Features

  • High ESD withstand Voltage: +/-24kV (Contact) & +/- 30kV (Air) per IEC 61000-4-2
  • High EOS Surge capability
  • Low ESD clamping voltage
  • Working voltage: 5V
  • Low capacitance: 1.1 pF Typical (I/O to GND)
  • Low dynamic resistance: 0.25Ω
  • Solid-state silicon-avalanche technology Mechanical Characteristics
  • SC-70 6L package
  • Pb-Free, Halogen Free, RoHS/WEEE compliant
  • Nominal Dimensions: 2.1 x 2.0 x 1.0 mm
  • Lead Finish: Matte Tin
  • Marking: Marking code
  • Packaging: Tape and Reel

Applications

  • Monitors and Flat Panel Displays
  • Analog Video Lines
  • LVDS Lines
  • USB 2.0
  • SIM Ports RClamp0504FB Low Capacitance RClamp® 5V TVS for ESD & EOS Protection

Description

RClamp® TVS diodes are designed to protect sensitive electronics from damage or latch-up due to transient surge events. This device offers desirable characteristics for board level protection including fast response time, low operating and clamping voltage, and no device degradation. RClamp®0504FB features extremely good ESD and EOS protection characteristics highlighted by low dynamic resistance and high surge capability. Data (I/O) lines are protected from EOS surge events as high as 14A (tp = 8/20μs). Power buses may subjected to even harsher EOS events. The TVS connection at pin 5 allows protection of VBus lines to 28A (tp = 8/20μs). RClamp0504FB is in a 6-pin, SC-70 6L package. The leads are finished with lead-free matte tin. The combination of small size, low capacitance, and high ESD and EOS surge capability makes them ideal for use in applications such as USB 2.0, multimedia cards, and video interfaces. 1 3 4 6 Circuit Diagram Schematic & Pin Configuration SC-70 6L (Top View) PROTECTION PRODUCTS

Final Datasheet Rev 2.1 Revision Date 2/20/2019 www.semtech.com 2 of 7 Semtech Proprietary and Confidential Absolute Maximum Rating Rating Symbol Value Units Peak Pulse Power (I/O Pins, tp = 8/20µs) PPK 230 W Peak Pulse Power (VBus Pin, tp = 8/20µs) PPK 500 W Peak Pulse Current (I/O Pins, tp = 8/20µs) IPP 14 A Peak Pulse Current (VBus Pin, tp = 8/20µs) IPP 28 A ESD per IEC 61000-4-2 (Air)(1) ESD per IEC 61000-4-2 (Contact)(1) VESD ±30 ±24 kV Operating Temperature TJ -55 to +125 OC Storage Temperature TSTG -55 to +150 OC Electrical Characteristics (T=25OC unless otherwise specified) Parameter Symbol Conditions Min. Typ. Max. Units Reverse Stand-Off Voltage VRWM Any pin to Pin 2 5 V Reverse Breakdown Voltage VBR IBR = 1mA, any I/O Pin to Pin 2 6 8.5 10 V Reverse Leakage Current IR VRWM = 5V, any I/O Pin to Pin 2 0.1 μA Clamping Voltage VC tp = 8/20μs (Any I/O Pin to Pin 2 ) IPP = 14A 13.7 16.5 V tp = 8/20μs (Pin 5 to Pin 2 ) IPP = 28A 15.5 17.5 ESD Clamping Voltage2 VC tp = 0.2/100ns (Any I/O Pin to Pin 2) IPP = 4A 10.5 V IPP = 16A 13.5 Dynamic Resistance2,3 RDYN tp = 0.2/100ns, Any I/O Pin to Pin 2 0.25 Ω Junction Capacitance CJ VR = 0V, f = 1MHz Any I/O Pin to Pin 2 1.1 2.5 pF Between I/O pins 0.55 1.5 Notes 1) Measured with a 40dB attenuator, 50 Ohm scope input impedance, 2GHz bandwidth. ESD gun return path connected to ESD ground plane. 2) Transmission Line Pulse Test (TLP) Settings: tp = 100ns, tr = 0.2ns, ITLP and VTLP averaging window: t1 = 70ns to t2 = 90ns. 3) Dynamic resistance calculated from ITLP = 4A to ITLP = 16A

Final Datasheet Rev 2.1 Revision Date 2/20/2019 www.semtech.com 3 of 7 Semtech Proprietary and Confidential Typical Characteristics Non Repetitive Peak Pulse Power vs. Pulse Time Power Derating Curve ESD Clamping (8kV Contact per IEC 61000-4-2) (Pins 1, 3, 4, 6) Clamping Voltage vs. Peak Pulse Current (tp=8/20µs) -40 -20 100 120 140 -10 10 30 50 70 Clamping Voltage (V) Time (ns) TA = 25OC. Waveform IEC61000-4-2 8kV contact discharge. Measured with and corrected for 50Ω, 40dB Attenuator. 50Ω Scope Input Impedance, ≥2GHz BW. ESD Gun Return connected to ESD Ground Plane. 0 5 10 15 20 25 30 35 Clamping Voltage-VC (V) Peak Pulse Current - IPP (A) TA = 25OC Pins 1, 3, 4, 6 Pin 5 -250 -200 -150 -100 -50 -10 10 30 50 70 Clamping Voltage (V) Time (ns) TA = 25OC. Waveform IEC61000-4-2 -8kV contact discharge. Measured with and corrected for 50Ω, 40dB Attenuator. 50Ω Scope Input Impedance, ≥2GHz BW. ESD Gun Return connected to ESD Ground Plane. 0.5 1.5 2.5 0 1 2 3 4 5 6 Junction Capacitance-CJ (pF) Reverse Voltage -VR (V) f = 1 MHz 0.01 0.1 0.1 1 10 100 1000 Peak Pulse Power - PPP (kW) Pulse Duration - tp (µs) DR040412-240 TA = 25OC VBus Data (I/O) Lines 100 120 0 25 50 75 100 125 150 % of Rated Power or IPP Ambient Temperature - TA (OC) DR040512:25:125:150 ESD Clamping (-8kV Contact per IEC 61000-4-2) (Pins 1, 3, 4, 6) Capacitance vs. Reverse Voltage (Pins 1, 3, 4, 6 to Pin 2)

Final Datasheet Rev 2.1 Revision Date 2/20/2019 www.semtech.com 4 of 7 Semtech Proprietary and Confidential Typical Characteristics (Continued) Positive TLP Characteristic (Pins 1, 3, 4, 6) Negative TLP Characteristic (Pins 1, 3, 4, 6) Insertion Loss (I/O Pins 1, 3, 4, 6) Insertion Loss (I/O Pin to I/O Pin) 1 10 100 1000 Insertion Loss - IL (dB) Frequency (MHz) 1 10 100 1000 Insertion Loss - IL (dB) Frequency (MHz) 0 2 4 6 8 10 12 14 16 18 TLP Current (A) TLP Voltage (V) Transimission Line Pulse (TLP) Settings: tp= 100ns, tr=0.2ns, ITLP and VTLP averaging window: t1=70ns to t2=90ns -30 -25 -20 -15 -10 TLP Current (A) TLP Voltage (V) Transimission Line Pulse (TLP) Settings: tp= 100ns, tr=0.2ns, ITLP and VTLP averaging window: t1=70ns to t2=90ns Analog Crosstalk -100 -80 -60 -40 -20 10 100 1000 Analog Crosstalk (dB) Frequency (MHz)

Final Datasheet Rev 2.1 Revision Date 2/20/2019 www.semtech.com 5 of 7 Semtech Proprietary and Confidential Outline Drawing - SC70 6L Land Pattern - SC70 6L DETAILSEE DETAILA 1 2 N 0.10 1.25 2.20

2.10 BSC

0.65 BSC

1.15 2.00 0.15 1.35 0.30- PLANE GAGE 1.80 0.10 0.30 0° - 8° 0.90 (0.42) 0.360.26 0.08 0.00 0.70 0.22 0.46 0.10 1.10 1.00

1.30 BSC

A 3. DIMENSIONS "E1" AND "D" DO NOT INCLUDE MOLD FLASH, PROTRUSIONS OR GATE BURRS. -B- CONTROLLING DIMENSIONS ARE IN MILLIMETERS (ANGLES IN DEGREES). DATUMS AND TO BE DETERMINED AT DATUM PLANE NOTES: 2. -A- -H- SIDE VIEW DIM bbb ccc e aaa N L c E D b A MILLIMETERS NOM DIMENSIONS MIN MAX H 0.15 A E1 E D E/2 e B ccc C 2X N/2 TIPS D SEATING aaa C PLANE C A1 A2 A bxN bbb C A-B D L (L1) c X G Z Y P (C) .033 .106 .039 (.073) .026 .016 1.00 (1.85) 0.65 0.40 0.85 2.70 NOTES: INCHES Y Z DIM G P X C MILLIMETERS DIMENSIONS Y Z G P X C CONTROLLING DIMENSIONS ARE IN MILLIMETERS (ANGLES IN DEGREES). THIS LAND PATTERN IS FOR REFERENCE PURPOSES ONLY. CONSULT YOUR MANUFACTURING GROUP TO ENSURE YOUR COMPANY'S MANUFACTURING GUIDELINES ARE MET.

Final Datasheet Rev 2.1 Revision Date 2/20/2019 www.semtech.com 6 of 7 Semtech Proprietary and Confidential Marking Code 0504F YYWW Tape and Reel Specification

Ordering Information

Part Number Qty per Reel Reel Size RClamp0504FBTCT 3,000 7” 0504F YYWW Pin 1 Location User Direction of feed 0504F YYWW 0504F YYWW

Final Datasheet Rev. 2.1 Revision date 2/20/2019 7 of 7 Semtech Proprietary and Confidential Contact Information Semtech Corporation

200 Flynn Road, Camarillo, CA 93012

Phone: (805) 498-2111, Fax: (805) 498-3804 www.semtech.com IMPORTANT NOTICE Information relating to this product and the application or design described herein is believed to be reliable, however such information is provided as a guide only and Semtech assumes no liability for any errors in this document, or for the application or design described herein. Semtech reserves the right to make changes to the product or this document at any time without notice. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. Semtech warrants performance of its products to the specifications applicable at the time of sale, and all sales are made in accordance with Semtech’s standard terms and conditions of sale. SEMTECH PRODUCTS ARE NOT DESIGNED, INTENDED, AUTHORIZED OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT APPLICATIONS, DEVICES OR SYSTEMS, OR IN NUCLEAR APPLICATIONS IN WHICH THE FAILURE COULD BE REASONABLY EXPECTED TO RESUL T IN PERSONAL INJURY , LOSS OF LIFE OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. INCLUSION OF SEMTECH PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE UNDERTAKEN SOLELY AT THE CUSTOMER’S OWN RISK. Should a customer purchase or use Semtech products for any such unauthorized application, the customer shall indemnify and hold Semtech and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs damages and attorney fees which could arise. The Semtech name and logo are registered trademarks of the Semtech Corporation. All other trademarks and trade names mentioned may be marks and names of Semtech or their respective companies. Semtech reserves the right to make changes to, or discontinue any products described in this document without further notice. Semtech makes no warranty, representation or guarantee, express or implied, regarding the suitability of its products for any particular purpose. All rights reserved. © Semtech 2019