RBQ-12-33-D48 MURATA-PS | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 15
Technical content
www.murata-ps.com www.murata-ps.com/support For full details go to www.murata-ps.com/rohs Ḥ Figure 1. Connection Diagram recommends an external fuse at F1.
FEATURES
386 Watts total output power, 11.7 VDC @ 33 A Regulated Intermediated Bus Architecture (RIBA) with PoL converters 96% ultra-high effi ciency at full load (typical) 36 to 75 Volt DC input range (48 VDC nominal) Standard quarter-brick footprint Synchronous rectifi er topology with 100 mV ripple & noise Up to +85° Celsius thermal performance (with derating) Stable no-load operation Multiple-unit parallel operation for increased current Fully isolated to 2250 VDC (BASIC) Remote On/Off enable control Extensive protection features – SC, OC, UVLO, OT Certifi ed to full safety, emissions and environ- mental standards Approved to UL 60950-1, CAN/CSAC22.2 No. 60950-1, IEC60950-1, EN60950-1 safety ap- provals (2nd Edition, with Amendment 1) PRODUCT OVERVIEW The fully isolated (2250 Vdc) RBQ-12/33-D48xB-C module accepts a 36 to 75 Volt DC input voltage range (48 VDC nominal) and converts it to a low Vdc output. Applications include 48V-powered datacom and telecom installations, base stations, cellular dataphone repeaters, instruments and embedded systems. Wideband output ripple and noise is a low 100 mV, peak-to-peak. The RBQ’s synchronous-rectifi er topology with line regulation and fi xed frequency operation means excellent effi ciencies up to 96%, enabling “no heatsink” operation for most applications up to +85° Celsius (with derating airfl ow). “No fan” or zero airfl ow higher temperature applications may use the optional base plate for cold surface mount- ing or natural-convection heatsinks. A wealth of electronic protection features include input undervoltage lockout (UVLO) , output current limit, short circuit hiccup, and overtemperature shutdown. Available options include positive or negative logic remote On/Off control, conformal coating, and various pin lengths. Assembled using ISO-certifi ed automated surface-mount techniques, the RBQ series is certifi ed to all UL and IEC emis- sions, safety and fl ammability standards. Typical unit External DC Power Source Reference and Error Amplifier t4XJUDIJOH t'JMUFST t$VSSFOU4FOTF -Vout (4) +Vout (8) On/Off Control (2) -Vin (3) Open = On $MPTFE 0GG +Vin (1) 1PTJUJWF MPHJD Controller and Power 5SBOTGFS Duty Cycle 3FHVMBUJPO *TPMBUJPO Barrier Output (Vout, typ) Current (A) Nominal Input (V) 11.7 33 48
www.murata-ps.com/support PART NUMBER STRUCTURE RBQ-12/33-D48xB-C Quarter-Brick 400-Watt Isolated DC-DC Converters MDC_RBQ-12/33-D48.A07 Δ Page 2 of 15 Maximum Rated Output Current in Amps Maximum Output Voltage (11.85V) - / D48- Output Confi guration RB = Regulated Converter RB N B Quarter-Brick Package Isolated converter Q Input Voltage Range D48 = 36-75V, 48V nominal PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE Root Model ➀ Output Input Effi- ciency DimensionsVOUT (V, typ) IOUT (A, typ) Total Power (W, typ) Ripple & Noise (mVp-p) Regulation (max.) ➁ VIN Nom. (V) Range (V) IIN, min. load (mA) IIN, full load (A)Typ. Max. Line (%) Load (%) Typ. (inches) (mm) ➀ Please refer to the part number structure for additional options and complete ordering part numbers. ➁ Regulation specifi cations describe the output voltage deviations as the line voltage or load current is varied from its nominal/midpoint value to either extreme. (Load step = ±25 %). Line Regulation tested from 40V to 75V, output @nominal load. ➂ All specifi cations are at nominal line voltage and full load, +25 deg.C. unless otherwise noted. See detailed specifi cations. Output capacitors are 1μF, 10uF and 470μF in parallel, with a 220μF input capacitor. I/O caps are necessary for our test equipment and may not be needed for your application. HS Conformal coating (optional) Blank = no coating, standard H = Coating added, optional ➀ Load Share Option Blank = no share S = Load share RoHS Hazardous Materials compliance C = RoHS 6 (does not claim EU RoHS exemption 7b–lead in solder), standard On/Off Control Logic Option N = Negative logic P = Positive logic Baseplate B = Baseplate installed, standard NOTE: This product is not available without the baseplate. Lx ( Through-hole packages only) Blank = Standard pin length 0.180 inches (4.6mm) L1 = Pin length 0.110 inches (2.79mm) ➀ L2 = Pin length 0.145 inches (3.68mm) ➀ Pin Length Option 12 33 ➀ Special quantity order is required; samples available with standard pin length only. ➁ Some model number combinations may not be available. See website or contact your local Murata sales representative.
www.murata-ps.com/support RBQ-12/33-D48xB-C Quarter-Brick 400-Watt Isolated DC-DC Converters MDC_RBQ-12/33-D48.A07 Δ Page 3 of 15 FUNCTIONAL SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS Conditions ➀ Minimum Typical/Nominal Maximum Units Input Voltage, Continuous Full power operation 0 80 Vdc Input Voltage, Transient Operating or non-operating, 100 mS max. duration 0 100 Vdc Isolation Voltage Input to output, 100 mS to IEC/EN/UL 60950-1 2250 Vdc On/Off Remote Control Power on or off, referred to -Vin 0 15 Vdc Output Power 0 391 W Output Current Current-limited, no damage, short-circuit protected 03 3 A Storage Temperature Range Vin = Zero (no power) -55 125 °C Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifi cations Table is not implied or recommended. INPUT Operating voltage range 36 48 75 Vdc Recommended External Fuse Fast blow 20 A Start-up threshold Rising input voltage 32 33.5 35 Vdc Undervoltage shutdown Falling input voltage 30 31.5 33 Vdc Internal Filter Type Pi Input current Full Load Conditions 8.59 8.68 A Low Line Vin = minimum 10.8 12 A Inrush Transient 0.3 A2-Sec. Output in Short Circuit 0.5 A No Load Input Current (Iout @ min) Iout = minimum, unit=ON 140 200 mA Shut-Down Mode Input Current 51 0 m A Refl ected (back) ripple current ➁ Measured at input with specifi ed fi lter 70 200 mA, RMS GENERAL and SAFETY Effi ciency Vin=48V, full load 95 96 % Vin=75V, full load 93 94 % Isolation Isolation Voltage, input to output 2250 Vdc Isolation Voltage, input to baseplate 1500 Vdc Isolation Voltage, output to baseplate 1500 Vdc Insulation Safety Rating basic Isolation Resistance 10 Mohm Isolation Capacitance 1500 pF Safety UL-60950-1, CSA-C22.2 No.60950-1, IEC/EN60950-1, 2nd Edition with Amendment 1 Yes Calculated MTBF Per Telcordia SR332, issue 1, class 3, ground fi xed, Tambient=+25°C 1.8 Hours x 10 6 DYNAMIC CHARACTERISTICS Fixed Switching Frequency 360 KHz Startup Delay Power On to Vout regulated, 10-90% Vout, resistive load 20 mS Startup Delay Remote ON to 10% of Vout 10 mS Dynamic Load Response 50-75-50% load step, settling time to within ±2% of Vout 350 μSec Dynamic Load Peak Deviation Same as above ±400 mV FEATURES and OPTIONS Remote On/Off Control ➃ “N” suffi x: Negative Logic, ON state ON = Pin grounded or external voltage -0.1 0.8 V Negative Logic, OFF state OFF = Pin open or external voltage 2.5 15 V Control Current Open collector/drain 1 2 mA “P” suffi x: Positive Logic, ON state ON = Pin open or external voltage 3.5 15 V Positive Logic, OFF state OFF = Ground pin or external voltage 0 1 V Control Current Open collector/drain 1 2 mA OUTPUT Conditions ➀ Minimum Typical/Nominal Maximum Units
www.murata-ps.com/support RBQ-12/33-D48xB-C Quarter-Brick 400-Watt Isolated DC-DC Converters MDC_RBQ-12/33-D48.A07 Δ Page 4 of 15 Total Output Power See Derating 0 386 391 W Voltage Nominal Output Voltage Measured @ 48Vin, Full Load. 11.4 11.7 12.5 Vdc Nominal Output Voltage Measured @ 48Vin, Half Load. 11.55 11.7 11.85 Vdc Total Output Range Over sample load (0-33A), input line (40-75V) and temperature (see derating curves) , for regular model and S option 11 12.5 V Vout Overshoot 12.9 13.1 V Voltage Output Voltage (initial output set point @48V, no load) For S option only 11.7 12.5 Vdc Output Voltage (initial output set point @48V, 50% load) For S option only 11.685 11.715 Vdc Output Voltage (initial output set point @48V, 100% load) For S option only 11.5 11.7 Vdc Output Voltage For S option only: total output range (input line, load, temperature, samples) 11.0 12.5 Vdc Overvoltage Protection Output Voltage clamped (see technical note) N/A V Current Output Current Range 03 3 3 3 A Minimum Load No minimum load Current Limit Inception 98% of Vnom., after warmup 40 46 50 A Short Circuit Short Circuit Current Hiccup technique, autorecovery within 1.25% of Vout 6A Short Circuit Duration (remove short for recovery) Output shorted to ground, no damage Continuous Short circuit protection method Current limiting Regulation ➄ Line Regulation Vin=40 to 75V +1/-2 % Load Regulation Iout=min. to max., Vin=48V ±3 % Ripple and Noise 5 Hz- 20 MHz BW 100 200 mV pk-pk Temperature Coeffi cient At all outputs 0.003 0.02 % of Vnom./°C Maximum Capacitive Loading (10% ceramic, 90% Oscon) Cap. ESR=<0.02Ω, Full resistive load 470 6000 μF MECHANICAL (Through Hole Models) Outline Dimensions 2.3 x 1.45 x 0.5 Inches 58.4 x 36.8 x 12.7 mm Weight 2.4 Ounces
69 Grams
Through Hole Pin Diameter Input pins 0.04 ±0.001 Inches 1.016±0.025 mm Through Hole Pin Diameter Output pins 0.060 ±0.001 Inches 1.524±0.025 mm Through Hole Pin Material Copper alloy TH Pin Plating Metal and Thickness Nickel subplate 100-299 μ-inches Gold overplate 3.9-20 μ-inches ENVIRONMENTAL Operating Ambient Temperature Range With derating, full power, no condensation, components +125˚C. max. -40 85 °C Storage Temperature Vin = Zero (no power) -55 125 °C Thermal Protection/Shutdown Measured at hotspot 115 125 130 °C Operating baseplate temperature -40 110 120 °C Electromagnetic Interference Conducted, EN55022/CISPR22 External fi lter is required B Class Relative humidity, non-condensing To +85°C 10 90 %RH Altitude must derate -1%/1000 feet -500 10,000 feet -152 3048 meters RoHS rating RoHS-6 Notes ➀ Unless otherwise noted, all specifi cations are at nominal input voltage, nominal output voltage and full load. General conditions are +25˚ Celsius ambient temperature, near sea level altitude, natural convection airfl ow. All models are tested and specifi ed with external parallel 1μF, 10μF and 470 μF output capacitors and 220 μF external input capacitor. All capacitors are low-ESR types wired close to the converter. These capacitors are necessary for our test equipment and may not be needed in the user’s application. ➁ Input (back) ripple current is tested and specifi ed over 5 Hz to 20 MHz bandwidth. Input fi ltering is Cbus = 220 μF, Cin = 220 μF and Lbus = 4.7 μH. ➂ All models are stable and regulate to specifi cation under no load. ➃ The Remote On/Off Control is referred to -Vin. ➄ Regulation specifi cations describe the output voltage changes as the line voltage or load current is varied from its nominal or midpoint value to either extreme. FUNCTIONAL SPECIFICATIONS (CONT.)
www.murata-ps.com/support PERFORMANCE DATA RBQ-12/33-D48xB-C Quarter-Brick 400-Watt Isolated DC-DC Converters MDC_RBQ-12/33-D48.A07 Δ Page 5 of 15 Effi ciency and Power Dissipation Typical Output Voltage (Vout) vs. Input Voltage (Vin) at +25°C 11.2 11.4 11.6 11.8 36 39 42 45 48 51 54 57 60 63 66 69 72 75 0% Load 50% Load 100% Load 3 6 9 12 15 18 21 24 27 30 33 Load Current (Amps) EfEE ficiency (%) Loss VIN = 36V VIN = 48V VIN = 75V Dissipation at 48V input Startup Delay (Vin = 48V, Iout = 33A, Vout = nom, Cload = 470μF, Ta = +25°C) Ch1 = Vin, Ch2 = Vout Output ripple and Noise (Vin = 48V, Iout = 0A, Vout = nom, Cload = 1μF || 10μF || 470μF, Ta = +25°C) Enable Startup Delay (Vin = 48V, Iout = 33A, Vout = nom, Cload = 470μF, Ta = +25°C) Ch2 = Vout, Ch4 = Enable Output ripple and Noise (Vin = 48V, Iout = 33A, Vout = nom, Cload = 1μF || 10μF || 470μF, Ta = +25°C) The RBQ-12/33-D48xB-C is not designed to be operated within the shaded area. The output voltage will be fully regulated within the white area in the graph above. Operation outside of this area is not recommended for normal use.
www.murata-ps.com/support RBQ-12/33-D48xB-C Quarter-Brick 400-Watt Isolated DC-DC Converters MDC_RBQ-12/33-D48.A07 Δ Page 6 of 15 PERFORMANCE DATA Step Load Transient Response (Vin = 48V, Iout = 50-75% of Imax, Cload = 470μF, Slew rate: 1A/uS, Ta = +25 °C.) (-Delta = 278mV, Recovery Time = 164uS) Step Load Transient Response (Vin = 48V, Iout = 75-50% of Imax, Cload = 470μF, Slew rate: 1A/uS, Ta = +25 °C.) (-Delta = 266mV, Recovery Time = 156uS) Step Load Transient Response (Vin = 48V, Iout = 50-75-50% of Imax, Cload = 470μF, Slew rate: 1A/uS, Ta = +25 °C.) Current Sharing* Ta=25°C, Vin=48V 0 6 12 18 24 30 36 42 48 54 60 66 No. 1 Load No. 2 Load Total Output Load (Amps) Current Share Load (Amps) *See Technical note section
www.murata-ps.com/support PERFORMANCE DATA RBQ-12/33-D48xB-C Quarter-Brick 400-Watt Isolated DC-DC Converters MDC_RBQ-12/33-D48.A07 Δ Page 7 of 15 Maximum Current Temperature Derating in Transverse Direction Vin= 40V (air fl ow is from -Vin to +Vin) Maximum Current Temperature Derating in Longitudinal Direction Vin= 40V (air fl ow is from Vin to Vout) 30 35 40 45 50 55 60 65 70 75 80 85 Output Current (Amps) Ambient Temperature (ºC) 0.5 m/s (100LFM) 1.0 m/s (200LFM) 1.5 m/s (300LFM) 2.0 m/s (400LFM) 2.5 m/s (500LFM) 3.0 m/s (600LFM) 30 35 40 45 50 55 60 65 70 75 80 85 Output Current (Amps) Ambient Temperature (ºC) 0.5 m/s (100LFM) 1.0 m/s (200LFM) 1.5 m/s (300LFM) 2.0 m/s (400LFM) 2.5 m/s (500LFM) 3.0 m/s (600LFM) Maximum Current Temperature Derating in Transverse Direction Vin= 48V (air fl ow is from -Vin to +Vin) 30 35 40 45 50 55 60 65 70 75 80 85 Output Current (Amps) Ambient Temperature (ºC) 0.5 m/s (100LFM) 1.0 m/s (200LFM) 1.5 m/s (300LFM) 2.0 m/s (400LFM) 2.5 m/s (500LFM) 3.0 m/s (600LFM) Maximum Current Temperature Derating in Longitudinal Direction Vin= 48V (air fl ow is from Vin to Vout) 30 35 40 45 50 55 60 65 70 75 80 85 Output Current (Amps) Ambient Temperature (ºC) 0.5 m/s (100LFM) 1.0 m/s (200LFM) 1.5 m/s (300LFM) 2.0 m/s (400LFM) 2.5 m/s (500LFM) 3.0 m/s (600LFM) Maximum Current Temperature Derating in Longitudinal Direction Vin= 75V (air fl ow is from Vin to Vout) 30 35 40 45 50 55 60 65 70 75 80 85 Output Current (Amps) Ambient Temperature (ºC) 0.5 m/s (100LFM) 1.0 m/s (200LFM) 1.5 m/s (300LFM) 2.0 m/s (400LFM) 2.5 m/s (500LFM) 3.0 m/s (600LFM) Maximum Current Temperature Derating in Transverse Direction Vin= 75V (air fl ow is from -Vin to +Vin) 30 35 40 45 50 55 60 65 70 75 80 85 Output Current (Amps) Ambient Temperature (ºC) 0.5 m/s (100LFM) 1.0 m/s (200LFM) 1.5 m/s (300LFM) 2.0 m/s (400LFM) 2.5 m/s (500LFM) 3.0 m/s (600LFM)
www.murata-ps.com/support RBQ-12/33-D48xB-C Quarter-Brick 400-Watt Isolated DC-DC Converters MDC_RBQ-12/33-D48.A07 Δ Page 8 of 15 MECHANICAL SPECIFICATIONS (THROUGH-HOLE MOUNT) Third Angle Projection Dimensions are in inches (mm shown for ref. only). Components are shown for reference only and may vary between units. Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) Angles ± 2˚ INPUT/OUTPUT CONNECTIONS Pin Function 1 +Vin
2 Remote On/Off
3 −Vin 4 −Vout 8 +Vout The 0.145" (L2) pin length is shown. Please refer to the part number structure for alternate pin lengths. L 0.010 minimum clearance between standoffs and highest component BASEPLATE OPTION PINS 1-3,: Shoulder: ϕ0.076±0.005(1.93±0.13) PINS 4,8: Shoulder: ϕ0.098±0.005(2.49±0.13)
0.52 Max
1.45 SEE NOTE 6 2.000 (50.8) 2.30 (58.42) 1.860 (47.24) 0.210 (5.33) 0.220 (5.59) 1.030 (26.16)
www.murata-ps.com/support SHIPPING TRAYS AND BOXES, THROUGH-HOLE MOUNT SHIPPING TRAY DIMENSIONS RBQ-12/33-D48xB-C Quarter-Brick 400-Watt Isolated DC-DC Converters MDC_RBQ-12/33-D48.A07 Δ Page 9 of 15
30 CONVERTERS PER CARTON
TWO (2) TRAYS YIELDING MPQ=30 ±.2511.00 ±.2510.50 2.75±0.25 CLOSED HEIGHT EACH STATIC DISSIPATIVE POLYETHYLENE FOAM TRAY ACCOMMODATES 15 CONVERTERS IN A 3 X 5 ARRAY 9.92 REF REF 9.92 0.88 REF RBQ modules are supplied in a 15-piece (5 x 3) shipping tray. The tray is an anti-static closed-cell polyethylene foam. Dimensions are shown below. Notes: Material: Dow 220 antistat ethafoam1. (Density: 34-35 kg/m3) Dimensions: 252 x 252 x 19.1 mm2. 5 x 3 array (15 per tray) 3. All dimensions in millimeters [inches] 4. Tolerances unless otherwise specified: +1/-0 [9.92] 252.0 L 36.83 [1.450] TYP TYP 18.67 [0.735] 60.96 [2.400] TYP 15.875 [0.625] 18.42 [0.725] TYP C 6.35 [.25] CHAMFER TYP (4-PL) 6.35 [.25] R TYP -.062 +.000 [9.92] 252.0 -.062 +.000 46.36 [1.825] TYP
the redundant elements, while achieving the goal of increased availability. the instantaneous input voltage to go below the minimum voltage at all times. copper. Run additional bus wire if necessary. PWM controller at power up, thereby limiting the input inrush current. such as external load capacitance and soft start circuitry. operate with no additional external capacitance if these conditions are met. electrolytic or tantalum) if needed. tance to reduce the ripple even further or for improved dynamic response. Again, use low-ESR ceramic (Murata GRM32 series) or polymer capacitors. tance listed in the specifi cations. components simulate a typical DC voltage bus. Figure 5. Measuring Input Ripple Current
installed and the circuit diagram is shown below. refer to Application Note GEAN-02 for further discussion. recommend using an engineer who is experienced at emissions suppression. Figure 10. Conducted Emissions Test Circuit
notice. © 2014 Murata Power Solutions, Inc. Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A. tions may cause damage to the product. Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers. Maximum Preheat Temperature 115° C. Maximum Preheat Temperature 105° C. Maximum Pot Temperature 270° C. Maximum Pot Temperature 250° C. Figure 11. Vertical Wind Tunnel airfl ow and heat dissipation analysis of power products. temperature gauges, and adjustable heating element. range of measurement conditions can be studied. that power supplies are tested in real-world conditions.