02 03 04 05 06 07 0 CONVECTION COOLING CONVECTION COOLING WITH CHASIS / COVER FORCED AIR COOLING CONVECTION COOLING CONVECTION COOLING WITH CHASIS / COVER FORCED AIR COOLING CONNECTOR SPECIFICATIONS P1 AC Input .156 friction lock header mates with Molex 09-50-3031 crimp terminal housing with Molex 2478 crimp terminal P2 DC Output (Single) .156 friction lock header mates with Molex 09-50-3181 crimp terminal housing with Molex 2478 crimp terminal P2 DC Output (Multiple) .156 friction lock header mates with Molex 09-50-3181 crimp terminal housing with Molex 2478 crimp terminal G Ground .187 quick disconnect terminal P3 P.F Sense (Single) .100 breakaway header mates with Molex 22-55-2061 crimp terminal housing with Molex 71851crimp terminal P3 Power Fail (Multiple) .100 breakaway header mates with Molex 50-57-9002 crimp terminal housing with Molex 71851 crimp terminal